942 resultados para low-rise buildings


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Constructing buildings using slip formed load bearing wall panels is becoming increasingly popular in Sri Lanka due to several advantages; low cost, environmental friendliness and rapid construction technique. These wall panels are already successfully implemented in many low rise buildings. However, the seismic capacities of these buildings have not been properly studied. Few seismic activities reported in Sri Lanka have not caused severe structural damage, but predictions can not be made as to whether this will continue to be the case in the future. This highlights the need to study the seismic capacity of buildings constructed in slip formed load bearing wall panels. This paper presents a study of the seismic capacity of the existing medium rise building.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold-formed high strength steel members are increasingly used as primary load bearing components in low rise buildings. Lipped channel beam (LCB) is one of the most commonly used flexural members in these applications. In this research an experimental study was undertaken to investigate the shear behaviour and strengths of LCB sections. Simply supported test specimens of back to back LCBs with aspect ratios of 1.0 and 1.5 were loaded at mid-span until failure. Test specimens were chosen such that all three types of shear failure (shear yielding, inelastic and elastic shear buckling) occurred in the tests. The ultimate shear capacity results obtained from the tests were compared with the predictions from the current design rules in Australian/NewZealand and American cold-formed steel design standards. This comparison showed that these shear design rules are very conservative as they did not include the post-buckling strength observed in the shear tests and the higher shear buckling coefficient due to the additional fixity along the web-flange juncture. Improved shear design equations are proposed in this paper by including the above beneficial effects. Suitable lower bound design rules were also developed under the direct strength method format. This paper presents the details of this experimental study and the results including the improved design rules for the shear capacity of LCBs. It also includes the details of tests of LCBs subject to combined shear and flange distortion, and combined bending and shear actions, and proposes suitable design rules to predict the capacities in these cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During high wind events, crest-fixed profiled steel roof claddings in low-rise buildings can be subjected to combined cyclic wind uplift and in-plane racking (shear) forces. Static and cyclic tests of corrugated steel roof claddings were carried out to investigate the effect of in-plane racking force on the uplift strength, in particular, in relation to the fatigue cracking commonly observed under cyclic wind uplift. The presence of racking force appeared to have insignificant effect on the static and cyclic wind uplift strength. It may therefore be possible to include the diaphragm strength of these claddings in the design of low-rise buildings in a similar manner to valley-fixed claddings. This may lead to a reduction in bracing requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extreme wind events such as tropical cyclones, tornadoes and storms are more likely to impact the Australian coastal regions due to possible climate changes. Such events can be extremely destructive to building structures, in particular, low-rise buildings with lightweight roofing systems that are commonly made of thin steel roofing sheets and battens. Large wind uplift loads that act on the roofs during high wind events often cause premature roof connection failures. Recent wind damage investigations have shown that roof failures have mostly occurred at the batten to rafter or truss screw connections. In most of these cases, the screw fastener heads pulled through the bottom flanges of thin steel roof battens. This roof connection failure is very critical as both roofing sheets and battens will be lost during the high wind events. Hence, a research study was conducted to investigate this critical pull-through failure using both experimental and numerical methods. This paper presents the details of numerical modeling and the results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diaphragm action of crest-fixed profiled steel claddings is present in low-rise buildings whether the designer acknowledges it or not. For the designers to take advantage of the diaphragm strength of the crest-fixed steel claddings in the design of low-rise buildings in a similar manner to valley-fixed claddings, and to design the buildings based on the true behaviour rather than the assumed behaviour, shear/racking behaviour of the three trapezoidal and corrugated steel claddings commonly used at present was investigated using large scale experiments. Crest-fixed claddings (up to a maximum size of 6 x 6.2m) with different aspect ratio and fastening systems were tested to failure, based on which suitable shear strength and stiffness values have been proposed for these claddings as they are used at present. A simple analytical model combined with basic connection data from small scale experiments was used to predict the shear strength of tested panels. Currently attempts are being made to develop general design formulae to determine shear strength and stiffness of crest-fixed steel claddings...