992 resultados para kerr root canal sealer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the sealing ability of different lengths of remaining root canal filling and post space preparation against coronal leakage of Enterococcus faecalis. Forty-one roots of maxillary incisors were biomechanically prepared, maintaining standardized canal diameter at the middle and coronal thirds. The roots were autoclaved and all subsequent steps were undertaken in a laminar flow chamber. The canals of 33 roots were obturated with AH Plus sealer and gutta-percha. The root canal fillings were reduced to 3 predetermined lengths (n=11): G1=6 mm, G2=4 mm and G3=2 mm. The remaining roots served as positive and negative controls. Bacterial leakage test apparatuses were fabricated with the roots attached to Eppendorf tubes keeping 2 mm of apex submerged in BHI in glass flasks. The specimens received an E. faecalis inoculum of 1 x 107 cfu/mL every 3 days and were observed for bacterial leakage daily during 60 days. Data were submitted to ANOVA, Tukey's test and Fisher's test. At 60 days, G1 (6 mm) and G2 (4 mm) presented statistically similar results (p>0.05) (54.4% of specimens with bacterial leakage) and both groups differed significantly (p<0.01) from G3 (2 mm), which presented 100% of specimens with E. faecalis leakage. It may be concluded that the shortest endodontic obturation remnant leaked considerably more than the other lengths, although none of the tested conditions avoids coronal leakage of E. faecalis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a case report of a left mandibular second premolar with three canals and three different apical foramina. A 39-year-old male patient presented to our clinic with pain in the mandibular left second premolar. Initially, pain was caused by cold stimulus and later was spontaneously. The intraoral clinical examination revealed a fractured amalgam restoration with occlusal caries. Percussion and cold (Endo-Frost) tests were positive. The radiographic examination showed the presence of two roots. The probable diagnosis was an acute pulpitis. After access cavity, it was observed remaining roof of the pulp chamber and mild bleeding in the tooth lingual area, indicating the possible presence of a third canal. The endodontic treatment was completed in a single session using Root ZX apex locator and K3 NiTi rotary system with surgical diameter corresponding to a .02/45 file in the three canals and irrigation with 1% sodium hypochlorite. The canals were obtured with gutta-percha cones and Sealer 26 using the lateral condensation technique. After 1 year of follow-up, the tooth was asymptomatic and periapical repair was observed radiographically. Internal alterations should be considered during the endodontic treatment of mandibular second premolars. The correct diagnosis of these alterations by the analysis of preoperative radiographs can help the location of two or more canals, thereby avoiding root therapy failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to test the hypothesis that dentine alterations induced by 810 nm-diode laser may affect the interaction between root canal sealers and the dentin wall. Seventy-two single root human teeth were selected and root canals were enlarged with K-files. Dentine was treated with 0.5% NaOCl and 17% EDTA-T and irradiated (laser group) by diode laser (810 nm/P = 2.5W/I = 1989 W/cm(2)) or remained non-irradiated (control group). Six samples per group were analyzed by scanning electron microscopy (SEM). The remaining samples of each group were divided into three subgroups (n = 10) and sealed with one of the tested sealers (N-Rickert/AHPlus (TM)/Apexit (R)). Apical leakage was estimated by evaluating penetration of 0.5% methylene-blue dye. SEM analysis revealed that dentine at the apical third in irradiated samples was melted and fusioned whereas non-irradiated samples exhibited opened dentinal tubules. Despite the morphological changes induced by irradiation, laser did not affect the sealing ability of N-Rickert and AHPlus (TM) sealers. However, the length of apical leakage in roots filled with Apexit (R) was lower in irradiated root canals than in non-irradiated samples (p < 0.05). Morphological changes of root canal walls promoted by diode laser irradiation may improve de sealing ability of Apexit (R), a calcium hydroxide-based sealer, suggesting that improved sealing promoted by irradiation may represent an additional factor contributing to the endodontic clinical outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim was to compare the percentage and depth of sealer