990 resultados para imaging method
Resumo:
The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
In recent years, management of abdominal pain in emergency care units (ECU) has undergone a radical change. Chronic work overload of ECU and increase in severity and complexity of cases required an optimal medical imaging method, such as ultrasound, to establish an accurate diagnosis as quickly as possible. A great variety of causes may cause acute abdominal pain and the role of sonography is to accurately distinguish between these aetiologies. For the application of sonography, perhaps more so than with other imaging methods, a perfect knowledge of sonographical characteristics and technical possibilities is essential to achieve an optimal answer. The purpose of this review is to present and discuss the sonographic characteristics of extra-digestive causes of acute abdominal pain such as splenic infarction, thoracic pathologies, urinary and gynaecologic diseases or retroperitoneal pathologies.
Resumo:
Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.
Resumo:
Retroperitoneal fibrosis (RF) is a rare disease, typically with an insidious clinical course. The peak incidence is seen in patients 40 to 60 years of age and mostly in man. The characteristic finding in this disease is a periaortic fibrous mass that often surrounds the ureters. Although usually regarded as an obstructive uropathy, there has been growing recognition of the condition as a generalized disease. It may have a wide variety of manifestations including mediastinitis, thyroiditis and sclerosing cholangitis. The most common mode of presentation remains abdominal or flank pain with uremia, anemia and a high sedimentation rate. Although ultrasound and renal scintigraphy may contribute to the general evaluation of patients with RF, CT-scanner is the preferred imaging method. The multiplanar imaging capability of magnetic resonance may facilitate assessment of disease extent. The pathogenesis of the disease remains unknown. Steroids and, more recently tamoxifen, appear to be effective in the treatment of the RF. In most instances, RF does not lead to long-term morbidity or affect survival. The three cases of RF reported herein illustrate the varied mode of presentation and the response to the treatment.
Resumo:
Following 15 years of experimental studies, tumor immunotargeting using monoclonal antibodies directed against tumor associated antigens shows now important monoclonal antibodies directed against tumor associated antigens shows now important clinical developments. This is mainly due to encouraging therapeutic results which have obtained using humanized antibodies such as the anti-CD20 rituximab in follicular B lymphomas and the anti-DrbB2 herceptin in breast carcinomas. Thanks to genetic engineering it is possible to graft variable or hypervariable regions from murine antibodies to human IgG, and even to obtain fully human antibodies by using either transgenic mice containing a large part of the human repertoire of human IgG, or selection of human antibody fragments expressed by phages. Radiolabeling of antibodies played a major role to demonstrate the tumor immunotargeting specificity and remains attractive for the diagnosis by immunoscintigraphy as well as for the treatment by radioimmunotherapy of some cancers. In this review, the current results and the prospects of diagnostic and therapeutic uses of anti-tumor antibodies and their fragments will be described. Concerning diagnosis, 123-iodine or 99m-technetium labeled Fab fragments allowed very demonstrative tumor images but this technique has a limited effect upon the therapeutic attitude. Immuno-PET (positron emission tomography) could enhance the sensitivity of this imaging method. Radio-immunoguided surgery and immunophotodetection are attractive techniques still under evaluation. Concerning therapy, 131-iodine labeled anti-CD20 antibodies gave spectacular results in non-Hodgkin's B lymphomas. In solid tumors which as less radiosensitive, radioimmunotherapy could concern small tumors and need the use of two-steps targeting and/or alpha emitters radioisotopes. Some other strategies will be described such as bispecific antibodies directed against tumors and immune effector cells, some antibody fragments expressed on T cells called T-bodies or some biological studies using intrabodies. Published data and works in progress demonstrate that immunotargeting of tumors will have a growing place in the treatments of cancer patients.
