864 resultados para membrane-oxygenation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acute cardiovascular dysfunction occurs perioperatively in more than 20% of cardiosurgical patients, yet current acute heart failure (HF) classification is not applicable to this period. Indicators of major perioperative risk include unstable coronary syndromes, decompensated HF, significant arrhythmias and valvular disease. Clinical risk factors include history of heart disease, compensated HF, cerebrovascular disease, presence of diabetes mellitus, renal insufficiency and high-risk surgery. EuroSCORE reliably predicts perioperative cardiovascular alteration in patients aged less than 80 years. Preoperative B-type natriuretic peptide level is an additional risk stratification factor. Aggressively preserving heart function during cardiosurgery is a major goal. Volatile anaesthetics and levosimendan seem to be promising cardioprotective agents, but large trials are still needed to assess the best cardioprotective agent(s) and optimal protocol(s). The aim of monitoring is early detection and assessment of mechanisms of perioperative cardiovascular dysfunction. Ideally, volume status should be assessed by 'dynamic' measurement of haemodynamic parameters. Assess heart function first by echocardiography, then using a pulmonary artery catheter (especially in right heart dysfunction). If volaemia and heart function are in the normal range, cardiovascular dysfunction is very likely related to vascular dysfunction. In treating myocardial dysfunction, consider the following options, either alone or in combination: low-to-moderate doses of dobutamine and epinephrine, milrinone or levosimendan. In vasoplegia-induced hypotension, use norepinephrine to maintain adequate perfusion pressure. Exclude hypovolaemia in patients under vasopressors, through repeated volume assessments. Optimal perioperative use of inotropes/vasopressors in cardiosurgery remains controversial, and further large multinational studies are needed. Cardiosurgical perioperative classification of cardiac impairment should be based on time of occurrence (precardiotomy, failure to wean, postcardiotomy) and haemodynamic severity of the patient's condition (crash and burn, deteriorating fast, stable but inotrope dependent). In heart dysfunction with suspected coronary hypoperfusion, an intra-aortic balloon pump is highly recommended. A ventricular assist device should be considered before end organ dysfunction becomes evident. Extra-corporeal membrane oxygenation is an elegant solution as a bridge to recovery and/or decision making. This paper offers practical recommendations for management of perioperative HF in cardiosurgery based on European experts' opinion. It also emphasizes the need for large surveys and studies to assess the optimal way to manage perioperative HF in cardiac surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this investigation was to improve the hemodynamics during venoarterial bypass by remote decompression of the left ventricle (LV). METHODS: Venoarterial bypass was established in 5 bovine experiments (69+/-10 kg) by the transjugular insertion of a self-expanding cannula (smartcanula) with return through a carotid artery. Cardiogenic shock was simulated with ventricular fibrillation induced by an external stimulator. Left ventricular decompression was achieved by switching to transfemoral drainage of the pulmonary artery (PA) with a long self-expanding cannula. RESULTS: Initial pump flow was 4.7+/-0.9 l/min and the aortic pressure accounted for 75+/-21 mmHg. After induction of ventricular fibrillation, the pump flow dropped after 11+/-8 min to 2.5+/-0.1 l/min. Transfemoral decompression increased the pump flow to 5.6+/-0.7 l/min, while the RV pressure decreased from 27+/-9 to 3+/-5 mmHg, the PA pressure decreased from 29+/-7 to 5+/-4 mmHg, the LV pressure decreased from 29+/-6 to 7+/-2 mmHg, and the aortic pressure increased from 31+/-3 to 47+/-11 mmHg. CONCLUSIONS: Remote drainage of the pulmonary artery during venoarterial bypass allows for effective decompression of the left ventricle and provides superior hemodynamics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Invasive fungal infection (IFI) is associated with high mortality after heart transplantation (HTx). After two undiagnosed fatal cases of early disseminated fungal infections in our heart transplant program, a retrospective analysis was conducted to identify risk factors for the development of IFI and implement a new antifungal prophylaxis policy. METHODS: Clinical characteristics of HTx recipients hospitalized in our center (2004-2010) were recorded (Period 1), and risk factors associated with IFI were