987 resultados para fracture healing, CYR61, vascularization, chondrogenesis, fixation stability


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the efficacy of a centrifuged osteogenic bone marrow aspirate to stimulate healing in rabbit fibular osteotomies Methods Ten white New Zealand rabbits were used A transverse medial diaphyseal fibular osteotomy was performed on the right fibula where an absorbable collagen sponge embedded in osteogenic centrifuged bone marrow aspirate obtained from the ipsilateral iliac bone was inserted The left fibula was used as the control group where the collagen absorbable sponge was inserted without the osteogenic centrifuged aspirate The rabbits were sacrificed four weeks after surgery to evaluate bone callus formation Analyses of results were performed with DEXA bone densitometry to evaluate callus mineral mass multislice computed tomography to evaluate callus volume and histomorphometry to evaluate the relative rate of tissue formation Results The employment of centrifuged osteogenic bone marrow aspirate resulted in a 40 3% increase of callus bone mineral mass and increased relative quantity of bone tissue formation by 9 4% without a significant increase in the relative quantities of cartilage fibrous tissue or in callus volume Conclusions This study shows that the centrifuged osteogenic bone marrow aspirate was able to improve the healing of experimental fibular osteotomies in rabbits

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Undernutrition can cause important functional and morphological alterations in the hematopoietic bone marrow (HBM). Degeneration of the HBM in malnourished individuals has been observed in the long bones, but none has been described in the cranial bones. Mandibular condyle fracture can lead to determine nutritional effects due to the high catabolism needed for the bone healing added to the difficulties of mastication. The aim of this study is to describe the histological aspect of HBM in the fractured mandibular condyle and in the temporal bone of malnourished rats. Thirty adult rats suffered unilateral mandibular condyle fracture and were divided into well-nourished (FG) and malnourished (MG) groups. In the MG the animals received a hypoproteic diet during the experiment. Histological sections of the temporomandibular joint were stained to visualize and quantify the HBM in this region at 24h, and 7, 15, 30, and 90 days post-fracture. At 24 hours, FG and MG showed hypocellularity and ischemic degeneration in the mandibular condyle and in the temporal bone. At 7 days, FG exhibited high cellularity in comparison with MG in the condyle; the temporal bone of both groups presented hypocellularity and degeneration. At 30 and 90 days, FG exhibited similar characteristics to those of the control; MG maintained the degeneration level mainly in the temporal bone. Malnutrition prejudices the regeneration of the HBM during a fracture healing in the temporomandibular joint. This fact contributes to a complete modification of the bone structure as well as to an impairment of the healing process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The recovery of a bone fracture is a process that is not yet fully understood. The literature conflicts on the results obtained by the interposition of foreign tissue inside a damaged bone. The objective of the present study was to ascertain the effect of placing muscle tissue between the stumps of a fractured bone. METHOD: The study was carried out on 10 rabbits divided into 2 groups (n = 5): Group 1-partial fracture of the humerus and interposition of muscle tissue; Group 2-complete fracture of the humerus and interposition of muscle tissue. The fractured limb of all animals was immobilized for 8 weeks. At the end of this time, the rabbits were killed and their operated humeri were carefully removed for roentgenological and histological assessment. RESULTS: All humeri of Group 1 recovered their integrity and normal aspect. However, the healing of the humeri of Group 2 was not perfect. Gross angulation of the bone diaphysis occurred in all animals, and immature trabecular bone, osteochondral tissue, and persistence of muscle tissue substituted normal bone. CONCLUSIONS: Interposed muscle does not affect partial bone fracture healing but causes instability in a complete fracture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dislocated compound fractures of the proximal humerus are often difficult to treat. The choice of treatment influences the final functional result. From 1984-1991 108 patients with dislocated compound fractures of the proximal humerus were operated with a T-plate osteosynthesis, retrospectively examined and classified according to the Neer-Classification. At an average follow up time of 5 years 72 patients had a clinical and radiological examination. 