Resumo:
In imaging diagnosis, redundant nerve roots of the cauda equina are characterized by the presence of elongated, enlarged and tortuous nerve roots in close relationship with a high-grade lumbar spinal canal stenosis. This is not an independent entity, but it is believed to be a consequence of the chronic compression at the level of the lumbar canal stenosis and thus may be part of the natural history of lumbar spinal stenosis. The present paper is aimed at reviewing the histopathological, electrophysiological and imaging findings, particularly at magnetic resonance imaging, as well as the clinical meaning of this entity. As the current assessment of canal stenosis and root compression is preferably performed by means of magnetic resonance imaging, this is the imaging method by which the condition is identified. The recognition of redundant nerve roots at magnetic resonance imaging is important, particularly to avoid misdiagnosing other conditions such as intradural arteriovenous malformations. The literature approaching the clinical relevance of the presence of redundant nerve roots is controversial. There are articles suggesting that the pathological changes of the nerve roots are irreversible at the moment of diagnosis and therefore neurological symptoms are less likely to improve with surgical decompression, but such concept is not a consensus.
Resumo:
AbstractObjective:To establish benchmarks and study some sonographic characteristics of the thyroid gland in a group of euthyroid children aged up to 5 years as compared with age-matched children with congenital hypothyroidism.Materials and Methods:Thirty-six children (17 female and 19 male) aged between 2 months and 5 years were divided into two groups – 23 euthyroid children and 13 children with congenital hypothyroidism – and were called to undergo ultrasonography.Results:In the group of euthyroid children (n = 23), mean total volume of the thyroid gland was 1.12 mL (minimum, 0.39 mL; maximum, 2.72 mL); a homogeneous gland was found in 17 children (73.91%) and 6 children (26.08%) had a heterogeneous gland. In the group of children with congenital hypothyroidism (n = 13), mean total volume of the thyroid gland was 2.73 mL (minimum, 0.20 mL; maximum, 11.00 mL). As regards thyroid location, 3 patients (23.07%) had ectopic thyroid, and 10 (69.23%) had topic thyroid, and out of the latter, 5 had a homogeneous gland (50%) and 5, a heterogeneous gland (50%). In the group with congenital hypothyroidism, 6 (46.15%) children had etiological diagnosis of dyshormoniogenesis, 3 (23.07%), of ectopic thyroid, and 4 (30.76%), of thyroid hypoplasia.Conclusion:Thyroid ultrasonography is a noninvasive imaging method, widely available, easy to perform and for these reasons could, and should, be performed at any time, including at birth, with no preparation or treatment discontinuation, to aid in the early etiological definition of congenital hypothyroidism.
Resumo:
Työn tarkoituksena oli uutta kuvantamistekniikkaa hyödyntäen tutkia erilaisten tekijöiden vaikutusta kaasun dispergoitumiseen kemikaalisekoittimessa, kun kaasua sekoitetaan keskisakeaan massaan. Lisäksi työssä pyrittiin selvittämään, kuinka paljon kuitususpensioon tuotettu kaasufaasin kuplakokojakauma vaikuttaa happidelignifioinnin tulokseen. Kaasumaisten aineiden käyttäytymistä keskisakeissa kuitususpensiossa ei tarkkaan tunneta. Mikäli kaasumaisen hapen käyttäytymisestä saadaan uutta tietoa, tarjoaa tämä muun muassa uusia mahdollisuuksia kaasua sekoittavien laitteiden tuotekehityksessä. Työn kokeellinen osuus koostui kahdesta osasta, joista ensimmäisessä osassa selvitettiin sekoittimen roottorin pyörimisnopeuden, reaktorin kaasutilavuuden sekä suspension sakeuden vaikutusta muodostuvaan kaasun kuplakokojakaumaan. Työn jälkimmäisessä osassa arvioitiin yksivaiheisten keskisakeudessa tehtyjen happidelignifiointien perusteella suspensioon tuotetun kaasun kuplakokojakauman merkitystä happidelignifiointitulokseen. Kuplakokojakaumat määritettiin reaktoriin kiinnitetyllä kameralla kuvatuista valokuvista, joita otettiin sekoitustapahtuman aikana. Työn tuloksien perusteella sekoituksen voimakkuudella oli suurin vaikutus suspensioon muodostuvan kuplakokojakauman kannalta. Roottorin kierrosnopeuden kasvaessa kaasun keskimääräinen kuplakoko pieneni sekä havaittujen kuplien lukumäärää kasvoi huomattavasti. Myös suspension sakeuden kasvattamisen havaittiin vaikuttavan kuplakokoon pienentävästi. Happidelignifioinneissa saavutettiin paras kappareduktio, kun kaasun kuplakoko oli mahdollisimman pieni. Käytetty kuvantamistekniikka on tiettävästi ensimmäinen menetelmä, jolla saadaan reaaliaikaista tietoa vain muutamien kymmenien mikrometrien kokoisten kaasukuplien käyttäytymisestä oikeassa prosessitilanteessa.
