990 resultados para joint function
Resumo:
Introduction: Indications for arthrodesis of the first metatarsophalangeal joint (MTP1) are commonly arthrosis (hallux rigidus), rheumatoid arthritis, failed hallux valgus surgery, severe hallux valgus, infectious arthritis, fractures and neuroarthropathies. Many reports focus on technical and radiological issues but few studies emphasize the functional outcome considering daily activities, sports and expectation of the patient. Method: We retrospectively reviewed the patients who underwent MTP1-arthrodesis from 2002 to 2005 in our institution. Clinical and radiological results were assessed but we specially focussed on the functional outcome. Scoring systems used were the SF-12, EQ-5D, PASI, FFI and AOFAS (10 points given to MTP1 mobility) scales. Results: 61 of 64 consecutive patients were evaluated. Female to male ratio was 49:15, mean age at surgery was 67 years, the average follow up was 29 month. Even if radiological consolidation was incomplete in 18 patients, all patients had a clinically stable and rigid arthrodesis. Mean AOFAS score was 87 (24-100) points at follow up. The FFI was 5.91% (0-66%). Patient satisfaction was excellent in 37 patients (60%), good in 18 (30%), fair in 5(8%) and poor in1 (2%). EQ- 5D was 0.7 (0.4-1).40 patients (66%) estimated their cosmetic result as excellent, 15 (25%) as good, 4(6%) as fair and 2 (3%)as poor. 10 patients (16%) had no shoe wear limitation , 48 (79%) had to wear comfortable shoes and 3 (5%) needed orthopaedic wearing. Professionally 34 patients (56%) had better performances, 18 (26%) had no change and 9 (18%) had aggravation of their capacities but this was due to other health reasons. In sports, 16 patients (26%) had better performances, 35 patients (57%) no change and 10 (17%) were worse as consequence of other health problems for 7. Finally, 56 patients (92%) would recommend the operation and 5 (8%) would not. Conclusion: Experience of clinical practice suggests that the idea of fusing the first MTP joint is initially frequently disregarded by the patients because they fear to be limited by a rigid forefoot. Our results show, in fact, that this procedure can be proposed for numerous pathological situations with the perspective of good to excellent outcome in terms of function and quality of life in the majority of cases.
Resumo:
Background: Transcatheter aortic valve implantations (TAVI) are indicated in high risk patients requiring aortic valve replacement (AVR). However, CT-scans, coronary angiograms and intraoperative aortographies can induce contrast-related nephro-toxicity with a concrete risk of acute postoperative renal failure, especially in severely diseased patients. To prevent this complication, we routinely perform transapical (TA) TAVI guided by transesophageal echocardiogram and fluoroscopy without angiography. Material and Methods: From November 2008 to December 2009, 31 high-risk patients suffering from severe symptomatic aortic stenosis underwent TA-TAVI in our institution. The preoperative imaging assessment (cardiac CT-scan and coronary angiogram) was performed no less than 10 days before the TA-TAVI in all patients (to recover the renal function) with a low-dose protocol for injected contrast medium (equivalent to the patient's weight for the CT-scan). During the TA-TAVI, the stent-valve positioning was performed without any contrast injection. Results: 32 consecutive stent-valve were successfully positioned in 31 patients (mean age 80.76 8 8.3 years; mean EuroSCORE: 32.2 8 12.9%) through a transapical access (1 patient required 2 valves for valve embolisation). The mean preoperative creatinine and urea blood levels were 102.6 8 67.7 _ g/dl (range 53-339 _ g/dl) and 8.45 8 4.9 mmol/l, respectively. A chronic renal insufficiency affected 12 patients (38.7%) with 1 patient in pre-dialysis. Postoperatively, no patient developed acute myocardial infarction, atrio-ventricular block or acute renal insufficiency (mean creatinine level: 89.7 8 64.55 _ g/dl; urea level: 7.11 8 3.47 mmol/l) and the 30-days mortality was 9.67% (3 patients). Conclusion: Specific preoperative and intraoperative protocols that require lowdoses or absence of contrast medium are useful to preserve the renal function in high risk patients operated for TAVI.
