972 resultados para minimally invasive treatment
Resumo:
Objective: Our aim was to evaluate the challenges in obtaining a successful restoration of the rotation center as well as a good positioning of the acetabular component when using the minimally-invasive posterior approach for uncemented total hip replacement. Methods: In a comparative non-random prospective study, 64 adult patients underwent elective total hip arthroplasty using the minimally-invasive posterior approach performed by one single surgeon, All patients included in this study had a superior and lateral migration of the rotation center of the hip in comparison to the normal contralateral hip. Patients were excluded from the study if they presented the following: diagnosis of femoral neck fracture, displasic hip types 2, 3 and 4 (Crowe`s classification), osteoarthritis of the contralateral hip. Of the 64 patients in the study, 39 had a radiographic pre-op acetabular size planning equal or less than 50 mm and 25 patients had a radiographic pre-op acetabular size planning equal or more than 52 mm. We considered a good result the following goals: acetabular bend between 35 and 50 degrees, acetabular size according to the pre-op estimative with full contact in the three zones of DeLee-Charnley, a lower medial and vertical positioning of the rotation center in comparison with the pre-op values and a final limb discrepancy lower than 10 mm. Results: A better restoration of the rotation center, as well as, excellent acetabular positioning was found in patients with smaller acetabular size (equal or less than 50), p=0, 04. We must draw attention to two risks when using the minimally-invasive posterior approach: a vertical acetabular position and a lateral position of the acetabular component increasing the risk of a poor contact in the zone 1 due to an insufficient reaming of the medial acetabular host bone. Conclusion: We propose standard surgical approaches in patients with larger anatomical measurements (acetabular planning size more than 50).
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus carinatum (PC) is a chest deformity caused by a disproportionate growth of the costal cartilages compared to the bony thoracic skeleton, pulling the sternum towards, which leads to its protrusion. There has been a growing interest on using the ‘reversed Nuss’ technique as minimally invasive procedure for PC surgical correction. A corrective bar is introduced between the skin and the thoracic cage and positioned on top of the sternum highest protrusion area for continuous pressure. Then, it is fixed to the ribs and kept implanted for about 2–3 years. The purpose of this work was to (a) assess the stresses distribution on the thoracic cage that arise from the procedure, and (b) investigate the impact of different positioning of the corrective bar along the sternum. The higher stresses were generated on the 4th, 5th and 6th ribs backend, supporting the hypothesis of pectus deformities correction-induced scoliosis. The different bar positioning originated different stresses on the ribs’ backend. The bar position that led to lower stresses generated on the ribs backend was the one that also led to the smallest sternum displacement. However, this may be preferred, as the risk of induced scoliosis is lowered.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Despite advertising for NOTES in 2009, single trocart laparoscopic surgery is about to become a new standard in selected indications. As other important topics, the limits of oncological surgery are extended due to a systematic multidisciplinary approach. To discuss every publication would be difficult and our review will focus on a selected number of papers of importance for daily practice. As examples, the management of acute calculous cholecystitis, gastro-esophageal reflux, inguinal and incisional hernia repair as well as colorectal surgery are presented.
Resumo:
Purpose: To assess the clinical outcome of patients who were subjected to long-axis sacroplasty as first line treatment for sacral insufficiency fractures. Methods and materials: Nineteen patients with unilateral (n = 3) or bilateral (n = 16) sacral fractures were involved. Under local anaesthesia, each patient was subjected to CT guided sacroplasty using the long-axis approach through a single entry point. An average of 6 ml of PMMA was delivered along the path of each sacral fracture. For each individual patient, the VAS pain score before sacroplasty and at 1, 4, 24, and 48 weeks after the procedure was obtained. Furthermore, the use of analgesics (narcotic/non-narcotic) along with the evolution of post interventional patient mobility before and after sacroplasty was also recorded. Results: The mean pre-procedure VAS score was 8 ± 1.9. This has rapidly declined in the first week after the procedure (mean 4 ± 1.5) followed by gradual decrease along the rest of follow-up period at 4 weeks (mean 3 ± 1.2), 24 weeks (mean 2 ± 1.3), and 48 weeks (mean 1.3 ± 1.4), respectively. Eleven (58%) patients were under narcotic analgesia before sacroplasty, whereas, 8 (42%) patients were using non-narcotics. Corresponding values after the procedure were 2/19 (10%) (narcotic) and 10/19 53% (non-narcotic). Seven (37%) patients did not address post-procedure analgesic use. The evolution of post interventional mobility was favourable in the study group since they revealed a significant improvement in their mobility point scale. Conclusion: Long-axis percutaneous sacroplasty is a suitable minimally invasive treatment option for patients who present with sacral insufficiency fractures. Future studies with larger patient number are warranted to grasp any potential limitations of this therapeutic approach.
