106 resultados para homemade
Resumo:
Type-II SiGe/Si MQWs (Multi-Quantum Wells) and Self-Organized Ge/Si Islands were successfully grown by a homemade ultra-high vacuum/chemical vapor deposition (UHV/CVD) system. Growth characteristics and PL (photoluminescence) spectra at different temperature were measured. It demonstrated that some accumulation of carriers in the islands results in the increase of the integrated PL intensity of island-related at a certain temperature range.
Resumo:
Among various mutation detection methods, constant denaturant capillary electrophoresis (CDCE) is one of the most common techniques for rapid identification of known or unknown mutations. In this report, a CDCE analysis method with homemade linear polyacrylamide (LPA) kit was developed on ABI 310 genetic analyzer, the effect and relationship of various denaturing factors in CDCE analysis were investigated and K-ras gene mutations of 31 coloerctal cancer patients were detected. Results indicate that, with the increase of chemical danaturant concentration, the optimum temperature was lowered, and when the concentration of urea (formamide) was higher than 7 M (40%), the homoduplex and heteroduplex of mutant samples were separated with difficulty. Detection results of K-ras gene in colorectal samples indicated that mutations were present in eight (26%) of 31 patients; most mutations were localized in codon 12, which is thought to be a critical step and plays an important role in human colorectal carcinogenesisas. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Low-temperature heat capacities of the 9-fluorenemethanol (C14H12O) have been precisely measured with a small sample automatic adiabatic calorimeter over the temperature range between T = 78 K and T = 390 K. The solid-liquid phase transition of the compound has been observed to be T-fus = (376.567 +/- 0.012) K from the heat-capacity measurements. The molar enthalpy and entropy of the melting of the substance were determined to be Delta(fus)H(m) = (26.273 +/- 0.013) kJ (.) mol(-1) and Delta(fus)S(m) = (69.770 +/- 0.035) J (.) K-1 (.) mol(-1). The experimental values of molar heat capacities in solid and liquid regions have been fitted to two polynomial equations by the least squares method. The constant-volume energy and standard molar enthalpy of combustion of the compound have been determined, Delta(c)U(C14H12O, s) = -(7125.56 +/- 4.62) kJ (.) mol(-1) and Delta(c)H(m)degrees(C14H12O, s) = -(7131.76 +/- 4.62) kJ (.) mol(-1), by means of a homemade precision oxygen-bomb combustion calorimeter at T = (298.15 +/- 0.001) K. The standard molar enthalpy of formation of the compound has been derived, Delta(f)H(m)degrees (C14H12O, s) = -(92.36 +/- 0.97) kJ (.) mol(-1), from the standard molar enthalpy of combustion of the compound in combination with other auxiliary thermodynamic quantities through a Hess thermochemical cycle. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Accurate and fast genotyping of single nucleotide polymorphisms (SNPs) is important in the human genome project. Here an automated fluorescent method that can rapidly and accurately genotype multiplex known SNPs was developed by using a homemade kit, which has lower cost but higher resolution than commercial kit. With this method, oncogene K-ras was investigated, four known SNPs of K-ras gene exon 1 in 31 coloerctal cancer patients were detected. Results indicate that mutations were present in 8(26%) of 31 patients, and most mutations were localized in codon 12. The presence of these mutations is thought to be a critical step and plays an important role in human colorectal carcinogenesisas. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
A kind of simple atomic force microscopy (AFM) relocated technique, which takes advantage of homemade sample locator system, is used for investigating repeatedly imaging of some specific species on the whole substrate (over 1 x 1 cm(2)) with resolution about 400 nm. As applications of this sample locator system, single extended DNA molecules and plasmid DNA network are shown in different AFM operational modes: tapping mode and contact mode with different tips after the substrates have been moved.
