954 resultados para low drug dose
Resumo:
An experiment was conducted to examine the luteolytic effectiveness of using low or micro doses of PGF2α when administered at the BAI HUI acupuncture point, which is frequently used to treat ovarian disturbances in veterinary acupuncture. The results indicate that PGF2α given at a very low micro dose of 0.5 mg (one tenth the conventional recommended dose) administered at the BAI HUI acupuncture point located at the sacral lumbar space is equally effective at inducing luteolysis in mid-luteal phase mares as conventional PGF2α i.m. treatment using a tenfold higher dose. Therefore, based on the results of the present study, we suggest that the BAI HUI sacrai lumbar route somehow provides an extremely efficient pathway for the drug to the ovarian level.
Resumo:
Background Low dose combined oral contraceptives (COC) can interfere in bone mass acquisition during adolescence. To evaluate bone mineral density (BMD) and bone mineral content (BMC) in female adolescents taking a standard low-dose (EE 20 µg/Desogestrel 150 µg) combination oral contraceptive (COC) over a one-year period and compare with healthy adolescents from the same age group not taking COCs.Methods A non-randomised parallel control study with one-year follow-up. Sixty-seven adolescents from 12 to 20 years of age, divided into COC users (n = 41) taking 20 µg EE/150 µg Desogestrel and non-user controls (n = 26), were evaluated through bone densitometry examinations at baseline and 12 months later. Comparisons between groups at study start was done through the Mann-Whitney test with significance level fixed at 5% or corresponding p value; comparisons between groups at study start and 12 months later used variations in median percentages for bone mass variables.Results COC users presented low bone mass acquisition in the lumbar spine and BMD and BMC median variations between baseline and at 12 months of 2.07% and +1.57% respectively whereas the control group presented variations of +12.16% and +16.84% for BMD and BMC, respectively, over the same period. The total body BMD and BMC presented similar evolution during the study in both groups. Statistical significance (pConclusion The use of a low COC dose (EE 20 µg/Desogestrel 150 µg) was associated to lower bone mass acquisition in adolescents during the study period.Trial registration: (Register Number):RBR-5 h9b3c
Resumo:
Background: Treatment of chronically infected wounds is a challenge, and bacterial environmental contamination is a growing issue in infection control. Ozone may have a role in these situations. The objective of this study was to determine whether a low dose of gaseous ozone/oxygen mixture eliminates pathogenic bacteria cultivated in Petri dishes. Methods: A pilot study with 6 bacterial strains was made using different concentrations of ozone in an ozone-oxygen mixture to determine a minimally effective dose that completely eliminated bacterial growth. The small and apparently bactericidal gaseous dose of 20 mu g/mL ozone/oxygen (1: 99) mixture, applied for 5min under atmospheric pressure was selected. In the 2nd phase, eight bacterial strains with well characterized resistance patterns were evaluated in vitro using agar-blood in adapted Petri dishes (10(5) bacteria/dish). The cultures were divided into 3 groups: 1-ozone-oxygen gaseous mixture containing 20 mu g of O-3/mL for 5 min; 2- 100% oxygen for 5 min; 3- baseline: no gas was used. Results: The selected ozone dose was applied to the following eight strains: Escherichia coli, oxacillin-resistant Staphylococcus aureus, oxacillin-susceptible Staphylococcus aureus, vancomycin-resistant Enterococcus faecalis, extended-spectrum beta-lactamase-producing Klebsiella pneumoniae, carbapenem-resistant Acinetobacter baumannii, Acinetobacter baumannii susceptible only to carbapenems, and Pseudomonas aeruginosa susceptible to imipenem and meropenem. All isolates were completely inhibited by the ozone-oxygen mixture while growth occurred in the other 2 groups. Conclusion: A single topical application by nebulization of a low ozone dose completely inhibited the growth of all potentially pathogenic bacterial strains with known resistance to antimicrobial agents.
