949 resultados para heat demand
Resumo:
Various pellet heating systems are marketed in Sweden, some of them in combination with a solar heating system. Several types of pellet heating units are available and can be used for a combined system. This article compares four typical combined solar and pellet heating systems: System 1 and 2 two with a pellet stove, system 3 with a store integrated pellet burner and system 4 with a pellet boiler. The lower efficiency of pellet heaters compared to oil or gas heaters increases the primary energy demand. Consequently heat losses of the various systems have been studied. The systems have been modeled in TRNSYS and simulated with parameters identified from measurements. For almost all systems the flue gas losses are the main heat losses except for system 3 where store heat losses prevail. Relevant are also the heat losses of the burner and the boiler to the ambient. Significant leakage losses are noticed for system 3 and 4. For buildings with an open internal design system 1 is the most efficient solution. Other buildings should preferably apply system 3. The right choice of the system depends also on whether the heater is placed inside or outside of the heated are. A large potential for system optimization exist for all studied systems, which when applied could alter the relative merits of the different system types.
Resumo:
This master thesis presents a new technological combination of two environmentally friendly sources of energy in order to provide DHW, and space heating. Solar energy is used for space heating, and DHW production using PV modules which supply direct current directly to electrical heating elements inside a water storage tank. On the other hand a GSHP system as another source of renewable energy provides heat in the water storage tank of the system in order to provide DHW and space heating. These two sources of renewable energy have been combined in this case-study in order to obtain a more efficient system, which will reduce the amount of electricity consumed by the GSHP system.The key aim of this study is to make simulations, and calculations of the amount ofelectrical energy that can be expected to be produced by a certain amount of PV modules that are already assembled on a house in Vantaa, southern Finland. This energy is then intended to be used as a complement to produce hot water in the heating system of the house beside the original GSHP system. Thus the amount of electrical energy purchased from the grid should be reduced and the compressor in the GSHP would need fewer starts which would reduce the heating cost of the GSHP system for space heating and providing hot water.The produced energy by the PV arrays in three different circuits will be charged directly to three electrical heating elements in the water storage tank of the existing system to satisfy the demand of the heating elements. The excess energy can be used to heat the water in the water storage tank to some extent which leads to a reduction of electricity consumption by the different components of the GSHP system.To increase the efficiency of the existing hybrid system, optimization of different PV configurations have been accomplished, and the results are compared. Optimization of the arrays in southern and western walls shows a DC power increase of 298 kWh/year compared with the existing PV configurations. Comparing the results from the optimization of the arrays on the western roof if the intention is to feed AC power to the components of the GSHP system shows a yearly AC power production of 1,646 kWh.This is with the consideration of no overproduction by the PV modules during the summer months. This means the optimized PV systems will be able to cover a larger part of summer demand compared with the existing system.
Resumo:
This paper focuses on the study of cascade heat pump systems in combination with solar thermal for the production of hot water and space heating in single family houses with relatively high heating demand. The system concept was developed by Ratiotherm GmbH and simulated with TRNSYS 17. The basic cascade system uses the heat pump and solar collectors in parallel operation while a further development is the inclusion of an intermediate store that enables the possibility of serial/parallel operation and the use of low temperature solar heat. Parametric studies in terms of compressor size, refrigerant pair and size of intermediate heat exchanger were carried out for the optimization of the basic system. The system configurations were simulated for the complete year and compared to a reference of a solar thermal system combined with an air source heat pump. The results show ~13% savings in electricity use for all three cascade systems compared to the reference. However, the complexity of the systems is different and thus higher capital costs are expected.
Resumo:
Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.
