992 resultados para mitral implantation
Resumo:
This paper presents a relatively simple method to fabricate field-emitter arrays from silicon substrates. These devices are obtained from silicon micromachining by means of the HI-PS technique-a combination of hydrogen ion implantation and porous silicon used as sacrificial layer. Also, a new process sequence is proposed and implemented to fabricate self-aligned integrated field-emission devices based on this technique. Electrical characteristics of the microtips obtained show good agreement with the Fowler-Nordheim theory, which are suitable for the proposed application.
Resumo:
Background and aim of the study: Results of valve re-replacement (reoperation) in 898 patients undergoing aortic valve replacement with cryopreserved homograft valves between 1975 and 1998 are reported. The study aim was to provide estimates of unconditional probability of valve reoperation and cumulative incidence function (actual risk) of reoperation. Methods: Valves were implanted by subcoronary insertion (n = 500), inclusion cylinder (n = 46), and aortic root replacement (n = 352). Probability of reoperation was estimated by adopting a mixture model framework within which estimates were adjusted for two risk factors: patient age at initial replacement, and implantation technique. Results: For a patient aged 50 years, the probability of reoperation in his/her lifetime was estimated as 44% and 56% for non-root and root replacement techniques, respectively. For a patient aged 70 years, estimated probability of reoperation was 16% and 25%, respectively. Given that a reoperation is required, patients with non-root replacement have a higher hazard rate than those with root replacement (hazards ratio = 1.4), indicating that non-root replacement patients tend to undergo reoperation earlier before death than root replacement patients. Conclusion: Younger patient age and root versus non-root replacement are risk factors for reoperation. Valve durability is much less in younger patients, while root replacement patients appear more likely to live longer and hence are more likely to require reoperation.
Resumo:
The advance of agricultural frontier may cause the Cerrado (Brazilian savanna) to disappear before 2030. This work focuses on measuring the impact of pasture implantation on a cerrado`s termite fauna. Termites were sampled in a cerrado sensu stricto and a pasture, originally cerrado. All species were classified as their feeder group, accumulation curves were made and Shannon-Wiener indexes and beta diversity were calculated for both areas. Cerrado was richer than pasture and species composition differed considerably, leading beta diversity to a high value. The humivorous was the most representative species, followed by grass/litter feeders, xylophagous and, less representative, the intermediates. There were more xylophagous and intermediates species on cerrado than in pasture; the grass/litter feeders were more abundant in pasture, but didn`t differed in number or species; and humivorous didn`t differed neither in richness nor in abundance. This work shows that the simplification of the habitat is indeed causing the extinction of populations that depend on some specifics resource.
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
PURPOSE To compare reading ability after cataract surgery and bilateral implantation of multifocal intraocular lenses (IOLs) with a +3 00 diopter (D) addition (add) or a +4 00 D add SETTING Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil DESIGN Prospective comparative study METHODS Patients scheduled for cataract surgery were randomly assigned to bilateral implantation of an aspheric AcrySof ReSTOR multifocal IOL with a +3 00 diopter (D) addition (add) or a +4 00 D add The reading speed, critical print size, and reading acuity were measured binocularly with best correction using MNREAD acuity charts 6 months after surgery Patients were tested with the chart at the best patient-preferred reading distance and at 40 cm Binocular uncorrected and best distance-corrected visual acuities at far and near were also measured RESULTS The study enrolled 32 patients At the best reading distance the results were similar between the 2 IOL groups in all reading parameters When tested at 40 cm, reading speed at all print sizes from 03 to 00 (all P< 001), critical print size (P< 001) and reading acuity (P = 014) were statistically significantly better in the +3 00 D IOL group than in the +4 00 DIOL group Uncorrected and corrected visual acuities at far and near were similar between the 2 groups CONCLUSION Although the 2 IOL groups had similar performance in reading parameters, patients had to adjust to their best reading distance The +3 00 D IOL performed better than the +4 00 D IOL at 40 cm
Resumo:
Pulmonary hypertension represents an important cause of morbidity and mortality in patients with mitral stenosis who undergo cardiac surgery, especially in the postoperative period. The aim of this study was to test the hypothesis that inhaled nitric oxide (iNO) would improve the hemodynamic effects and short-term clinical outcomes of patients with mitral stenosis and severe pulmonary hypertension who undergo cardiac surgery in a randomized, controlled study. Twenty-nine patients (4 men, 25 women; mean age 46 2 years) were randomly allocated to receive iNO (n = 14) or oxygen (n = 15) for 48 hours immediately after surgery. Hemodynamic data, the use of vasoactive drugs, duration of stay, and short-term complications were assessed. No differences in baseline characteristics were observed between the groups. After 24 and 48 hours, patients receiving iNO had a significantly greater increase in cardiac index compared to patients receiving oxygen (p < 0.0001). Pulmonary vascular resistance was also more significantly reduced in patients receiving iNO versus oxygen (-117 dyne/s/cm(5), 95% confidence interval 34 to 200, vs 40 dyne/s/cm5, 95% confidence interval 34 to 100, p = 0.005) at 48 hours. Patients in the iNO group used fewer systemic vasoactive drugs.(mean 2.1 +/- 0.14 vs 2.6 +/- 0.16, p = 0.046) and had a shorter intensive care unit stay (median 2 days, interquartile range 0.25, vs median 3 days, interquartile range 7, p = 0.02). In conclusion, iNO immediately after surgery in patients with mitral stenosis and severe pulmonary hypertension improves hemodynamics and may have short-term clinical benefits. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:1040-1045)