Resumo:
Summary The NACHT, LRR and PYD domains containing protein (NALP3) inflammasome is a key regulator of interleukin-1beta (IL-1beta) secretion. As there is strong evidence for a pro-inflammatory role of IL-1beta in rheumatoid arthritis (RA) and in murine models of arthritis, we explored the expression of the different components of the NALP3 inflammasome as well as other nucleotide oligomerization domain (NOD)-like receptors (NLRs) in synovium obtained from patients with RA. The expression of NLRs was also studied in fibroblast lines derived from joint tissue. By immunohistology, NALP3 and apoptosis-associated speck-like protein containing a CARD domain (ASC) were expressed in myeloid and endothelial cells and B cells. T cells expressed ASC but lacked NALP3. In synovial fibroblast lines, NALP3 expression was not detected at the RNA and protein levels and stimulation with known NALP3 agonists failed to induce IL-1beta secretion. Interestingly, we were unable to distinguish RA from osteoarthritis synovial samples on the basis of their basal level of RNA expression of known NLR proteins, though RA samples contained higher levels of caspase-1 assayed by enzyme-linked immunsorbent assay. These results indicate that myeloid and endothelial cells are the principal sources of inflammasome-mediated IL-1beta production in the synovium, and that synovial fibroblasts are unable to activate caspase-1 because they lack NALP3. The NALP3 inflammasome activity does not account for the difference in level of inflammation between RA and osteoarthritis.
Resumo:
In a prospective study the functional results after dissection or preservation of the serratus anterior muscle in the postero-lateral standard thoracotomy were evaluated. In 14 patients of our clinic with dissection and suture and in 14 patients with preservation of the serratus muscle the muscle function was assessed and compared preoperatively, within the first two post-operative weeks, and three months after the operation by the same physiotherapists. The two groups were blinded in regard to age, original disease, and mode of intervention. We compared the wing position of the scapula in the sitting position and the positioning of the scapula at fixation of the shoulder joint in the sitting and in the supine position. Using a four-grade function assessment scheme, both groups obtained the same functional results. There was no seroma in either group. After 2.8 (2.5 to 3.0) years all the surviving patients described symmetric functional conditions. We therefore conclude that in order to achieve a better view of the operative field the serratus muscle may be dissected close to the origin if it is then readapted.
Resumo:
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.
Resumo:
Partial trapeziectomy with suspension ligamentoplasty is a commonly performed treatment of thumb osteoarthritis. Nevertheless, the post-operative recovery remains long and critical reason for which different modifications of the surgical technique have been proposed. To compare two suspension ligamentoplasty techniques, one with a mitek anchor and another without, a retrospective study of 55 consecutive operated patients was performed. A detailed clinical analysis of pain, function and a radiologic assessment of the trapeziometacarpal space were performed. Mitek anchor fixation was associated with a shorter convalescence period. However, in spite of an improved radiological maintenance of the scaphometacarpal space, mitek anchor fixation was associated with an impaired postoperative function and residual pain when compared with the conventional suspension ligamentoplasty procedure. Patient's satisfaction was comparable in both groups. In our series stabilization of the suspension ligamentoplasty procedure by the insertion of a mitek anchor did not bring the hoped benefits to the patients with a trapeziometacarpal arthritis.
Resumo:
The Saccharomyces cerevisiae Dmc1 and Tid1 proteins are required for the pairing of homologous chromosomes during meiotic recombination. This pairing is the precursor to the formation of crossovers between homologs, an event that is necessary for the accurate segregation of chromosomes. Failure to form crossovers can have serious consequences and may lead to chromosomal imbalance. Dmc1, a meiosis-specific paralog of Rad51, mediates the pairing of homologous chromosomes. Tid1, a Rad54 paralog, although not meiosis-specific, interacts with Dmc1 and promotes crossover formation between homologs. In this study, we show that purified Dmc1 and Tid1 interact physically and functionally. Dmc1 forms stable nucleoprotein filaments that can mediate DNA strand invasion. Tid1 stimulates Dmc1-mediated formation of joint molecules. Under conditions optimal for Dmc1 reactions, Rad51 is specifically stimulated by Rad54, establishing that Dmc1-Tid1 and Rad51-Rad54 function as specific pairs. Physical interaction studies show that specificity in function is not dictated by direct interactions between the proteins. Our data are consistent with the hypothesis that Rad51-Rad54 function together to promote intersister DNA strand exchange, whereas Dmc1-Tid1 tilt the bias toward interhomolog DNA strand exchange.
