334 resultados para gotas
Resumo:
It was aimed to evaluate the spectrum and uniformity of droplets in function of sprayers, spraying volumes and rates of chemical insecticide on the mortality of Pseudoplusia includens in laboratory. The work was carried out at UNESP, Jaboticabal, SP, Brazil. The following treatments were applied over the caterpillars: two equipments (atomizer and hydraulic nozzle); two spray volumes (17 and 50 L ha(-1) for the atomizer and 50 and 100 L ha(-1) for the hydraulic nozzle); and two dosages of the insecticide endosulfan (0.5 and 1.0 L pc ha(-1)), in fully randomized plots, in a factorial scheme 2x2x2 and 1 untreated check. The caterpillars mortality was evaluated until the 6(th) day after the application of treatments. The spectrum of the droplets was evaluated in a particle size analyzer in real time determining the diameter and spectrum of droplets sprayed through the laser beam of the analyser. It was verified that the spray volume can be reduced by 17 L ha(-1) without losses on the P. includens control. The doses of 0.5 L pc ha(-1) (recommended for Anticarsia gemmatalis) did not satisfactorily control the caterpillar soybean looper. The atomizer produces droplets of higher uniformity (SPAN: 0.52) and lower percentage of droplets susceptible to drift (3.3%) compared to hydraulic nozzle (SPAN: 1.34 e % droplets <= 100 mu m: 15.2).
Resumo:
A escolha e o uso adequado de pontas de pulverização são essenciais para a correta aplicação de produtos fitossanitários, sendo, portanto, indispensável o conhecimento de suas características. Este trabalho teve o objetivo de caracterizar o perfil de distribuição e o diâmetro de gotas, oferecendo dados para otimizar o espaçamento entre bicos na barra de pulverização. Foram avaliados os perfis de distribuição da ponta de jato plano Teejet XR 110015 VS, a 0,50 m da altura da mesa de deposição, nas pressões de 200 e 300 kPa, e o diâmetro das gotas pelo método de difração de raios laser. As distâncias máximas foram de 0,85 m, calculadas para um coeficiente de variação (C.V.) aceitável para as pressões de 200 e 300 kPa , com os respectivos valores de 9,52 e 9,58%. A distância ótima foi de aproximadamente 0,70 m, para C.V. em torno de 5%. Comparando as pressões, houve diferença significativa para DV0,1 e DV0,5, não havendo diferença para o DV0,9. Embora o aumento da pressão tenha provocado diminuição do tamanho das gotas, não houve diferença significativa de uniformidade entre as duas pressões de trabalho avaliadas. Concluiu-se que o espaçamento máximo entre bicos na barra não deverá ser maior que 0,85 m e que o DV0,5 diminui com o aumento da pressão de 200 para 300 kPa, porém sem alteração significativa da uniformidade de diâmetro de gota.
Resumo:
O objetivo deste trabalho foi avaliar a deposição das gotas de pulverização, dotadas de carga elétrica (eletrostática), em comparação à técnica de pulverização convencional em crisântemo, com uso de diferentes pontas de pulverização. O experimento foi conduzido em delineamento inteiramente ao acaso, com oito tratamentos: combinação das pontas TXVK-3, AXI 110015, AXI 12002 TWIN e AXI 11003, com duas técnicas de pulverização (com e sem eletrostática), e quatro repetições. Cada repetição foi representada por 12 plantas, às quais foram afixados papéis do tipo mata-borrão na superfície abaxial e adaxial dos folíolos, e em duas posições da planta: ápice e base. Um corante marcador (Rodamina B) foi pulverizado na proporção de 5 g por 100 L d'água em cada um dos tratamentos. Os depósitos do marcador foram quantificados por fluorometria. As pontas com gotas de menor diâmetro mediano volumétrico (TXVK-3 e AXI 110015) apresentaram maiores depósitos na superfície abaxial da folha, quando se utilizou a pulverização eletrostática. Esse fato não foi observado, quando foram pulverizadas gotas com maior diâmetro mediano volumétrico e desprovidas de carga elétrica, nas diferentes partes da planta.
