989 resultados para joint motion sense
Resumo:
Acuity for elbow joint position sense (JPS) is reduced when head position is modified. Movement of the head is associated with biomechanical changes in the neck and shoulder musculoskeletal system, which may explain changes in elbow JPS. The present study aimed to determine whether elbow JPS is also influenced by illusory changes in head position. Simultaneous vibration of sternocleidomastoid (SCM) and the contralateral splenius was applied to 14 healthy adult human subjects. Muscle vibration or passive head rotation was introduced between presentation and reproduction of a target elbow position. Ten out of 14 subjects reported illusions consistent with lengthening of the vibrated muscles. In these 10 subjects, absolute error for elbow JPS increased with left SCM/right splenius vibration but not with right SCM/left splenius vibration. Absolute error also increased with right rotation, with a trend for increased error with left rotation. These results demonstrated that both actual and illusory changes in head position are associated with diminished acuity for elbow JPS, suggesting that the influence of head position on upper limb JPS depends, at least partially, on perceived head position.
Resumo:
Introduction: Kinesio Taping (KT) has been used in healthy people to improve neuromuscular performance, however, few studies have evaluated its chronic effects, despite being suggested. Objective: To analyze the chronic effects of KT on neuromuscular performance of the quadriceps, the oscillation of the center of pressure and lower limb function in healthy women. Methods: blinded, randomized, controlled trial, composed of 60 women (mean age 21.9 ± 3.3 years and BMI 22.3 ± 2.2 kg / m2) submitted to the evaluation of oscillation of the center of pressure through the baropodometry, the lower limb function by the hop test, isokinetic knee performance, the electromyographic activity of the vastus lateralis (VL) and joint position sense of the knee (JPS). Then, participants were randomly divided into three groups of twenty: control - did not apply the KT; placebo - application of KT without tension on the quadriceps; Kinesio Taping - application of KT with tension in the same muscle group. The evaluations were conducted in five moments: prior to application of KT, immediately after the application, 24h, 48h after application and 24 hours after its removal (72h). SPSS 20.0 was used for statistical analysis. The KS test was used to verify the data normality, the Levene test for homogeneity of variances and a mixed-model ANOVA 3x5 to check intra and inter-group differences. Results: there was no difference in peak torque, the power, nor the electromyographic activity or SPA (p> 0.05) between groups. The displacement speed of center of pressure reduced immediately after the application on kinesio taping group (p <0.001), but with no differences between the groups (p = 0.28). There was a reduction in the time of peak torque among the three groups in the evaluations after KT application (p <0.001) and an increase in single hop in all groups (p <0.001), but with no differences between them. Conclusion: KT can not change, in a chronic way, the lower limb function, the oscillation of the center of pressure, the isokinetic performance, the JPS of the knee and the electromyographic activity of VL muscle in healthy women.
Resumo:
Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.
Resumo:
Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.
Resumo:
Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.
Resumo:
Background: Hamstring strain injuries (HSI) are one of the most common injuries in a wide variety of running-sports, resulting in a considerable loss of competition and training time. One of the most problematic consequences regarding HSI is the recurrence rate and its non-decrease over the past decades, despite increasing evidence. Recent studies also found several maladaptations post-HSI probably due to neuromuscular inhibition and it has been proposed that these adaptations post-injury may contribute as risk factors for the injury-reinjury cycle and high recurrence rates. Furthermore it has been recently proposed not to disregard the inter-relationship between these adaptations and risk-factors post-injury in order to better understand the mechanisms of this complex injury. Objective: To determine, analyze and correlate neuromuscular adaptations in amateur football players with prior history of HSI per comparison to uninjured athletes in similar conditions. Methodology: Every participant was subjected to isokinetic concentric (60 and 240deg.sec) and eccentric (30 and 120deg.sec¯¹) testing, and peak torque, angle of peak torque and hamstrings to quadriceps (H:Q) conventional ratios were measured, myoelectrical activity of Bicep Femoris (BF) and Medial Hamstrings (MH) were also measured during isokinetic eccentric testing at both velocities and muscle activation percentages were calculated at 30, 50 and 100ms after onset of contraction. Furthermore active and passive knee extension, knee joint position sense (JPS) test, triple-hop distance (THD) test and core stability (flexors and extensors endurance, right and left side bridge test) were used and correlated. Results: Seventeen players have participated in this study: 10 athletes with prior history of HSI, composing the Hamstring injury group (HG) and 7 athletes without prior severe injuries as control group (CG). We found statistical significant differences between HG injured and uninjured sides in the BF myoelectrical activity at almost all times in both velocities and between HG injured and CG non-dominant sides at 100ms in eccentric 120deg.sec¯¹ velocity (p<.05). We found no differences in MH activity. Regarding proprioception we found differences between the HG injured and uninjured sides (p=.027). We found no differences in the rest of used tests. However, significant correlation between myoelectrical activation at 100ms in 120deg.sec¯¹ testing and JPS with initial position at 90º (r-.372; p=0.031) was found, as well as between isokinetic H:Q ratio at 240deg.sec and THD score (r=-.345; p=.045). Conclusion: We found significant differences that support previous research regarding neuromuscular adaptations and BF inhibition post-HSI. Moreover, to our knowledge, this was the first study that found correlation between these adaptations, and may open a door to new perspectives and future studies.
Resumo:
Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.
Resumo:
Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciado em Fisioterapia
Resumo:
Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciada em Fisioterapia
Resumo:
The trajectory planning of redundant robots is an important area of research and efficient optimization algorithms are needed. The pseudoinverse control is not repeatable, causing drift in joint space which is undesirable for physical control. This paper presents a new technique that combines the closed-loop pseudoinverse method with genetic algorithms, leading to an optimization criterion for repeatable control of redundant manipulators, and avoiding the joint angle drift problem. Computer simulations performed based on redundant and hyper-redundant planar manipulators show that, when the end-effector traces a closed path in the workspace, the robot returns to its initial configuration. The solution is repeatable for a workspace with and without obstacles in the sense that, after executing several cycles, the initial and final states of the manipulator are very close.
Resumo:
Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presentsan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.
Resumo:
Patients after Legg-Calvé-Perthes disease (LCPD) often develop pain, impaired ROM, abductor weakness, and progression of osteoarthritis (OA) in early adulthood. Based on intraoperative observations during surgical hip dislocation, we established an algorithm for more detailed characterization of the underlying pathomorphologies with a proposed joint-preserving surgical treatment.