Resumo:
The aim of the present study was the ultrasound characterization of the abdominal and pelvic regions of five maned wolves kept in captivity at the Triage Center of Wild Animals of the Federal University of Viçosa (Centro de Triagem de Animais Silvestres, Universidade Federal de Viçosa). This characterization included descriptions of ultrasonographic aspects and measurements of various structures using B-mode ultrasound. Biometric data were collected to assess the existence of significant linear correlations between these measurements and the measurements obtained by ultrasound. Additionally, hematological and serum biochemistry evaluations of the animals were performed. The ultrasound findings were similar to those available in the literature on domestic dogs, which were used for comparison as a result of the lack of published data regarding maned wolves. The latter species showed characteristics closely resembling those of the former, differing in the spleen and left renal cortex echogenicities, in the appearance of the prostatic and testicular regions and in the hepatic portal vein morphology. In the current study, the biometric values were similar to those previously published; however, no data regarding thoracic perimeter, modified crown-rump length or thoracic depth were found in the literature for this Canidae species. Statistical analysis showed the existence of a strong negative correlation between the modified crown-rump length and left renal length, between the modified crown-rump length and the right renal volume, between the thoracic perimeter and the height at the cranial pole of the left adrenal gland and between the thoracic perimeter and the height at the caudal pole of the left adrenal gland. Laboratory findings, including segmented neutrophil, eosinophil, monocyte and lymphocyte counts and the serum levels of glucose, ALT, alkaline phosphatase, urea, total protein, globulin, creatine phosphokinase, triglyceride, sodium, phosphate, potassium and chloride, were inconsistent with values found by other authors. The ultrasound is a diagnostic imaging method that must be further explored in the medicine of wild animals; therefore, additional research in this area is required.
Resumo:
Positron-emission tomography/computed tomography (PET/CT) has improved cyst infection (CI) management in autosomal dominant polycystic kidney disease (ADPKD). The determinants of kidney and/or liver involvement, however, remain uncertain. In this study, we evaluated clinical and imaging factors associated with CI in kidney (KCI) and liver (LCI) in ADPKD. A retrospective cohort study was performed in hospital-admitted ADPKD patients with suspected CI. Clinical, imaging and surgical data were analyzed. Features of infected cysts were evaluated by PET/CT. Total kidney (TKV) and liver (TLV) volumes were measured by CT-derived multiplanar reconstruction. CI was detected in 18 patients who experienced 24 episodes during an interval of 30 months (LCI in 12, KCI in 10 and concomitant infection in 2). Sensitivities of CT, magnetic resonance imaging and PET/CT were 25.0, 71.4, and 95.0%. Dysuria (P<0.05), positive urine culture (P<0.01), and previous hematuria (P<0.05) were associated with KCI. Weight loss (P<0.01) and increased C-reactive protein levels (P<0.05) were associated with LCI. PET/CT revealed that three or more infected cysts were present in 70% of the episodes. TKV was higher in kidney-affected than in LCI patients (AUC=0.91, P<0.05), with a cut-off of 2502 mL (72.7% sensitivity, 100.0% specificity). TLV was higher in liver-affected than in KCI patients (AUC=0.89, P<0.01) with a cut-off of 2815 mL (80.0% sensitivity, 87.5% specificity). A greater need for invasive procedures was observed in LCI (P<0.01), and the overall mortality was 20.8%. This study supports PET/CT as the most sensitive imaging method for diagnosis of cyst infection, confirms the multifocal nature of most hospital-admitted episodes, and reveals an association of kidney and liver volumes with this complication.