68% of these patients with 3-fragment fractures and 80% with 4-fragment fractures showed a modest to unsatisfactory result caused by fracture biology, imprecise fracture reduction or poor surgical procedure. Incorrect position of T-plates and inadequate material were distinguishable. The T-plate which was widely used in the late eighties for internal fixation has to be considered a failure for these particular types of fractures and should be limited for Collum chirurgicum fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past decade several new techniques for the treatment of children's fractures respecting the specificity of the growing bone have been described. The goal of all these techniques was to mechanically stabilise the fracture however to preserve a certain instability of the fracture gap itself inducing early callus formation and subsequent consolidation. The dynamic external fixation as well as the elastic stable intramedullary pinning have become accepted means in the treatment of long bone fractures in the paediatric age group. We report our experience of the last seven years with the intramedullary pinning of 105 fractures. Eighty-four were fractures of the femur, 9 of the humerus, 8 of the forearm, and a further 4 of the tibial shaft. The intramedullary elastic pinning represents a simple technique which supports or even enhances the natural process of fracture healing of the growing bone. The method is not very invasive, is cost effective, and allows short hospitalisation. Early physical activity is guaranteed due to early consolidation of the fracture. Complications are rare and the final orthopedic and cosmetic outcome is excellent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Arthrodesis of the knee by intramedullary fixation hasbeen reported to have a higher rate of success than external fixationor compression plating. Antegrade nailing however can lead to complicationsdue to the different diameters of the medullary canals, fracturesduring insertion, poor rotational stability, breakage of the IM-nailand insufficient compression at the fusion site.Method: This retrospective study reports all knee fusions performedby the same orthopaedic surgeon with the Wichita (Stryker) fusion nail(WFN) from 2004 to 2010. The Wichita nail is a short nail with a deviceat the knee which allows for coupling of differently sized and interlockedfemoral and tibial components and at the same time for compression.Results: We report of 18 patients with a mean follow up of 28 months(range 3-71 months). Infected TKA was the most common indicationfor arthrodesis in 9 cases. The remaining reasons included asepticfailed TKA in 3 cases, 2 patients after fracture, 1 patient with neurologicalinstability after knee dislocation, 1 patient after tumoral resectionand 1 non union after failed arthrodesis with long antegrade nail.Finally 1 patient with bilateral congenital knee dislocation operated onboth sides. As expected, patients receiving the WFN had undergonea large number of previous knee surgeries with a mean of 3.8 (range0-8) procedures per patient. The complication rate was 27% (5 of 18).Two patients had persistent pain requiring revision surgery to increasestability with plating. One case of periprosthetic fracture needed openreduction and internal fixation. 2 patients with superficial hematomawere treated one with open drainage and the other with physiotherapy.Infection was erradicated in all septic cases, we found no new infectionand the fusion rate was 100%.Conclusion: The results in these often difficult cases are satisfyingand we think that this technique is a valid alternative to the otherknown techniques of knee fusion in patients with a poor bone stockand fragile soft tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the results of retrograde percutaneous screw fixation (PSF) in minimally or undisplaced acetabular fractures in a geriatric population. PATIENTS AND METHODS: Between July 1998 and July 2001, 21 consecutive patients with an acetabular fracture underwent fluoroscopic guided percutaneous fixation. The mean age was 81 years (range 67--90 years). In all cases, the fracture was minimally or undisplaced (<2mm). Two cannulated cancellous 7.3mm screws were inserted in a retrograde fashion to stabilise the posterior and the anterior column. Bed to chair transfer began after 24h. Weight bearing as tolerated was allowed at 4 weeks. RESULTS: Eighteen patients were reviewed at a mean of 3.5 years (range 2--5 years). Soft tissue dissection was minimal. There were no intraoperative or postoperative complications. At the latest follow-up there was no radiographical evidence of secondary displacement of fragments, degenerative changes, or screw failure. Fractures healed at a mean time of 12 weeks (range 8--15 weeks). Clinical results were satisfactory in 17 patients. CONCLUSION: Our results show that percutaneous screw fixation under fluoroscopic control is a safe technique to treat some pattern of acetabular fracture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A group of nine patients with a diaphyseal fracture of the humerus and treated with retrograde nailing were studied with a mean follow-up of 15.3 months. Six patients with a humeral fracture without neurological deficit showed a good shoulder and elbow mobility at the last visit. Three patients with neurological lesion preoperatively suffer from a diminished range of movement not related to the surgical procedure. During the operation and postoperatively we found no complication related to the implant and more precisely we could not find a iatrogenic fracture or nervous lesion except one intraoperative lesion of the radial nerve probably related to an important traction movement during reduction with complete remission. Consolidation has been achieved for all fractures but one. This patient suffers from a lesion of the brachial plexus with complete plegia of the arm and a vascular lesion. This patient had to be reoperated for an atrophic non-union by bone grafting and plate fixation. The retrograde nail is a good implant and must