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The solar and longwave environmental irradiance geometry (SOLWEIG) model simulates spatial variations of 3-D radiation fluxes and mean radiant temperature (T mrt) as well as shadow patterns in complex urban settings. In this paper, a new vegetation scheme is included in SOLWEIG and evaluated. The new shadow casting algorithm for complex vegetation structures makes it possible to obtain continuous images of shadow patterns and sky view factors taking both buildings and vegetation into account. For the calculation of 3-D radiation fluxes and T mrt, SOLWEIG only requires a limited number of inputs, such as global shortwave radiation, air temperature, relative humidity, geographical information (latitude, longitude and elevation) and urban geometry represented by high-resolution ground and building digital elevation models (DEM). Trees and bushes are represented by separate DEMs. The model is evaluated using 5 days of integral radiation measurements at two sites within a square surrounded by low-rise buildings and vegetation in Göteborg, Sweden (57°N). There is good agreement between modelled and observed values of T mrt, with an overall correspondence of R 2 = 0.91 (p < 0.01, RMSE = 3.1 K). A small overestimation of T mrt is found at locations shadowed by vegetation. Given this good performance a number of suggestions for future development are identified for applications which include for human comfort, building design, planning and evaluation of instrument exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Per quanto riguarda le costruzioni in conglomerato cementizio armato gettato in opera, i sistemi strutturali più comunemente utilizzati sono quelli a telaio (con trasmissione di momento flettente), a setti portanti o una combinazione di entrambi. A partire dagli anni ’60, numerosissimi sono stati gli studi relativamente al comportamento sismico di strutture in c.a. a telaio. Lo stesso si può affermare per le costruzioni costituite da pareti miste a telai. In particolare, l’argomento della progettazione sismica di tali tipologie di edifici ha sempre riguardato soprattutto gli edifici alti nei quali, evidentemente, l’impiego delle pareti avveniva allo scopo di limitarne la elevata deformabilità. Il comportamento sismico di strutture realizzate interamente a pareti portanti in c.a. è stato meno studiato negli anni, nonostante si sia osservato che edifici realizzati mediante tali sistemi strutturali abbiano mostrato, in generale, pregevoli risorse di resistenza nei confronti di terremoti anche di elevata intensità. Negli ultimi 10 anni, l’ingegneria sismica si sta incentrando sull’approfondimento delle risorse di tipologie costruttive di cui si è sempre fatto largo uso in passato (tipicamente nei paesi dell’Europa continentale, in America latina, negli USA e anche in Italia), ma delle quali mancavano adeguate conoscenze scientifiche relativamente al loro comportamento in zona sismica. Tali tipologie riguardano sostanzialmente sistemi strutturali interamente costituiti da pareti portanti in c.a. per edifici di modesta altezza, usualmente utilizzati in un’edilizia caratterizzata da ridotti costi di realizzazione (fabbricati per abitazioni civili e/o uffici). Obiettivo “generale” del lavoro di ricerca qui presentato è lo studio del comportamento sismico di strutture realizzate interamente a setti portanti in c.a. e di modesta altezza (edilizia caratterizzata da ridotti costi di realizzazione). In particolare, le pareti che si intendono qui studiare sono caratterizzate da basse percentuali geometriche di armatura e sono realizzate secondo la tecnologia del cassero a perdere. A conoscenza dello scrivente, non sono mai stati realizzati, fino ad oggi, studi sperimentali ed analitici allo scopo di determinare il comportamento sismico di tali sistemi strutturali, mentre è ben noto il loro comportamento statico. In dettaglio, questo lavoro di ricerca ha il duplice scopo di: • ottenere un sistema strutturale caratterizzato da elevate prestazioni sismiche; • mettere a punto strumenti applicativi (congruenti e compatibili con le vigenti normative e dunque immediatamente utilizzabili dai progettisti) per la progettazione sismica dei pannelli portanti in c.a. oggetto del presente studio. Al fine di studiare il comportamento sismico e di individuare gli strumenti pratici per la progettazione, la ricerca è stata organizzata come segue: • identificazione delle caratteristiche delle strutture studiate, mediante lo sviluppo/specializzazione di opportune formulazioni analitiche; • progettazione, supervisione, ed interpretazione di una estesa campagna di prove sperimentali eseguita su pareti portanti in