penetration into dentinal tubules during obturation using Sealer 26, GuttaFlow, or Sealapex in root canals filled with the lateral compaction technique. Study design. Thirty root canals filled with the lateral compaction technique using GuttaFlow (n = 10), Sealapex (n = 10), or Sealer 26 (n = 10) were analyzed using confocal microscopy. The teeth were sectioned at 3 and 5 mm from the apex, and statistical analyses was performed using analysis of variance-Tukey test (P < .05). Results. Sealapex showed the deepest sealer penetration at both levels evaluated (P < .05). No statistically significance was found between Sealer 26 and GuttaFlow at the 3 mm and 5 mm levels. No statistical significance was found in the percentage of penetration around the root canal wall among the 3 sealers evaluated at both levels. Conclusions. Although Sealapex displayed deeper penetration into the dentinal tubules there was no difference in the percentage of adaptation to the root canal walls among the 3 sealers evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 450-457)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To assess the physicochemical properties and the surface morphology of AH Plus, GuttaFlow, RoekoSeal and Activ GP root canal sealers. Methodology Five samples of each material were evaluated for setting time, dimensional alteration, solubility and radiopacity tests, according to ANSI/ADA Specification 57. A total of 50 mL of deionized distilled water from the solubility tests were used to measure the metal solubility by atomic absorption spectrometry. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using one-way anova and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. Results AH Plus had the longest setting time (580.6 +/- 3.05 min) (P < 0.05). Activ GP did not have a mean value on the radiopacity and solubility tests (1.31 +/- 0.35 mm and 11.8 +/- 0.43%, respectively) in accordance with ANSI/ADA, being significantly different from the other materials (P < 0.05), which had mean values for these tests in accordance with the ADA`s requirements. GuttaFlow was the only sealer that conformed to the Specification 57 concerning the dimensional alteration test (0.44 +/- 0.16%) (P < 0.05). The spectrometry test revealed significant Ca2+, K+, Zn2+ ion release from Activ GP sealer (32.57 +/- 5.0, 1.57 +/- 0.22 and 8.20 +/- 1.74 mu g mL-1, respectively). In SEM analysis, the loss of matrix was evident and the filler particles were more distinguishable in all groups. Conclusions The setting time of all sealers was in accordance with ANSI/ADA`s requirements. Activ GP did not fulfill ANSI/ADA`s protocols regarding radiopacity, dimensional alteration and solubility. GuttaFlow was the only sealer that conformed to the Specification 57 in all tests. SEM analysis revealed that the surfaces of all sealers had micromorphological changes after the solubility test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study assessed in vitro the physicochemical properties of 2 methacrylate resin-based sealers (Epiphany SE and Hybrid Root SEAL), comparing the results with a well-established epoxy resin-based sealer (AH Plus). Methods: Five samples of each material were used for each test (setting time, flow, radiopacity, dimensional change after setting, and solubility) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The samples were assigned to 3 groups: I, AH Plus; II, Epiphany SE; and III, Hybrid Root SEAL. The distilled and deionized water used at the solubility test was submitted to atomic absorption spectrometry to observe the presence of Ca2+, K+, Ni2+, and Zn2+ ions. In addition, the surface morphology of the specimens was analyzed by means of scanning electron microscopy (SEM). Statistical analysis was performed by using one-way analysis of variance and Tukey-Kramer test (P < .05). Results: Flow, radiopacity, and solubility of all sealers were in accordance with ANSI/ADA. The setting time of Hybrid Root SEAL did not agree with ANSUADA requirements. The dimensional change of all sealers was greater than the values considered acceptable by ANSI/ADA. The spectrometry analysis showed significant Ca2+ ions release for AH Plus. In SEM analysis, Hybrid Root SEAL presented spherical monomers with inferior size than AH Plus and Epiphany SE. Conclusions: It might be concluded that physicochemical properties of the tested sealers conformed to ANSI/ADA (2000) standardization, except for the setting time of Hybrid Root SEAL and the dimensional change of all sealers, which did not fulfill the ANSI/ADA requirements. (J Endod 2010;36:1531-1536)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To