investigated using Cox regression analysis. From October 2010 to October 2012 (Period 2), targeted caspofungin prophylaxis was administered to all recipients at high risk for IFI, based on the results of the Period 1 analysis. RESULTS: During Period 1, 10% (6/59) of the patients developed IFI at a median onset of 9 days after transplantation. By multivariate analysis, the use of posttransplant extracorporeal membrane oxygenation (ECMO) was the strongest predictor for fungal infection (OR, 29.93; 95% CI, 1.51-592.57, P=0.03), whereas renal replacement therapy (RRT) and Aspergillus colonization were significant predictors only by univariate analysis. During Period 2, only 4% (1/26) of the patients developed IFI. In patients at high risk for IFI, antifungal prophylaxis was administered to 17% (4/23) in Period 1 versus 100% (13/13) in Period 2 (P<0.01). By survival analysis, antifungal prophylaxis was associated with a reduction in 90-day IFI incidence (HR, 0.14; 95% CI, 0.03-0.84, P=0.03) and 30-day mortality (HR, 0.25; 95% CI, 0.09-0.8, P=0.02). CONCLUSION: Extracorporeal membrane oxygenation was identified an important risk factor for IFI after HTx, and its use may require targeted administration of antifungal prophylaxis in the immediate posttransplant period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Treatment of congenital diaphragmatic hernia (CDH) challenges obstetricians, pediatric surgeons, and neonatologists. Persistent pulmonary hypertension (PPHT) associated with lung hypoplasia in CDH leads to a high mortality rate at birth. PPHT is principally due to an increased muscularization of the arterioles. Management of CDH has been greatly improved by the introduction of prenatal surgical intervention with tracheal obstruction (TO) and by more appropriate postnatal care. TO appears to accelerate fetal lung growth and to increase the number of capillary vessels and alveoli. Improvement of postnatal care over the last years is mainly due to the avoidance of lung injury by applying low peak inflation pressure during ventilation. The benefits of other drugs or technical improvements such as the use of inhaled nitric oxide or extracorporeal membrane oxygenation (ECMO) are still being debated and no single strategy is accepted worldwide. Despite intensive clinical and experimental research, the treatment of newborn with CDH remains difficult.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Extracorporeal life support systems (ECLS) have become common in cardiothoracic surgery, but are still "Terra Incognita" in other medical fields due to the fact that perfusion units are normally bound to cardiothoracic centres. The Lifebridge B2T is an ECLS that is meant to be used as an easy and fast-track extracorporeal cardiac support to provide short-term perfusion for the transport of a patient to a specialized centre. With the Lifebridge B2T it is now possible to provide extracorporeal bypass for patients in hospitals without a perfusion unit. The Lifebridge B2T was tested on three calves to analyze the handling, performance and security of this system. The Lifebridge B2T safely can be used clinically and can provide full extracorporeal support for patients in cardiac or pulmonary failure. Flows up to 3.9 +/- 0.2l/min were reached, with an inflow pressure of -103 +/- 13mmHg, using a 21Fr. BioMedicus (Medtronic, Minneapolis, MN, USA) venous cannula. The "Plug and Play" philosophy, with semi-automatic priming, integrated check-list, a long battery time of over two hours and instinctively designed user interface, makes this device very interesting for units with high-risk interventions, such as catheterisation labs. If a system is necessary in an emergency unit, the Lifebridge can provide a high security level, even in centres not acquainted with cardiopulmonary bypass.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulmonary alveolar proteinosis (PAP) is characterized by accumulation of lipoproteinaceous material in the terminal airways. Whole lung lavage (WLL) remains the gold standard treatment but may be particularly challenging in cases of severe hypoxemia. We present a 3-step strategy that was used in a patient with PAP-associated refractory hypoxemia and that combined venovenous extracorporeal membrane oxygenation (vvECMO), double-lumen orotracheal intubation, and bilateral multisegmental sequential lavage (MSL). The procedure was well tolerated and permitted weaning from the ventilator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Patients who require extracorporeal membrane oxygenation (ECMO) postsurgery for congenital heart disease (CHD) frequently experience severe bleeding episodes. Whereas recombinant-activated factor VII (rFVIIa) has proven efficacy in counteracting intractable hemorrhage in various scenarios, its use in patients on ECMO is limited by the increased risk for thrombotic events. METHODS: Between December 2004 and January 2006, ECMO was used in 10 pediatric patients following cardiac surgery, of whom seven were treated with rFVIIa because of intractable hemorrhage. Their medical records were reviewed with respect to variations in chest tube output and transfusion requirements, occlusion of or thrombus formation in the ECMO circuit and the occurrence of thromboembolic events. Outcome and rate of ECMO circuit occlusion were compared with historic controls. RESULTS: Three patients died, and four survived (none of the deaths was attributable to thrombus formation or bleeding). All patients were treated with aprotinin prior to and during rFVIIa therapy. Two patients developed an occlusion of the oxygenator, one after receiving co-medication with a FXIII concentrate, another after RBC transfusion in the ECMO system. In two patients, thrombus formation was observed in the ECMO system on inspection after discontinuation. Thromboembolic events were not observed. CONCLUSIONS: Recombinant-activated factor VII in a median dosage of 90 microg.kg(-1) was used in seven pediatric patients on ECMO. Rates of ECMO system occlusions and mortality did not differ from historic controls. Neither the reduction of chest tube output nor the blood product transfusion requirements did reach statistical significance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Posttraumatic adult respiratory distress syndrome (ARDS) still involves significant mortality, despite progress in management concepts. Current therapeutic strategies are briefly described, including kinetic therapy, high-frequency jet ventilation and extracorporeal membrane oxygenation. In addition, a spectacular case of the first successful lung transplantation for posttraumatic ARDS after failed ECMO (extracorporeal membrane oxygenation) support is reported. This young man with severe posttraumatic ARDS developed a potentially lethal bilateral pulmonary hemorrhage under treatment with ECMO, and on the basis of this bilateral pulmonary transplantation was considered to be indicated. The patient is alive and well 2 years after the procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 44-year-old male European with type I diabetes mellitus fell into diabetic ketoacidosis. In the emergency room, he developed an episode of asystole and respiratory failure requiring one cycle of cardiopulmonary resuscitation and extracorporeal membrane oxygenation (ECMO). Waking up 7 days later, he presented a bilateral complete loss of vision. Ophthalmological examination including funduscopy on days 1 and 10, after extubation, showed bilateral large round pupils non-reactive to light and a normal fundus. Neuroimaging studies, including MRI and MRA of the brain, were all within normal limits. A lumbar puncture and comprehensive serological testing excluded an infectious or rheumatic cause. An empirical high-dose intravenous steroid treatment administered for 5 days had no effect on his vision. His eye examination at 1.5 months follow-up showed a normal fundus except for progressive bilateral optic nerve disc pallor, which pointed towards the diagnosis of a posterior ischaemic optic neuropathy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Congenital diaphragmatic hernia (CDH) remains a significant cause of death in newborns. With advances in neonatal critical care and ventilation strategies, survival in the term infant now exceeds 80% in some centers. Although prematurity is a significant risk factor for morbidity and mortality in most neonatal diseases, its associated risk with infants with CDH has been described poorly. We sought to determine the impact of prematurity on survival using data from the Congenital Diaphragmatic Hernia Registry (CDHR). METHODS: Prospectively collected data from live-born infants with CDH were analyzed from the CDHR from January 1995 to July 2009. Preterm infants were defined as <37 weeks estimated gestational age at birth. Univariate and multivariate logistic regression analysis were>performed. RESULTS: During the study period, 5,069 infants with CDH were entered in the registry. Of the 5,022 infants with gestational age data, there were 3,895 term infants (77.6%) and 1,127 preterm infants (22.4%). Overall survival was 68.7%. A higher percentage of term infants were treated with extracorporeal membrane oxygenation (ECMO) (33% term vs 25.6% preterm). Preterm infants had a greater percentage of chromosomal abnormalities (4% term vs 8.1% preterm) and major cardiac anomalies (6.1% term vs 