910 resultados para joint invariant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional approaches to joint control required accurate modelling of the system dynamic of the plant in question. Fuzzy Associative Memory (FAM) control schemes allow adequate control without a model of the system to be controlled. This paper presents a FAM based joint controller implemented on a humanoid robot. An empirically tuned PI velocity control loop is augmented with this feed forward FAM, with considerable reduction in joint position error achieved online and with minimal additional computational overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The GuRoo is a 1.2 m tall, 23 degree of freedom humanoid constructed at the University of Queensland for research into humanoid robotics. The key challenge being addressed by the GuRoo project is the development of appropriate learning strategies for control and coordination of the robot's many joints. The development of learning strategies is seen as a way to side-step the inherent intricacy of modeling a multi-DOF biped robot. This paper outlines the approach taken to generate an appropriate control scheme for the joints of the GuRoo. The paper demonstrates the determination of local feedback control parameters using a genetic algorithm. The feedback loop is then augmented by a predictive modulator that learns a form of feed-forward control to overcome the irregular loads experienced at each joint during the gait cycle. The predictive modulator is based on the CMAC architecture. Results from tests on the GuRoo platform show that both systems provide improvements in stability and tracking of joint control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the influence of pH on interfacial energy distributed over the phospholipids-bilayer surface model and the effect of hydrophobicity on coefficient of friction (f) were investigated by using microelectrophoresis. An important clinical implication of deficiency in hydrophobicity is the loss of phospholipids that is readily observed in osteoarthritis joints. This paper establishes the influence of pH on interfacial energy upon an increase f, which might be associated with a decrease of hydrophobicity of the articular surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The temporomandibular joint (TMJ) cartilage consists of condylar cartilage and disc and undergoes continuous remodeling throughout post-natal life. To maintain the integrity of the TMJ cartilage, anti-angiogenic factors play an important role during the remodeling process. In this study, we investigated the expression of the anti-angiogenic factor, chondromodulin- 1 (ChM-1), in TMJ cartilage and evaluate its potential role in TMJ remodeling. METHODS: Eight TMJ specimens were collected from six 4-month-old Japanese white rabbits. Safranin-O staining was performed to determine proteoglycan content. ChM-1 expression in TMJ condylar cartilage and disc was determined by immunohistochemistry. Three human perforated disc tissue samples were collected for investigation of ChM-1 and vascular endothelial growth factor (VEGF) distribution in perforated TMJ disc. RESULTS: Safranin-O stained weakly in TMJ compared with tibial articular and epiphyseal cartilage. In TMJ, ChM-1 was expressed in the proliferative and hypertrophic zone of condylar cartilage and chondrocyte-like cells in the disc. No expression of ChM-1 was observed in osteoblasts and subchondral bone. ChM-1 and VEGF were both similarly expressed in perforated disc tissues. CONCLUSIONS: ChM-1 may play a role in the regulation of TMJ remodeling by preventing blood vessel invasion of the cartilage, thereby maintaining condylar cartilage and disc integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of an ongoing research on the development of a longer life insulated rail joint (IRJ), this paper reports a field experiment and a simplified 2D numerical modelling for the purpose of investigating the behaviour of rail web in the vicinity of endpost in an insulated rail joint (IRJ) due to wheel passages. A simplified 2D plane stress finite element model is used to simulate the wheel-rail rolling contact impact at IRJ. This model is validated using data from a strain gauged IRJ that was installed in a heavy haul network; data in terms of the vertical and shear strains at specific positions of the IRJ during train passing were captured and compared with the results of the FE model. The comparison indicates a satisfactory agreement between the FE model and the field testing. Furthermore, it demonstrates that the experimental and numerical analyses reported in this paper provide a valuable datum for developing further insight into the behaviour of IRJ under wheel impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obese children move less and with greater difficulty than normal-weight counterparts but expend comparable energy. Increased metabolic costs have been attributed to poor biomechanics but few studies have investigated the influence of obesity on mechanical demands of gait. This study sought to assess three-dimensional lower extremity joint powers in two walking cadences in 28 obese and normal-weight children. 3D-motion analysis was conducted for five trials of barefoot walking at self-selected and 30% greater than self-selected cadences. Mechanical power was calculated at the hip, knee, and ankle in sagittal, frontal and transverse planes. Significant group differences were seen for all power phases in the sagittal plane, hip and knee power at weight acceptance and hip power at propulsion in the frontal plane, and knee power during mid-stance in the transverse plane. After adjusting for body weight, group differences existed in hip and knee power phases at weight acceptance in sagittal and frontal planes, respectively. Differences in cadence existed for all hip joint powers in the sagittal plane and frontal plane hip power at propulsion. Frontal plane knee power at weight acceptance and sagittal plane knee power at propulsion were significantly different between cadences. Larger joint powers in obese children contribute to difficulty performing locomotor tasks, potentially decreasing motivation to exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inspection of solder joints has been a critical process in the electronic manufacturing industry to reduce manufacturing cost, improve yield, and ensure product quality and reliability. The solder joint inspection problem is more challenging than many other visual inspections because of the variability in the appearance of solder joints. Although many research works and