999 resultados para método de avaliação de perdas
Resumo:
This study aims to the understanding of adolescents regarding oral health, using the Focus Group technique. The study was conducted at three public schools in the city of Araçatuba, São Paulo State, Brazil, with ten students in each. In order to conduct the focus groups, the following words, which featured high error levels, were addressed in survey questions on oral health: oral health; plaque, permanent teeth; fluoride; gum bleeds?; dental floss; transmission of cavities. During the discussions in the focus groups, it was observed that many teenagers were surprised at the situation to which they were submitted and at the topic they were discussing. The word 'oral health' was associated with the condition of cleanliness of the oral cavity, not identifying oral health as part of general health. The term 'transmission of cavities' did not have a sufficient understanding. The term 'permanent tooth' was well understood and was associated with a type of tooth that would not be replaced. The word 'fluoride' had more association with the task of cleaning than protection of the teeth. It is concluded that the use of the focus group technique is of great importance in the interpretation of the knowledge of adolescents on oral health and the appropriateness of the terminology of questionnaires on the same subject.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este trabalho tem como objetivo analisar as perdas de água no sistema de abastecimento da COSANPA que atende a demanda da Região Metropolitana de Belém (RMB), enfatizando a importância que o processo de formação e o crescimento urbano da RMB tem em relação as perdas de água, na medida em que este processo forçou a COSANPA a atender um número cada vez maior de usuários com obras improvisadas, levando a prevalência da improvisação e do empirismo na operação deste sistema. A pesquisa foi realizada para toda a área da RMB, visto que seria impossível determinar os índices de perdas para um setor isolado, em decorrência da ausência de setorização da rede de abastecimento de água que dificulta a obtenção de informações operacionais mais precisas. A metodologia utilizada para a determinação dos índices de perdas do sistema de abastecimento de água da COSANPA na RMB, foi baseada no estudo realizado por Silva et al (1998) para o Programa Nacional de Combate ao Desperdício de Água (PNCDA) e que em 2004 foi revisado por Marcka (2004). Os resultados obtidos com a determinação dos indicadores de perdas de nível básico e médio de complexidade refletem a fragilidade da COSANPA através de elevadíssimos índices de perdas, que além de estarem relacionados a problemas estruturais, são agravados pelas deficiências operacionais deste sistema. Conclui-se que medidas como a setorização da rede de abastecimento de água, hidrometração, atualização de cadastro, uso de novas tecnologias para detecção de vazamentos e fraudes e a capacitação operacional, com a criação de manuais técnicos, são ferramentas de combate a perdas reais e aparentes que podem mudar o quadro atual da COSANPA.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Polímeros são macromoléculas de alta massa molecular cada vez mais presentes nas atividades humanas. Estas moléculas são utilizadas com frequência para sintetizar plásticos, elastômeros e fibras. Os polímeros podem ser divididos em naturais e sintéticos. Os polímeros de origem natural são aqueles encontrados na natureza, como por exemplo: celulose, hemicelulose, glicogênio, proteínas, amido, lignina, entre outros. Os polímeros sintéticos são aqueles produzidos pela síntese química induzida pelo ser humano, como os diferentes tipos de plásticos. Contudo, alguns destes materiais sintéticos possuem alta durabilidade acarretando grande acúmulo de resíduos que contaminam o meio ambiente. O poliacrilato de sódio (PAS) é uma destas moléculas sintéticas que funciona como superabsorvente utilizado em grande escala nas fraldas descartáveis. A aplicação do PAS nas fraldas permitiu diminuir o volume deste material sem perda da eficácia. Cerca de 136 milhões de quilos de polímeros de poliacrilato são utilizados anualmente. Buscando diminuir a quantidade deste material no meio ambiente, são necessários estudos que viabilizem alternativas de sua decomposição. Dentre as opções viáveis está o processo de biodegradação, que é caracterizado pela ação de seres vivos, sobretudo os pertencentes ao grupo dos microrganismos (bactérias e fungos), que utilizam o material para retirar a energia para o seu desenvolvimento. Este projeto tem como objetivo avaliar a biodegradabilidade do poliacrilato de sódio (PAS) e modificar sua estrutura via degradação microbiana. Análises descritivas e comparativas são as bases para o estudo e compreensão da biodegradação do PAS. Para os testes de biodegradação serão utilizados microrganismos do solo e o fungo Aspergillus niger. Após 8 meses de biodegradação do composto enterrado pôde-se concluir através... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Several methods are used towards delayed onset muscle soreness appraisal. This study's goal was to investigate, amongst three commonly adopted methods, which one would be the most effective (the one that shows higher values) in the quantification of this phenomenon. 