Resumo:
Bridge expansion joints, if not properly designed, constructed, and maintained, often lead to the deterioration of critical substructure elements. Strip seal expansion joints consisting of a steel extrusion and neoprene gland are one type of expansion joint and are commonly used by the Iowa Department of Transportation (DOT). Strip seal expansion joints are susceptible to tears and pull outs that allow water, chlorides, and debris to infiltrate the joint, and subsequently the bearings below. One area of the strip seal that is particularly problematic is where it terminates at the interface between the deck and the barrier rail. The Iowa DOT has noted that the initial construction quality of the current strip seal termination detail is not satisfactory, nor ideal, and a need exists for re-evaluation and possibly re-design of this detail. Desirable qualities of a strip seal termination detail provide a seal that is simple and fast to construct, facilitate quick gland removal and installation, and provide a reliable, durable barrier to prevent chloride-contaminated water from reaching the substructure. To meet the objectives of this research project, several strip seal termination details were evaluated in the laboratory. Alternate termination details may not only function better than the current Iowa DOT standard, but are also less complicated to construct, facilitating better quality control. However, uncertainties still exist regarding the long-term effects of using straight-through details, with or without the dogleg, that could not be answered in the laboratory in the short time frame of the research project.
Resumo:
The alteration in neuromuscular function of knee extensor muscles was characterised after a squash match in 10 trained players. Maximal voluntary contraction (MVC) and surface EMG activity of vastus lateralis (VL) and vastus medialis (VM) muscles were measured before and immediately after a 1-h squash match. M-wave and twitch contractile properties were analysed following single stimuli. MVC declined (280.5+/-46.8 vs. 233.6+/-35.4 Nm, -16%; P<0.001) after the exercise and this was accompanied by an impairment of central activation, as attested by decline in voluntary activation (76.7+/-10.4 vs. 71.3+/-9.6%, -7%; P<0.05) and raw EMG activity of the two vastii (-17%; P<0.05), whereas RMS/M decrease was lesser (VL: -5%; NS and VM: -12%; P=0.10). In the fatigued state, no significant changes in M-wave amplitude (VL: -9%; VM: -5%) or duration were observed. Following exercise, the single twitch was characterised by lower peak torque (-20%; P<0.001) as well as shorter half-relaxation time (-13%; P<0.001) and reduced maximal rate of twitch tension development (-23%; P<0.001) and relaxation (-17%; P<0.05). A 1-h squash match play caused peripheral fatigue by impairing excitation-contraction coupling, whereas sarcolemmal excitability seems well preserved. Our results also emphasise the role of central activation failure as a possible mechanism contributing to the torque loss observed in knee extensors. Physical conditioners should consider these effects when defining their training programs for squash players.
Resumo:
Probabilistic inversion methods based on Markov chain Monte Carlo (MCMC) simulation are well suited to quantify parameter and model uncertainty of nonlinear inverse problems. Yet, application of such methods to CPU-intensive forward models can be a daunting task, particularly if the parameter space is high dimensional. Here, we present a 2-D pixel-based MCMC inversion of plane-wave electromagnetic (EM) data. Using synthetic data, we investigate how model parameter uncertainty depends on model structure constraints using different norms of the likelihood function and the model constraints, and study the added benefits of joint inversion of EM and electrical resistivity tomography (ERT) data. Our results demonstrate that model structure constraints are necessary to stabilize the MCMC inversion results of a highly discretized model. These constraints decrease model parameter uncertainty and facilitate model interpretation. A drawback is that these constraints may lead to posterior distributions that do not fully include the true underlying model, because some of its features exhibit a low sensitivity to the EM data, and hence are difficult to resolve. This problem can be partly mitigated if the plane-wave EM data is augmented with ERT observations. The hierarchical Bayesian inverse formulation introduced and used herein is able to successfully recover the probabilistic properties of the measurement data errors and a model regularization weight. Application of the proposed inversion methodology to field data from an aquifer demonstrates that the posterior mean model realization is very similar to that derived from a deterministic inversion with similar model constraints.
