879 resultados para load bearing walls


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies of soils in Environmental Protection Areas (EPAs) are of great importance, because they are an essential component of ecosystems, directly interfering in environmental sustainability. The objective of this study was to evaluate the structural quality of soil cultivated with coffee and used as pasture in the Capituva's River microbasin, which is located in the Environmental Protection Area in Coqueiral, south of the state of Minas Gerais. Uniaxial compression test (preconsolidation test) and soil resistance to penetration were used. Undisturbed samples were taken from the surface layer (0-5 cm) of the soils in the area: a typic dystrophic Red Latosol (LVd - Oxisol), a typic eutrophic Red Argisol (PVe - Ultisol), and a typic dystrophic Haplic Cambisol (CXbd - Inceptisol). A significant linear positive correlation was observed between the results of the preconsolidation test and soil resistance to penetration. Load bearing capacity of soil could be estimated accordingly by means of penetration resistance for LVd, PVe, and CXbd. Cambisol - CXbd showed lower loading support capacity and resistance to penetration than LVd and PVe, due to the better crop management in this soil that resulted in higher physical quality which accounts for higher production and environmental sustainability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Incongruous management techniques have been associated with some significant loss of agricultural land to degradation in many parts of the world. Land degradation results in the alteration of physical, chemical and biological properties of the soil, thereby posing a serious threat to sustainable agricultural development. In this study, our objective is to evaluate the changes in a Cambisol structure under six land use systems using the load bearing capacity model. Sampling was conducted in Amazonas Region, Brazil, in the following land use: a) young secondary forest; b) old secondary forest; c) forest; d) pasture; e) cropping, and f) agroforestry. To obtain the load bearing capacity models the undisturbed soil samples were collected in those land use systems and subjected to the uniaxial compression test. These models were used to evaluate which land use system preserved or degraded the Cambisol structure. The results of the bulk density and total porosity of the soil samples were not adequate to quantify structural degradation in Cambisol. Using the forest topsoil level (0-0.03 m) as a reference, it was observed that pasture land use system was most severe in the degradation of the soil structure while the structure were most preserved under old secondary forest, cropping system and forest. At the subsoil level (0.10-0.13 m depth), the soil structure was most degraded in the cropping land use system while it was most preserved in young secondary forest and pasture. At the 0.20-0.23 m depth, soil structure degradation was most severe in the old secondary forest system and well preserved in young secondary forest, cropping and agroforestry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Highway safety and pavement performance can be directly influenced by the type of shoulders that are constructed. Shoulder design alternatives have always been rather limited. Moreover, the use of some of the alternatives has always been restricted by funding limitations. This research project seeks to explore the use of modified macadam base construction for shoulders. This type of shoulder design could offer the designer another option when paved or stabilized shoulders are being considered. Macadam base construction has in the past been shown to be quite strong and freedraining. Two macadam base shoulder designs were developed and constructed for this research project. A new roadway embankment and P.C.C. pavement were constructed on a section of US 6 east of Adel in Dallas County. The macadam base shoulders were constructed adjacent to the pavement as part of the project. The north shoulder was finished with a choke stone course and bituminous surface treatment and the south shoulder was finished with a two (2) inch layer of Type B Class II asphalt concrete. The initial results are considered satisfactory. Follow-up performance evaluation and load bearing tests are planned.