Resumo:
Background-Although routinely administered, definitive evidence for the benefits of prophylactic antibiotics before the implantation of permanent pacemakers and implantable cardioverter-defibrillators from a large double-blinded placebo-controlled trial is lacking. The purpose of this study was to determine whether prophylactic antibiotic administration reduces the incidence of infection related to device implantation. Methods and Results-This double blinded study included 1000 consecutive patients who presented for primary device (Pacemaker and implantable cardioverter-defibrillators) implantation or generator replacement randomized in a 1:1 fashion to prophylactic antibiotics or placebo. Intravenous administration of I g of cefazolin (group 1) or placebo (group 2) was done immediately before the procedure. Follow-up was performed 10 days, 1, 3, and 6 months after discharge. The primary end point was any evidence of infection at the surgical incision (pulse generator pocket), or systemic infection related to be procedure. The safety committee interrupted the trial after 649 patients were enrolled due to a significant difference in favor of the antibiotic arm (group 1: 2 of 314 infected patients-0.63%; group 11: 11 of 335 to 3.28%; RR=0.19; P=0.016). The following risk factors were positively correlated with infection by univariate analysis: nonuse of preventive antibiotic (P=0.016); implant procedures (versus generator replacement: P=0.02); presence of postoperative hematoma (P=0.03) and procedure duration (P=0.009). Multivariable analysis identified nonuse of antibiotic (P=0.037) and postoperative hematoma (P=0.023) as independent predictors of infection. Conclusions-Anti biotic prophylaxis significantly reduces infectious complications in patients undergoing implantation of pacemakers or cardioverter-defibrillators. (Circ Arrhythmia Electrophysiol. 2009;2:29-34.)
Resumo:
Conclusion: The cochlear implant was beneficial as an attempt to restore hearing and improve communication abilities in this patient with profound sensorineural hearing loss secondary to Susac syndrome. Objective: To report the audiological outcomes of cochlear implantation (CI) in a young woman with Susac syndrome after a 6-month follow-up period. Susac syndrome is a rare disorder. It is clinically characterized by a typical triad of sensorineural deafness, encephalopathy, and visual defect, due to microangiopathy involving the brain, inner ear, and retina. Methods: This was a retrospective review of a case at a tertiary referral center. After diagnosis, the patient was evaluated by a multidisciplinary team and received a cochlear implant in her right ear. Results: The patient achieved 100% open-set sentence recognition in noise conditions and 92% monosyllable and 68% medial consonant recognition in quiet conditions after 6 months of implant use. She reported the use of the telephone 3 months after activation.
Resumo:
Objective: To determine the effects of melatonin on rat endometrium morphology and embryo implantation. Design: Experimental study. Setting: Federal University of Sao Paulo, Brazil. Animal(s): Forty female rats. Intervention(s): GI: control, GII: sham-operated, GIII: pinealectomized, and GIV: pinealectomized rats that received melatonin during 3 months. The GI, GII, and Gin groups received the vehicle of melatonin (NaCl + ethanol). At the end of the treatment, the animals were killed during the estrous phase; the uterus was removed for morphometric analysis. Urine was collected for 6-sulfatoxymelatonin. Blood was collected for estrogen (E) and progesterone (P) level determinations. In a second experiment, female rats were used to evaluate the endometrial embryo implantation. Main Outcome Measure(s): Endometrial morphology and embryo implantation. Result(s): Gin presented the highest values for endometrial area and thickness index, number of endometrial glands, and eosinophils. The number of vessels of groups I, II, and IV was fewer than that of Gin. The highest number of eosinophils was detected in Gin in comparison to other groups. The implantation rate in Gin was the lowest of all groups. This implantation rate was significantly increased and restored toward normal in GIV. Conclusion(s): Our data suggested that, in nonphotoperiodic animals such as rats, melatonin may positively affect the endometrial morphology and improve embryo implantation.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
Our purpose was to retrospectively compare controlled ovarian stimulation(COH) in IVF cycles with administration of hCG on the day of menses (D1-hCG) with women not receiving hCG at day 1 of menses (Control). Data on maternal age, endocrine profile, amount of rFSH required, embryo characteristics, implantation and pregnancy rates were recorded for comparison between D1-hCG (n = 36) and Control (n = 64). Dose of rFSH required to accomplish COH was significantly lower in D1-hCG. Following ICSI, more top-quality embryos were available for transfer per patient in the D1-hCG and biochemical pregnancy rates per transfer were significantly higher in the D1-hCG. Significantly higher implantation and on-going pregnancy rates per embryo transfer were observed in D1-hCG (64%) compared to Control (41%). Administration of D1-hCG prior to COH reduces rFSH use and enhances oocyte developmental competence to obtain top quality embryos, and improves implantation and on-going pregnancy rates. At present it is not clear if the benefit is related to producing an embryo that more likely to implant or a more receptive uterus, or merely fortuitous and related to the relatively small power of the study.
