988 resultados para food samples


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enterococci can be used in the food industry as starter or probiotic cultures. However, enterococci are also implicated in severe multi-resistant nosocomial infections. In this study, the prevalence of enterococci in selected Brazilian foodstuffs (raw and pasteurized milk, meat products, cheeses and vegetables) was evaluated. Phenotypic and PCR protocols were used for species identification. Tests for production of gelatinase, haemolysin, bacteriocin and bile salt hydrolysis were done with all enterococci isolates, whereas molecular determination of virulence markers (genes esp, gel, ace, as, efaA, hyl and cylA) and antibiotic resistance was checked only for Enterococcus faecium and Enterococcus faecalis isolates. The antibiotic-resistant isolates were assayed for biofilm formation and adhesion to mammalian cells. From the 120 food samples analyzed, 52.5% were positive for enterococci, meat and cheese being the most contaminated. E. faecium was the predominant species, followed by E. faecalis, E. casseliflavus and Enterococcus gallinarum. Phenotypic tests indicated that 67.7% of isolates hydrolyzed bile salts, 15.2% produced bacteriocin, 12.0% were beta-hemolytic and 18.2% produced gelatinase. Antibiotic resistance (gentamicin, tetracycline and erythromycin) and genes encoding for virulence traits were more frequent in E. faecalis than in E. faecium. Three E. faecium isolates were resistant to vancomycin. Among antibiotic-resistant isolates, 72.4% of E. faecalis were able to form biofilm and 13.8% to adhere to Caco-2 cells. Antibiotic-resistant E. faecalis and E. faecium isolates were grouped by RAPD-PCR and a scattered distribution was noted, indicating that resistance was not related to a particular clone. The spread of virulence/resistance traits in isolates of the two species and different RAPD-types suggest the pathogenic potential of both species. By contrast, the recovery of bacteriocinogenic E. faecium isolates with no virulence traits suggests their potential for biotechnological applications. In conclusion, our results showed that enterococci from Brazilian foods present important dualist aspects for food safety. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in foodproducing animals has received increasing attention as a contributory factor in the international emergence of antibiotic- resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOXselective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9×10-5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1×10−5 and 5.5×10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ascorbic acid is found in many food samples. Its clinical and technological importance demands an easyto- use, rapid, robust and inexpensive method of analysis. For this purpose, this work proposes a new flow procedure based on the oxidation of ascorbic acid by periodate. A new potentiometric periodate sensor was constructed to monitor this reaction. The selective membranes were of PVC with porphyrin-based sensing systems and a lipophilic cation as additive. The sensor displayed a near-Nernstian response for periodate over 1.0x10-2–6.0x10-6 M, with an anionic slope of 73.9 ± 0.9 mV decade-1. It was pH independent in acidic media and presented good selectivity features towards several inorganic anions. The flow set-up operated in double-channel, carrying a 5.0x10-4 M IO- 4 solution and a suitable buffer; these were mixed in a 50-cm reaction coil. The overall flow rate was 7 ml min-1 and the injection volume 70 µl. Under these conditions, a linear behaviour against concentration was observed for 17.7–194.0 µg ml-1, presenting slopes of 0.169 mV (mg/l)-1, a reproducibility of ±1.1 mV (n = 5), and a sampling rate of ~96 samples h-1. The proposed method was applied to the analysis of beverages and pharmaceuticals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel enzymatic biosensor for carbamate pesticides detection was developed through the direct immobilization of Trametes versicolor laccase on graphene doped carbon paste electrode functionalized with Prussianblue films (LACC/PB/GPE). Graphene was prepared by graphite sonication-assisted exfoliation and characterized by transmission electron microscopy and X-ray photoelectron spectro- scopy. The Prussian blue film electrodeposited onto graphene doped carbon paste electrode allowed considerable reduction of the charge transfer resistance and of the capacitance of the device.The combined effects of pH, enzyme concentration and incubation time on biosensor response were optimized using a 23 full-factorial statistical design and response surface methodology. Based on the inhibition of laccase activity and using 4-aminophenol as redox mediator at pH 5.0,LACC/PB/GPE exhibited suitable characteristics in terms of sensitivity, intra-and inter-day repeatability (1.8–3.8% RSD), reproducibility (4.1 and 6.3%RSD),selectivity(13.2% bias at the higher interference: substrate ratios tested),accuracy and stability(ca. twenty days)for quantification of five carbamates widely applied on tomato and potato crops.The attained detection limits