be considered in our treatment plans as much as conservative treatment or surgical treatment with plating, anterograde nailing or the use of an external fixator. Only then will we be able to give to the patient the most adapted treatment for his fracture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From August 91 to December 94, 20 external fixators were used for severely injured patients (avg. ISS 25.2). The fractures were essentially open book with or without lateral compression and vertical lesions. The indication for fixation was treatment of shock and stabilization in 8 cases, stabilization alone in 9 cases, and in 3 cases as complementary fixation after internal fixation of posterior lesions. The fixation of the pelvis was effective on the amount of blood loss. One acetabulum fracture required surgery, two patients had internal fixation for loss of reduction and two others for late pubic and posterior pain. The clinical results are good; they are more related to the severity of the initial lesion than to the mode of fixation or the quality of the reduction. No superficial sepsis or osteitis was observed in relation to the pins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiostereometric analysis (RSA) is a highly accurate method for the measurement of in vivo micromotion of orthopaedic implants. Validation of the RSA method is a prerequisite for performing clinical RSA studies. Only a limited number of studies have utilised the RSA method in the evaluation of migration and inducible micromotion during fracture healing. Volar plate fixation of distal radial fractures has increased in popularity. There is still very little prospective randomised evidence supporting the use of these implants over other treatments. The aim of this study was to investigate the precision, accuracy, and feasibility of using RSA in the evaluation of healing in distal radius fractures treated with a volar fixed-angle plate. A physical phantom model was used to validate the RSA method for simple distal radius fractures. A computer simulation model was then used to validate the RSA method for more complex interfragmentary motion in intra-articular fractures. A separate pre-clinical investigation was performed in order to evaluate the possibility of using novel resorbable markers for RSA. Based on the validation studies, a prospective RSA cohort study of fifteen patients with plated AO type-C distal radius fractures with a 1-year follow-up was performed. RSA was shown to be highly accurate and precise in the measurement of fracture micromotion using both physical and computer simulated models of distal radius fractures. Resorbable RSA markers demonstrated potential for use in RSA. The RSA method was found to have a high clinical precision. The fractures underwent significant translational and rotational migration during the first two weeks after surgery, but not thereafter. Maximal grip caused significant translational and rotational interfragmentary micromotion. This inducible micromotion was detectable up to eighteen weeks, even after the achievement of radiographic union. The application of RSA in the measurement of fracture fragment migration and inducible interfragmentary micromotion in AO type-C distal radius fractures is feasible but technically demanding. RSA may be a unique tool in defining the progress of fracture union.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le desserrage des tiges est une complication fréquente des plâtres avec tiges transcorticales (TP) chez les grands animaux, nécessitant souvent leur retrait prématuré avant la guérison des fractures. Les charges excessives centrées sur le cortex à l’interface os-tige proximo-externe et disto-interne causent de l'ostéolyse. En utilisant un modèle de veau nouveau-né, ce projet a évalué un nouveau système de tige-manchon et anneau integré dans un plâtre (PS) optimisé pour réduire la contrainte péri-implant et le stress à l'interface os-implant. On a émis l'hypothèse que les PS se traduiraient par une ostéolyse péri-implant moindre par rapport aux TP. Dix veaux en bonne santé, de 3 semaines d'âge, ont été implantés avec les TP ou PS dans le métacarpe droit, à raison de 2 implants par veau. Les veaux ont été observés quotidiennement pour le confort et la boiterie et ont été euthanasiés à 28 jours. Les données recueillies comprenaient les radiographies à la chirurgie et à l'euthanasie et les mesures histomorphométriques de contact os-implant sur des échantillons non-décalcifiés avec les implants in situ. Les données ont été analysées en utilisant le test de Cochran-Mantel-Haenszel, une valeur de P <0,05 a été considérée comme significative. L'épaisseur corticale était plus importante pour les implants distaux que proximaux pour les deux groupes lors de la chirurgie (P = 0,03), mais était similaire entre les groupes (P > 0,3). Les veaux avec TP ont développé une boiterie plus tôt (au jour 21) que les veaux avec PS (P = 0,04). Histologiquement, il y avait plus de contact direct os-implant cortical pour les implants PS distaux que les implants TP (P = 0,04). La jonction métaphyso-diaphysaire osseuse où les implants proximaux étaient situés est impropre aux deux systèmes; chacun a un minimum de contact os-implant et de l'ostéolyse extensive. Le système PS n'ayant pas causé une ostéolyse importante lorsque implantés dans l'os diaphysaire et peut-être une alternative convenable aux TP pour des fractures comminutives des membres distaux.