Resumo:
A diversidade morfológica da superfície foliar existente entre as espécies de plantas e a presença de estruturas foliares, como tricomas, estômatos, cutícula e ceras, podem exercer grande influência na aderência e deposição das gotas de pulverização, assim como na absorção do herbicida. Dessa forma, o objetivo do presente trabalho foi estudar, em plantas daninhas aquáticas emersas (Brachiaria mutica, Brachiaria subquadripara e Panicum repens), o pH foliar, bem como a área de molhamento de gotas de pulverização na superfície foliar adaxial e abaxial. O experimento foi conduzido no Núcleo de Pesquisas Avançadas em Matologia - NUPAM, pertencente à Faculdade de Ciências Agronômicas de Botucatu/SP - UNESP. As plantas foram cultivadas em caixas d'água no campo, quando elas atingiram seu pleno desenvolvimento (antes do florescimento), foram feitas as avaliações de pH foliar e da área de molhamento de gotas de pulverização. As tensões superficiais das gotas depositadas (0,5 µL), apresentadas pelas soluções de glyphosate aplicado isoladamente (5,0% v v-1, Rodeo 480g L-1 e.a. - produto comercial), glyphosate + Aterbane BR (5,0% + 0,5% v v-1), glyphosate + Silwet L-77 (5,0% + 0,05% v v-1), além das soluções com os adjuvantes isolados, Aterbane BR (0,5% v v-1) e Silwet L-77 (0,05% v v-1), foram respectivamente de 72,1; 28,7; 23,3; 37,3; e 22,1 mN m-1. As médias obtidas de pH foliar variaram entre 5,71 e 6,03, destacando-se a espécie B. mutica, com valores de 5,72 e 6,03 para as faces adaxial e abaxial, respectivamente. Contudo, mais estudos devem ser realizados para verificar a influência do pH foliar na absorção de herbicidas por espécies daninhas aquáticas. Das plantas daninhas aquáticas avaliadas, B. subquadripara foi a espécie que obteve as maiores médias de área de molhamento nas faces adaxial e abaxial da folha, proporcionadas pelas soluções de glyphosate + Aterbane BR, glyphosate + Silwet L-77 e Silwet L-77, com valores de 6,44 - 4,36; 7,77 - 10,59; e 10,94 - 10,28 mm², respectivamente.
Resumo:
Objetivou-se neste trabalho avaliar a uniformidade da deposição de gotas de pulverização em plantas de amendoim e de Brachiaria plantaginea localizadas nas linhas e entrelinhas de semeadura da cultura. O experimento de campo foi realizado com a cultura de amendoim, cultivar IAC Tatu-ST. As pulverizações foram feitas com a cultura nos estádios vegetativo (V1) e reprodutivo (R2). Foi utilizado, como marcador das gotas depositadas, o corante Azul Brilhante (FD&C-1) na concentração de 500 ppm. Os tratamentos foram constituídos por sete pontas de pulverização: XR 110015 VS (150 L ha-1), XR 11002 VS (200 L ha-1), TX-VK 6 (150 L ha-1), TX-VK 8 (200 L ha-1), AI 110015 VS (150 L ha-1), AI11002 VS (200 L ha-1) e TJ60 11002 VS (150 e 200 L ha-1). Utilizou-se o delineamento experimental em blocos ao acaso, com quatro repetições. Para as análises qualitativas, os dados obtidos foram ajustados à curva de regressão pelo modelo de Gompertz. As pontas XR 11002 VS (200 L ha-1) e TX-VK 6 (150 L ha-1) proporcionaram as maiores uniformidades de distribuição da pulverização nas plantas de amendoim cultivar IAC Tatu ST nos estádios vegetativo (V1) e reprodutivo (R2), respectivamente. A uniformidade de deposição nas plantas de B. plantaginea teve grande variação nos depósitos unitários sobre as plantas localizadas na linha e entrelinha da cultura. Apenas a ponta XR 11002 VS (200 L ha¹) causa falhas de deposição em ambos os estádios de desenvolvimento da B. plantaginea localizada na linha da cultura. Quanto às plantas localizadas na entrelinha, a maior eficiência das pontas de pulverização ocorre no estádio de 3-5 perfilhos.
