829 resultados para frp, compositi, fibre, legno, consolidamento


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improvements in the structural performance of glulam timber beams by the inclusion of reinforcing materials can increase both the service performance and ultimate capacity. This paper describes a series of four-point bending tests conducted, under service loads and to failure, on unreinforced, reinforced and post-tensioned glulam timber beams, where the reinforcing tendon used is 12 mm dia. basalt fibre-reinforced polymer. The research is designed to evaluate the benefits offered by including an active reinforcement in contrast to the passive reinforcement typically used within timber strengthening works, in addition to establishing the effect that bonding the reinforcing tendon has on the material's performance. Further experimental tests have also been developed to investigate the long-term implications of this research, with emphasis placed upon creep and loss of post-tensioning; however, this is ongoing and is not presented in this paper. The laboratory investigations establish that the flexural strength and stiffness increase for both the unbonded and bonded post-tensioned timbers compared to the unreinforced and reinforced beams. Timber that is post-tensioned with an unbonded basalt fibre-reinforced polymer tendon shows a flexural strength increase of 2ṡ8% and an increase in stiffness of 8ṡ7%. Post-tensioned beams with a bonded basalt fibre-reinforced polymer tendon show increases in flexural strength and stiffness of 15ṡ4% and 11ṡ5% respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improvements in the structural performance of glulam timber beams by the inclusion of reinforcing materials can improve both the service performance and ultimate capacity. In recent years research focusing on the addition of fibre reinforced polymers to strengthen members has yielded positive results. However, the FRP material is still a relatively expensive material and its full potential has not been realised in combination with structural timber. This paper describes a series of four-point bending tests that were conducted, under service and ultimate loads, on post-tensioned glulam timber beams where the reinforcing tendon used was 12 mm diameter Basalt Fibre Reinforced Polymer (BFRP). The research was designed to evaluate the additional benefits of including an active type of reinforcement, by post-tensioning the BFRP tendon, as opposed to the passive approach of simply reinforcing the timber beam.
From the laboratory investigations, it was established that there was a 16% increase in load carrying capacity, in addition to a 14% reduction in deflection under service loads when members containing the post-tensioned BFRP composite are compared with control timber specimens. Additionally a more favourable ductile failure mode was witnessed compared to the brittle failure of an unreinforced timber beam. The results support the assumption that by initially stressing the embedded FRP tendon the structural benefits experienced by the timber member increase in a number of ways, indicating that there is significant scope for this approach in practical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Timber engineering has advanced over recent decades to offer an alternative to traditional materials and methods. The bonding of fibre reinforced plastics (FRP) with adhesives to timber structures for repair and strengthening has many advantages. However, the lack of established design rules has strongly restrained the use of FRP strengthening in many situations, where these could be a preferable option to most traditional techniques. A significant body of research has been carried out in recent years on the performance of FRP reinforced timber and engineered wood products. This paper gives a State of the Art summary of material formulations, application areas, design approaches and quality control issues for practical engineers to introduce on-site bonding of FRP to timber as a new way in design for structural repair and rehabilitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The technique of externally bonding fibre reinforced polymer (FRP) composites has been becoming popular worldwide for retrofitting existing reinforced concrete (RC) structures. A major failure mode in such strengthened structures is the debonding of FRP from the concrete substrate. The bond behaviour between FRP and concrete thus plays a crucial role in these structures. The FRP-to-concrete bond behaviour has been extensively investigated experimentally, commonly using the pull-off test of FRP-to-concrete bonded joint. Comparatively, much less research has been concerned with the numerical simulation of this bond behaviour, chiefly due to difficulties in accurately modelling the complex behaviour of concrete. This paper proposes a robust finite element (FE) model for simulating the bond behaviour in the entire loading process in the pull-off test. A concrete damage plasticity model based on the plastic degradation theory is proposed to overcome the weakness of the elastic degradation theory which has been commonly adopted in previous studies. The model produces results in very close agreement with test data. © Tsinghua University Press, Beijing and Springer-Verlag Berlin Heidelberg 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Existing studies have shown conclusively that the measured fibre reinforced polymer (FRP) rupture strain in FRP wrapped concrete columns is usually significantly smaller than the rupture strain