961 resultados para motion analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on our previously developed electrical heart model, an electromechanical biventricular model, which couples the electrical property and mechanical property of the heart, was constructed and the right ventricular wall motion and deformation was simulated using this model. The model was developed on the basis of composite material theory and finite element method. The excitation propagation was simulated by electrical heart model, and the resultant active forces were used to study the ventricular wall motion during systole. The simulation results show that: (1) The right ventricular free wall moves towards the septum, and at the same time, the base and middle of free wall move towards the apex, which reduce the volume of right ventricle; (2) The minimum principle strain (E3) is largest at the apex, then at the middle of free wall, and its direction is in the approximate direction of epicardial muscle fibers. These results are in good accordance with solutions obtained from MR tagging images. It suggests that such electromechanical biventricular model can be used to assess the mechanical function of two ventricles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to quantify movement patterns of batsmen scoring 100 runs (century), including analysis at 50, 80, and 100 runs, in Test and One-Day international (one-day) matches and between the first and second 50 within a Test century. Test centuries (n = 13) and one-day scores above 80 (n = 12) filmed during the 2005 - 2006 Australian international season were analysed for movement patterns of standing, walking, jogging, striding, sprinting, shot playing, and turning. At each run target, differences in total time, duration of individual movement pattern, movement pattern frequency, and number of balls faced were determined between Test and one-day matches (analysis of variance). Differences within Test centuries were assessed using paired t-tests. A similar fractional predominance of time spent in low-intensity activity (standing and walking) between Test and one-day matches at each run target (94 and 96% respectively) was observed, with no differences in duration of striding or sprinting (Test: 1.1 min, s = 0.5; one-day: 0.9 min, s = 0.5 for sprinting: P = 0.28). A 37% longer total duration occurred in Tests, resulting in longer recovery bouts between high-intensity efforts. There were no differences between the first and second 50 runs of a Test century for any measure (P at best = 0.34). In summary, Test and one-day centuries are characterized by much low-intensity activity and patterns of high-intensity activity similar to many repeat-sprint team sports and greater recovery breaks in longer matches.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In 1999 Richards compared the accuracy of commercially available motion capture systems commonly used in biomechanics. Richards identified that in static tests the optical motion capture systems generally produced RMS errors of less than 1.0 mm. During dynamic tests, the RMS error increased to up to 4.2 mm in some systems. In the last 12 years motion capture systems have continued to evolve and now include high-resolution CCD or CMOS image sensors, wireless communication, and high full frame sampling frequencies. In addition to hardware advances, there have also been a number of advances in software, which includes improved calibration and tracking algorithms, real time data streaming, and the introduction of the c3d standard. These advances have allowed the system manufactures to maintain a high retail price in the name of advancement. In areas such as gait analysis and ergonomics many of the advanced features such as high resolution image sensors and high sampling frequencies are not required due to the nature of the task often investigated. Recently Natural Point introduced low cost cameras, which on face value appear to be suitable as at very least a high quality teaching tool in biomechanics and possibly even a research tool when coupled with the correct calibration and tracking software. The aim of the study was therefore to compare both the linear accuracy and quality of angular kinematics from a typical high end motion capture system and a low cost system during a simple task.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Opening keynote address.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the study is to characterize the local muscles motion in individuals undergoing whole body mechanical stimulation. In this study we aim also to evaluate how subject positioning modifies vibration dumping, altering local mechanical stimulus. Vibrations were delivered to subjects by the use of a vibrating platform, while stimulation frequency was increased linearly from 15 to 60Hz. Two different subject postures were here analysed. Platform and muscles motion were monitored using tiny MEMS accelerometers; a contra lateral analysis was also presented. Muscle motion analysis revealed typical displacement trajectories: motion components were found not to be purely sinusoidal neither in phase to each other. Results also revealed a mechanical resonant-like behaviour at some muscles, similar to a second-order system response. Resonance frequencies and dumping factors depended on subject and his positioning. Proper mechanical stimulation can maximize muscle spindle solicitation, which may produce a more effective muscle activation. © 2010 M. Cesarelli et al.