997 resultados para non radiographic axial spondylarthritis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medical charts and radiographs from 38 HIV-infected patients with positive cultures for Mycobacterium tuberculosis from sputum or bronchoalveolar lavage were reviewed in order to compare the clinical, radiographic, and sputum bacilloscopy characteristics of HIV-infected patients with pulmonary tuberculosis according to CD4+ lymphocyte count (CD4). The mean age of the patients was 32 years and 76% were male. The median CD4 was 106 cells/mm³ and 71% had CD4 < 200 cells/mm³. Sputum bacilloscopy was positive in 45% of the patients. Patients with CD4 < 200 cells/mm³ showed significantly less post-primary pattern (7% vs. 63%; p = 0.02) and more frequently reported weight loss (p = 0.04). Although not statistically significant, patients with lower CD4 showed lower positivity of sputum bacilloscopy (37% vs. 64%; p = 0.18). HIV-infected patients with culture-confirmed pulmonary tuberculosis had a high proportion of non-post-primary pattern in thoracic radiographs. Patients with CD4 lower than 200 cells/mm³ showed post-primary patterns less frequently and reported weight loss more frequently.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies evaluating the mechanical behavior of the trabecular microstructure play an important role in our understanding of pathologies such as osteoporosis, and in increasing our understanding of bone fracture and bone adaptation. Understanding of such behavior in bone is important for predicting and providing early treatment of fractures. The objective of this study is to present a numerical model for studying the initiation and accumulation of trabecular bone microdamage in both the pre- and post-yield regions. A sub-region of human vertebral trabecular bone was analyzed using a uniformly loaded anatomically accurate microstructural three-dimensional finite element model. The evolution of trabecular bone microdamage was governed using a non-linear, modulus reduction, perfect damage approach derived from a generalized plasticity stress-strain law. The model introduced in this paper establishes a history of microdamage evolution in both the pre- and post-yield regions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Prediction of clinical course and outcome after severe traumatic brain injury (TBI) is important. OBJECTIVE: To examine whether clinical scales (Glasgow Coma Scale [GCS], Injury Severity Score [ISS], and Acute Physiology and Chronic Health Evaluation II [APACHE II]) or radiographic scales based on admission computed tomography (Marshall and Rotterdam) were associated with intensive care unit (ICU) physiology (intracranial pressure [ICP], brain tissue oxygen tension [PbtO2]), and clinical outcome after severe TBI. METHODS: One hundred one patients (median age, 41.0 years; interquartile range [26-55]) with severe TBI who had ICP and PbtO2 monitoring were identified. The relationship between admission GCS, ISS, APACHE II, Marshall and Rotterdam scores and ICP, PbtO2, and outcome was examined by using mixed-effects models and logistic regression. RESULTS: Median (25%-75% interquartile range) admission GCS and APACHE II without GCS scores were 3.0 (3-7) and 11.0 (8-13), respectively. Marshall and Rotterdam scores were 3.0 (3-5) and 4.0 (4-5). Mean ICP and PbtO2 during the patients' ICU course were 15.5 ± 10.7 mm Hg and 29.9 ± 10.8 mm Hg, respectively. Three-month mortality was 37.6%. Admission GCS was not associated with mortality. APACHE II (P = .003), APACHE-non-GCS (P = .004), Marshall (P < .001), and Rotterdam scores (P < .001) were associated with mortality. No relationship between GCS, ISS, Marshall, or Rotterdam scores and subsequent ICP or PbtO2 was observed. The APACHE II score was inversely associated with median PbtO2 (P = .03) and minimum PbtO2 (P = .008) and had a stronger correlation with amount of time of reduced PbtO2. CONCLUSION: Following severe TBI, factors associated with outcome may not always predict a patient's ICU course and, in particular, intracranial physiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present dual-wavelength Digital Holographic Microscopy (DHM) measurements on a certified 8.9 nm high Chromium thin step sample and demonstrate sub-nanometer axial accuracy. We introduce a modified DHM Reference Calibrated Hologram (RCH) reconstruction algorithm taking into account amplitude contributions. By combining this with a temporal averaging procedure and a specific dual-wavelength DHM arrangement, it is shown that specimen topography can be measured with an accuracy, defined as the axial standard deviation, reduced to at least 0.9 nm. Indeed, it is reported that averaging each of the two wavefronts recorded with real-time dual-wavelength DHM can provide up to 30% spatial noise reduction for the given configuration, thanks to their non-correlated nature. ©2008 COPYRIGHT SPIE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Allergy to radiographic contrast media Hypersensitivity reactions to radio-contrast media are common in the daily practice. These products are responsible for immediate (< or = 1 hour after administration) and non immediate (> 1 hour after administration) hypersensitivity reactions. A diagnostic work-up by an allergologist with skin tests and in some cases provocation tests is of value in reducing the risk of recurrent hypersensitivity reactions to iodinated contrast media. A careful selection of the patients is required because the incidence of breakthrough reactions is still concerning, even with proper premedication. Practical recommendations are presented in this article. For gadolinium-based