assess the push-out strength of Epiphany SE, Epiphany and Hybrid Root SEAL to the dentine walls of root canals. Methodology Sixty roots of canines were prepared and distributed to six groups (n = 10) according to the filling material: GI - Epiphany SE, GII - Epiphany primer and sealer, GIII - Epiphany primer, sealer and resinous solvent, GIV - Clearfil DC Bond and Epiphany sealer, GV - Clearfil, Epiphany sealer and solvent and GVI - Hybrid Root SEAL. Resilon cones were used in all groups. Roots were sectioned transversally to obtain three slices from each third. One slice was subjected to the push-out test (MPa), and results were analysed by anova and Tukey`s test (P < 0.05). The other two slices were prepared for scanning electron microscopy (SEM). Failure mode was also analysed. Results A statistically significant difference (P < 0.05) occurred between Hybrid Root SEAL (5.27 +/- 2.07) and the other materials, GI (0.40 +/- 0.23), GII (0.78 +/- 0.45), GIII (0.57 +/- 0.28), GIV (0.40 +/- 0.24) and GV (0.50 +/- 0.41), which did not differ significantly from each other (P > 0.05). Adhesive failures predominated in groups I, II, IV and V, whilst mixed and cohesive failures were the most frequent in groups III and VI, respectively. There were gaps in the adhesive interface of GI and GII, continuity areas of the filling material with dentine in GIV and GV and good adaptation of the interface of GVI. Conclusion Hybrid Root SEAL had greater push-out strength to root canal dentine than Epiphany SE and Epiphany. The use of primer, solvent and adhesive system did not influence the adhesion of Epiphany.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To assess the physicochemical properties and the surface morphology of AH Plus, Epiphany, and Epiphany SE root canal sealers. Methodology Five samples of each material were employed for each test according to ANSI/ADA specification 57. The samples were assigned to four groups: (i) AH Plus; (ii) Epiphany; (iii) Epiphany + Thinning Resin; (iv) Epiphany SE. The distilled water used during the solubility test was submitted to spectrometry to verify the release of calcium ions. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using One-Way anova and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. Results Setting time, flow and radiopacity results were in accordance with ANSI/ADA requirements whereas the dimensional change of all sealers and solubility of Epiphany did not fulfil ANSI/ADA protocols. AH Plus and Epiphany SE were similar in terms of flow, radiopacity, solubility and dimensional change. The spectrometry test revealed significant calcium ion release from Epiphany with and without the thinning resin. SEM analysis revealed essentially a homogeneous surface with compact layer and some rough areas. Conclusions Setting time, flow, and radiopacity tests conformed to ANSI/ADA standardization. The dimensional change in all groups and the solubility of Epiphany were greater than values considered acceptable, with higher amounts of calcium ion release. Epiphany SE revealed more organized, compacted, and homogeneous polymers in a reduced resin matrix when compared with the other groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the study was to evaluate the biocompatibility of RoekoSeal sealer Roeko (Dental Products, Langenau, Germany) with the periapical tissues of dogs and compare it with AH Plus sealer (Dentsply/De Trey, Konstanz, Germany). The pulps of 32 root canals were removed, the apical cementum layer perforated, the biomechanical preparation performed, and the root canals filled by lateral condensation technique. Ninety days after the surgery, the animals were euthanized, the bone with teeth removed, and the samples prepared for histopathological analysis. In group 1 (RoekoSeal Automix), deposition of mineralized tissue was observed, with complete newly mineralized apical formed tissue in 43.8% and partial sealing in 56.2%. In group 2 (AH Plus), in 12.5% there was complete newly mineralized apical formed tissue, in 75% the sealing was partial, and in 12.5% there was no sealing (p < 0.05). There were no differences between the groups in relation to the inflammatory infiltrate; thickness of the periodontal ligament; and the resorption of dentin, cementum or bone (p > 0.05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foi propósito deste trabalho observar o processo de reparo de dentes de cães após obturação dos canais com dois cimentos diferentes, fazendo ou não a patência apical. Após uma sobreinstrumentação, os canais receberam um curativo de uma solução de