c.a. in vera grandezza, al fine di verificarne l’efficace comportamento sotto carico ciclico; • sviluppo di semplici indicazioni (regole) progettuali relativamente alle strutture a pareti in c.a. studiate, al fine di ottenere le caratteristiche prestazionali desiderate. I risultati delle prove sperimentali hanno mostrato di essere in accordo con le previsioni analitiche, a conferma della validità degli strumenti di predizione del comportamento di tali pannelli. Le elevatissime prestazioni riscontrate sia in termini di resistenza che in termini di duttilità hanno evidenziato come le strutture studiate, così messe a punto, abbiano manifestato un comportamento sismico più che soddisfacente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Widespread damage to roofing materials (such as tiles and shingles) for low-rise buildings, even for weaker hurricanes, has raised concerns regarding design load provisions and construction practices. Currently the building codes used for designing low-rise building roofs are mainly based on testing results from building models which generally do not simulate the architectural features of roofing materials that may significantly influence the wind-induced pressures. Full-scale experimentation was conducted under high winds to investigate the effects of architectural details of high profile roof tiles and asphalt shingles on net pressures that are often responsible for damage to these roofing materials. Effects on the vulnerability of roofing materials were also studied. Different roof models with bare, tiled, and shingled roof decks were tested. Pressures acting on both top and bottom surfaces of the roofing materials were measured to understand their effects on the net uplift loading. The area-averaged peak pressure coefficients obtained from bare, tiled, and shingled roof decks were compared. In addition, a set of wind tunnel tests on a tiled roof deck model were conducted to verify the effects of tiles' cavity internal pressure. Both the full-scale and the wind tunnel test results showed that underside pressure of a roof tile could either aggravate or alleviate wind uplift on the tile based on its orientation on the roof with respect to the wind angle of attack. For shingles, the underside pressure could aggravate wind uplift if the shingle is located near the center of the roof deck. Bare deck modeling to estimate design wind uplift on shingled decks may be acceptable for most locations but not for field locations; it could underestimate the uplift on shingles by 30-60%. In addition, some initial quantification of the effects of roofing materials on wind uplift was performed by studying the wind uplift load ratio for tiled versus bare deck and shingled versus bare deck. Vulnerability curves, with and without considering the effects of tiles' cavity internal pressure, showed significant differences. Aerodynamic load provisions for low-rise buildings' roofs and their vulnerability can thus be more accurately evaluated by considering the effects of the roofing materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Major portion of hurricane-induced economic loss originates from damages to building structures. The damages on building structures are typically grouped into three main categories: exterior, interior, and contents damage. Although the latter two types of damages, in most cases, cause more than 50% of the total loss, little has been done to investigate the physical damage process and unveil the interdependence of interior damage parameters. Building interior and contents damages are mainly due to wind-driven rain (WDR) intrusion through building envelope defects, breaches, and other functional openings. The limitation of research works and subsequent knowledge gaps, are in most part due to the complexity of damage phenomena during hurricanes and lack of established measurement methodologies to quantify rainwater intrusion. This dissertation focuses on devising methodologies for large-scale experimental simulation of tropical cyclone WDR and measurements of rainwater intrusion to acquire benchmark test-based data for the development of hurricane-induced building interior and contents damage model. Target WDR parameters derived from tropical cyclone rainfall data were used to simulate the WDR characteristics at the Wall of Wind (WOW) facility. The proposed WDR simulation methodology presents detailed procedures for selection of type and number of nozzles formulated based on tropical cyclone WDR study. The simulated WDR was later used to experimentally investigate the mechanisms of rainwater deposition/intrusion in buildings. Test-based dataset of two rainwater intrusion parameters that quantify the distribution of direct impinging raindrops and surface runoff rainwater over building surface — rain admittance factor (RAF) and surface runoff coefficient (SRC), respectively —were developed using common shapes of low-rise buildings. The dataset was applied to a newly formulated WDR estimation model to predict the volume of rainwater ingress through envelope openings such as wall and roof deck breaches and window sill cracks. The validation of the new model using experimental data indicated reasonable estimation of rainwater ingress through envelope defects and breaches during tropical cyclones. The WDR estimation model and experimental dataset of WDR parameters developed in this dissertation work can be used to enhance the prediction capabilities of existing interior damage models such as the Florida Public Hurricane Loss Model (FPHLM).