Resumo:
Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.
Resumo:
INTRODUCTION: The purpose of our study was to retrospectively evaluate the clinical and radiological results of subtrochanteric fractures treated with a long gamma nail (LGN). The LGN has been the implant of choice at our level-1 trauma center since 1992. MATERIALS AND METHODS: Over a period of 7 years, we have treated 90 consecutive patients with subtrochanteric fractures. In order to evaluate the clinical and radiological outcomes, we reviewed the clinical and radiographic charts of these patients followed for a mean time of 2 years (range 13-36 months). RESULTS: We found no intra- or perioperative complications nor early or late infection. Clinical and radiological union was achieved at a mean of 4.3 months in all of the patients (range 3-9 months); in 24 cases (30%) the distal locking bolts were retrieved in order to enhance callus formation and remodeling as a planned secondary surgery. Three patients (3.3%) needed unplanned secondary surgery for problems related to the nailing technique. Two mechanical failures with breakage of the nail were encountered due to proximal varus malalignment, of which one was treated with exchange nailing and grafting and the other one by removal of the broken hardware, blade-plating, and bone grafting. One fracture below a short LGN was treated by exchange nailing. CONCLUSIONS: The minimally invasive technique and simple application of the LGN lead to a low percentage of complications in these difficult fractures after a relatively short learning curve. The biomechanical properties of this implant allow early mobilization and partial weight-bearing even in patients with advanced osteoporosis.
Resumo:
There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).
Resumo:
We describe a simple method to achieve both hemostasis and stabilization of the left anterior descending coronary artery during minimally invasive coronary artery bypass grafting. This technique allows the surgeon to perform a precise anastomosis of the left internal mammary artery to the target vessel on a beating heart.
Resumo:
BACKGROUND: Minimally invasive surgery (MIS) for late-presenting congenital diaphragmatic hernia (CDH) has been described previously, but few neonatal cases of CDH have been reported. This study aimed to report the multicenter experience of these rare cases and to compare the laparoscopic and thoracoscopic approaches. METHODS: Using MIS procedures, 30 patients (16 boys and 14 girls) from nine centers underwent surgery for CDH within the first month of life, 26 before day 5. Only one patient had associated malformations. There were 10 preterm patients (32-36 weeks of gestational age). Their weight at birth ranged from 1,800 to 3,800 g, with three patients weighing less than 2,600 g. Of the 30 patients, 18 were intubated at birth. RESULTS: The MIS procedures were performed in 18 cases by a thoracoscopic approach and in 12 cases by a laparoscopic approach. No severe complication was observed. For 20 patients, reduction of the intrathoracic contents was achieved easily with 15 thoracoscopies and 5 laparoscopies. In six cases, the reduction was difficult, proving to be impossible for the four remaining patients: one treated with thoracoscopy and three with laparoscopy. The reasons for the inability to reduce the thoracic contents were difficulty of liver mobilization (1 left CDH and 2 right CDH) and the presence of a dilated stomach in the thorax. Reductions were easier for cases of wide diaphragmatic defects using thoracoscopy. There were 10 conversions (5 laparoscopies and 5 thoracoscopies). The reported reasons for conversion were inability to reduce (n = 4), need for a patch (n = 5), lack of adequate vision (n = 4), narrow working space (n = 1), associated bowel malrotation (n = 1), and an anesthetic problem (n = 1). Five defects were too large for direct closure and had to be closed with a patch. Four required conversion, with one performed through video-assisted thoracic surgery. The recurrences were detected after two primer thoracoscopic closures, one of which was managed by successful reoperation using thoracoscopy. CONCLUSIONS: In the neonatal period, CDH can be safely closed using MIS procedures. The overall success rate in this study was 67%. The indication for MIS is not related to weeks of gestational age, to weight at birth (if >2,600 g), or to the extent of the immediate neonatal care. Patients with no associated anomaly who are hemodynamically stabilized can benefit from MIS procedures. Reduction of the herniated organs is easier using thoracoscopy. Right CDH, liver lobe herniation, and the need for a patch closure are the most frequent reasons for conversion.
Resumo:
Thyroid and parathyroid surgery takes an important place in general surgery. Preservation of essential cervical structures and cosmetic of outcomes of cervical incisions are major concern. Several minimally invasive strategies have been developed recently but their acceptance in the surgical community is low. Their main advantages are focused tissue dissection and improved cosmetics. In this review, management and surgical indications of thyroid nodules and parathyroid adenomas are discussed. The various minimally invasive techniques are described and their current indications are reviewed.
Resumo:
BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.