985 resultados para lung images
Resumo:
Funding The International Primary Care Respiratory Group (IPCRG) provided funding for this research project as an UNLOCK group study for which the funding was obtained through an unrestricted grant by Novartis AG, Basel, Switzerland. The latter funders had no role in study design, data collection and analysis, decision to publish or preparation of the manuscript. Database access for the OPCRD was provided by the Respiratory Effectiveness Group (REG) and Research in Real Life; the OPCRD statistical analysis was funded by REG. The Bocholtz Study was funded by PICASSO for COPD, an initiative of Boehringer Ingelheim, Pfizer and the Caphri Research Institute, Maastricht University, The Netherlands.
Resumo:
Background: Tumor volume has been shown to be a prognostic factor for the response of some tumors to radiotherapy. TNM stage has prognostic value for patients treated surgically for non-small cell lung cancer (NSCLC), but its value is less clear for patients treated by nonsurgical means. This may be because tumor size is not a consistent determinant of T stage or stage group. As part of the preliminary analyses for the Trans-Tasman Radiation Oncology Group 99-05 study, the authors performed this analysis to determine to what extent stage reflects tumor volume. Methods: In this prospective multicenter observational study, patients had to have histologically proven NSCLC, no evidence of disease beyond the primary site or thoracic lymph nodes, and been planned for radical radiotherapy with or without chemotherapy. Tumor volume measurements were based on computed tomography-based treatment planning images. Results: Four hundred four patients were available for analysis. There was a strong correlation between (log) maximum tumor diameter and (log) tumor volume (r = 0.93, p < 0.001). Although there was a highly significant trend of increasing volume with increasing T stage and stage group, when tumors were categorized into four groups according to increasing volume, there was only 55% concordance with T stage and 67% concordance with stage group. Conclusions: There is limited correlation between tumor size and disease stage in patients with NSCLC. This justifies documentation and investigation of size as a potential prognostic factor independent of stage. Maximum tumor diameter may be an adequate substitute for volume as a measurement of size.
Resumo:
Characterizing engineered human lung tissue is an important step in developing a functional tissue replacement for lung tissue repair and in vitro analysis. Small tissue constructs were grown by seeding IMR-90 fetal lung fibroblasts and adult microvascular endothelial cells onto a Polyglycolic acid (PGA) polymer template. Introducing the constructs to dynamic culture conditions inside a bioreactor facilitated three-dimensional growth seen in scanning electron microscopy images (SEM). Characterization of the resultant tissue samples was done using SEM imagery, tensile tests, and biochemical assays to quantify extra-cellular matrix (ECM) composition. Tensile tests of the engineered samples indicated an increase in the mechanical properties when compared with blank constructs. Elastin and collagen content was found to average 3.19% and 15.49% respectively in relation to total mass of the tissue samples. The presence of elastin and collagen within the constructs most likely explains the mechanical differences that we noted. These findings suggest that the necessary ECM can be established in engineered tissue constructs and that optimization of this procedure has the capacity to generate the load bearing elements required for construction of a functional lung tissue equivalent.
Resumo:
Radiotherapy is commonly used to treat lung cancer. However, radiation induced damage to lung tissue is a major limiting factor to its use. To minimize normal tissue lung toxicity from conformal radiotherapy treatment planning, we investigated the use of Perfluoropropane(PFP)-enhanced MR imaging to assess and guide the sparing of functioning lung. Fluorine Enhanced MRI using Perfluoropropane(PFP) is a dynamic multi-breath steady state technique enabling quantitative and qualitative assessments of lung function(1).
Imaging data was obtained from studies previously acquired in the Duke Image Analysis Laboratory. All studies were approved by the Duke IRB. The data was de-identified for this project, which was also approved by the Duke IRB. Subjects performed several breath-holds at total lung capacity(TLC) interspersed with multiple tidal breaths(TB) of Perfluoropropane(PFP)/oxygen mixture. Additive wash-in intensity images were created through the summation of the wash-in phase breath-holds. Additionally, model based fitting was utilized to create parametric images of lung function(1).
Varian Eclipse treatment planning software was used for putative treatment planning. For each subject two plans were made, a standard plan, with no regional functional lung information considered other than current standard models. Another was created using functional information to spare functional lung while maintaining dose to the target lesion. Plans were optimized to a prescription dose of 60 Gy to the target over the course of 30 fractions.
A decrease in dose to functioning lung was observed when utilizing this functional information compared to the standard plan for all five subjects. PFP-enhanced MR imaging is a feasible method to assess ventilatory lung function and we have shown how this can be incorporated into treatment planning to potentially decrease the dose to normal tissue.