Resumo:
Intermediate filament keratins (K) play a pivotal role in protein targeting and epithelialcytoprotection from stress as evidenced by keratin mutations predisposing to human liver and skin diseases and possibly inflammatory bowel disease (IBD). The K8-null (K8-/-) mice exhibit colonic phenotype similar to IBD and marked spontaneous colitis, epithelial hyperproliferation, decreased apoptosis, mistargeting of proteins leading to defective ion transport and diarrhea. The K8-heterozygote (K8+/-) mouse colon appears normal but displays a defective sodium (Na+) and chloride (Cl-) transport similar to, but milder than K8-/-. Characterization of K8+/- colon revealed ~50% less keratins (K7, K8, K19, K20) compared to K8 wild type (K8+/+). A similar ~50% decrease was seen in K8+/- mRNA levels as compared to K8+/+, while the mRNA levels for the other keratins were unaltered. K8+/- keratins were arranged in a normal colonic crypt expression pattern, except K7 which was expressed at the top of crypts in contrast to K8+/+. The K8+/- colon showed mild hyperplasia but no signs of inflammation and no resistance to apoptosis. Experimental colitis induced by using different concentrations of dextran sulphate sodium (DSS) showed that K8+/- mice are slightly more sensitive to induced colitis and showed a delayed recovery compared to K8+/+. Hence, the K8+/- mouse with less keratins and without inflammation, provided a novel model to study direct molecular mechanisms of keratins in intestinal homeostasis and ion transport. Different candidate ion transporters for a possible role in altered ion transport seen in the K8-/- and K8+/- mouse colon were evaluated. Besides normal levels of CFTR, PAT-1 and NHE-3, DRA mRNA levels were decreased 3-4-fold and DRA protein nearly entirely lost in K8-/- caecum, distal and proximal colon compared to K8+/+. In K8+/- mice, DRA mRNA levels were unaltered while decreased DRA protein level and patchy distribution was detected particularly in the proximal colon and as compared to K8+/+. DRA was similarly decreased when K8 was knocked-down in Caco-2 cells, confirming that K8 levels modulate DRA levels in an inflammation-independent manner. The dramatic loss of DRA in colon and caecum of K8-/- mice was responsible for the chloride transport defect. The milder ion transport in K8+/- colon might be related to DRA suggesting a role for K8 in regulation of DRA expression and targeting. The current study demonstrates the importance of keratins in stress protection and cell signaling. Furthermore, we have also successfully developed a novel, simple, fast, cost effective, non-invasive in vivo imaging method for the early diagnosis of murine colitis with specificity for both genetic and experimental colitis. The said modality provides continuous measurements of reactive oxygen and nitrogen species (RONS) and minimizes the use of an increased number of experimental animals by using a luminal derivative chemiluminescent probe, L-012 which provides a cost-effective tool to study the level and longitudinal progression of colitis.