contrast agents, data in the literature is not sufficient for suggesting guidelines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Spinal cord ischaemia is rare in childhood and information on clinical presentation and outcome is scarce. METHODS: This is a retrospective analysis of eight patients and 75 additional cases from the literature. Data search included: patient's age, primary manifestation, risk factors, neuroimaging and outcome. RESULTS: Five female and three male patients gave consent to participate. Mean age was 12.5 years (10-15 years). Six patients presented with paraplegia; this was preceded by pain in four. Brown Sequard syndrome and quadriparesis were the two others' presenting condition. Sensation levels were thoracolumbar in seven cases. Bladder dysfunction only or bladder and bowel dysfunction were reported in eight and five patients respectively. Time to maximal symptom manifestation was <12 h in 7/8. Risk factors included surgery, minor trauma, recent infection, and thrombophilia. Mean follow-up was 3.3 years (0.25-6.3 years). Three patients remained wheelchair-dependent and three patients were ambulatory without aid. Bladder function recovered fully in five children. Most affected aspects of quality of life were physical and mental well-being and self-perception. T2-weighted-MR images showed pencil-like hyperintensity (8/8) in sagittal and H-shaped or snake-eyes-like lesion (6/8) in axial views. Analyses of all 83 patients were in congruence with the above results of the study group. CONCLUSION: Spinal cord ischaemia in childhood presenting with pain, paraplegia, and bladder dysfunction has high morbidity concerning motor problems and quality of life. Acute arterial ischaemic event in children seems similar to adult events with respect to clinical presentation and, surprisingly, also in outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chiasmal dysfunction produces a characteristic clinical picture, regardless of the mechanism. In most cases a compressive lesion is the cause. In occasional cases, however, no such extrinsic mass is found and other possible etiologies must be explored. In some of these cases, the pathologic process is identifiable with appropriate neuroimaging. For example, inflammation, infiltrative tumors, and radiation necrosis produce intrinsic chiasmal enhancement. Chiasmal ischemia may require specialized magnetic resonance (MR) sequences for diagnosis. Chiasmal hemorrhage, trauma and chiasmal herniation typically produce distinctive changes on noncontrasted imaging. In cases of metabolic insult, either toxic or hereditary, radiographic changes are typically absent. In each of these, the correct diagnosis can usually be made with a combination of clinical and radiographic features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A joint project between the Paul Scherrer Institut (PSI) and the Institute of Radiation Physics was initiated to characterise the PSI whole body counter in detail through measurements and Monte Carlo simulation. Accurate knowledge of the detector geometry is essential for reliable simulations of human body phantoms filled with known activity concentrations. Unfortunately, the technical drawings provided by the manufacturer are often not detailed enough and sometimes the specifications do not agree with the actual set-up. Therefore, the exact detector geometry and the position of the detector crystal inside the housing were determined through radiographic images. X-rays were used to analyse the structure of the detector, and (60)Co radiography was employed to measure the core of the germanium crystal. Moreover, the precise axial alignment of the detector within its housing was determined through a series of radiographic images with different incident angles. The hence obtained information enables us to optimise the Monte Carlo geometry model and to perform much more accurate and reliable simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of non-metallic load transfer and reinforcement devices for concrete highway pavements is a possible alternative to avoid corrosion problems related to the current practice of steel materials. Laboratory and field testing of highway pavement dowel bars, made of both steel and fiber composite materials, and fiber composite tie rods were carried out in this research investigation. Fatigue, static, and dynamic testing was performed on full-scale concrete pavement slabs which were supported by a simulated subgrade and which included a single transverse joint. The bahavior of the full-scale specimens with both steel and fiber composite dowels placed in the test joints was monitored during several million load cycles which simulated truck traffic at a transverse joint. Static bond tests were conducted on fiber composite tie rods to determine the required embedment length. These tests took the form of bending tests which included curvature and shear in the embedment zone and pullout tests which subjected the test specimen to axial tension only. Fiber composite dowel bars were placed at two transverse joints during construction of a new concrete highway pavement in order to evaluate their performance under actual field conditions. Fiber composite tie rods were also placed in the longitudinal joint between the two fiber composite doweled transverse joints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Progressive pseudorheumatoid dysplasia (PPRD) is a genetic, non-inflammatory arthropathy caused by recessive loss of function mutations in WISP3 (Wnt1-inducible signaling pathway protein 3; MIM 603400), encoding for a signaling protein. The disease is clinically silent at birth and in infancy. It