^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of building envelopes and roofing systems significantly depends on accurate knowledge of wind loads and the response of envelope components under realistic wind conditions. Wind tunnel testing is a well-established practice to determine wind loads on structures. For small structures much larger model scales are needed than for large structures, to maintain modeling accuracy and minimize Reynolds number effects. In these circumstances the ability to obtain a large enough turbulence integral scale is usually compromised by the limited dimensions of the wind tunnel meaning that it is not possible to simulate the low frequency end of the turbulence spectrum. Such flows are called flows with Partial Turbulence Simulation. In this dissertation, the test procedure and scaling requirements for tests in partial turbulence simulation are discussed. A theoretical method is proposed for including the effects of low-frequency turbulences in the post-test analysis. In this theory the turbulence spectrum is divided into two distinct statistical processes, one at high frequencies which can be simulated in the wind tunnel, and one at low frequencies which can be treated in a quasi-steady manner. The joint probability of load resulting from the two processes is derived from which full-scale equivalent peak pressure coefficients can be obtained. The efficacy of the method is proved by comparing predicted data derived from tests on large-scale models of the Silsoe Cube and Texas-Tech University buildings in Wall of Wind facility at Florida International University with the available full-scale data. For multi-layer building envelopes such as rain-screen walls, roof pavers, and vented energy efficient walls not only peak wind loads but also their spatial gradients are important. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. Large-scale experiments were carried out to investigate the wind loading on concrete pavers including wind blow-off tests and pressure measurements. Simplified guidelines were developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as ASCE 7-10 on pressure coefficients on components and cladding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes engineering applications that come from extending seismic networks into building structures. The proposed applications will benefit the data from the newly developed crowd-sourced seismic networks which are composed of low-cost accelerometers. An overview of the Community Seismic Network and the earthquake detection method are addressed. In the structural array components of crowd-sourced seismic networks, there may be instances in which a single seismometer is the only data source that is available from a building. A simple prismatic Timoshenko beam model with soil-structure interaction (SSI) is developed to approximate mode shapes of buildings using natural frequency ratios. A closed form solution with complete vibration modes is derived. In addition, a new method to rapidly estimate total displacement response of a building based on limited observational data, in some cases from a single seismometer, is presented. The total response of a building is modeled by the combination of the initial vibrating motion due to an upward traveling wave, and the subsequent motion as the low-frequency resonant mode response. Furthermore, the expected shaking intensities in tall buildings will be significantly different from that on the ground during earthquakes. Examples are included to estimate the characteristics of shaking that can be expected in mid-rise to high-rise buildings. Development of engineering applications (e.g., human comfort prediction and automated elevator control) for earthquake early warning system using probabilistic framework and statistical learning technique is addressed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los muros cortina modulares están constituidos por paneles prefabricados que se fijan al edificio a través de anclajes a lo largo del borde del forjado. El proceso de prefabricación garantiza buena calidad y control de los acabados y el proceso de instalación es rápido y no requiere andamiaje. Por estas razones su uso está muy extendido en torres. Sin embargo, el diseño de los marcos de aluminio podría ser más eficiente si se aprovechara la rigidez de los vidrios para reducir la profundidad estructural de los montantes. Asimismo, se podrían reducir los puentes térmicos en las juntas si se sustituyeran los marcos por materiales de menor conductividad térmica que el aluminio. Esta investigación persigue desarrollar un muro cortina alternativo que reduzca la profundidad estructural, reduzca la transmisión térmica