Resumo:
L’accident thromboembolique veineux, tel que la thrombose veineuse profonde (TVP) ou thrombophlébite des membres inférieurs, est une pathologie vasculaire caractérisée par la formation d’un caillot sanguin causant une obstruction partielle ou totale de la lumière sanguine. Les embolies pulmonaires sont une complication mortelle des TVP qui surviennent lorsque le caillot se détache, circule dans le sang et produit une obstruction de la ramification artérielle irriguant les poumons. La combinaison d’outils et de techniques d’imagerie cliniques tels que les règles de prédiction cliniques (signes et symptômes) et les tests sanguins (D-dimères) complémentés par un examen ultrasonographique veineux (test de compression, écho-Doppler), permet de diagnostiquer les premiers épisodes de TVP. Cependant, la performance de ces outils diagnostiques reste très faible pour la détection de TVP récurrentes. Afin de diriger le patient vers une thérapie optimale, la problématique n’est plus basée sur la détection de la thrombose mais plutôt sur l’évaluation de la maturité et de l’âge du thrombus, paramètres qui sont directement corrélées à ses propriétés mécaniques (e.g. élasticité, viscosité). L’élastographie dynamique (ED) a récemment été proposée comme une nouvelle modalité d’imagerie non-invasive capable de caractériser quantitativement les propriétés mécaniques de tissus. L’ED est basée sur l’analyse des paramètres acoustiques (i.e. vitesse, atténuation, pattern de distribution) d’ondes de cisaillement basses fréquences (10-7000 Hz) se propageant dans le milieu sondé. Ces ondes de cisaillement générées par vibration externe, ou par source interne à l’aide de la focalisation de faisceaux ultrasonores (force de radiation), sont mesurées par imagerie ultrasonore ultra-rapide ou par résonance magnétique. Une méthode basée sur l’ED adaptée à la caractérisation mécanique de thromboses veineuses permettrait de quantifier la sévérité de cette pathologie à des fins d’amélioration diagnostique. Cette thèse présente un ensemble de travaux reliés au développement et à la validation complète et rigoureuse d’une nouvelle technique d’imagerie non-invasive élastographique pour la mesure quantitative des propriétés mécaniques de thromboses veineuses. L’atteinte de cet objectif principal nécessite une première étape visant à améliorer les connaissances sur le comportement mécanique du caillot sanguin (sang coagulé) soumis à une sollicitation dynamique telle qu’en ED. Les modules de conservation (comportement élastique, G’) et de perte (comportement visqueux, G’’) en cisaillement de caillots sanguins porcins sont mesurés par ED lors de la cascade de coagulation (à 70 Hz), et après coagulation complète (entre 50 Hz et 160 Hz). Ces résultats constituent les toutes premières mesures du comportement dynamique de caillots sanguins dans une gamme fréquentielle aussi étendue. L’étape subséquente consiste à mettre en place un instrument innovant de référence (« gold standard »), appelé RheoSpectris, dédié à la mesure de la viscoélasticité hyper-fréquence (entre 10 Hz et 1000 Hz) des matériaux et biomatériaux. Cet outil est indispensable pour valider et calibrer toute nouvelle technique d’élastographie dynamique. Une étude comparative entre RheoSpectris et la rhéométrie classique est réalisée afin de valider des mesures faites sur différents matériaux (silicone, thermoplastique, biomatériaux, gel). L’excellente concordance entre les deux technologies permet de conclure que RheoSpectris est un instrument fiable pour la mesure mécanique à des fréquences difficilement accessibles par les outils actuels. Les bases théoriques d’une nouvelle modalité d’imagerie élastographique, nommée SWIRE (« shear wave induced resonance dynamic elastography »), sont présentées et validées sur des fantômes vasculaires. Cette approche permet de caractériser les propriétés mécaniques d’une inclusion confinée (e.g. caillot sanguin) à partir de sa résonance (amplification du déplacement) produite par la propagation d’ondes de cisaillement judicieusement orientées. SWIRE a également l’avantage d’amplifier l’amplitude de vibration à l’intérieur de l’hétérogénéité afin de faciliter sa détection et sa segmentation. Finalement, la méthode DVT-SWIRE (« Deep venous thrombosis – SWIRE ») est adaptée à la caractérisation de l’élasticité quantitative de thromboses veineuses pour une utilisation en clinique. Cette méthode exploite la première fréquence de résonance mesurée dans la thrombose lors de la propagation d’ondes de cisaillement planes (vibration d’une plaque externe) ou cylindriques (simulation de la force de radiation par génération supersonique). DVT-SWIRE est appliquée sur des fantômes simulant une TVP et les résultats sont comparés à ceux donnés par l’instrument de référence RheoSpectris. Cette méthode est également utilisée avec succès dans une étude ex vivo pour l’évaluation de l’élasticité de thromboses porcines explantées après avoir été induites in vivo par chirurgie.