Resumo:
Background: The incidence of venous lesions following transvenous cardiac device implantation is high. Previous implantation of temporary leads ipsilateral to the permanent devices, and a depressed left ventricular ejection fraction have been associated with an increased risk of venous lesions, though the effects of preventive strategies remain controversial. This randomized trial examined the effects of warfarin in the prevention of these complications in high-risk patients. Method: Between February 2004 and September 2007, we studied 101 adults who underwent a first cardiac device implantation, and who had a left ventricular ejection fraction <= 0.40, or a temporary pacing system ipsilateral to the permanent implant, or both. After device implantation, the patients were randomly assigned to warfarin to a target international normalized ratio of 2.0-3.5, or to placebo. Clinical and laboratory evaluations were performed regularly up to 6 months postimplant. Venous lesions were detected at 6 months by digital subtraction venography. Results: Venous obstructions of various degrees were observed in 46 of the 92 patients (50.0%) who underwent venography. The frequency of venous obstructions was 60.4% in the placebo, versus 38.6% in the warfarin group (P = 0.018), corresponding to an absolute risk reduction of 22% (relative risk = 0.63; 95% confidence interval = 0.013-0.42). Conclusions: Warfarin prophylaxis lowered the frequency of venous lesions after transvenous devices implantation in high-risk patients. (PACE 2009; 32:S247-S251)
Resumo:
Comparative studies between 5 French guiding catheter and others of larger size using the transfemoral approach to coronary stenting have not been described. Coronary stent implantation was performed in 90 patients in a randomized trial. The primary end-point was to compare the incidence of successful uncomplicated stent implantation per lesion with the 5F and 7F guiding catheters. Patients were excluded for excessive vessel tortuosity or anticipated need for equipment not fitting through a 5 catheter. Baseline characteristics and the use of direct stenting did not differ between the two groups. The primary success rate was 97.8% per patient in both groups and 98% per lesion in the 5 French and 97.9% in the 7 French. Guiding catheter change was necessary in 1 patient in each group to successfully complete the procedure in both groups. The amount of contrast used was 63 +/- 27.3 mL in the 5 French and 76 +/- 25 mL in the 7 French groups (P < 0.05). Vascular complications and blood transfusions occurred somewhat more frequently in the 7 French group (P = 0.058). The manual compression time after sheath removal was 5.1 +/- 2.0 min and 8.0 +/- 4.3 min, respectively, in the 5 and 7 French groups (P < 0.01). In conclusion, the 5 French guiding catheters showed a similar success rate with coronary stenting when compared to the 7 French, but the amount of contrast used and manual compression time after sheath removal, as well as the rate of vascular and bleeding complications, were reduced in the 5 French group.
Resumo:
We investigated whether there is an association between anxiety disorders and mitral valve prolapse. We compared mitral valve prolapse prevalence in individuals with panic disorder (n=41), social anxiety disorder (n=89) and in healthy controls (n=102) in an attempt to overcome the biases of previous studies. Our results show no associations between panic disorder or social anxiety disorder and mitral valve prolapse, regardless of the diagnostic criteria employed, and that the relationship between these conditions seems not to be clinically relevant.
Resumo:
The aim of this study was to evaluate the efficiency of trypsin treatment on the inactivation of bovine herpesvirus type 1 (BoHV-1) on in vitro produced by fertilization and artificially infected bovine embryos. Bovine embryos on day 7 were exposed with 10 mu l of BoHV-1, Los Angeles strain 10(7.5) TCID. These embryos and control embryos were divided in two groups: submitted to the sequential washes or to the trypsin treatment according to the International Embryo Transfer Society (IETS) guidelines. The embryos and the last washing drop of each group were used as inoculum to infect Madin Darby bovine kidney (MDBK) cells and submitted to nested PCR reaction using the primer that encodes the gene conserved region of virus glycoprotein gB. The data have shown that the control embryos and their last washing drop were negative. The exposed embryos that were treated with trypsin have shown positive results on the n-PCR and MDBK culture, and their last washing drop were negative. Our data have demonstrated that the trypsin treatment was not able to eliminate the BHV-1 of the embryos, suggesting an interaction between virus and embryo.