obtained from flat coupon tests. One of the main causes for this phenomenon is the existence of geometrical discontinuities at both ends of the FRP sheets. This study proposes a new strengthening method in which continuous FRP spiral wrapping is used to eliminate strain concentrations due to the geometrical discontinuities and thus increase the FRP rupture strain at column failure. The effect of the spiral angle of FRP on the FRP rupture strain in FRP wrapped specimens was experimentally investigated. The test results indicate that the spiral wrapping with a small angle with respect to the column circumference can significantly increase the strain efficiency of FRP and thus enhance the axial compression capacity of the strengthened cylinders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Strengthening RC structures with near-surface mounted (NSM) fibre reinforced polymer (FRP) composites has a number of advantages compared with that with externally bonded (EB) FRP sheets/plates. As with EB FRP, the performance of the bond between NSM FRP and concrete is one of the key factors affecting the behaviour of the strengthened structure. This paper presents a numerical investigation into the behaviour of NSM FRP loaded at its both ends to simulate the NSM FRP-toconcrete bond between two adjacent cracks in RC members. The main objective of this study is to quantitatively clarify the effect of the bondline damage during slip reversal on the ultimate load (bond strength). The results show that the bondline damage has a significant effect on the load-carrying capacity of the NSM FRP-to-concrete bonded interface and should be considered in FE modeling of the interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The tensile strength obtained from existing testing methods such as ASTM D3039, based on flat coupons, usually has a large scatter for fibre reinforced polymer (FRP) composites. This means that the measured strength may not represent the actual strength of the material, leading to under or over design. This paper develops a new interpretation method which requires fewer tests, saving money and time. Moreover the results are more consistent and more closely represent the actual strength which can lead to a safer and more economical design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concrete cover separation is a common failure mode of reinforced concrete (RC) beams strengthened with a fibre-reinforced polymer (FRP) plate bonded to the tension face (FRP-plated RC beams). Plate-end FRP U-jackets have previously been explored as a mitigation measure to delay or suppress concrete cover separation, although its effectiveness needs further clarification. The paper presents the first systemic experimental study on the use of FRP U-jackets of different forms for mitigating the concrete cover separation failure. A total of ten full-scale FRP-plated RC beams were tested. The test results show that both the ultimate load and the ductility of the beams were enhanced by the U-jackets. Among the forms of U-jackets explored, those inclined at 45o are the most effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research has shown that fibre reinforced polymer (FRP) wraps are effective for strengthening concrete columns for increased axial and flexural load and deformation capacity, and this technique is now used around the world. The experimental study presented in this paper is focused on the mechanics of FRP confined concrete, with a particular emphasis on the influence of the unconfined concrete compressive strength on confinement effectiveness and hoop strain efficiency. An experimental programme was undertaken to study the compressive strength and stress-strain behaviour of unconfined and FRP confined concrete cylinders of different concrete strength but otherwise similar mix designs, aggregates, and constituents. This was accomplished by varying only the water-to-cement ratio during concrete mixing operations. Through the use of high-resolution digital image correlation to measure both axial and hoop strains, the observations yield insights into the mechanics of FRP confinement of concretes of similar composition but with varying unconfined concrete compressive strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the experimental work carried out on a full scale concrete frame strengthened with Fibre Reinforced Polymer (FRP) composites. The frame was damaged, strengthened with FRP reinforcement and re-tested to assess the effectiveness of the strengthening technique. The natural frequencies of vibration, displacements, velocities and accelerations for both the unstrengthened and strengthened frame were recorded and compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an experimental investigation carried out on concrete filled fibre reinforced polymers (FRP) tubes, subjected to monotonic and cyclic loading. Two types of FRP materials were used: glass fibres and carbon fibres. Different failure modes and the effect of concrete fill, type of confinement materials, reinforcement ratio based on tube thickness and type of loading are examined. The study shows that external confinement of concrete by means of modern materials, such fibre reinforced polymers, can enhance its strength and ductility as well as result in large energy absorption capacity. This has important safety implications, especially in regions with seismic activity. A model that predicts the behaviour of confined concrete which takes into account the stiffness and effectiveness of different confinement materials is briefly introduced.