Resumo:
A comparison of the thermal regime and oxygen distribution patterns of some Brazilian reservoirs was made. A strong latitudinal dependence of surface temperature, annual mean and annual range was found. Except for Tucurui Reservoir, a reservoir of the Equatorial zone, the lowest surface temperature of the year in the other compared reservoirs was observed from June to August while the highest extended from October to February. The decreasing trend of annual mean temperatures and thermal ranges was due to the increasing seasonal variability of insolation with the latitude. A positive relationship between the increase on thermal surface-bottom differences and the depth of water column was found for reservoirs of similar latitudes. A long thermal stratification (around four months) was evidenced in the lacustrine zone of reservoirs with a residence time higher than 40 days. Low fluctuation (<2%) of the annual variability of heat contents was observed for the Tucurui Reservoir, while in das Garcas Reservoir a manmade lake located in the frontier between tropical and temperate regions, the annual coefficient of variation attained 13%. Concerning the heat budgets, the value for the Tucurui Reservoir was two times higher than in das Garcas Reservoir. Both the morphometric and climatological factors affected the heat contents of the two compared reservoirs. In deep eutrophic reservoirs, a significant reduction on the oxygen concentrations in the hypolimnetic zone was frequently observed. In some oligotrophic stratified reservoirs, a decrease on oxygen with depth occurred when the temperature of the hypolimnion was higher than 20 degrees C and caused a biochemical oxygen demand. In das Garcas Reservoir, the actual oxygen deficits ranged from 0.40 to 1.52 mg.O-2.cm(-2) and appear to be linked to oxygen consumption after the senescence of Microcystis aeruginosa populations in the spring. But, other factors such as the allochthonous loads of organic matter also had an important role on the oxygen balance of das Garcas Reservoir.
Resumo:
Thermorheological changes in high hydrostatic pressure (HHP)-treated chickpea flour (CF) slurries were studied as a function of pressure level (0.1, 150, 300, 400, and 600 MPa) and slurry concentration (1:5, 1:4, 1:3, and 1:2 flour-to-water ratios). HHP-treated slurries were subsequently analyzed for changes in properties produced by heating, under both isothermal and non-isothermal processes. Elasticity (G′) of pressurized slurry increased with pressure applied and concentration. Conversely, heat-induced CF paste gradually transformed from solid-like behavior to liquid-like behavior as a function of moisture content and pressure level. The G′ and enthalpy of the CF paste decreased with increasing pressure level in proportion with the extent of HHP-induced starch gelatinization. At 25 °C and 15 min, HHP treatment at 450 and 600 MPa was sufficient to complete gelatinization of CF slurry at the lowest concentration (1:5), while more concentrated slurries would require higher pressures and temperature during treatment or longer holding times. Industrial relevance Demand for chickpea gel has increased considerably in the health and food industries because of its many beneficial effects. However, its use is affected by its very difficult handling. Judicious application of high hydrostatic pressure (HHP) at appropriate levels, adopted as a pre-processing instrument in combination with heating processes, is presented as an innovative technology to produce a remarkable decrease in thermo-hardening of heat-induced chickpea flour paste, permitting the development of new chickpea-based products with desirable handling properties and sensory attributes.
Resumo:
Present research is framed within the project MODIFICA (MODelo predictivo - edIFIcios - Isla de Calor urbanA) aimed at developing a predictive model for dwelling energy performance under the urban heat island effect in order to implement it in the evaluation of real energy demand and consumption of dwellings as well as in the selection of energy retrofitting strategies. It is funded by Programa de I+D+i orientada a los retos de la sociedad 'Retos Investigación' 2013. Despite great advances on building energy performance have been achieved during the last years, available climate data is derived from weather stations placed in the outskirts of the city. Hence, urban heat island effect is not considered in energy simulations, which implies an important lack of accuracy. Since 1980's several international studies have been conducted on the urban heat island (UHI) phenomena, which modifies the atmospheric conditions of the urban centres due to urban agglomeration [1][2][3][4]. In the particular case of Madrid, multiple maps haven been generated using different methodologies during the last two decades [5][6][7]. These maps allow us to study the UHI phenomena from a wide perspective, offering however an static representation of it. Consequently a dynamic model for Madrid UHI is proposed, in order to evaluate it in a continuous way, and to be able to integrate it in building energy simulations.