ranged between 5.2×10−9 mol L−1(0.002 mg kg−1 w/w for ziram)and 1.0×10−7 mol L−1 (0.022 mg kg−1 w/w for carbofuran).Recovery values for the two tested spiking levels ranged from 90.2±0.1%(carbofuran)to 101.1±0.3% (ziram) for tomato and from 91.0±0.1%(formetanate)to 100.8±0.1%(ziram)for potato samples.The proposed methodology is appropriate to enable testing pesticide levels in food samples to fit with regulations and food inspections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Salmonella é um microrganismo responsável por grande parte das doenças alimentares, podendo por em causa a saúde pública da área contaminada. Uma deteção rápida, eficiente e altamente sensível e extremamente importante, sendo um campo em franco desenvolvimento e alvo de variados e múltiplos estudos na comunidade cientifica atual. Foi desenvolvido um método potenciométrico para a deteção de Salmonellas, com elétrodos seletivos de iões, construídos em laboratório com pontas de micropipetas, fios de prata e sensores com composição otimizada. O elétrodo indicador escolhido foi um ESI seletivo a cadmio, para redução da probabilidade de interferências no método, devido a pouca abundancia do cadmio em amostras alimentares. Elétrodos seletivos a sódio, elétrodos de Ag/AgCl de simples e de dupla juncão foram também construídos e caracterizados para serem aplicados como elétrodos de referência. Adicionalmente otimizaram-se as condições operacionais para a analise potenciométrica, nomeadamente o elétrodo de referencia utilizado, condicionamento dos elétrodos, efeito do pH e volume da solução amostra. A capacidade de realizar leituras em volumes muito pequenos com limites de deteção na ordem dos micromolares por parte dos ESI de membrana polimérica, foi integrada num ensaio com um formato nao competitivo ELISA tipo sanduiche, utilizando um anticorpo primário ligado a nanopartículas de Fe@Au, permitindo a separação dos complexos anticorpo-antigénio formados dos restantes componentes em cada etapa do ensaio, pela simples aplicação de um campo magnético. O anticorpo secundário foi marcado com nanocristais de CdS, que são bastante estáveis e é fácil a transformação em Cd2+ livre, permitindo a leitura potenciométrica. Foram testadas várias concentrações de peroxido de hidrogénio e o efeito da luz para otimizar a dissolução de CdS. O método desenvolvido permitiu traçar curvas de calibração com soluções de Salmonellas incubadas em PBS (pH 4,4) em que o limite de deteção foi de 1100 CFU/mL e de 20 CFU/mL, utilizando volumes de amostra de 10 ƒÊL e 100 ƒÊL, respetivamente para o intervalo de linearidade de 10 a 108 CFU/mL. O método foi aplicado a uma amostra de leite bovino. A taxa de recuperação media obtida foi de 93,7% } 2,8 (media } desvio padrão), tendo em conta dois ensaios de recuperação efetuados (com duas replicas cada), utilizando um volume de amostra de 100 ƒÊL e concentrações de 100 e 1000 CFU/mL de Salmonella incubada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≤9.8 %) and accuracy (recoveries ≥96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Botulism is a rare and potentially lethal illness caused by Clostridium botulinum neurotoxin. We describe the findings of a laboratorial investigation of 117 suspected cases of botulism reported to the surveillance system in Brazil from January 2000 to October 2008. Data on the number and type of samples analyzed, type of toxins identified, reporting of the number of botulism cases and transmission sources are discussed. A total of 193 clinical samples and 81 food samples were analyzed for detection and identification of the botulism neurotoxin. Among the clinical samples, 22 (11.4%) presented the toxin (nine type A, five type AB and eight with an unidentified type); in food samples, eight (9.9%) were positive for the toxin (five type A, one type AB and two with an unidentified type). Of the 38 cases of suspected botulism in Brazil, 27 were confirmed by a mouse bioassay. Laboratorial botulism diagnosis is an important procedure to elucidate cases, especially food-borne botulism, to confirm clinical diagnosis and to identify toxins in food, helping sanitary control measures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Considerando que a pressão arterial elevada constitui um dos maiores fatores de risco para as doenças cardiovasculares, a sua associação ao consumo elevado de sal, e o facto das escolas constituírem ambientes de excelência para a aquisição de bons hábitos alimentes e promoção da saúde, o objetivo deste estudo foi avaliar o conteúdo de sal presente nas refeições escolares e a perceção dos consumidores sobre o sabor salgado. A quantificação de sal foi realizada com um medidor portátil. Para avaliar a perceção dos consumidores foi desenvolvido e aplicado um questionário a alunos das escolas preparatórias e secundárias e aos responsáveis pela preparação e confeção das refeições. Foram analisadas um total de 898 componentes de refeições, incluindo refeições escolares e de restauração padronizada. Em média, as refeições escolares disponibilizam entre 2,83 a 3,82 g de sal por porção servida (p=0,05), o que representa entre duas a cinco vezes mais as necessidades das