Resumo:
This review summarizes current evidence based on pertinent literature on low-dose computed tomography angiography (CTA) of the body. Various strategies for optimizing CTA protocols with the aim to lower the radiation dose while maintaining the diagnostic accuracy of the examination are summarized. To date, various publications have demonstrated that CTA of the body can be performed at a low radiation dose while providing high quality information. Nevertheless, a number of questions still need to be answered, including the optimal combination of tube voltage and tube current settings, as well as the appropriate protocol parameters in relation to the body physiognomy and the specific body region imaged.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
In today’s healthcare paradigm, optimal sedation during anesthesia plays an important role both in patient welfare and in the socio-economic context. For the closed-loop control of general anesthesia, two drugs have proven to have stable, rapid onset times: propofol and remifentanil. These drugs are related to their effect in the bispectral index, a measure of EEG signal. In this paper wavelet time–frequency analysis is used to extract useful information from the clinical signals, since they are time-varying and mark important changes in patient’s response to drug dose. Model based predictive control algorithms are employed to regulate the depth of sedation by manipulating these two drugs. The results of identification from real data and the simulation of the closed loop control performance suggest that the proposed approach can bring an improvement of 9% in overall robustness and may be suitable for clinical practice.
Resumo:
In today’s healthcare paradigm, optimal sedation during anesthesia plays an important role both in patient welfare and in the socio-economic context. For the closed-loop control of general anesthesia, two drugs have proven to have stable, rapid onset times: propofol and remifentanil. These drugs are related to their effect in the bispectral index, a measure of EEG signal. In this paper wavelet time–frequency analysis is used to extract useful information from the clinical signals, since they are time-varying and mark important changes in patient’s response to drug dose. Model based predictive control algorithms are employed to regulate the depth of sedation by manipulating these two drugs. The results of identification from real data and the simulation of the closed loop control performance suggest that the proposed approach can bring an improvement of 9% in overall robustness and may be suitable for clinical practice.
Resumo:
BACKGROUND: Photodynamic therapy (PDT) at low drug-light conditions can enhance the transport of intravenously injected macromolecular therapeutics through the tumor vasculature. Here we determined the impact of PDT on the distribution of liposomal doxorubicin (Liporubicin™) administered by isolated lung perfusion (ILP) in sarcomas grown on rodent lungs. METHODS: A syngeneic methylcholanthrene-induced sarcoma cell line was implanted subpleurally in the left lung of Fischer rats. Treatment schemes consisted in ILP alone (400 μg of Liporubicin), low-dose (0.0625 mg/kg Visudyne®, 10 J/cm(2) and 35 mW/cm(2)) and high-dose left lung PDT (0.125 mg/kg Visudyne, 10 J/cm(2) and 35 mW/cm(2)) followed by ILP (400 μg of Liporubicin). The uptake and distribution of Liporubicin in tumor and lung tissues were determined by high-performance liquid chromatography and fluorescence microscopy in each group. RESULTS: Low-dose PDT significantly improved the distribution of Liporubicin in tumors compared to high-dose PDT (p < 0.05) and ILP alone (p < 0.05). However, both PDT pretreatments did not result in a higher overall drug uptake in tumors or a higher tumor-to-lung drug ratio compared to ILP alone. CONCLUSIONS: Intraoperative low-dose Visudyne-mediated PDT enhances liposomal doxorubicin distribution administered by ILP in sarcomas grown on rodent lungs which is predicted to improve tumor control by ILP.
Resumo:
In this paper we present a prototype of a control flow for an a posteriori drug dose adaptation for Chronic Myelogenous Leukemia (CML) patients. The control flow is modeled using Timed Automata extended with Tasks (TAT) model. The feedback loop of the control flow includes the decision-making process for drug dose adaptation. This is based on the outputs of the body response model represented by the Support Vector Machine (SVM) algorithm for drug concentration prediction. The decision is further checked for conformity with the dose level rules of a medical guideline. We also have developed an automatic code synthesizer for the icycom platform as an extension of the TIMES tool.