Resumo:
Many therapies have been proposed for the management of temporomandibular disorders, including the use of different drugs. However, lack of knowledge about the mechanisms behind the pain associated with this pathology, and the fact that the studies carried out so far use highly disparate patient selection criteria, mean that results on the effectiveness of the different medications are inconclusive. This study makes a systematic review of the literature published on the use of tricyclic antidepressants for the treatment of temporomandibular disorders, using the SORT criteria (Strength of recommendation taxonomy) to consider the level of scientific evidence of the different studies. Following analysis of the articles, and in function of their scientific quality, a type B recommendation is given in favor of the use of tricyclic antidepressants for the treatment of temporomandibular disorders.
Resumo:
Modelling the shoulder's musculature is challenging given its mechanical and geometric complexity. The use of the ideal fibre model to represent a muscle's line of action cannot always faithfully represent the mechanical effect of each muscle, leading to considerable differences between model-estimated and in vivo measured muscle activity. While the musculo-tendon force coordination problem has been extensively analysed in terms of the cost function, only few works have investigated the existence and sensitivity of solutions to fibre topology. The goal of this paper is to present an analysis of the solution set using the concepts of torque-feasible space (TFS) and wrench-feasible space (WFS) from cable-driven robotics. A shoulder model is presented and a simple musculo-tendon force coordination problem is defined. The ideal fibre model for representing muscles is reviewed and the TFS and WFS are defined, leading to the necessary and sufficient conditions for the existence of a solution. The shoulder model's TFS is analysed to explain the lack of anterior deltoid (DLTa) activity. Based on the analysis, a modification of the model's muscle fibre geometry is proposed. The performance with and without the modification is assessed by solving the musculo-tendon force coordination problem for quasi-static abduction in the scapular plane. After the proposed modification, the DLTa reaches 20% of activation.
Resumo:
Being highly discussed the problem of climate change and global warming has been keeping importance for several of decades. As a response to the world’s need in solution for climate change disasters, the United Nations Framework Convention on Climate Change was adopted in 1992 and supplemented with the Kyoto protocol in 1997. This work is aimed to give better understanding of the Convention, Kyoto Protocol with its mechanisms and their function, related to energy projects in such case countries, as Russia and China, in order to assist evaluation of projects cost-effectiveness. It provides basic information about the Convention and the Protocol with their regulations, overview of present situation and future post-Kyoto forecasts, while the most attention is concentrated on the clean development mechanism and joint implementation step-by-step project cycles and specific regulations in given countries. The current study disclosed that CDM and JI project cycles are resulting in a complicated process. By the moment it requires step-by-step following of a number of methodologies, spending time and finance to particular project development. Uncertainties about post-Kyoto period bring additional risk to the projects and complicate any business decision concerning Kyoto Protocol.
Resumo:
Different therapeutic options for prosthetic joint infections exist, but surgery remains the key. With a two-stage exchange procedure, a success rate above 90% can be expected. Currently, there is no consensus regarding the optimal duration between explantation and the reimplantation in a two-stage procedure. The aim of this study was to retrospectively compare treatment outcomes between short-interval and long-interval two-stage exchanges. Patients having a two-stage exchange of a hip or knee prosthetic joint infection at Lausanne University Hospital (Switzerland) between 1999 and 2013 were included. The satisfaction of the patient, the function of the articulation and the eradication of infection, were compared between patients having a short (2 to 4 weeks) versus a long (4 weeks and more) interval during a two-stage procedure. Patient satisfaction was defined as good if the patient did not have pain and bad if the patient had pain. Functional outcome was defined good if the patient had a prosthesis in place and could walk, medium if the prosthesis was in place but the patient could not walk, and bad if the prosthesis was no longer in place. Infection outcome was considered good if there had been no re-infection and bad if there had been a re-infection of the prosthesis 145 patients (100 hips, 45 knees) were identified with a median age of 68 years (range 19-103). The median hospital stay was 58 days (range 10-402). The median follow-up was 12.9 months (range 0.5-152). 28 % and 72 % of the patients had a short-interval and long-interval exchange of the prosthesis, respectively. Patient satisfaction, functional outcome and infection outcome for patients having a short versus a long interval are reported in the Table. The patient satisfaction was higher when a long interval was performed whereas the functional and infection outcomes were higher when a short interval was performed. According to this study a short-interval exchange appears preferable to a long interval, especially in the view of treatment effectiveness and functional outcome.