Resumo:
A novel type of potassium sensor based on the capacitance change of valinomycin-incorporated bilayer supported on a gold electrode has been developed and characterized. The lipid membrane was Formed by painted method and monitored simultaneously by capacitance variation. The capacitance of the electrode-supported membrane was found to be modulated by different concentrations of K+. Investigating the capacitance change allows a simple and specific technique for the measurement of potassium ion in solution. Especially, the homemade capacitance meter is, to our knowledge, used to monitor the bilayer membrane formation and detect K+ for the first time. It has been proved that this capacitance measurement is a very useful technique because it is simple and sensitive compared to the other methods.
Resumo:
An ECSTM apparatus with an ideal tip using a homemade SSX-1A STM instrument has been constructed. STM and ECSTM tips were made by electrochemical etching and insulating with paraffin, silicon rubber or epoxy resin under an optical microscope. In situ imag
Resumo:
An HPLC-UV-MS method for simultaneous identification of predominant phenolics and minor nucleoside derivatives in Gastrodia elata was developed, which was based on their UV and MS characteristics summarized through a series of homemade reference standard experiments. Phenolics showed characteristic UV lambda(max) at 267 nm, [M + NH4](+) base peak in positive mode and [M - H](-) base peak in negative mode while nucleosides exhibited UV lambda(max) at 255 nm, [M + H](+), [M - H + 2H(2)O](-) or [M - H + CH3COOH](-). Phenolics conjugates mainly underwent the consecutive loss of gastrodin residue (- 268 U) and the combined loss of H2O and CO2 from the citric acid unit under negative MS/MS conditions whereas nucleosides simply lost the ribose (- 132 U) under positive MS/MS conditions. According to these characteristics, a special pattern under MS/MS conditions and reported compound data for G. elata in the literature, not only 15 phenolics were identified but also 6 nucleoside derivatives were identified. Among these compounds, seven phenolics and three nucleoside derivatives have not been reported yet from G. elata.
Resumo:
Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.
Resumo:
The emergence of electronic cigarettes (e-cigs) has given cannabis smokers a new method of inhaling cannabinoids. E-cigs differ from traditional marijuana cigarettes in several respects. First, it is assumed that vaporizing cannabinoids at lower temperatures is safer because it produces smaller amounts of toxic substances than the hot combustion of a marijuana cigarette. Recreational cannabis users can discretely "vape" deodorized cannabis extracts with minimal annoyance to the people around them and less chance of detection. There are nevertheless several drawbacks worth mentioning: although manufacturing commercial (or homemade) cannabinoid-enriched electronic liquids (e-liquids) requires lengthy, complex processing, some are readily on the Internet despite their lack of quality control, expiry date, and conditions of preservation and, above all, any toxicological and clinical assessment. Besides these safety problems, the regulatory situation surrounding e-liquids is often unclear. More simply ground cannabis flowering heads or concentrated, oily THC extracts (such as butane honey oil or BHO) can be vaped in specially designed, pen-sized marijuana vaporizers. Analysis of a commercial e-liquid rich in cannabidiol showed that it contained a smaller dose of active ingredient than advertised; testing our laboratory-made, purified BHO, however, confirmed that it could be vaped in an e-cig to deliver a psychoactive dose of THC. The health consequences specific to vaping these cannabis preparations remain largely unknown and speculative due to the absence of comprehensive, robust scientific studies. The most significant health concerns involve the vaping of cannabinoids by children and teenagers. E-cigs could provide an alternative gateway to cannabis use for young people. Furthermore, vaping cannabinoids could lead to environmental and passive contamination.
Resumo:
A homemade place card with an illustration of a pig with a wig and formal attire, holding a wine glass. The illustration is titled "The Host".