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rectangular hollow section (RHS) members are components widely used in engineering applications because of their good-looking, good properties in engineering areas and inexpensive cost comparing to members with other sections. The increasing use of RHS in load bearing structures makes it necessary to analyze the fatigue behavior of the RHS members. In this thesis, concentration will be given to the fatigue behavior of the RHS members under variable amplitude pure torsional loading. For the RHS members, failure will normally occur in the corner region if the welded regions are under full penetration. This is because of the complicated stress components' distributions at the RHScorners, where all of three fracture mechanics modes will happen. Mode I is mainly caused by the residual stresses that caused by the manufacturing process. Modes II and III are caused by the applied torsional loading. Stress based Findleymodel is also used to analyze the stress components. Constant amplitude fatigue tests have been done as well as variable amplitude fatigue tests. The specimens under variable amplitude loading gave longer fatigue lives than those under constant amplitude loading. Results from tests show an S-N curvewith slope around 5.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fibre-reinforced composite (FRC) root canal posts are suggested to have biomechanical benefits over traditional metallic posts, but they lack good adhesion to resin composites. The aim of this series of studies was to evaluate the adhesion of individually formed fibre-reinforced composite material to composite resin and dentin, as well as some mechanical properties. Flexural properties were evaluated and compared between individually formed FRC post material and different prefabricated posts. The depth of polymerization of the individually formed FRC post material was evaluated with IR spectrophotometry and microhardness measurements, and compared to that of resin without fibres. Bonding properties of the individually formed FRC post to resin cements and dentin were tested using Pull-out- and Push-out-force tests, evaluated with scanning electron microscopy, and compared to those of prefabricated FRC and metal posts. Load-bearing capacity and microstrain were evaluated and failure mode assessment was made on incisors restored with individually formed FRC posts of different structures and prefabricated posts. The results of these studies show that the individually polymerized and formed FRC post material had higher flexural properties compared to the commercial prefabricated FRC posts. The individually polymerized FRC material showed almost the same degree of conversion after light polymerization as monomer resin without fibres. Moreover, it was found that the individually formed FRC post material with a semiinterpenetrating polymer network (IPN) polymer matrix bonded better to composite resin luting cement, than did the prefabricated posts with a cross-linked polymer matrix. Furthermore, it was found that, contrary to the other posts, there were no adhesive failures between the individually formed FRC posts and composite resin luting cement. This suggests better interfacial adhesion of cements to these posts. Although no differences in load-bearing capacity or microstrain could be seen, the incisors restored with individually formed FRC posts with a hollow structure showed more favourable failures compared to other prefabricated posts. These studies suggest that it is possible to use individually formed FRC material with semi-IPN polymer matrix as root canal post material. They also indicate that there are benefits especially regarding the bonding properties to composite resin and dentin with this material compared to prefabricated FRC post material with a cross-linked matrix. Furthermore, clinically more repairable failures were found with this material compared to those of prefabricated posts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tavoitteena tällä tutkimuksella on soveltaa modernin optimisuunnittelun keinoja komposiittimuovisen nestesäiliön lieriömäisen vaipparakenteen suunnittelemiseksi optimaalisen tyydyttäviksi valmistustekniikan ja kustannusten kannalta. Kuormituksia on kahdenlaisia. Säiliön sisällä on neste, joka tuottaa hydrostaattisen painekuorman ja järjestelmään kytketty puhallin tuottaa ulkoisen ylipaineen. Säiliöt ovat pystysäiliöitä ja ne tukeutuvat alustaan suoran pohjalaatan avulla. FEM- malleissa kuoren alaosat ovat jäykästi kiinnitettyjä ja yläosissa säteensuuntaiset siirtymät ovat estettyjä. Materiaaleiksi kuoreen on valittu kahdella eri menetelmällä lujitetut komposiittimateriaalit. Kantavan kerroksen toimintona on kantaa kuormat. Sulkukerros toimii korroosiosuojana ja sen lujuus on kantavaa kerrosta pienempi. Keinoina käytetään ensin innovatiivista suunnittelua optimaalisten lähtövaihtoehtojen ideoimiseksi ja valitsemiseksi jatkokehittelyä varten. Tavoitteena on asiakkaan tyytyväisyyden maksimointi huomioiden tuotteen kustannukset ja kesto. Yhtenä