933 resultados para mesh: Neurophysiology
Resumo:
Context: In the past 50 years, the use of prosthetic mesh in surgery has dramatically¦changed the management of primary, as well as incisional hernias. Currently, there¦are a large number of different mesh brands and no consensus on the best material,¦nor the best mesh implantation technique to use. The purpose of this study is to¦illustrate the adverse effects of intraperitoneal onlay mesh used for incisional¦hernia repair encountered in patients treated at CHUV for complications after¦incisional hernia repair.¦Materials & Methods: This work is an observational retrospective study. A PubMed¦search and a systematic review of literature were performed. Thereafter, the medical¦records of 22 patients who presented with pain, abdominal discomfort, ileus, fistula,¦abscess, seroma, mesh infection or recurrent incisional hernia after a laparoscopic or¦open repair with intra-abdominal mesh were reviewed.¦Results: Twenty-two persons were reoperated for complications after incisional¦hernia repair with a prosthetic mesh. Ten were male and twelve female, with a¦median age of 58,6 years (range 24-82). Mesh placement was performed by a¦laparoscopic approach in nine patients and by open approach in thirteen others.¦Eight different mesh brands were found (Ultrapro®, Mersilene®, Parietex Composite®,¦Proceed®, DynaMesh®, Gore® DualMesh®, Permacol®, Titanium Metals UK Ltd®).¦Mean time from implantation and reoperation for complication was 34.2 months¦(range 1-147). In our sample of 22 patients, 21 (96%) presented mesh adhesion and¦15 (68%) presented hernia recurrence. Others complications like mesh shrinkage,¦mesh migration, nerve entrapment, seroma, fistula and abscess were also evaluated.¦Conclusion: The majority of articles deal with complications induced by¦intraperitoneal prosthetic mesh, but the effectiveness of mesh has been studied¦mostly on experimental models. Actually and as shown in the present study,¦intraperitoneal mesh placement was associated with severe complications witch may¦potentially be life threatening. In our opinion, intraperitoneal mesh placement should¦only be reserved in exceptional situations, when the modified Rives-Stoppa could not¦be achieved and when tissues covering the mesh are insufficient.
Resumo:
Totally extraperitoneal laparoscopic hernia repair is an efficient but technically demanding procedure. As mechanisms of hernia recurrence may be related to these technical difficulties, we have modified a previously described double-mesh technique in an effort to simplify the procedure. Extraperitoneal laparoscopic hernia repairs were performed in 82 male and 17 female patients having inguinal, femoral, and recurrent bilateral hernias. A standard propylene mesh measuring 15 x 15 cm was cut into two pieces of 4 x 15 cm and 11 x 15 cm. The smaller mesh was placed over both inguinal rings without splitting. The larger mesh was then inserted over the first mesh and stapled to low-risk zones, reinforcing the large-vessel area and the nerve transition zone. The mean procedure duration was 60 minutes for unilateral and 100 minutes for bilateral hernia repair. Patients were discharged from the hospital within 48 hours. The mean postoperative follow-up was 22 months, with no recurrences, neuralgia, or bleeding complications. Over a 2-year period, this technique was found to be satisfactory without recurrences or significant complications. In our hands, this technique was easier to perform: it allows for a less than perfect positioning of the meshes and avoids most of the stapling to crucial zones.
Resumo:
The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
Seeing seems effortless, despite the need to segregate and integrate visual information that varies in quality, quantity, and location. The extent to which seeing passively recapitulates the external world is challenged by phenomena such as illusory contours, an example of visual completion whereby borders are perceived despite their physical absence in the image. Instead, visual completion and seeing are increasingly conceived as active processes, dependent on information exchange across neural populations. How this is instantiated in the brain remains controversial. Divergent models emanate from single-unit and population-level electrophysiology, neuroimaging, and neurostimulation studies. We reconcile discrepant findings from different methods and disciplines, and underscore the importance of taking into account spatiotemporal brain dynamics in generating models of brain function and perception.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
The Editors welcome topical correspondence from readers relating to articles published in the Journal. Responses should be sent electronically via the BJS website (www.bjs.co.uk). All letters will be reviewed and, if approved, appear on the website. A selection of these will be edited and published in the Journal. Letters must be no more than 250 words in length.
Resumo:
The saphenous vein is the conduit of choice in bypass graft procedures. Haemodynamic factors play a major role in the development of intimal hyperplasia (IH), and subsequent bypass failure. To evaluate the potential protective effect of external reinforcement on such a failure, we developed an ex vivo model for the perfusion of segments of human saphenous veins under arterial shear stress. In veins submitted to pulsatile high pressure (mean pressure at 100 mmHg) for 3 or 7 days, the use of an external macroporous polyester mesh 1) prevented the dilatation of the vessel, 2) decreased the development of IH, 3) reduced the apoptosis of smooth muscle cells, and the subsequent fibrosis of the media layer, 4) prevented the remodelling of extracellular matrix through the up-regulation of matrix metalloproteinases (MMP-2, MMP-9) and plasminogen activator type I. The data show that, in an experimental ex vivo setting, an external scaffold decreases IH and maintains the integrity of veins exposed to arterial pressure, via increase in shear stress and decrease wall tension, that likely contribute to trigger selective molecular and cellular changes.