Resumo:
Mammography is a diagnostic imaging method in which interpretation depends on knowledge of radiological aspects as well as the clinical exam and pathophysiology of breast diseases. In this work a mammography phantom was developed to be used for training in the operation of mammographic x-ray equipment, image quality evaluation, self-examination and clinical examination of palpation. Polyurethane was used for the production of the phantoms for its physical and chemical properties and because it is one of the components normally used in prostheses. According to the range of flexibility of the polyurethane, it was possible to simulate breasts with higher or lower amount of adipose tissue. Pathologies such as areolar necrosis and tissue rejection due to surgery reconstruction after partial mastectomy were also simulated. Calcifications and nodules were simulated using the following materials: polyethylene, poly (methyl methacrylate), polyamide, polyurethane and poly (dimethyl silicone). Among these, polyethylene was able to simulate characteristics of calcification as well as breast nodules. The results from mammographic techniques used in this paper for the evaluation of the phantoms are in agreement with data found in the literature. The image analyses of four phantoms indicated significant similarities with the human skin texture and the female breast parenchyma. It was possible to detect in the radiographic images produced regions of high and low radiographic optical density, which are characteristic of breasts with regions of different amount of adipose tissue. The stiffnesses of breast phantoms were adjusted according to the formulation of the polyurethane which enabled the production of phantoms with distinct radiographic features and texture similar to human female breast parenchyma. Clinical palpation exam of the phantoms developed in this work indicated characteristics similar to human breast in skin texture, areolar region and parenchyma
Resumo:
Scintimammography using Tc-99m-sestamibi is a noninvasive and painless diagnostic imaging method that is used to detect breast cancer when mammography is inconclusive Because of the advantages of labeling v '7,ith Tc-99m-sestamibi and its high efficiency in detecting carcinomas, it is the most widespread agent for this purpose Its accumulation in the tumor has multifactorial causes and does not depend on the presence of architectural distortion or local or diffuse density variation in the breast The objective of tfiis study was to evaluate the accuracy of scintimammography 1 for detecting breast cancer One hundred and fifty-seven patients presenting 158 palpable and non-palpable breast nodules were evaluated Three patients were male and 154 were female, aged between 14 and 81 years All patients underwent scintimammography, and the nodule was subjected i to cytological or histological study, i e, the gold standard for diagnosing cancer One hundred and eleven malignant and 47 benign nodules were detected, with predominance of ductal carcinomas (n=94) and fibroadenoma/fibrocysiic condition (n=11/n=11), respectively The mean size was 3 11 cm (7-10 cm) among the malignant nodules and 2 07 cm among the benign nodules (0 5-10 cm) The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 89, 89, 95, 78 and 89%, respectively Analysis on the histological types showed that the technique was more effective on tumors that were more aggressive, such as ductal carcinoma In this study, Tc-99m-sestamibi scintim immography was shown to be an important tool for diagnosing breast cancer when mammography was inconclusive
Resumo:
Descreveu-se a anatomia da região cervical de equinos adultos, com base em imagens obtidas no exame de tomografia computadorizada helicoidal realizado em peças anatômicas de equinos adultos. A tomografia computadorizada foi o método de imagem diagnóstica de escolha e possibilita as reconstruções de imagens tridimensionais e em outros planos anatômicos, como sagital e coronal. Todas as imagens foram adquiridas e avaliadas em filtro e janela para tecido ósseo. Observaram-se diferenças anatômicas e as particularidades normais das vértebras, principalmente da região occipitoatlantoaxial, a qual apresenta maior incidência de alterações.