Resumo:
Present research is framed within the project MODIFICA (MODelo predictivo - edIFIcios - Isla de Calor Urbana) aimed at developing a predictive model for dwelling energy performance under the urban heat island effect in order to implement it in the evaluation of real energy demand and consumption of dwellings as well as in the selection of energy retrofitting strategies. It is funded by Programa de I+D+i orientada a los retos de la sociedad 'Retos Investigación' 2013. The scope of our predictive model is defined by the heat island effect (UHI) of urban structures that compose the city of Madrid. In particular, we focus on the homogeneous areas for urban structures with the same urban and building characteristics. Data sources for the definition of such homogeneous areas were provided by previous research on the UHI of Madrid. The objective is to establish a critical analysis of climate records used for energy simulation tools, which data come from weather stations placed in decontextualized areas from the usual urban reality, where the thermal conditions differs by up to 6ºC. In this way, we intend to develop a new predictive model for the consumption and demand in buildings depending on their location, the urban structure and the associated UHI, improving the future energy rehabilitation interventions
Resumo:
Esta investigación se enmarca dentro del proyecto MODIFICA (modelo predictivo - Edificios - Isla de Calor Urbano), financiado por el Programa de I + D + i Orientada a los Retos de la sociedad 'Retos Investigación' de 2013. Está dirigido a desarrollar un modelo predictivo de eficiencia energética para viviendas, bajo el efecto de isla de calor urbano (AUS) con el fin de ponerla en práctica en la evaluación de la demanda de energía real y el consumo en las viviendas. A pesar de los grandes avances que se han logrado durante los últimos años en el rendimiento energético de edificios, los archivos de tiempo utilizados en la construcción de simulaciones de energía se derivan generalmente de estaciones meteorológicas situadas en las afueras de la ciudad. Por lo tanto, el efecto de la Isla de Calor Urbano (ICU) no se considera en estos cálculos, lo que implica una importante falta de precisión. Centrado en explorar cómo incluir los fenómenos ICU, el presente trabajo recopila y analiza la dinámica por hora de la temperatura en diferentes lugares dentro de la ciudad de Madrid. Abstract This research is framed within the project MODIFICA (Predictive model - Buildings - Urban Heat Island), funded by Programa de I+D+i orientada a los retos de la sociedad 'Retos Investigación' 2013. It is aimed at developing a predictive model for dwelling energy performance under the Urban Heat Island (UHI) effect in order to implement it in the evaluation of real energy demand and consumption in dwellings. Despite great advances on building energy performance have been achieved during the last years, weather files used in building energy simulations are usually derived from weather stations placed in the outskirts of the city. Hence, Urban Heat Island (UHI) effect is not considered in this calculations, which implies an important lack of accuracy. Focused on exploring how to include the UHI phenomena, the present paper compiles and analyses the hourly dynamics of temperature in different locations within the city of Madrid.
Resumo:
A conceptual energy storage system design that utilizes ultra high temperature phase change materials is presented. In this system, the energy is stored in the form of latent heat and converted to electricity upon demand by TPV (thermophotovoltaic) cells. Silicon is considered in this study as PCM (phase change material) due to its extremely high latent heat (1800 J/g or 500 Wh/kg), melting point (1410 C), thermal conductivity (~25 W/mK), low cost (less than $2/kg or $4/kWh) and abundance on earth. The proposed system enables an enormous thermal energy storage density of ~1 MWh/m3, which is 10e20 times higher than that of lead-acid batteries, 2e6 times than that of Li-ion batteries and 5e10 times than that of the current state of the art LHTES systems utilized in CSP (concentrated solar power) applications. The discharge efficiency of the system is ultimately determined by the TPV converter, which theoretically can exceed 50%. However, realistic discharge efficiencies utilizing single junction TPV cells are in the range of 20e45%, depending on the semiconductor bandgap and quality, and the photon recycling efficiency. This concept has the potential to achieve output electric energy densities in the range of 200-450 kWhe/m3, which is comparable to the best performing state of the art Lithium-ion batteries.
Resumo:
The optimal integration between heat and work may significantly reduce the energy demand and consequently the process cost. This paper introduces a new mathematical model for the simultaneous synthesis of heat exchanger networks (HENs) in which the pressure levels of the process streams can be adjusted to enhance the heat integration. A superstructure is proposed for the HEN design with pressure recovery, developed via generalized disjunctive programming (GDP) and mixed-integer nonlinear programming (MINLP) formulation. The process conditions (stream temperature and pressure) must be optimized. Furthermore, the approach allows for coupling of the turbines and compressors and selection of the turbines and valves to minimize the total annualized cost, which consists of the operational and capital expenses. The model is tested for its applicability in three case studies, including a cryogenic application. The results indicate that the energy integration reduces the quantity of utilities required, thus decreasing the overall cost.