Resumo:
BACKGROUND: Visudyne®-mediated photodynamic therapy (PDT) at low drug/light conditions has shown to selectively enhance the uptake of liposomal doxorubicin in subpleural localized sarcoma tumors grown on rodent lungs without causing morphological alterations of the lung. The present experiments explore the impact of low-dose PDT on liposomal doxorubicin (Liporubicin™) uptake to different tumor types grown on rodent lungs. MATERIAL AND METHODS: Three groups of Fischer rats underwent subpleural generation of sarcoma, mesothelioma, or adenocarcinoma tumors on the left lung. At least five animals of each group (sarcoma, n = 5; mesothelioma, n = 7; adenocarcinoma, n = 5) underwent intraoperative low-dose (10 J/cm(2) at 35 mW/cm(2) ) PDT with 0.0625 mg/kg Visudyne® of the tumor and the lower lobe. This was followed by intravenous (IV) administration of 400 µg Liporubicin™. After a circulation time of 60 min, the tumor-bearing lung was processed for HPLC analyses. At least five animals per group underwent the same procedure but without PDT (sarcoma, n = 5; mesothelioma, n = 5; adenocarcinoma, n = 6). Five untreated animals per group underwent CD31 immunostaining of their tumors with histomorphometrical assessment of the tumor vascularization. RESULTS: Low-dose PDT significantly enhanced Liporubicin™ uptake to all tumor types (sarcoma, P = 0.0007; mesothelioma, P = 0.001; adenocarcinoma, P = 0.02) but not to normal lung tissue compared to IV drug administration alone. PDT led to a significantly increased ratio of tumor to lung tissue drug uptake for all three tumor types (P < 0.05). However, the tumor drug uptake varied between tumor types and paralleled tumor vascular density. The vascular density was significantly higher in sarcoma than in adenocarcinoma (P < 0.001) and mesothelioma (P < 0.001), whereas there was no significant difference between adenocarcinoma and mesothelioma. CONCLUSION: Low-dose Visudyne®-mediated PDT selectively enhances the uptake of systemically administered liposomal doxorubicin in tumors without affecting the drug uptake to normal lung. However, drug uptake varied significantly between tumor types and paralleled tumor vascular density.
Resumo:
OBJECTIVE: To measure the in vivo variations of CYP3A activity induced by anti-HIV drugs in human immunodeficiency virus (HIV)1-positive patients. METHODS: A low oral dose of midazolam (MID) (0.075 mg) was given to the patients and the 30-min total 1-OH midazolam (1-OHMID)/MID ratio was determined. Patients were phenotyped either before the introduction of antiretroviral treatments (control group, 90 patients) or after a variable period of antiretroviral treatment (56 patients). Twenty-one subjects underwent multiple phenotyping tests (before and during the course of the treatment). RESULTS: The median MID ratio was 3.51 in the control group (range 0.20-14.6). It was 5-fold higher in the group with efavirenz (28 patients; median, range: 16.0, 3.81-367; P < 0.0001), 13-fold lower with nelfinavir (18 patients; 0.27, 0.06-36.3; P < 0.0001), 17-fold lower with efavirenz + ritonavir (three patients; 0.21, 0.05-0.47; P = 0.006), 50-fold lower with ritonavir (four patients; 0.07, 0.06-0.17; P = 0.0007), and 7-fold lower with nevirapine + (ritonavir or nelfinavir or grapefruit juice) (three patients; 0.48, 0.03-1.83; P = 0.03). CYP3A activity was lower in the efavirenz + ritonavir group (P = 0.01) and in the ritonavir group (P = 0.04) than in the nelfinavir group, although already strongly inhibited in the latter. CONCLUSION: The low-dose MID phenotyping test was successfully used to measure the in vivo variations of CYP3A activity induced by antiretroviral drugs. Efavirenz strongly induces CYP3A activity, while ritonavir almost completely inhibits it. Nelfinavir strongly decreases CYP3A activity, but to a lesser extent than ritonavir. The inhibition of CYP3A by ritonavir or nelfinavir offsets the inductive effects of efavirenz or nevirapine administered concomitantly. Finally, no induction of CYP3A activity was noticeable after long-term administration of ritonavir at low dosages (200 mg/day b.i.d.) or of nelfinavir at standard dosages (2,500 mg/day b.i.d.).
Resumo:
BACKGROUND: : A primary goal of clinical pharmacology is to understand the factors that determine the dose-effect relationship and to use this knowledge to individualize drug dose. METHODS: : A principle-based criterion is proposed for deciding among alternative individualization methods. RESULTS: : Safe and effective variability defines the maximum acceptable population variability in drug concentration around the population average. CONCLUSIONS: : A decision on whether patient covariates alone are sufficient, or whether therapeutic drug monitoring in combination with target concentration intervention is needed, can be made by comparing the remaining population variability after a particular dosing method with the safe and effective variability.