en las juntas y permita un acabado enrasado al interior, sin que sobresalgan los montantes. La idea consiste en conectar un marco de material compuesto de fibra de vidrio a lo largo del borde del vidrio aislante a través de adhesivos estructurales para así movilizar una acción estructural compuesta entre los dos vidrios y lograr una baja transmitancia térmica. El marco ha de estar integrado en la profundidad del vidrio aislante. En una primera fase se han efectuado cálculos estructurales y térmicos preliminares para evaluar las prestaciones a un nivel esquemático. Además, se han realizado ensayos a flexión en materiales compuestos de fibra de vidrio y ensayos a cortante en las conexiones adhesivas entre vidrio y material compuesto. Con la información obtenida se ha seleccionado el material del marco y del adhesivo y se han efectuado cambios sobre el diseño original. Los análisis numéricos finales demuestran una reducción de la profundidad estructural de un 80% y una reducción de la transmisión térmica de un 6% en comparación con un sistema convencional tomado como referencia. El sistema propuesto permite obtener acabados enrasados. ABSTRACT Unitised curtain wall systems consist of pre manufactured cladding panels which can be fitted to the building via pre fixed brackets along the edge of the floor slab. They are universally used for high rise buildings because the factory controlled assembly of units ensures high quality and allows fast installation without external access. However, its frame is structurally over-dimensioned because it is designed to carry the full structural load, failing to take advantage of potential composite contribution of glass. Subsequently, it is unnecessarily deep, occupying valuable space, and protrudes to the inside, causing visual disruption. Moreover, it is generally made of high thermal conductivity metal alloys, contributing to substantial thermal transmission at joints. This research aims to develop a novel frame-integrated unitised curtain wall system that will reduce thermal transmission at joints, reduce structural depth significantly and allow an inside flush finish. The idea is to adhesively bond a Fibre Reinforced Polymer (FRP) frame to the edge of the Insulated Glass Unit (IGU), thereby achieving composite structural behaviour and low thermal transmittance. The frame is to fit within the glazing cavity depth. Preliminary analytical structural and numerical thermal calculations are carried out to assess the performance of an initial schematic design. 4-point bending tests on GFRP and single-lap shear tests on bonded connections between GFRP and glass are performed to inform the frame and adhesive material selection process and to characterise these materials. Based on the preliminary calculations and experimental tests, some changes are put into effect to improve the performance of the system and mitigate potential issues. Structural and thermal numerical analysis carried out on the final detail design confirm a reduction of the structural depth to almost one fifth and a reduction of thermal transmission of 6% compared to a benchmark conventional system. A flush glazed appearance both to the inside and the outside are provided while keeping the full functionality of a unitised system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a detailed description of the influence of critical parameters that govern the vulnerability of columns under lateral impact loads. Numerical simulations are conducted by using the Finite Element program LS-DYNA, incorporating steel reinforcement, material models and strain rate effects. A simplified method based on impact pulse generated from full scale impact tests is used for impact reconstruction and effects of the various pulse loading parameters are investigated under low to medium velocity impacts. A constitutive material model which can simulate failures under tri-axial state of stresses is used for concrete. Confinement effects are also introduced to the numerical simulation and columns of Grade 30 to 50 concrete under pure axial loading are analysed in detail. This research confirmed that the vulnerability of the axially loaded columns can be mitigated by reducing the slenderness ratio and concrete grade, and by choosing the design option with a minimal amount of longitudinal steel. Additionally, it is evident that approximately a 50% increase in impact capacity can be gained for columns in medium rise buildings by enhancing the confinement effects alone. Results also indicated that the ductility as well as the mode of failure under impact can be changed with the volumetric ratio of lateral steel. Moreover, to increase the impact capacity of the vulnerable columns, a higher confining stress is required. The general provisions of current design codes do not sufficiently cover this aspect and hence this research will provide additional guidelines to overcome the inadequacies of code provisions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Differential axial shortening, distortion and deformation in high rise buildings is a serious concern. They are caused by three time dependent