995 resultados para indoor temperature
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings
Resumo:
This study aimed to develop a multi-component model that can be used to maximise indoor environmental quality inside mechanically ventilated office buildings, while minimising energy usage. The integrated model, which was developed and validated from fieldwork data, was employed to assess the potential improvement of indoor air quality and energy saving under different ventilation conditions in typical air-conditioned office buildings in the subtropical city of Brisbane, Australia. When operating the ventilation system under predicted optimal conditions of indoor environmental quality and energy conservation and using outdoor air filtration, average indoor particle number (PN) concentration decreased by as much as 77%, while indoor CO2 concentration and energy consumption were not significantly different compared to the normal summer time operating conditions. Benefits of operating the system with this algorithm were most pronounced during the Brisbane’s mild winter. In terms of indoor air quality, average indoor PN and CO2 concentrations decreased by 48% and 24%, respectively, while potential energy savings due to free cooling went as high as 108% of the normal winter time operating conditions. The application of such a model to the operation of ventilation systems can help to significantly improve indoor air quality and energy conservation in air-conditioned office buildings.
Resumo:
The control of environmental factors in open-office environments, such as lighting and temperature is becoming increasingly automated. This development means that office inhabitants are losing the ability to manually adjust environmental conditions according to their needs. In this paper we describe the design, use and evaluation of MiniOrb, a system that employs ambient and tangible interaction mechanisms to allow inhabitants of office environments to maintain awareness of environmental factors, report on their own subjectively perceived office comfort levels and see how these compare to group average preferences. The system is complemented by a mobile application, which enables users to see and set the same sensor values and preferences, but using a screen-based interface. We give an account of the system’s design and outline the results of an in-situ trial and user study. Our results show that devices that combine ambient and tangible interaction approaches are well suited to the task of recording indoor climate preferences and afford a rich set of possible interactions that can complement those enabled by more conventional screen-based interfaces.
Resumo:
We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.
Resumo:
Background: Endemic northern malaria reached 68°N latitude in Europe during the 19th century, where the summer mean temperature only irregularly exceeded 16°C, the lower limit needed for sporogony of Plasmodium vivax. Because of the available historical material and little use of quinine, Finland was suitable for an analysis of endemic malaria and temperature. Methods: Annual malaria death frequencies during 1800–1870 extracted from parish records were analysed against long-term temperature records in Finland, Russia and Sweden. Supporting data from 1750–1799 were used in the interpretation of the results. The life cycle and behaviour of the anopheline mosquitoes were interpreted according to the literature. Results: Malaria frequencies correlated strongly with the mean temperature of June and July of the preceding summer, corresponding to larval development of the vector. Hatching of imagoes peaks in the middle of August, when the temperature most years is too low for the sporogony of Plasmodium. After mating some of the females hibernate in human dwellings. If the female gets gametocytes from infective humans, the development of Plasmodium can only continue indoors, in heated buildings. Conclusion: Northern malaria existed in a cold climate by means of summer dormancy of hypnozoites in humans and indoor transmission of sporozoites throughout the winter by semiactive hibernating mosquitoes. Variable climatic conditions did not affect this relationship. The epidemics, however, were regulated by the population size of the mosquitoes which, in turn, ultimately was controlled by the temperatures of the preceding summer.
Resumo:
This study, though, has as its core objective cost reduction in aquaculture nutrition was equally designed to investigate the value of the peels of cassava (Manihot utillisima) as energy source in the diet of Oreochromis niloticus fry. Three levels of cassava peels diet and a control (100% yellow maize in the carbohydrate mixture) was prepared and tested on O. niloticus fry for ten (10) weeks. The fry with mean weight of 0.32g were grouped fifteen (15) in each of the glass aquaria measuring 60x30x30cm with a maximum capacity of 52 litres of water. The fry were fed twice daily at 10% biomass. Weekly, the fry were weighed to determine the weight increment or otherwise and the quality of feed adjusted accordingly. Water quality parameters like temperature, pH and dissolved oxygen (D.0) were monitored and found to be at desirable level. DT 3 (97 % cassava peels and 3% yellow maize) in the carbohydrate mixture gave the best growth performance. The fry fed, this diet gained mean weight of 1.18g for the period of the experiment. However, the poorest performance in terms of growth was from fry fed the control diet (100%yellow maize in the carbohydrate mixture) fry fed this diet gained mean weight of 0.80 for the duration of the experiment. Analysis of the various growth indices like SGR, PER, FCR and NPU shows that DT3 was the overall best diet with an SGR value of2.40 and FCR of 43.83. However, DT 1 (70% cassava peels and 30% yellow maize) gave the poorest SGR of 1.61 and FCR of 67.58. The difference in weight gain among the fry fed the three levels of cassava peels diet and the control was not statically significant (P>0.05)
Resumo:
As a large conspicuous intertidal brown alga, individuals of Sargassum horneri can reach a length of more than 7 m with a fresh weight of 3 kg along the coasts of the Eastern China Sea. The biomass of this alga as a vital component in coastal water ecology has been well documented. In recent years, a steady disappearance of the algal biomass along the once densely populated coastal areas of the Eastern China Sea has drawn attention in China. Efforts have been made to reconstruct the subtidal algal flora or even to grow the alga by use of long-lines. As part of the efforts to establish an efficient technique for producing seedlings of S. horneri, in this investigation a series of culture experiments were carried out in indoor raceway and rectangular tanks under reduced solar irradiance at ambient temperature in 2007-2008. The investigation demonstrated that: (1) sexual reproduction of S. horneri could be accelerated in elevated temperature and light climates, at least 3 months earlier than in the wild; (2) eggs of S. horneri had the potential to be fertilized up to 48 h, much longer than that of known related species; (3) suspension and fixed culture methods were both effective in growing the seedlings to the long-line cultivation stage; and (4) the life cycle of S. horneri in culture could be shortened to 4.5 months, thus establishing this alga as an appropriate model for investigating sexual reproduction in dieocious species of this genus.