Resumo:
Drug-eluting microspheres are used for embolization of hypervascular tumors and allow for local controlled drug release. Although the drug release from the microspheres relies on fast ion-exchange, so far only slow-releasing in vitro dissolution methods have been correlated to in vivo data. Three in vitro release methods are assessed in this study for their potential to predict slow in vivo release of sunitinib from chemoembolization spheres to the plasma, and fast local in vivo release obtained in an earlier study in rabbits. Release in an orbital shaker was slow (t50%=4.5h, 84% release) compared to fast release in USP 4 flow-through implant cells (t50%=1h, 100% release). Sunitinib release in saline from microspheres enclosed in dialysis inserts was prolonged and incomplete (t50%=9 days, 68% release) due to low drug diffusion through the dialysis membrane. The slow-release profile fitted best to low sunitinib plasma AUC following injection of sunitinib-eluting spheres. Although limited by lack of standardization, release in the orbital shaker fitted best to local in vivo sunitinib concentrations. Drug release in USP flow-through implant cells was too fast to correlate with local concentrations, although this method is preferred to discriminate between different sphere types.
Resumo:
We report the characterisation of 27 cardiovascular-related traits in 23 inbred mouse strains. Mice were phenotyped either in response to chronic administration of a single dose of the beta-adrenergic receptor blocker atenolol or under a low and a high dose of the beta-agonist isoproterenol and compared to baseline condition. The robustness of our data is supported by high trait heritabilities (typically H(2)>0.7) and significant correlations of trait values measured in baseline condition with independent multistrain datasets of the Mouse Phenome Database. We then focused on the drug-, dose-, and strain-specific responses to beta-stimulation and beta-blockade of a selection of traits including heart rate, systolic blood pressure, cardiac weight indices, ECG parameters and body weight. Because of the wealth of data accumulated, we applied integrative analyses such as comprehensive bi-clustering to investigate the structure of the response across the different phenotypes, strains and experimental conditions. Information extracted from these analyses is discussed in terms of novelty and biological implications. For example, we observe that traits related to ventricular weight in most strains respond only to the high dose of isoproterenol, while heart rate and atrial weight are already affected by the low dose. Finally, we observe little concordance between strain similarity based on the phenotypes and genotypic relatedness computed from genomic SNP profiles. This indicates that cardiovascular phenotypes are unlikely to segregate according to global phylogeny, but rather be governed by smaller, local differences in the genetic architecture of the various strains.
Resumo:
Therapeutic drug monitoring (TDM) can be defined as the measurement of drug in biological samples to individualise treatment by adapting drug dose to improve efficacy and/or reduce toxicity. The cytotoxic drugs are characterised by steep dose-response relationships and narrow therapeutic windows. Inter-individual pharmacokinetic (PK) variability is often substantial. There are, however, a multitude of reasons why TDM has never been fully implemented in daily oncology practice. These include difficulties in establishing appropriate concentration target, common use of combination chemotherapies and the paucity of published data from pharmacological trials. The situation is different with targeted therapies. The large interindividual PK variability is influenced by the pharmacogenetic background of the patient (e.g. cytochrome P450 and ABC transporters polymorphisms), patient characteristics such as adherence to treatment and environmental factors (drug-drug interactions). Retrospective studies have shown that targeted drug exposure correlates with treatment response in various cancers. Evidence for imatinib currently exists, others are emerging for compounds including nilotinib, dasatinib, erlotinib, sunitinib, sorafenib and mammalian target of rapamycin (mTOR) inhibitors. Applications for TDM during oral targeted therapies may best be reserved for particular situations including lack of therapeutic response, severe or unexpected toxicities, anticipated drug-drug interactions and concerns over adherence treatment. There are still few data with monoclonal antibodies (mAbs) in favour of TDM approaches, even if data showed encouraging results with rituximab and cetuximab. TDM of mAbs is not yet supported by scientific evidence. Considerable effort should be made for targeted therapies to better define concentration-effect relationships and to perform comparative randomised trials of classic dosing versus pharmacokinetically-guided adaptive dosing.