Resumo:
The optimal integration of work and its interaction with heat can represent large energy savings in industrial plants. This paper introduces a new optimization model for the simultaneous synthesis of work exchange networks (WENs), with heat integration for the optimal pressure recovery of process gaseous streams. The proposed approach for the WEN synthesis is analogous to the well-known problem of synthesis of heat exchanger networks (HENs). Thus, there is work exchange between high-pressure (HP) and low-pressure (LP) streams, achieved by pressure manipulation equipment running on common axes. The model allows the use of several units of single-shaft-turbine-compressor (SSTC), as well as stand-alone compressors, turbines and valves. Helper motors and generators are used to respond to any demand and excess of energy. Moreover, between the WEN stages the streams are sent to the HEN to promote thermal recovery, aiming to enhance the work integration. A multi-stage superstructure is proposed to represent the process. The WEN superstructure is optimized in a mixed-integer nonlinear programming (MINLP) formulation and solved with the GAMS software, with the goal of minimizing the total annualized cost. Three examples are conducted to verify the accuracy of the proposed method. In all case studies, the heat integration between WEN stages is essential to improve the pressure recovery, and to reduce the total costs involved in the process.
Resumo:
The representation of the thermal behaviour of the building is achieved through a relatively simple dynamic model that takes into account the effects due to the thermal mass of the building components. The model of a intra-floor apartment has been built in the Matlab-Simulink environment and considers the heat transmission through the external envelope, wall and windows, the internal thermal masses, (i.e. furniture, internal wall and floor slabs) and the sun gain due to opaque and see-through surfaces of the external envelope. The simulations results for the entire year have been compared and the model validated, with the one obtained with the dynamic building simulation software Energyplus.
Resumo:
Increasing interests in the use of starch as biodegradable plastic materials demand, amongst others, accurate information on thermal properties of starch systems particularly in the processing of thermoplastic starch (TPS), where plasticisers (water and glycerol) are added. The specific heat capacity of starch-water-glycerol mixtures was determined within a temperature range of 40-120degreesC. A modulated temperature differential scanning calorimeter (MTDSC) was employed and regression equations were obtained to predict the specific heat capacity as a function of temperature, water and glycerol content for four maize starches of differing amylose content (0 - 85%). Generally, temperature and water content are directly proportional to the specific heat capacity of the systems, but the influence of glycerol content on the thermal property varied according to the starch type.
Resumo:
In the present work, the more important parameters of the heat pump system and of solar assisted heat pump systems were analysed in a quantitative way. Ideal and real Rankine cycles applied to the heat pump, with and without subcooling and superheating were studied using practical recommended values for their thermodynamics parameters. Comparative characteristics of refrigerants here analysed looking for their applicability in heat pumps for domestic heating and their effect in the performance of the system. Curves for the variation of the coefficient of performance as a function of condensing and evaporating temperatures were prepared for R12. Air, water and earth as low-grade heat sources and basic heat pump design factors for integrated heat pumps and thermal stores and for solar assisted heat pump-series, parallel and dual-systems were studied. The analysis of the relative performance of these systems demonstrated that the dual system presents advantages in domestic applications. An account of energy requirements for space and hater heating in the domestic sector in the O.K. is presented. The expected primary energy savings by using heat pumps to provide for the heating demand of the domestic sector was found to be of the order of 7%. The availability of solar energy in the U.K. climatic conditions and the characteristics of the solar radiation here studied. Tables and graphical representations in order to calculate the incident solar radiation over a tilted roof were prepared and are given in this study in section IV. In order to analyse and calculate the heating load for the system, new mathematical and graphical relations were developed in section V. A domestic space and water heating system is described and studied. It comprises three main components: a solar radiation absorber, the normal roof of a house, a split heat pump and a thermal store. A mathematical study of the heat exchange characteristics in the roof structure was done. This permits to evaluate the energy collected by the roof acting as a radiation absorber and its efficiency. An indication of the relative contributions from the three low-grade sources: ambient air, solar boost and heat loss from the house to the roof space during operation is given in section VI, together with the average seasonal performance and the energy saving for a prototype system tested at the University of Aston. The seasonal performance as found to be 2.6 and the energy savings by using the system studied 61%. A new store configuration to reduce wasted heat losses is also discussed in section VI.