various techniques have been developed to classify defect in solder joints, these methods have complex systems of illumination for image acquisition and complicated classification algorithms. An important stage of the analysis is to select the right method for the classification. Better inspection technologies are needed to fill the gap between available inspection capabilities and industry systems. This dissertation aims to provide a solution that can overcome some of the limitations of current inspection techniques. This research proposes two inspection steps for automatic solder joint classification system. The “front-end” inspection system includes illumination normalisation, localization and segmentation. The illumination normalisation approach can effectively and efficiently eliminate the effect of uneven illumination while keeping the properties of the processed image. The “back-end” inspection involves the classification of solder joints by using Log Gabor filter and classifier fusion. Five different levels of solder quality with respect to the amount of solder paste have been defined. Log Gabor filter has been demonstrated to achieve high recognition rates and is resistant to misalignment. Further testing demonstrates the advantage of Log Gabor filter over both Discrete Wavelet Transform and Discrete Cosine Transform. Classifier score fusion is analysed for improving recognition rate. Experimental results demonstrate that the proposed system improves performance and robustness in terms of classification rates. This proposed system does not need any special illumination system, and the images are acquired by an ordinary digital camera. In fact, the choice of suitable features allows one to overcome the problem given by the use of non complex illumination systems. The new system proposed in this research can be incorporated in the development of an automated non-contact, non-destructive and low cost solder joint quality inspection system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The joints of a humanoid robot experience disturbances of markedly different magnitudes during the course of a walking gait. Consequently, simple feedback control techniques poorly track desired joint trajectories. This paper explores the addition of a control system inspired by the architecture of the cerebellum to improve system response. This system learns to compensate the changes in load that occur during a cycle of motion. The joint compensation scheme, called Trajectory Error Learning, augments the existing feedback control loop on a humanoid robot. The results from tests on the GuRoo platform show an improvement in system response for the system when augmented with the cerebellar compensator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The standard treatment for a non-union of the hallux metatarsophalangeal joint fusion has been to revise the fusion. Revision fusion is technically more demanding, often involving bone grafting, more substantial fixation and prolonged period of immobilization postoperatively. We present data to suggest that removal of hardware and debridement alone is an alternative treatment option. ---------- MATERIALS AND METHODS: A case note review identified patients with a symptomatic non-union after hallux metatarsophalangeal joint (MTPJ) fusion. It is our practice to offer these patients revision fusion or removal of hardware and debridement. For the seven patients that chose hardware removal and were left with a pseudarthrosis, a matched control group was selected from patients who had had successful fusions. Three outcome scores were used. Hallux valgus and dorsiflexion angles were recorded.---------- RESULTS: One hundred thirty-nine hallux MTPJ arthrodeses were carried out. Fourteen non-unions were identified. The rate of non-union in males and following previous hallux MTPJ surgery was 19% and 24%, respectively. In females undergoing a primary MTPJ fusion, the rate was 2.4%. Twelve non-union patients were reviewed at 27 months (mean). Eleven patients had elected to undergo removal of hardware and debridement. Four patients with pseudarthrosis were unhappy with the results and proceeded to either revision fusion or MTPJ replacement. Seven non-union patients, who had removal of hardware alone, had outcome scores marginally worse compared to those with successful fusions.---------- CONCLUSION: Removal of hardware alone is a reasonable option to offer as a relatively minor procedure following a failed arthrodesis of the first MTPJ. This must be accepted on the proviso that in this study four out of 11 (36%) patients proceeded to a revision first MTPJ fusion or first MTPJ replacement. We also found that the rate of non-union in primary first MTPJ fusion was significantly higher in males and those patients who had undergone previous surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A finite element numerical simulation is carried out to examine stress distributions on railhead in the cicinity of the endpost of an insulated rail joint. The contact patch and pressure distribution are considered using modified Hertzian simulation. A combined elasto-plastic material modelling available in Abaqus is employed in the simulation. A dynamic load factor of 1.21 is considered in modelling for the wheel load based on a previous study as part of this on going research. Shakedown theorem is employed in this study. A peak pressure load which is above the shakedown limit is determined as input load. As a result, a progressive damage in the railhead has been captured as depicted in the equivalent plastic strain plot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: The appropriate fixation method for hemiarthroplasty of the hip as it relates to implant survivorship and patient mortality is a matter of ongoing debate. We examined the influence of fixation method on revision rate and mortality.----- ----- Methods: We analyzed approximately 25,000 hemiarthroplasty cases from the AOA National Joint Replacement Registry. Deaths at 1 day, 1 week, 1 month, and 1 year were compared for all patients and among subgroups based on implant type.----- ----- Results: Patients treated with cemented monoblock hemiarthroplasty had a 1.7-times higher day-1 mortality compared to uncemented monoblock components (p < 0.001). This finding was reversed by 1 week, 1 month, and 1 year after surgery (p < 0.001). Modular hemiarthroplasties did not reveal a difference in mortality between fixation methods at any time point.----- ----- Interpretation: This study shows lower (or similar) overall mortality with cemented hemiarthroplasty of the hip.