Resumo:
Implantación de un modelo de red abierta tipo mesh para propagar el acceso libre al servicio de biblioteca y contenidos abiertos.
Resumo:
Over the past two decades, electrophysiology has undergone unprecedented changes thanks to technical improvements, which simplify measurement and analysis and allow more compact data storage. This book covers in detail the spectrum of electrophysiology applications in patients with disorders of consciousness. Its content spans from clinical aspects of the management of subjects in the intensive care unit, including EEG, evoked potentials and related implications in terms of prognosis and patient management to research applications in subjects with ongoing consciousness impairment. While the first section provides up-to-date information for the interested clinician, the second part highlights the latest developments in this exciting field. The book comprehensively combines clinical and research information related to neurophysiology in disorder-of- consciousness patients, making it an easily accessible reference for neuro-ICU specialists, epileptologists and clinical neurophysiologists as well as researchers utilizing EEG and event-related potentials.
Resumo:
In this article, a new technique for grooming low-speed traffic demands into high-speed optical routes is proposed. This enhancement allows a transparent wavelength-routing switch (WRS) to aggregate traffic en route over existing optical routes without incurring expensive optical-electrical-optical (OEO) conversions. This implies that: a) an optical route may be considered as having more than one ingress node (all inline) and, b) traffic demands can partially use optical routes to reach their destination. The proposed optical routes are named "lighttours" since the traffic originating from different sources can be forwarded together in a single optical route, i.e., as taking a "tour" over different sources towards the same destination. The possibility of creating lighttours is the consequence of a novel WRS architecture proposed in this article, named "enhanced grooming" (G+). The ability to groom more traffic in the middle of a lighttour is achieved with the support of a simple optical device named lambda-monitor (previously introduced in the RingO project). In this article, we present the new WRS architecture and its advantages. To compare the advantages of lighttours with respect to classical lightpaths, an integer linear programming (ILP) model is proposed for the well-known multilayer problem: traffic grooming, routing and wavelength assignment The ILP model may be used for several objectives. However, this article focuses on two objectives: maximizing the network throughput, and minimizing the number of optical-electro-optical conversions used. Experiments show that G+ can route all the traffic using only half of the total OEO conversions needed by classical grooming. An heuristic is also proposed, aiming at achieving near optimal results in polynomial time
Resumo:
En el projecte ens centrarem en el funcionament de les Xarxes mallades sense fils, es fa una breu explicació de les xarxes Ad-hoc, ja que aquestes formen un part important dintre d’una xarxa Mesh. S’explicaran diversos protocols d’enrutament com ara BATMAN, AODV, 802.11s i OLSR. Aquest últim és el que utilitzarem per a la configuració de la xarxa que realitzarem. S’explicarà el tipus de paquets que s’envien entre els nodes perquè el funcionament de la xarxa sigui òptim i tots els clients puguin tenir-hi accés i estiguin connectats entre ells. Al finalitzar l’estudi teòric d’aquest tipus de xarxa i veure les seves avantatges i desavantatges respecte altres tipus de xarxes sense fils, es muntaran dos petites xarxa. Per a muntar-les utilitzarem de Punts d’Accés els nodes Ubuquiti Nanoestation LocoM2. Una de les xarxes serà al poble Bellcaire d’Urgell, on és connectaran tres cases, on només una te accés a Internet i els nodes estaran connectats en línia, es a dir, del Node1 – Node2 – Node3. La segona serà a una casa de Barcelona on mitjançant els tres nodes obtindrem una connexió d’Internet a tota la casa, en aquest cas els tres nodes estaran connectats els tres formant un cercle, es a dir, Node1-Node2-Node3-Node1. Finalment, és mirarà una proposta de futur, on es parlaria amb l’Ajuntament del poble on s’ha fet la primera proba per realitzar una Xarxa mallada sense fils a tots els llocs públics del poble.
Surgical treatment of subcostal incisional hernia with polypropylene mesh - analysis of late results
Resumo:
OBJECTIVE: To evaluate the results of subcostal incisional hernia repair using polypropylene mesh, the technical aspects of musculo-aponeurotic reconstruction, routine fixation of supra-aponeurotic mesh and follow-up for five years.METHODS: We conducted a retrospective study that assessed 24 patients undergoing subcostal incisional hernia repair with use of polypropylene mesh; 15 patients (62.5%) were female; ages ranged from 33 to 82, and 79.1% had comorbidities.RESULTS: Early complications: three cases (12.5%) of wound infection, three cases (12.5%) of seroma, one case (4.1%) of hematoma; and one case (4.1%) of wound dehiscence. Late complications occurred in one case (4.1%) of hernia recurrence attributed to technical failure in the fixation of the mesh and in one case (4.1%) of chronic pain. There were no cases of exposure or rejection of the mesh.CONCLUSION: The subcostal incisional hernia, though not very relevant, requires adequate surgical treatment. Its surgical correction involves rebuilding the muscle-aponeurotic defect, supra-aponeurotic fixation of polypropylene mesh, with less complexity and lower rates of complications and recurrences.