954 resultados para mini-implants


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of this study is to evaluate by histometric and immunohistochemistry analysis the effects of antimicrobial photodynamic therapy (aPDT) in alveolar prior to placement of mini-implants in animals with or without induced periodontal disease. Material and method: Thirty-two rats were used. Periodontal disease (PD) was induced by ligature in the lower left first molar. After 7 days of PD evolution, it was performed removal of the ligature and extraction of the left lower first molars in all animals. Thus, animals were divided into 2 groups (n=16) according to the treatments in the dental alveolus before immediate implant installation: MD (control) : mechanical debridement (MD), irrigation with 1 ml of saline solution followed by implant installation; aPDT- MD, irrigation with 1 ml of Toluidine Blue-O and low intensity laser (LLLT) and implant installation. Eight animals from each group were euthanized at 15 and 30 days after the installation of mini-implants. Specimens were processed for histologic, immunohistochemical and histometric analysis. The histometric data were processed for statistical analysis (Kruskall-Wallis and Dunn test; p <0.05). Result: In treatment analysis, results indicated that there was a greater BIC in implants installed in uncontaminated alveolus treated with a PDT ( p<0,05) and greater imuno-reactivity to OPG in bone issue treated with aPDT. Conclusion: The aPDT proved to be effective in bone loss control in no contaminated area and it has increased the bone loss and metabolic activity in alveolus irradiated prior to implant installation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Open bite has fascinated Orthodontics due to the difficulties regarding its treatment and maintenance of results. This anomaly has distinct characteristics that, in addition to the complexity of multiple etiological factors, have aesthetic and functional consequences. Within this etiological context, several types of mechanics have been used in open bite treatment, such as palatal crib, orthopedic forces, occlusal adjustment, orthodontic camouflage with or without extraction, orthodontic intervention using mini-implants or mini-plates, and even orthognathic surgery. An accurate diagnosis and etiological determination are always the best guides to establish the objectives and the ideal treatment plan for such a malocclusion. This report describes two cases of open bite. At the end of the treatment, both patients had their canines and molars in Class I occlusion, normal overjet and overbite, and stability during the posttreatment period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uma ancoragem eficiente é um factor de extrema importância em Ortodontia. Perante a relevância deste assunto e sendo ainda um desafio para muitos ortodontistas, este trabalho tem como objetivo realizar uma revisão bibliográfica sobre dispositivos de ancoragem, especificamente mini-implantes e mini-placas, entendendo que os mesmos surgiram como auxiliares importantes no tratamento ortodôntico, com a finalidade de relacionar os tipos, indicações, aplicações clínicas, locais de instalação, vantagens, possíveis complicações na sua utilização e cuidados a serem tomados. Alta versatilidade de aplicação clínica, eliminação de movimentos indesejáveis dos dentes pilares, movimentos precisos, movimentos mais rápidos, redução de custos, processo cirúrgico simples e pouco invasivo, substituição de aparelhos extraorais, tamanho reduzido e capacidade de suportar de imediato forças ortodônticas pesadas, são algumas das vantagens na utilização dos mini-implantes e mini-placas que fazem com que a ancoragem óssea absoluta obtida através do seu uso crie melhores condições na obtenção dos objetivos propostos no tratamento ortodôntico com aparatologia fixa.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is likely that effective application of cell-laden implants for cartilage defects depends on retention of implanted cells and interaction between implanted and host cells. The objectives of this study were to characterize stratified cartilaginous constructs seeded sequentially with superficial (S) and middle (M) chondrocyte subpopulations labelled with fluorescent cell tracking dye PKH26 (*) and determine the degree to which these stratified cartilaginous constructs maintain their architecture in vivo after implantation in mini-pigs for 1 week. Alginate-recovered cells were seeded sequentially to form stratified S*/M (only S cells labelled) and S*/M* (both S and M cells labelled) constructs. Full-thickness defects (4 mm diameter) were created in the patellofemoral groove of adult Yucatan mini-pigs and filled with portions of constructs or left empty. Constructs were characterized biochemically, histologically, and biomechanically, and stratification visualized and quantified, before and after implant. After 1 week, animals were sacrificed and implants retrieved. After 1 week in vivo, glycosaminoglycan and collagen content of constructs remained similar to that at implant, whereas DNA content increased. Histological analyses revealed features of an early repair response, with defects filled with tissues containing little matrix and abundant cells. Some implanted (PKH26-labeled) cells persisted in the defects, although constructs did not maintain a stratified organization. Of the labelled cells, 126 +/- 38% and 32 +/- 8% in S*/M and S*/M* constructs, respectively, were recovered. Distribution of labelled cells indicated interactions between implanted and host cells. Longer-term in vivo studies will be useful in determining whether implanted cells are sufficient to have a positive effect in repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Limited range of finger motion is a frequent complication after plate fixation of phalangeal fractures. The purpose of this study was to evaluate the results of plate fixation of extra-articular fractures of the proximal phalanx using current low-profile mini-fragment-systems. METHODS From 2006 to 2012, 32 patients with 36 extra-articular fractures of the proximal phalanx of the triphalangeal fingers were treated with open reduction and plate fixation (ORPF) using 1.2 and 1.5 mm mini-fragment systems. Patients presenting with open fractures grade 2 and 3 or relevant laceration of adjacent structures were excluded from the study. We retrospectively evaluated the rate of mal-union or non-union after ORPF, the need for revision surgery, for plate removal, and for tenolysis. Data were analyzed for further complications with regard to infections or complex regional pain syndrome (CRPS). RESULTS No infections were noted. Five patients developed transient symptoms of CRPS. Six weeks postoperatively, total active finger motion (TAM) averaged 183°, and all 32 patients underwent formal hand therapy. At the latest follow-up or at the time of plate removal, respectively, the mean TAM improved to 213°. Extension lag of proximal interphalangeal joints was found in 67 % of all fractured fingers. Secondary surgery was necessary in 14 of 32 patients (2 corrective osteotomies, 12 plate removals including 7 procedures explicitly because of reduced mobility). CONCLUSIONS Despite of new implant designs significant problems persist. Adhesions of extensor tendons leading to limited range of finger motion are still the most frequent complications after ORPF of proximal phalangeal fractures, even in absence of significant soft-tissue damage. LEVEL OF EVIDENCE Therapeutic, Retrospective, Level IV.