manifests between the age of 3 and 6 years with joint pain and progressive joint stiffness. Affected children are referred to pediatric rheumatologists and orthopedic surgeons; however, signs of inflammation are absent and anti-inflammatory treatment is of little help. Bony enlargement at the interphalangeal joints progresses leading to camptodactyly. Spine involvement develops in late childhood and adolescence leading to short trunk with thoracolumbar kyphosis. Adult height is usually below the 3rd percentile. Radiographic signs are relatively mild. Platyspondyly develops in late childhood and can be the first clue to the diagnosis. Enlargement of the phalangeal metaphyses develops subtly and is usually recognizable by 10 years. The femoral heads are large and the acetabulum forms a distinct "lip" overriding the femoral head. There is a progressive narrowing of all articular spaces as articular cartilage is lost. Medical management of PPRD remains symptomatic and relies on pain medication. Hip joint replacement surgery in early adulthood is effective in reducing pain and maintaining mobility and can be recommended. Subsequent knee joint replacement is a further option. Mutation analysis of WISP3 allowed the confirmation of the diagnosis in 63 out of 64 typical cases in our series. Intronic mutations in WISP3 leading to splicing aberrations can be detected only in cDNA from fibroblasts and therefore a skin biopsy is indicated when genomic analysis fails to reveal mutations in individuals with otherwise typical signs and symptoms. In spite of the first symptoms appearing in early childhood, the diagnosis of PPRD is most often made only in the second decade and affected children often receive unnecessary anti-inflammatory and immunosuppressive treatments. Increasing awareness of PPRD appears to be essential to allow for a timely diagnosis. © 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electric motors driven by adjustable-frequency converters may produce periodic excitation forces that can cause torque and speed ripple. Interaction with the driven mechanical system may cause undesirable vibrations that affect the system performance and lifetime. Direct drives in sensitive applications, such as elevators or paper machines, emphasize the importance of smooth torque production. This thesis analyses the non-idealities of frequencyconverters that produce speed and torque ripple in electric drives. The origin of low order harmonics in speed and torque is examined. It is shown how different current measurement error types affect the torque. As the application environment, direct torque control (DTC) method is applied to permanent magnet synchronous machines (PMSM). A simulation model to analyse the effect of the frequency converter non-idealities on the performance of the electric drives is created. Themodel enables to identify potential problems causing torque vibrations and possibly damaging oscillations in electrically driven machine systems. The model is capable of coupling with separate simulation software of complex mechanical loads. Furthermore, the simulation model of the frequency converter's control algorithm can be applied to control a real frequency converter. A commercial frequencyconverter with standard software, a permanent magnet axial flux synchronous motor and a DC motor as the load are used to detect the effect of current measurement errors on load torque. A method to reduce the speed and torque ripple by compensating the current measurement errors is introduced. The method is based on analysing the amplitude of a selected harmonic component of speed as a function oftime and selecting a suitable compensation alternative for the current error. The speed can be either measured or estimated, so the compensation method is applicable also for speed sensorless drives. The proposed compensation method is tested with a laboratory drive, which consists of commercial frequency converter hardware with self-made software and a prototype PMSM. The speed and torque rippleof the test drive are reduced by applying the compensation method. In addition to the direct torque controlled PMSM drives, the compensation method can also beapplied to other motor types and control methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Psoriatic arthritis is a chronic inflammatory disease. It affects up to 40% of patients suffe- ring from skin psoriasis. Joint involvement is relatively heterogeneous. Some clinical manifestations are similar to those of rheumatoid arthritis, others are close to spondylarthritis manifestations and are therefore considered as part of this entity. Treatment depends on initial presentation (peripheral or axial) but often begins with non-steroidal anti-inflammatory drugs and methotrexate, followed by anti-TNFalpha if needed. New therapeutic op- tions are available or under evaluation, parti- cularly targeting cytokines involved in psoriatic arthritis (IL-12/IL-23 and IL-17).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We derive a one dimensional formulation of the Planck-Nernst-Poisson equation to describe the dynamics of of a symmetric binary electrolyte in channels whose section is of nanometric section and varies along the axial direction. The approach is in the spirit of the Fick-Jacobs di fusion equation and leads to a system of coupled equations for the partial densities which depends on the charge sitting at the walls in a non trivial fashion. We consider two kinds of non uniformities, those due to the spatial variation of charge distribution and those due to the shape variation of the pore and report one and three-dimensional solutions of the electrokinetic equations.