suunnittelun keinona on käytetty kuoriteoriaa ja komposiittien materiaalimalleja. Kestoehtoina on sovellettu komposiiteille soveltuvia kriteerejä. Toisena keinona käytetään FEM-laskentaa. Elementtityypiksi on valittu kaksiulotteinen kuorielementti, jossa on ortotrooppisen ainemallin mukaiset materiaaliominaisuudet. Jännitystuloksien merkittävyys keston kannalta selvitettiin Tsai-Hillin kriteerillä. Tuloksina saatiin ensin innovoitua rakenteelle kaksi päävaihtoehtoa, joita alettiin optimoida. Valitussa ratkaisussa on huomioitu kokonaisuus ja eri yksityiskohdat, kuten paino, jäykisteet kustannustehokkuus, valmistusnopeus, laatu, hävikit, päästöt, lujuus ja kilpailukykyinen myyntihinta. Yhteenvetona voidaan todeta, että käytetyt keinot ovat hyvin tehokkaita ja niillä voidaan suunnitella ja toteuttaa komposiittirakenteita, jotka tyydyttävät optimaalisesti loppukäyttäjän teknis- taloudelliset vaatimukset. Lisäksi tulokset osoittavat, että standardin ja FEM-laskennan ennustukset ovat lähellä toisiaan sylinterimäisillä kuoriosilla, mutta standardit suosittavat suurempia mittoja itse jäykisteille.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nykyään laivan kansirakenteet suunnitellaan pääosin kantaviksi rakenteiksi, mikä edellyttää niiltä suurta lujuutta. Jatkuvasti kasvavissa risteilijöissä ja muissa suurissa aluksissa ongelmaksi muodostuu kansirakenteiden suuret jännitykset. Kansirakenteet sijaitsevat kauimpana laivan neutraaliakselilta, jolloin niissä syntyy suuria venymiä. Kansirakenteista pitää näin ollen suunnitella hyvin kestäviä tai vaihtoehtoisesti tarpeeksi lyhyitä rakenteita. Liikuntasaumojen avulla on 1950 -luvulle asti laivoissa katkaistu pitkät kansirakenteet, mutta hitsausmenetelmien kehittyessä kansirakennukset on tehty yhtenäisiksi kansirakenteiksi. Tämä on tähänastisissa risteilijöissäkin toiminut hyvin, mutta laivojen koon kasvaessa on etsittävä keinoja mahdollisiin runkorakenteiden ja varustelun lujuus- ja väsymisongelmiin. Tavoitteena oli saada aikaan työ, joka olisi hyvä ”työkalu” tuleville tutkimuksille liikuntasaumojen soveltamisessa laivarakenteisiin sekä niihin liittyviin varusteluosiin ja -rakenteisiin. Työssä tutustutaan kirjallisuustutkimuksen avulla liikuntasaumasovelluksiin ja esitellään sovelluksia eri aloilta. Kirjallisuusosuuden päätteeksi esitellään muutama laivarakennesovellus, joita löytyy hieman vanhemmista laivarakenteista. FE analyysiosuudessa tutkitaan liikuntasauman pohjan muodon vaikutusta pohjan jännitystasoihin ja liikuntasaumojen vaikutusta laivan kansirakenteiden jännitystasoihin kolmella eri liikuntasaumojen lukumäärällä. Lisäksi kansirakenteiden jännitystasoja tutkittiin kolmella kansirakenteen leveydellä. Esimerkkejä liikuntasaumoista löytyy monelta eri aloilta, joiden ominaisuuksia yhdistelemällä saavutetaan oikea ratkaisu liikuntasaumojen soveltamisessa laivojen kansirakenteisiin. Lisäksi FE -analyysistä voidaan nähdä, että liikuntasaumat laskevat jännitystasoja laivojen kansirakenteissa. Liikuntasaumojen oikea lukumäärä riippuu hyvin paljon siitä, kuinka paljon kansirakenteen jännityksiä halutaan laskea. Liikuntasauman pohjan muotoa on kehitettävä ja se on otettava myös huomioon yhtenä tärkeänä seikkana suunniteltaessa liikuntasaumoja laivojen kansirakenteisiin. Esimerkiksi vahvistelevyillä saadaan jännityksiä laskettua liikuntasauman pohjan läheisyydessä tehokkaasti.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dentistry, yttrium partially stabilized zirconia (ZrO2) has become one of the most attractive ceramic materials for prosthetic applications. The aim of this series of studies was to evaluate whether certain treatments used in the manufacturing process, such as sintering time, color shading or heat treatment of zirconia affect the material properties. Another aim was to evaluate the load-bearing capacity and marginal fit of manually copy-milled custom-made versus prefabricated commercially available zirconia implant abutments. Mechanical properties such as flexural strength and surface microhardness were determined for green-stage milled and sintered yttrium partially stabilized zirconia after different sintering time, coloring process and heat treatments. Scanning electron microscope (SEM) was used for analyzing the possible changes in surface structure of zirconia material after reduced sintering time, coloring and heat treatments. Possible phase change from the tetragonal to the monoclinic phase was evaluated by X-ray diffraction analysis (XRD). The load-bearing capacity of different implant abutments was measured and the fit between abutment and implant replica was examined with SEM. The results of these studies showed that the shorter sintering time or the thermocycling