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction and Objectives Joint moments and joint powers during gait are widely used to determine the effects of rehabilitation programs as well as prosthetic fitting. Following the definition of power (dot product of joint moment and joint angular velocity) it has been previously proposed to analyse the 3D angle between both vectors, αMw. Basically, joint power is maximised when both vectors are parallel and cancelled when both vectors are orthogonal. In other words, αMw < 60° reveals a propulsion configuration (more than 50% of the moment contribute to positive power) while αMw > 120° reveals a resistance configuration (more than 50% of the moment contribute to negative power). A stabilisation configuration (less than 50% of the moment contribute to power) corresponds to 60° < αMw < 120°. Previous studies demonstrated that hip joints of able-bodied adults (AB) are mainly in a stabilisation configuration (αMw about 90°) during the stance phase of gait. [1, 2] Individuals with transfemoral amputation (TFA) need to maximise joint power at the hip while controlling the prosthetic knee during stance. Therefore, we tested the hypothesis that TFAs should adopt a strategy that is different from a continuous stabilisation. The objective of this study was to compute joint power and αMw for TFA and to compare them with AB. Methods Three trials of walking at self-selected speed were analysed for 8 TFAs (7 males and 1 female, 46±10 years old, 1.78±0.08 m 82±13 kg) and 8 ABs (males, 25±3 years old, 1.75±0.04, m 67±6 kg). The joint moments are computed from a motion analysis system (Qualisys, Goteborg, Sweden) and a multi-axial transducer (JR3, Woodland, USA) mounted above the prosthetic knee for TFAs and from a motion analysis system (Motion Analysis, Santa Rosa, USA) and force plates (Bertec, Columbus, USA) for ABs. The TFAs were fitted with an OPRA (Integrum, AB, Gothengurg, Sweden) osseointegrated implant system and their prosthetic designs include pneumatic, hydraulic and microprocessor knees. Previous studies showed that the inverse dynamics computed from the multi-axial transducer is the proper method considering the absorption at the foot and resistance at the knee. Results The peak of positive power at loading response (H1) was earlier and lower for TFA compared to AB. Although the joint power is lower, the 3D angle between joint moment and joint angular velocity, αMw, reveals an obvious propulsion configuration (mean αMw about 20°) for TFA compared to a stabilisation configuration (mean αMw about 70°) for AB. The peaks of negative power at midstance (H2) and of positive power at preswing / initial swing (H3) occurred later, lower and longer for TFA compared to AB. Again, the joint powers are lower for TFA but, in this case, αMw is almost comparable (with a time lag), demonstrating a stabilisation (almost a resistance for TFA, mean αMw about 120°) and a propulsion configuration, respectively. The swing phase is not analysed in the present study. Conclusion The analysis of hip joint power may indicate that TFAs demonstrated less propulsion and resistance than ABs during the stance phase of gait. This is true from a quantitative point of view. On the contrary, the 3D angle between joint moment and joint angular velocity, αMw, reveals that TFAs have a remarkable propulsion strategy at loading response and almost a resistance strategy at midstance while ABs adopted a stabilisation strategy. The propulsion configuration, with αMw close to 0°, seems to aim at maximising the positive joint power. The configuration close to resistance, with αMw far from 180°, might aim at unlocking the prosthetic knee before swing while minimising the negative power. This analysis of both joint power and 3D angle between the joint moment and the joint angular velocity provides complementary insights into the gait strategies of TFA that can be used to support evidence-based rehabilitation and fitting of prosthetic components.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We present a motion detection algorithm which detects direction of motion at sufficient number of points and thus segregates the edge image into clusters of coherently moving points. Unlike most algorithms for motion analysis, we do not estimate magnitude of velocity vectors or obtain dense motion maps. The motivation is that motion direction information at a number of points seems to be sufficient to evoke perception of motion and hence should be useful in many image processing tasks requiring motion analysis. The algorithm essentially updates the motion at previous time using the current image frame as input in a dynamic fashion. One of the novel features of the algorithm is the use of some feedback mechanism for evidence segregation. This kind of motion analysis can identify regions in the image that are moving together coherently, and such information could be sufficient for many applications that utilize motion such as segmentation, compression, and tracking. We present an algorithm for tracking objects using our motion information to demonstrate the potential of this motion detection algorithm.