Resumo:
The objective of this study was to evaluate the amount of spray deposition on peanut plants (Aracahis hypogaea) and on the weed Brachiaria plantaginea, in the rows and inter rows of the culture, as well as the amount of deposition on the soil. The study was conducted in the field using the peanut cultivar IAC Tatu-ST and the treatment applications were performed at the vegetative (V1) and reproductive (R2) stages. Brilliant Blue (FD&C-1) was used as tracer in water solution, at 500 ppm. The treatments were constituted of seven spray nozzles: XR 110015 VS (150 L ha(-1)), XR 11002 VS (200 L ha(-1)), TX-VK 6 (150 L ha(-1)), TX-VK 8 (200 L ha(-1)), AI 110015 VS (150 L ha(-1)), AI11002 VS (200 L ha(-1)) and TJ60 11002 VS (150 and 200 L ha(-1)). A randomized block design was used, with four replications. The results showed that the application of a larger spray volume increased the amount of depositions on the plants IAC Tatu ST at both stages of crop development, with the exception of spray nozzles XR 110015 VS and AI11002 VS, at the vegetative (V1) and reproductive (R2) stages of the culture, respectively; the greatest loss of drops in applications on the soil at the vegetative stage (V1) was provided by the spray nozzles AI 110015 VS and AI 11002 VS; however, at the reproductive stage (R2), the spray nozzle XR 11002 VS caused the greatest loss; The spray nozzles XR 11002 VS, AI 110015 VS, and TJ60 11002 VS (150 L ha(-1)) provided higher depositions on the leaves of B. plantaginea planted in the row than between the rows in the applications at the vegetative stage (V1), while at the reproductive stage (R2), the spray nozzles showed similar results for the deposition of droplets on the weed.
Resumo:
The objective of this study was to evaluate the effect of nozzles on spray droplet deposition in the peanut crop cultivar 'Runner IAC 886'. The study was conducted in the field, and the applications of treatments performed in the vegetative stage (V1) and reproductive (R2). It was used the Brilliant Blue FDC - 1 as tracer in water solution, at 500 ppm. The treatments consisted of seven spray nozzle XR 110015 VS (150 L ha(-1)), XR 11002 VS (200 L ha(-1)), TX-VK 6 (150L ha(-1)), TX-VK 8 (200 L ha-1), AI 110015 VS (150 L ha(-1)), AI11002 VS (200 L ha(-1)) e TJ60 11002 VS (150 e 200 L ha(-1)). It was used a randomized blocks design, with four replications. After application, plants were immediately collected, and washed in 100 mL of distilled water for posterior tracer quantification in spectrophotometer. The data had been adjusted a regression curve for Gompertz model. The results had evidenced that at low volumes of application the nozzle AI 110015 VS and TJ60 11002 VS, were the ones with best distribution uniformity of spray on plants of peanut cultivar 'Runner IAC 886' in the vegetative stage (V1) and reproductive (R2) respectively, and the largest deposits and higher percentage of failures in applications have been found in younger plants by comparing the growth stages of application, regardless of the spray nozzle and volume.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O presente trabalho teve por objetivos avaliar o espectro de gotas e os perfis de distribuição volumétrica de um bico hidráulico de jato plano de faixa expandida, modelo XR11003. Utilizou-se de analisador de partículas a laser para avaliar o espectro de gotas e de mesa de deposição para análise da distribuição volumétrica. O ensaio do espectro de gotas foi em delineamento inteiramente casualizado, em esquema fatorial 2 x 2 x 3, com três repetições, em que o primeiro fator representa o líquido pulverizado (L1 = água e L2 = água + 0,1% de espalhante adesivo não-iônico), o segundo representa a pressão de pulverização (P1 = 200 kPa e P2 = 400 kPa) e o terceiro representa três bicos hidráulicos XR11003 de jato plano (B1, B2 e B3). No ensaio de distribuição volumétrica, o delineamento foi o inteiramente casualizado, em esquema fatorial com dois fatores, não se avaliando o fator bico. Dos resultados do espectro de gotas, observaram-se maior tamanho de gotas para a pressão de 200 kPa e menor amplitude relativa quando se utilizou 0,1% de adjuvante. Para os perfis de distribuição volumétrica, ocorreu aumento na faixa de deposição e no espaçamento entre bicos com C.V. de 10%, com a adição de 0,1% de adjuvante e aumento na pressão.