Resumo:
Temperature, relative humidity, and air quality all affect the sensory system via thermo receptors in the skin and the olfactory system. Air quality is mainly defined by the contaminants in the air. However, the most persistent memory of any space is often its odor. Strong, emotional, and past experiences are awakened by the olfactory sense. Odors can also influence cognitive processes that affect creative task performance, as well as personal memories and moods. Besides nitrogen and oxygen, the air contains particles and many chemicals that affect the efficiency of the oxygenation process in the blood, and ultimately the air breathed affects thinking and concentration. It is important to show clients the value of spending more capital on high-quality buildings that promote good ventilation. The process of achieving indoor-air quality is a continual one throughout the design, construction, commissioning, and facilities management processes. This paper reviews the evidence.
Resumo:
Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS
Resumo:
Demand for good indoor air quality is increasing as people recorgnise the risks to their health and productivity from indoor pollutants. There is a tendency to reduce ventilation rates to ensure energy conservation in buildings; in this instance schools. However, evidence reviewed shows that this can be detrimental to health and wellbeing in schools because of the learner density within a small area (1.8 - 2.4m2/person); eventually indicating that carbon dioxide (CO2) levels can rise to very high levels in classroom occupancy periods. A preliminary study to investigate the impact of indoor environmental parameters has been performed in a secondary school classroom in Pretoria, South Africa. Factors monitored include temperature, relative humidity, lighting, air velocities and CO2 concentrations. From the results low air velocities are recorded (i.e. 0.1-0.3m/s) impacting on the retention of CO2 build-up in the classroom. Results presented in this paper are the initial findings of ongoing research.
Resumo:
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m(-3)]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16A degrees C and above 25A degrees C caused a reduction in the concentration (CFU m(-3)) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Air conditioning-induced rhinitis in allergic individuals is a common epidemiologic finding, but its physiopathology,is still controversial. The aim of this study was to describe and compare the effects of experimental air conditioning temperature changes on the nasal mucosa of individuals with persistent allergic rhinitis compared with a control group.Methods: A case-control challenge study was performed in a laboratory of thermal comfort with experimental twin challenge chambers set at a 12 C difference in temperature. A group of 32 patients with persistent allergic rhinitis and a group of 16 control subjects were exposed for 30 minutes, 3 times alternately in each chamber. Nasal symptom scores were recorded and nasal samples collected before, immediately after, and 24 and 48 hours after the challenge.Results: the rhinitis group showed a higher symptom score, epithelial shedding, percentage of eosinophils, total inflammatory cells, leukotriene C-4, eosinophil cationic protein, albumin, and tryptase levels compared with controls. There was also a significant increase in symptom score, total cells recovered, percentage of eosinophils, epithelial shedding, albumin, myeloperoxidase, and soluble intercellular adhesion molecule 1 in both groups compared with baseline levels.Conclusion: Sudden temperature changes led to a more pronounced inflammatory nasal response in the rhinitis group with the recruitment and activation of eosinophils.Clinical implications: Persistent allergic rhinitis is a risk factor for developing sudden temperature change-related rhinitis even in the absence of allergen exposure.