modes of volume change; “shrinkage”, “creep” and “elastic shortening” that takes place in every concrete element during and after construction. Vertical concrete components in a high rise building are sized and designed based on their strength demand to carry gravity and lateral loads. Therefore, columns and walls are sized, shaped and reinforced differently with varying concrete grades and volume to surface area ratios. These structural components may be subjected to the detrimental effects of differential axial shortening that escalates with increasing the height of buildings. This can have an adverse impact on other structural and non-structural elements. Limited procedures are available to quantify axial shortening, and the results obtained from them differ because each procedure is based on various assumptions and limited to few parameters. All these prompt to a need to develop an accurate numerical procedure to quantify the axial shortening of concrete buildings taking into account the important time varying functions of (i) construction sequence (ii) Young’s Modulus and (iii) creep and shrinkage models associated with reinforced concrete. General assumptions are refined to minimize variability of creep and shrinkage parameters to improve accuracy of the results. Finite element techniques are used in the procedure that employs time history analysis along with compression only elements to simulate staged construction behaviour. This paper presents such a procedure and illustrates it through an example. Keywords: Differential Axial Shortening, Concrete Buildings, Creep and Shrinkage, Construction Sequence, Finite Element Method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

With significant population growth experienced in South East Queensland over the past two decades and a high rate of growth expected to continue in coming decades, the Queensland Government is promoting urban consolidation planning policies to manage growth sustainably. Multi-residential buildings will play an important role in facilitating the increased densities which urban consolidation policies imply. However, a major flood event in January 2011 has brought to light the vulnerability of certain types of multi-residential typologies to power outages. The crisis conditions exposed how contemporary building design and construction practices, coupled with regulatory and planning issues, appear to have compromised the resilience and habitability of multi-storey residential buildings. In the greater urban area of Brisbane, Queensland, the debilitating dependence that certain types of apartment buildings have on mains electricity was highlighted by residents’ experiences of the Brisbane River flood disaster, before, during and after the event. This research examined high density residential buildings in West End, Brisbane, an inner city suburb which was severely affected by the flood and is earmarked for significant urban densification under the Brisbane City Plan. Medium-to-high-density residential buildings in the suburb were mapped in flooded and non-flooded locations and a database containing information about the buildings was created. Parameters included date of construction, number of storeys, systems of access and circulation, and potential for access to natural light and ventilation for habitable areas. A series of semi-structured interviews were conducted with residents involved in the owners’ management committees of several buildings to verify information the mapping could not provide. The interviews identified a number of critical systems failures due to power outage which had a significant impact on residents’ wellbeing, comfort and safety. Building services such as lifts, running water, fire alarms, security systems and air-conditioning ceased to operate when power was disconnected to neighbourhoods and buildings in anticipation of rising flood waters. Lack of access to buildings and dwellings, lack of safety, lack of building security, and lack of thermal comfort affected many residents whether or not their buildings were actually subjected to inundation, with some buildings rendered uninhabitable for a prolonged period. The extent of the impact on residents was dramatically influenced by the scale and type of building inhabited, with those dwelling in buildings under a 25m height limit, with a single lift, found to be most affected. The energy-dependency and strong trend of increasing power demands of high-rise buildings is well-documented. Extended electricity outages such as the one brought about by the 2011 flood in Queensland are likely to happen more frequently than the 50-year average of the flood event itself. Electricity blackouts can result from a number of man-made or natural causes, including shortages caused by demand exceeding supply. This paper highlights the vulnerability of energy-dependent buildings to power outages and investigates options for energy security for occupants of multi-storey buildings and makes recommendations to increase resilience and general liveability in multi-residential buildings in the subtropics through design modifications.