corticosteróide-antibiótico por 7 dias, com o objetivo de obter invaginação de tecido conjuntivo para dentro dos canais. Após esse período, esse tecido foi totalmente removido em metade dos casos (grupos com patência apical) e preservados no restante dos casos (grupos sem patência apical). Os canais foram obturados pela técnica da condensação lateral empregando um cimento a base de hidróxido de cálcio (Sealer Plus) ou um cimento de Grossman (Fill Canal). Os animais foram sacrificados por overdose anestésica 60 dias após o tratamento endodôntico e as peças anatômicas foram obtidas e preparadas para análise histológica. Os dados obtidos foram analisados com base em diversos parâmetros histomorfológicos. Os resultados foram melhores nos grupos sem patência apical (p=0,01) do que nos grupos com patência. Dentre os cimentos estudados, os melhores resultados foram observados com o cimento Sealer Plus (p=0,01). em conclusão, tanto a patência apical (presença ou ausência) quanto o tipo de material obturador de canal influíram no processo de reparo apical de dentes de cães com polpas vitais após tratamento endodôntico. O emprego de um cimento a base de hidróxido de cálcio em dentes sem patência apical promoveu os melhores resultados, dentre as condições experimentais propostas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the response of periapical tissues to the endodontic sealer EndoREZ in root canal fillings short of or beyond the apical foramenlike communication. Twenty root canals of premolars and incisors of 2 mongrel dogs were used. After coronal access and pulp extirpation, the canals were instrumented up to a size 55 K-file and the apical cemental barrier was penetrated with a size 15 K-file to create an apical foramenlike communication, which was widened to a size 25 K-file. The canals were irrigated with saline at each change of file. The root canals were obturated either short of or beyond the apical foramenlike opening by the lateral condensation of gutta-percha and EndoREZ, originating 2 experimental groups: G1, EndoREZ/short of the apical foramenlike opening, and G2, EndoREZ/beyond the apical foramenlike opening. The animals were killed by anesthetic overdose 90 days after endodontic treatment. The individual roots were obtained and serial histological sections were prepared for histomorphological analysis (H&E and Brown and Brenn techniques) under light microscopy. The following parameters were examined: closure of the apical foramenlike communication and apical opening of accessory canals, apical cementum resorptions, intensity of the inflammatory infiltrate, presence of giant cells, and thickness and organization of the apical periodontal ligament. Each parameter was scored 1 to 4, 1 being the best result and 4 the worst. Data were analyzed statistically by the Wilcoxon nonparametric tests (P = .05). Comparing the 2 groups, the best result (P = .05) was obtained with root canal filling with EndoREZ short of the apical foramenlike opening. In conclusion, limiting the filling material to the root canal space apically was important to determine the best treatment outcome when EndoREZ was used as the sealer. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e94-e99)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. METODOLOGIA: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. RESULTADOS: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. CONCLUSÃO: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this ex vivo study was to evaluate bacterial penetration after filling root canals using 3 different techniques. Three experimental groups of 25 teeth each, obturated with lateral-warm-vertical condensation of gutta-percha, Microseal technique and EndoREZ (R) system, respectively, were tested in a split chamber model system using Enterococcus faecalis and monitored for 180 days to determine bacterial penetration. A statistical analysis was performed using the Kaplan-Meier method. Median survival time was 25 days for Microseal system, 41 for lateral-warm-vertical condensation and 81 for EndoREZ (R). Significant differences were demonstrated between Microseal and EndoREZ (R) (p<0.001) and between Microseal and lateral-warm-vertical condensation technique (p<0.05). No statistically significant differences were observed between EndoREZ (R) and lateral-warm-vertical condensation. After 180 days of assessment, 20% of the EndoREZ (R) samples resisted bacterial penetration and furthermore, the EndoREZ (R) system has the potential to be a filler system compatible with other currently used systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)