Resumo:
In the work underlying this thesis solid-phase microextraction (SPME) was evaluated as a passive sampling technique for organophosphate triesters in indoor air. These compounds are used on a large scale as flame-retarding and plastizicing additives in a variety of materials and products, and have proven to be common pollutants in indoor air. The main objective of this work was to develop an accurate method for measuring the volatile fraction. Such a method can be used in combination with active sampling to obtain information regarding the vapour/particulate distribution in different indoor environments. SPME was investigated under both equilibrium and non-equilibrium conditions and parameters associated with these different conditions were estimated. In Paper I, time-weighted average (TWA) SPME under dynamic conditions was investigated in order to obtain a fast air sampling method for organophosphate triesters. Among the investigated SPME coatings, the absorptive PDMS polymer had the highest affinity for the organophosphate triesters and was consequently used in all further work. Since the sampling rate is dependent on the agitation conditions, the linear airflow rates had to be carefully considered. Sampling periods as short as 1 hour were shown to be sufficient for measurements in the ng-μg m-3 range when using a PDMS 100-μm fibre and a linear flow rate above 7 cm s-1 over the fibre. SPME under equilibrium conditions is rather time-consuming, even under dynamic conditions, for slowly partitioning compounds such as organophosphate triesters. Nevertheless, this method has some significant advantages. For instance, the limit of detection is much lower compared to 1 h TWA sampling. Furthermore, the sampling time can be ignored as long as equilibrium has been attained. In Paper II, SPME under equilibrium conditions was investigated and evaluated for organophosphate triester vapours. Since temperature and humidity are closely associated with the distribution constant a simple study of the effect of these parameters was performed. The obtained distribution constants were used to determine the air levels in a common indoor environment. SPME and parallel active sampling on filters yielded similar results, indicating that the detected compounds were almost entirely associated with the vapour phase To apply dynamic SPME method in the field a sampler device, which enables controlled linear airflow rates to be applied, was constructed and evaluated (Paper III). This device was developed for application of SPME and active sampling in parallel. A GC/PICI-MS/MS method was developed and used in combination with active sampling of organophosphate triesters in indoor air (Paper IV). The combination of MS/MS and the soft ionization achieved with methanol as reagent gas yielded high selectivity and detection limits comparable to those provided by GC with nitrogen-phosphorus detection (NPD). The method limit of detection, when sampling 1.5 m3 of air, was in the range 0.1-1.4 ng m-3. In Paper V, the developed MS method was used in combination with SPME for indoor air measurements. The levels detected in the investigated indoor environments range from a few ng to μg m-3. Tris(2-chloropropyl) phosphate was detected at a concentration as high as 7 μg m-3 in a newly rebuilt lecture room.
Resumo:
Many preanalytical variables affect the results of coagulation assays. A possible way to control some of them would be to accept blood specimens shipped in the original collection tube. The aim of our study was to investigate the stability of coagulation assays in citrated whole blood transported at ambient temperature for up to two days after specimen collection. Blood samples from 59 patients who attended our haematology outpatient ward for thrombophilia screening were transported at ambient temperature (outdoor during the day, indoor overnight) for following periods of time: <1 hour, 4-6, 8-12, 24-28 and 48-52 hours prior to centrifugation and plasma-freezing. The following coagulation tests were performed: PT, aPTT, fibrinogen, FII:C, FV:C, FVII:C, FVIII:C, FIX:C, FX:C, FXI:C, VWF:RCo, VWF:Ag, AT, PC activity, total and free PS antigen, modified APC-sensitivity-ratio, thrombin-antithrombin-complex and D-dimer. Clinically significant changes, defined as a percentage change of more than 10% from the initial value, were observed for FV:C, FVIII:C and total PS antigen starting at 24-28 hours, and for PT, aPTT and FVII:C at 48-52 hours. No statistically significant differences were seen for fibrinogen, antithrombin, or thrombin-antithrombin complexes (Friedman repeated measures analysis of variance). The present data suggest that the use of whole blood samples transported at ambient temperature may be an acceptable means of delivering specimens for coagulation analysis. With the exception of factor V and VIII coagulant activity, and total PS antigen all investigated parameters can be measured 24-28 hours after specimen collection without observing clinically relevant changes.
Resumo:
Research studies on the association between exposures to air contaminants and disease frequently use worn dosimeters to measure the concentration of the contaminant of interest. But investigation of exposure determinants requires additional knowledge beyond concentration, i.e., knowledge about personal activity such as whether the exposure occurred in a building or outdoors. Current studies frequently depend upon manual activity logging to record location. This study's purpose was to evaluate the use of a worn data logger recording three environmental parameters—temperature, humidity, and light intensity—as well as time of day, to determine indoor or outdoor location, with an ultimate aim of eliminating the need to manually log location or at least providing a method to verify such logs. For this study, data collection was limited to a single geographical area (Houston, Texas metropolitan area) during a single season (winter) using a HOBO H8 four-channel data logger. Data for development of a Location Model were collected using the logger for deliberate sampling of programmed activities in outdoor, building, and vehicle locations at various times of day. The Model was developed by analyzing the distributions of environmental parameters by location and time to establish a prioritized set of cut points for assessing locations. The final Model consisted of four "processors" that varied these priorities and cut points. Data to evaluate the Model were collected by wearing the logger during "typical days" while maintaining a location log. The Model was tested by feeding the typical day data into each processor and generating assessed locations for each record. These assessed locations were then compared with true locations recorded in the manual log to determine accurate versus erroneous assessments. The utility of each processor was evaluated by calculating overall error rates across all times of day, and calculating individual error rates by time of day. Unfortunately, the error rates were large, such that there would be no benefit in using the Model. Another analysis in which assessed locations were classified as either indoor (including both building and vehicle) or outdoor yielded slightly lower error rates that still precluded any benefit of the Model's use.^