crianças e jovens. Os componentes das refeições padronizadas apresentam um valor médio de sal que varia entre 0,8 e 2,57 g por porção (p=0,05), o que pode contribuir para um valor total de sal por refeição mais elevado comparativamente com as refeições escolares. O sabor das refeições é percecionado como sendo nem salgado nem insonso para a maioria dos estudantes, o que parece demonstrar habituação à intensidade/ quantidade de sal consumida. Os responsáveis pelas refeições, apesar de apresentarem conhecimentos sobre sal e a necessidade da sua limitação, demonstram barreiras e limitações e perceções à sua redução. A realização de escolhas alimentares saudáveis e adequadas só é possível se suportada por um ambiente facilitador dessas mesmas escolas. O impacto que o consumo de sal tem na saúde, em particular nas doenças crónicas, torna imperativa a implementação de estratégias de redução de sal ao nível da indústria e dos serviços de catering e restauração, em particular direcionadas para o público mais jovem.------------ABSTRACT Considering the fact that high blood pressure is a major rick factor for cardiovascular disease and its association to salt intake and the fact that schools are considered ideal environments to promote health and proper eating habits, the objective of this study was to evaluate the amount of salt in meals served in school canteens and consumers perceptions about salt. Quantification of salt was performed using a portable salt meter - PAL ES2. For food perception we constructed a questionnaire that was applied to students from high schools. A total of 898 food samples were analysed. Bread presents the highest value with a mean of 1.35 (SD=0.12). Salt in soups ranges from 0.72 g/100 g to 0.80 g/100 g (p=0.05) and main courses from 0.71 g/100 to 0.97 g/100g (p=0.05). Salt in school meals is high with a mean value from 2.83 to 3.82 g of salt per meal, which is between 2 and 5 times more than the RDA for children. The components of standardized meals have an average value of salt ranging from 0.8 to 2.57 g per serving, which may contribute to a higher intake of salt per meal compared to school meals. Moreover, a high percentage of students consider meals neither salty nor lacking in salt, which shows they are used to the intensity/amount of salt consumed. Despite the knowledge and perceived necessity about salt reduction, those responsible for cooking and preparing meals, still demonstrate barriers and limitation in doing so. Making healthy choices is only possible if backed up by an environment where such choices are accessible. Therefore salt reduction strategies, aimed at the food industry and catering services should be implemented, with children and young people targeted as a major priority.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this review we highlight recent work that has increased our understanding of the distribution of Shiga toxin-converting phages that can be detected as free phage particles, independently of Shiga toxin-producing bacteria (STEC). Stx phages are a quite diverse group of temperate phages that can be found in their prophage state inserted within the STEC chromosome, but can also be found as phages released from the cell after activation of their lytic cycle. They have been detected in extraintestinal environments such as water polluted with feces from humans or animals, food samples or even in stool samples of healthy individuals. The high persistence of phages to several inactivation conditions makes them suitable candidates for the successful mobilization of stx genes, possibly resulting in the genes reaching a new bacterial genomic background by means of transduction, where ultimately they may be expressed, leading to Stx production. Besides the obvious fact that Stx phages circulating between bacteria can be, and probably are, involved in the emergence of new STEC strains, we review here other possible ways in which free Stx phages could interfere with the detection of STEC in a given sample by current laboratory methods and how to avoid such interference.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Potentiometric Stripping Analysis (PSA) is described with emphasis on ultramicroelectrode applications with a laboratory developed computer based instrumentation. The technique potentialities as compared with the voltammetric approach are pointed out based on the current literature. Some results of trace metals analysis including zinc, cadmium, lead and copper in vinegar and canned food samples are presented. The mainly advantage found in our laboratory was the technique capability to analyse natural samples with minimum matrix interference and the low level of noise found in our determinations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A brief discussion about the hydrogen peroxide importance and its determination is presented. It was emphasized some consideration of the H2O2 as reagent (separated or combined), uses and methods of analysis (techniques, detection limits, linear response intervals, sensor specifications). Moreover, it was presented several applications, such as in environmental, pharmaceutical, medicine and food samples.