did not affect the strength or surface microhardness of zirconia. Coloring of zirconia decreased strength compared to un-colored control zirconia, and some of the colored zirconia specimens also showed a decrease in surface microhardness. Coloring also affected the dimensions of zirconia. Significantly decreased shrinkage was found for colored zirconia specimens during sintering. Heat treatment of zirconia did not seem to affect materials’ mechanical properties but when a thin coating of wash and glaze porcelain was fired on the tensile side of the disc the flexural strength decreased significantly. Furthermore, it was found that thermocycling increased the monoclinic phase on the surface of the zirconia. Color shading or heat treatment did not seem to affect phase transformation but small monoclinic peaks were detected on the surface of the heat treated specimens with a thin coating of wash and glaze porcelain on the opposite side. Custom-made zirconia abutments showed comparable load-bearing capacity to the prefabricated commercially available zirconia abutments. However, the fit of the custom-made abutments was less satisfactory than that of the commercially available abutments. These studies suggest that zirconia is a durable material and other treatments than color shading used in the manufacturing process of zirconia bulk material does not affect the material’s strength. The decrease in strength and dimensional changes after color shading needs to be taken into account when fabricating zirconia substructures for fixed dental prostheses. Manually copy-milled custom-made abutments have acceptable load-bearing capacity but the marginal accuracy has to be evaluated carefully.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bioactive glasses (BGs) form a group of synthetic, surface-active, composition-dependent, silica-based biomaterials with osteoconductive, osteopromotive, and even angiogenic, as well as antibacterial, properties. A national interdisciplinary research group, within the Combio Technology Program (2003–2007), developed a porous load-bearing composite for surgical applications made of BG 1–98 and polymer fibers. The pre-clinical part of this thesis focused on the in vitro and in vivo testing of the composite materials in a rabbit femur and spinal posterolateral fusion model. The femur model failed to demonstrate the previously seen positive effect of BG 1–98 on osteogenesis, probably due to the changed resorption properties of BG in the form of fibers. The spine study was terminated early due to adverse events. In vitro cultures showed the growth inhibition of human mesenchymal stems next to BG 1–98 fibers and radical pH changes. A prospective, long-term, follow-up study was conducted on BG–S53P4 and autogenous bone used as bone graft substitutes for instrumented posterolateral spondylodesis in the treatment of degenerative spondylolisthesis (n=17) and unstable burst fractures (n=10) during 1996–1998. The operative outcome was evaluated from X-rays and CT scans, and a clinical examination was also performed. On the BG side, a solid fusion was observed in the CT scans of 12 patients, and a partial fusion was found in 5 patients, the result being a total fusion rate in all fusion sites (n=41) 88% for levels L4/5 and L5/S1 in the spondylolisthesis group. In the spine fracture group, solid fusion was observed in five patients, and partial fusion was found in five resulting in a total fusion rate of 71% of all fusion sites (n=21). The pre-clinical results suggest that under certain conditions the physical form of BG can be more critical than its chemical composition when a clinical application is designed. The first long-term clinical results concerning the use of BG S53P4 as bone graft material in instrumented posterolateral spondylodesis seems to be a safe procedure, associated with a very low complication rate. BG S53P4 used as a stand-alone bone substitute cannot be regarded as being as efficient as AB in promoting solid fusion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