11.8% preterm). Also, a significantly higher percentage of term infants had repair of the hernia (86.3% term vs 69.4% preterm). Survival for infants that underwent repair was high in both groups (84.6% term vs 77.2% preterm). Survival decreased with decreasing gestational age (73.1% term vs 53.5% preterm). The odds ratio (OR) for death among preterm infants adjusted for patch repair, ECMO, chromosomal abnormalities, and major cardiac anomalies was OR 1.68 (95% confidence interval [CI], 1.34-2.11). CONCLUSION: Although outcomes for preterm infants are clearly worse than in the term infant, more than 50% of preterm infants still survived. Preterm infants with CDH remain a high-risk group. Although ECMO may be of limited value in the extremely premature infant with CDH, most preterm infants that live to undergo repair will survive. Prematurity should not be an independent factor in the treatment strategies of infants with CDH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Whole-body hypothermia reduced the frequency of death or moderate/severe disabilities in neonates with hypoxic-ischemic encephalopathy in a randomized, controlled multicenter trial. OBJECTIVE: Our goal was to evaluate outcomes of safety and effectiveness of hypothermia in infants up to 18 to 22 months of age. DESIGN/METHODS: A priori outcomes were evaluated between hypothermia (n = 102) and control (n = 106) groups. RESULTS: Encephalopathy attributable to causes other than hypoxia-ischemia at birth was not noted. Inotropic support (hypothermia, 59% of infants; control, 56% of infants) was similar during the 72-hour study intervention period in both groups. Need for blood transfusions (hypothermia, 24%; control, 24%), platelet transfusions (hypothermia, 20%; control, 12%), and volume expanders (hypothermia, 54%; control, 49%) was similar in the 2 groups. Among infants with persistent pulmonary hypertension (hypothermia, 25%; control, 22%), nitric-oxide use (hypothermia, 68%; control, 57%) and placement on extracorporeal membrane oxygenation (hypothermia, 4%; control, 9%) was similar between the 2 groups. Non-central nervous system organ dysfunctions occurred with similar frequency in the hypothermia (74%) and control (73%) groups. Rehospitalization occurred among 27% of the infants in the hypothermia group and 42% of infants in the control group. At 18 months, the hypothermia group had 24 deaths, 19 severe disabilities, and 2 moderate disabilities, whereas the control group had 38 deaths, 25 severe disabilities, and 1 moderate disability. Growth parameters were similar between survivors. No adverse outcomes were noted among infants receiving hypothermia with transient reduction of temperature below a target of 33.5 degrees C at initiation of cooling. There was a trend in reduction of frequency of all outcomes in the hypothermia group compared with the control group in both moderate and severe encephalopathy categories. CONCLUSIONS: Although not powered to test these secondary outcomes, whole-body hypothermia in infants with encephalopathy was safe and was associated with a consistent trend for decreasing frequency of each of the components of disability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Current guidelines for the treatment of hypothermic cardiocirculatory arrest recommend extracorporeal life support and rewarming, using cardiopulmonary bypass or extracorporeal membrane oxygenation circuits. Both have design-related shortcomings which may result in prolonged reperfusion time or insufficient oxygen delivery to vital organs. This article describes clear advantages of minimally invasive extracorporeal circulation systems during emergency extracorporeal life support in hypothermic arrest. The technique of minimally invasive extracorporeal circulation for reperfusion and rewarming is represented by the case of a 59-year-old patient in hypothermic cardiocirculatory arrest at 25.3°C core temperature, with multiple trauma. With femoro-femoral cannulation performed under sonographic and echocardiographic guidance, extracorporeal life support was initiated using a minimally invasive extracorporeal circulation system. Perfusing rhythm was restored at 28°C. During rewarming on the mobile circuit, trauma surveys were completed and the treatment initiated. Normothermic weaning was successful on the first attempt, trauma surgery was completed and the patient survived neurologically intact. For extracorporeal resuscitation from hypothermic arrest, minimally invasive extracorporeal circulation offers all the advantages of conventional cardiopulmonary bypass and extracorporeal membrane oxygenation systems without their shortcomings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014