Resumo:
La spectroscopie Raman est un outil non destructif fort utile lors de la caractérisation de matériau. Cette technique consiste essentiellement à faire l’analyse de la diffusion inélastique de lumière par un matériau. Les performances d’un système de spectroscopie Raman proviennent en majeure partie de deux filtres ; l’un pour purifier la raie incidente (habituellement un laser) et l’autre pour atténuer la raie élastique du faisceau de signal. En spectroscopie Raman résonante (SRR), l’énergie (la longueur d’onde) d’excitation est accordée de façon à être voisine d’une transition électronique permise dans le matériau à l’étude. La section efficace d’un processus Raman peut alors être augmentée d’un facteur allant jusqu’à 106. La technologie actuelle est limitée au niveau des filtres accordables en longueur d’onde. La SRR est donc une technique complexe et pour l’instant fastidieuse à mettre en œuvre. Ce mémoire présente la conception et la construction d’un système de spectroscopie Raman accordable en longueur d’onde basé sur des filtres à réseaux de Bragg en volume. Ce système vise une utilisation dans le proche infrarouge afin d’étudier les résonances de nanotubes de carbone. Les étapes menant à la mise en fonction du système sont décrites. Elles couvrent les aspects de conceptualisation, de fabrication, de caractérisation ainsi que de l’optimisation du système. Ce projet fut réalisé en étroite collaboration avec une petite entreprise d’ici, Photon etc. De cette coopération sont nés les filtres accordables permettant avec facilité de changer la longueur d’onde d’excitation. Ces filtres ont été combinés à un laser titane : saphir accordable de 700 à 1100 nm, à un microscope «maison» ainsi qu’à un système de détection utilisant une caméra CCD et un spectromètre à réseau. Sont d’abord présentés les aspects théoriques entourant la SRR. Par la suite, les nanotubes de carbone (NTC) sont décrits et utilisés pour montrer la pertinence d’une telle technique. Ensuite, le principe de fonctionnement des filtres est décrit pour être suivi de l’article où sont parus les principaux résultats de ce travail. On y trouvera entre autres la caractérisation optique des filtres. Les limites de basses fréquences du système sont démontrées en effectuant des mesures sur un échantillon de soufre dont la raie à 27 cm-1 est clairement résolue. La simplicité d’accordabilité est quant à elle démontrée par l’utilisation d’un échantillon de NTC en poudre. En variant la longueur d’onde (l’énergie d’excitation), différentes chiralités sont observées et par le fait même, différentes raies sont présentes dans les spectres. Finalement, des précisions sur l’alignement, l’optimisation et l’opération du système sont décrites. La faible acceptance angulaire est l’inconvénient majeur de l’utilisation de ce type de filtre. Elle se répercute en problème d’atténuation ce qui est critique plus particulièrement pour le filtre coupe-bande. Des améliorations possibles face à cette limitation sont étudiées.
Resumo:
La radiothérapie stéréotaxique corporelle (SBRT) est une technique couramment employée pour le traitement de tumeurs aux poumons lorsque la chirurgie n’est pas possible ou refusée par le patient. Une complication de l’utilisation de cette méthode provient du mouvement de la tumeur causé par la respiration. Dans ce contexte, la radiothérapie asservie à la respiration (RGRT) peut être bénéfique. Toutefois, la RGRT augmente le temps de traitement en raison de la plus petite proportion de temps pour laquelle le faisceau est actif. En utilisant un faisceau de photons sans filtre égalisateur (FFF), ce problème peut être compensé par le débit de dose plus élevé d’un faisceau FFF. Ce mémoire traite de la faisabilité d’employer la technique de RGRT en combinaison avec l’utilisation un faisceau FFF sur un accélérateur Synergy S (Elekta, Stockholm, Suède) avec une ceinture pneumatique, le Bellows Belt (Philips, Amsterdam, Pays-Bas), comme dispositif de suivi du signal respiratoire. Un Synergy S a été modifié afin de pouvoir livrer un faisceau 6 MV FFF. Des mesures de profils de dose et de rendements en profondeur ont été acquises en cuve à eau pour différentes tailles de champs. Ces mesures ont été utilisées pour créer un modèle du faisceau 6 MV FFF dans le système de planification de traitement Pinnacle3 de Philips. Les