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Here, we describe a motion stimulus in which the quality of rotation is fractal. This makes its motion unavailable to the translationbased motion analysis known to underlie much of our motion perception. In contrast, normal rotation can be extracted through the aggregation of the outputs of translational mechanisms. Neural adaptation of these translation-based motion mechanisms is thought to drive the motion after-effect, a phenomenon in which prolonged viewing of motion in one direction leads to a percept of motion in the opposite direction. We measured the motion after-effects induced in static and moving stimuli by fractal rotation. The after-effects found were an order of magnitude smaller than those elicited by normal rotation. Our findings suggest that the analysis of fractal rotation involves different neural processes than those for standard translational motion. Given that the percept of motion elicited by fractal rotation is a clear example of motion derived from form analysis, we propose that the extraction of fractal rotation may reflect the operation of a general mechanism for inferring motion from changes in form.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, we propose a new velocity constraint type for Redundant Drive Wire Mechanisms. The purpose of this paper is to demonstrate that the proposed velocity constraint module can fix the orientation of the movable part and to use the kinematical analysis method to obtain the moving direction of the movable part. First, we discuss the necessity of using this velocity constraint type and the possible applications of the proposed mechanism. Second, we derive the basic equations of a wire mechanism with this constraint type. Next, we present a method of motion analysis on active and passive constraint spaces, which is used to find the moving direction of a movable part. Finally, we apply the above analysis method on a wire mechanism with a velocity constraint module and on a wire mechanism with four double actuator modules. By evaluating the results, we prove the validity of the proposed constraint type.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work constitutes the first attempt to extract an important narrative structure, the 3-Act story telling paradigm, in film. This narrative structure is prevalent in the domain of film as it forms the foundation and framework in which the film can be made to function as an effective tool for story telling, and its extraction is a vital step in automatic content management for film data. A novel act boundary likelihood function for Act 1 is derived using a Bayesian formulation under guidance from film grammar, tested under many configurations and the results are reported for experiments involving 25 full length movies. The formulation is shown to be a useful tool in both the automatic and semi-interactive setting for semantic analysis of film.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper examines film rhythm, an important expressive element in motion pictures, based on our ongoing study to exploit film grammar as a broad computational framework for the task of automated film and video understanding. Of the many, more or less elusive, narrative devices contributing to film rhythm, this paper discusses motion characteristics that form the basis of our analysis, and presents novel computational models for extracting rhythmic patterns induced through a perception of motion. In our rhythm model, motion behaviour is classified as being either nonexistent, fluid or staccato for a given shot. Shot neighbourhoods in movies are then grouped by proportional makeup of these motion behavioural classes to yield seven high-level rhythmic arrangements that prove to be adept at indicating likely scene content (e.g. dialogue or chase sequence) in our experiments. Underlying causes for this level of codification in our approach are postulated from film grammar, and are accompanied by detailed demonstration from real movies for the purposes of clarification.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Global positioning system (GPS) technology has improved the speed, accuracy, and ease of time-motion analyses of field sport athletes. The large volume of numerical data generated by GPS technology is usually summarized by reporting the distance traveled and time spent in various locomotor categories (e.g., walking, jogging, and running). There are a variety of definitions used in the literature to represent these categories, which makes it nearly impossible to compare findings among studies.

The purpose of this work was to propose standard definitions (velocity ranges) that were determined by an objective analysis of time-motion data. In addition, we discuss the limitations of the existing definition of a sprint and present a new definition of sprinting for field sport athletes.

Twenty-five GPS data files collected from 5 different sports (men’s and women’s field hockey, men’s and women’s soccer, and Australian Rules Football) were analyzed to identify the average velocity distribution. A curve fitting process was then used to determine the optimal placement of 4 Gaussian curves representing the typical locomotor categories. 


Based on the findings of these analyses, we make recommendations about sport- specific velocity ranges to be used in future time-motion studies of field sport athletes. We also suggest that a sprint be defined as any movement that reaches or exceeds the sprint threshold velocity for at least 1 second and any movement with an acceleration that occurs within the highest 5% of accelerations found in the corresponding velocity range.

From a practical perspective, these analyses provide conditioning coaches with information on the high-intensity sprinting demands of field sport athletes, while also providing a novel method of capturing maximal effort, short-duration sprints.