TIIVISTELMÄ Lappeenrannan teknillinen yliopisto Konetekniikan koulutusohjelma Voitto Kettunen Konepajan hitsaustuotannon kehittäminen kattavien laatuvaatimusten mukaiseksi Diplomityö 2015 167 sivua, 39 kuvaa, 26 taulukkoa ja 3 liitettä Tarkastajat: Professori Jukka Martikainen DI Pertti Kaarre Hakusanat: hitsaus, hitsauksen laatu, konepajan laadunhallinta, kattavat laatuvaatimukset, ISO 9001, ISO 3834, EN 1090 Keywords: welding, quality of welding, engineering workshop quality management, comprehensive quality requirements, ISO 9001, ISO 3834, EN 1090 Hitsaamalla liitetyt teräksiset rakenteet muodostavat ylivoimaisesti suurimman osan konepajatuotannosta. Niihin kuuluu esimerkiksi ajoneuvoja, koneita, laitteita, säiliöitä, siiloja, siltoja, mastoja, piippuja, tukirakenteita ja rakennusten runkoja. Tämän diplomityön tavoitteena on kehittää konepajan laadunhallinta sellaiseksi, että se mahdollistaa kattavien laatuvaatimusten täyttämisen hitsaustuotannossa. Laatuvaatimusten täyttämiseen pyritään käyttämällä hitsaustoimintojen standardia EN ISO 3834-2 sekä kantavien teräsrakenteiden standardeja EN 1090-1 ja EN 1090-2. Teräsrakenteiden suunnittelua ohjaa EN 1993 ja niiden toiminnallisia ominaisuuksia tuotestandardit, kuten terässavupiippu- ja säiliöstandardit. Kantavien teräsrakenteiden suunnittelua ja tuotantoa ohjaa myös seuraamusluokan CC, käyttöluokan SC ja tuotantoluokan PC kautta määräytyvä toteutusluokka EXC. Aikaisempaa enemmän tullaan panostamaan esimerkiksi asiakirjojen sähköiseen hallintaan, raaka-aineiden jäljitettävyyteen tuotteeseen, särmien ja kulmien muotoiluun, pintojen käsittelyyn, hitsien tarkastukseen, hitsaushenkilöstön pätevyyteen ja hitsaustuotannon tehokkuuteen. Saarijärven Säiliövalmiste Oy:n hitsauksen laadunhallinta sertifioitiin standardin ISO 3834-2 mukaan ja kantavien teräsrakenteiden FPC-järjestelmä standardisarjaa EN 1090 noudattaen. Samalla tehtiin päivitys laadunhallintajärjestelmään ISO 9001. Toteutus, joka tehtiin sovitussa aikataulussa, haastaa jokaisen toimijan konepajassa toiminnan, tuotannon ja tuotteiden laadun kehittämiseen uusia käytänteitä ja menetelmiä soveltaen. Kehitystoimien tuloksena toiminta on selkeämpää, ennakoitavampaa ja hallitumpaa, mikä lisää yrityksen toiminnan tuottavuutta ja kannattavuutta. Sertifioidut laatujärjestelmät ovat myötävaikuttaneet tilausten lisääntymiseen yrityksen kaikkien tuotteiden osalta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fiber-reinforced composite fixed dental prostheses – Studies of the materials used as pontics University of Turku, Faculty of Medicine, Institute of Dentistry, Department of Biomaterials Science, Finnish Doctoral Program in Oral Sciences – FINDOS, Annales Universitatis Turkuensis, Turku, Finland 2015 Fiber-reinforced composites (FRC), a non-metallic biomaterial, represent a suitable alternative in prosthetic dentistry when used as a component of fixed dental prostheses (FDPs). Some drawbacks have been identified in the clinical performance of FRC restorations, such as delamination of the veneering material and fracture of the pontic. Therefore, the current series of studies were performed to investigate the possibilities of enhancing the mechanical and physical properties of FRC FDPs by improving the materials used as pontics, to then heighten their longevity. Four experiments showed the importance of the pontic design and surface treatment in the performance of FRC FDPs. In the first, the load-bearing capacities of inlay-retained FRC FDPs with pontics of various materials and thicknesses were evaluated. Three different pontic materials were assessed with different FRC framework vertical positioning. Thicker pontics showed increased load-bearing capacities, especially ceramic pontics. A second study was completed investigating the influence of the chemical conditioning of the ridge-lap surface of acrylic resin denture teeth on their bonding to a composite resin. Increased shear bond strength demonstrated the positive influence of the pretreatment of the acrylic surfaces, indicating dissolution of the denture surfaces, and suggesting potential penetration of the monomer systems into the surface of denture teeth. A third study analyzed the penetration depth of different monomer systems on the acrylic resin denture teeth surfaces. The possibility of establishing a durable bond between acrylic pontics and FRC frameworks was demonstrated by the ability of monomers to penetrate the surface of acrylic resin denture teeth, measured by a confocal scanning type microscope. A fourth study was designed to evaluate the load-bearing capacities of FRC FDPs using the findings of the previous three studies. In this case, the performance of pre-shaped acrylic resin denture teeth used as pontics with different composite resins as filling materials was evaluated. The filling material influenced the load-bearing capacities, providing more durable FRC FDPs. It can be concluded that the mechanical and physical properties of FRC FDPs can be improved as has been shown in the development of this thesis. The improvements reported then might provide long lasting prosthetic solutions of this kind, positioning them as potentially permanent rehabilitation treatments. Key words: fiber-reinforced composite, fixed dental prostheses, inlay-retained bridges, adhesion, acrylic resin denture teeth, dental material.