mesures ont été comparées au modèle à l’aide de l’analyse gamma avec un critère de 2%, 2 mm. Par la suite, cinq plans SBRT avec thérapie en arc par modulation volumétrique (VMAT) ont été créés avec le modèle 6 MV du Synergy S, avec et sans filtre. Une comparaison des paramètres dosimétriques a été réalisée entre les plans avec et sans filtre pour évaluer la qualité des plans FFF. Les résultats révèlent qu’il est possible de créer des plans SBRT VMAT avec le faisceau 6 MV FFF du Synergy S qui sont cliniquement acceptables (les crières du Radiation Therapy Oncology Group 0618 sont respectés). Aussi, une interface physique de RGRT a été mise au point pour remplir deux fonctions : lire le signal numérique de la ceinture pneumatique Bellows Belt et envoyer une commande d’irradiation binaire au linac. L’activation/désactivation du faisceau du linac se fait par l’entremise d’un relais électromécanique. L’interface comprend un circuit électronique imprimé fait maison qui fonctionne en tandem avec un Raspberry Pi. Un logiciel de RGRT a été développé pour opérer sur le Raspberry Pi. Celui-ci affiche le signal numérique du Bellows Belt et donne l’option de choisir les limites supérieure et inférieure de la fenêtre d’irradiation, de sorte que lorsque le signal de la ceinture se trouve entre ces limites, le faisceau est actif, et inversement lorsque le signal est hors de ces limites. Le logiciel envoie donc une commande d’irradiation au linac de manière automatique en fonction de l’amplitude du signal respiratoire. Finalement, la comparaison entre la livraison d’un traitement standard sans RGRT avec filtre par rapport à un autre plan standard sans RGRT sans filtre démontre que le temps de traitement en mode FFF est réduit en moyenne de 54.1% pour un arc. De la même manière, la comparaison entre la livraison d’un traitement standard sans RGRT avec filtre par rapport à un plan de RGRT (fenêtre d’irradiation de 75%) sans filtre montre que le temps de traitement de RGRT en mode FFF est réduit en moyenne de 27.3% par arc. Toutefois, il n’a pas été possible de livrer des traitements de RGRT avec une fenêtre de moins de 75%. Le linac ne supporte pas une fréquence d’arrêts élevée.
Resumo:
Lo propuesto en este plan de negocio, es el diseño de un restaurante de comida oriental, recibiendo como nombre de POR TI: COME SALUDABLE, COME RICO, COME POR TI., ubicado en la ciudad de Bogotá D.C, específicamente en el barrio de chico de la localidad de Chapinero, dirigido al 1% de la población flotante y habitantes del sector entre estratos 4 a 6. POR TI nace bajo una propuesta que busca entregar al consumidor salud y cuidado personal. Brindando un producto de excelente calidad, preparado con ingredientes frescos, naturales y basados en recetas caseras, a través del concepto slow food y take away, arraigados en la cocina oriental, buscando crear colores, texturas y sabores que cautiven al consumidor. Se implementaran estrategias claras y concisas que permitan penetrar el mercado de la forma se ajuste a las necesidades del mismo. Se espera y aspira iniciar operaciones para Mayo del 2016, con un incremento de las ventas prometedor superando así el punto de equilibrio para el segundo año.
Resumo:
Optimization of photo-Fenton degradation of copper phthalocyanine blue was achieved by response surface methodology (RSM) constructed with the aid of a sequential injection analysis (SIA) system coupled to a homemade photo-reactor. Highest degradation percentage was obtained at the following conditions [H(2)O(2)]/[phthalocyanine] = 7, [H(2)O(2)]/[FeSO(4)] = 10, pH = 2.5, and stopped flow time in the photo reactor = 30 s. The SIA system was designed to prepare a monosegment containing the reagents and sample, to pump it toward the photo-reactor for the specified time and send the products to a flow-through spectrophotometer for monitoring the color reduction of the dye. Changes in parameters such as reagent molar ratios. residence time and pH were made by modifications in the software commanding the SI system, without the need for physical reconfiguration of reagents around the selection valve. The proposed procedure and system fed the statistical program with degradation data for fast construction of response surface plots. After optimization, 97% of the dye was degraded. (C) 2009 Elsevier B.V. All rights reserved.