Resumo:
O sucesso de uma boa aplicação de produtos fitossanitários depende da sinergia entre fatores como tamanho de gota, tipo de ponta, pressão, volume e composição da calda e características do alvo. Assim, o objetivo deste trabalho foi avaliar o espectro de gotas produzidas por pontas de jato plano defletor (TT 11002) e jato plano defletor com indução de ar (TTI 11002), com diferentes adjuvantes adicionados à calda de pulverização, pela técnica de difração de raio laser. O experimento foi conduzido em delineamento inteiramente casualizado, com quatro repetições, em esquema fatorial 2 x 5, ou seja, duas pontas de aplicação (jato plano defletor e jato plano defletor com indução de ar) e cinco composições de calda (água e água mais quatro adjuvantes: fosfatidilcoline+ácido propiônico, éter poliglicólico de monilfenol, ésteres de ácidos graxos e nonil-fenol etoxilado+óxido de etileno). em ambiente controlado, avaliou-se o espectro de gotas, por meio de um analisador a laser de gotas em tempo real, na pressão de 276 kPa. O efeito dos adjuvantes no espectro de gotas mostrou-se dependente da ponta de pulverização empregada. A adição dos adjuvantes à calda não alterou o risco potencial de deriva, expresso pela porcentagem do volume em gotas com diâmetro inferior a 100 µm, porém o adjuvante fosfatidilcoline+ácido propiônico reduziu o diâmetro da mediana volumétrica das gotas produzidas pela ponta de jato plano defletor com indução de ar, em relação à avaliação feita somente com água.
Resumo:
BACKGROUND: Retrospective analysis of human toxicity files involving topical medicines for treatment of upper airways diseases (eardrops, topical nasal medicines, lozenges, drops and sprays for oropharyngeal affections). METHODS: Thirty-four brands of eardrops, 48 of topical nasal medicines and 22 of tablets, lozenges and sprays for oropharyngeal affections were selected, from a total of 104 products available in Brazil. We analyzed the registries in the electronic database from the Poison Control Centre of São Paulo (CCI-Jabaquara), Brazil, for the period from January 1996 through December 2000. The cases related to selected pharmaceuticals were collected. RESULTS: 10,823 cases of human toxicity caused by medicines were voluntarily reported to CCI-Jabaquara. Topical medicines for treatment of upper airways diseases accounted for 291 cases (2.68%), from which 240 (82.5%) represented poisoning; 12 (4.1%) involved ear drops, 268 (92%), topical nasal medicines and 11 (3.9%), topical medicines for oropharyngeal affections. Among topical nasal medicines, vasoconstrictors predominated (233 cases), and among medicines for oropharyngeal affections, it was tetracaine (four cases). Considering age distribution, toxicity predominated significantly in children aged from 1 to 4 years (p=0.0003). The main causes of toxicity were: accidental intake of medicines (43%) and error in drug administration (14.8%). Hypereflexia and vomiting were the most frequent symptoms related to toxicity. CONCLUSIONS: There was significant incidence of systemic toxicity due to eardrops, topical nasal and oropharyngeal medicines in children 1 to 4 years-old, whose main cause was accidental intake of these medicines.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)