10 male subjects, of age 22.8 ± 3.1 years old, weight 80 ± 12.4 kg, height 174 ± 0.07 cm, without recent experience with strength training (lower limbs) and/or running took place in this study. All subjects carried out a muscle damage induction protocol, which consisted of 30 minute downhill running (-16% or -9.09º) at 80% speed compared to their maximum oxygen consumption. Muscle damage determinants such as isometric peak torque, knee joint range of motion and circumference of the medial portion of the thight were measured before, during, 24, 48, 72 and 96 hours after downhill running. The subjective pain perception was measured simultaneously with the other determinants through three different tests: sitting on and getting up of a chair; climbing and descending from a 45cm step; and self thigh palpation. After going through all subjective pain perception tests, the subjects filled out a visual analog scale with their perception of pain. Muscle damage changes over time were compared through variance analysis (ANOVA) one way for repeated measures. Subjective pain perception values obtained in all three different tests were compared through two way ANOVAs for repeated numbers. The significance level adopted in this study was z ≤ 0.05. The results showed that the step test was the on which better evaluated the delayed onset muscle soreness. No significant differences were found through the ADM and CIR recovery markers. Downhil running determined reduced of PTI (~22.4%). Significant links between pain were obtained for both subjective pain perception tests starting at 24 and 48 hours, where the highest registered average happened in the step test after 48h, with high...
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior
Resumo:
A avaliação do desempenho e a sua aplicação são, no actual enquadramento socioeconómico, cada vez mais necessárias, como forma de melhorar a eficácia e a eficiência entre as organizações. Para a prática profissional verifica-se que a implementação da avaliação de desempenho, apresenta lacunas que podem comprometê-la. Sabendo da importância do profissional para o sucesso da implementação da avaliação de desempenho, toma-se fundamental, analisar a sua percepção face ao modelo e sua implementação. O problema da instrução do presente estudo pretende saber quais as percepções dos técnicos de radiologia avaliados sujeitos ao modelo de avaliação de desempenho implantado no Hospital Curry Cabral. Tendo como objectivo ao nível da gestão, minimizar os obstáculos de implementação e maximizar os pontos fortes. Após pesquisa bibliográfica sobre os principais conceitos, foi definido domo objectivo da investigação empírica: - Comparar as percepções dos técnicos de radiologia submetidos ao modelo de avaliação desempenho ”Pró-Activo”. Recorrendo a uma metodologia exploratória e descritiva, estudámos o impacto dessas ferramentas utilizadas dentro da Unidade Hospitalar do estudo. A metodologia de recolha de informação aos profissionais expostos do estudo assentou em questionários de perguntas fechadas e abertas ambas com uma abordagem de carácter quantitativo. Para a análise e tratamento dos dados utilizou-se programas informáticos. As principais conclusões: verifica-se a falta de formação para todos os envolvidos, um processo desprovido de imparcialidade, neutralidade e rigor, bem como uma motivação geral dos profissionais em matéria de avaliação de desempenho. ABSTRACT - The evaluation of performance and its implementation are, in the current socioeconomic framing, each time more necessary as form to improve the effectiveness and the efficiency amidst the organizations. For the practical professional it is verified that the implementation of the performance evaluation, presents gaps that can compromise it. Knowing the importance of the individuals in the success of the implementation of the performance evaluation, it becomes basic to analyze its perceptions face to the model and its implementation. The problem of inquiry of this study pretends to know which the perceptions of the technicians of radiology evaluated and appraisers face to the models of evaluation of performance implanted in the Portuguese Hospitals (Hospital Curry Cabral). The purpose to the level of the management is to minimize the obstacles of implementation and to maximize the strong points. Bibliographical research on the main concepts was effectuated, after what we define the objectives of empirica inquiry: - To compare the perceptions of the radiology technicians subjected to models of performance evaluation “Pro-Activa”. Using an exploratory and descriptive approach, studied the impact of these tools used in the hospitals of the study. The methodology for collecting information to professionals out of the study based on questionnaires of both open and closed questions with a quantitative approach to nature. For analysis and data processing software was used. The main conclusions: there is the lack of training for all involved, a process devoid of impartiality, neutrality and accuracy, as well as a general motivation of the professionals regarding the evaluation of performance.
Resumo:
Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)