110 resultados para flicker


Relevância:

10.00% 10.00%

Publicador:

Resumo:

En aquest treball de final de carrega s¿ha desenvolupat una aplicació que permet la gestió d¿imatges geoetiquetades publicades en els sistemes Flicker i PicasaWeb fent servir les tecnologies de Microsoft .NET i els serveis web que ofereixen les APIs públiques d¿aquestssistemes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:To functionally and morphologically characterize the retina and optic nerve after transplantation of Brain-derived neurotrophic factor (BDNF) and Glial-derived neurotrophic factor (GDNF) secreting mesenchymal stem cells (MSCs) into glaucomatous rat eyes. Methods:Chronic ocular hypertension (COH) was induced in Brown Norway rats. Lentiviral constructs were used to transduce rat MSCs to produce BDNF, GDNF, or green fluorescent protein (GFP). The fellow eyes served as internal controls. Two days following COH induction, eyes received intravitreal injections of transduced MSCs. Electroretinography was performed to assess retinal function. Tonometry was performed throughout the experiment to monitor IOP. 42 days after MSC transplantation, rats were euthanized and the eyes and optic nerves were prepared for analysis. Results:Increased expression and secretion of BDNF and GDNF from lentiviral-transduced MSCs was verified using ELISA, and a bioactivity assay. Ratio metric analysis (COH eye/ Internal control eye response) of the Max combined response A-Wave showed animals with BDNF-MSCs (23.35 ± 5.15%, p=0.021) and GDNF-MSCs (28.73 ± 3.61%, p=0.025) preserved significantly more visual function than GFP-MSC treated eyes MSCs (18.05 ± 5.51%). Animals receiving BDNF-MSCs also had significantly better B-wave (33.80 ± 7.19%) and flicker ERG responses (28.52 ± 10.43%) than GFP-MSC treated animals (14.06 ± 12.67%; 3.52 ± 0.07%, respectively). Animals receiving GDNF-MSC transplants tended to have better function than animals with GFP-MSC transplants, but were not statistically significant (p=0.057 and p=0.0639). Conclusions:Mesenchymal stem cells are an excellent source of cells for autologous transplantation for the treatment of neurodegenerative diseases. We have demonstrated that lentiviral- transduced MSCs can survive following transplantation and preserve visual function in glaucomatous eyes. These results suggest that MSCs may be an ideal cellular vehicle for delivery of specific neurotrophic factors to the retina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Gene therapy of severe retinal dystrophies directly affecting photoreceptor is still a challenge in terms of clinical application. One of the main hurdles is to generate high transgene expression specifically in rods or cones. In the present study, we are investigating the possibility to drive hPDE6b expression in the Rd10 mouse retina using a specific sequence of the human PDE6b promoter. Methods: Two 5' flanking fragments of the human PDE6b gene: (-93 to +53 (146 bp) and -297 to +53 (350 bp, see Di Polo and Farber, 1995) were cloned in different plasmids in order to check their expression in vitro and in vivo. These elements drove the activity of either luciferase (pGL3 plasmids) or EGFP (AAV2/8 backbone). Then, an AAV2/8 vector carrying the PDE6b cDNA was tested with subretinal injections at P9 in the Rd10 eyes. Eye fundus, OCT, ERG recordings and histological investigations were performed to assess the efficacy of the gene transfer. Results: The short PDE6b promoter containing 146bp (-93 to +53) showed the highest activity in the Y-79 cells, as described previously (Di Polo and Farber, 1995). Subretinal administrations of AAV2/8-PDE6bpromoter-EGFP allowed a rapid expression specifically in rods and not in cones. The expression is faster than a vector containing the CMV promoter. The AAV2/8-PDE6bpromoter-PDE6b and the control vector were injected at P9 in the Rd10 mouse retina and investigated 5 weeks post-injection. Out of 14 eyes, 6 presented an increased rod sensitivity of about 300 fold, and increased a- and b-wave responses in ERG recordings. Flicker stimulations revealed that cones are also functional. OCT images and histological analyses revealed an increased ONL size in the injected area. The retina treated with the therapeutic vector presented 4-6 rows of photoreceptors with outersegments containing PDE6b. In the control eyes, only 2-4 rows of photoreceptors with almost no OS were observed . Conclusions: The 146 bp promoter sequence (-93 to + 53) is the shortest regulatory element described to date which allows to obtain efficient rod-specific expression in the context of somatic gene transfer. This first result is of great interest for AAV vector design in general allowing more space for the accommodation of transgenes of interest and good expression in rods. Moreover we showed the proof of principle of the efficacy of AAV2/8-PDE6bp-PDE6b vector in the Rd10 mouse model of severe photoreceptor degeneration without using neither AAV mutated capsids, nor self-complementary vectors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retinitis pigmentosa (RP) is a hereditary disease that leads to the progressive degeneration of retinal photoreceptor cells and to blindness. It is caused by mutations in several distinct genes, including the ciliary gene FAM161A, which is associated with a recessive form of this disorder. Recent investigations have revealed that defects in FAM161A represent a rather prevalent cause of hereditary blindness in Israel and the Palestinian territories, whereas they seem to be rarely present within patients from Germany. Genetic or clinical data are currently not available for other countries. In this work, we screened a cohort of patients with recessive RP from North America to determine the frequency of FAM161A mutations in this ethnically-mixed population and to assess the phenotype of positive cases. Out of 273 unrelated patients, only 3 subjects had defects in FAM161A. A fourth positive patient, the sister of one of these index cases, was also identified following pedigree analysis. They were all homozygous for the p.T452Sfx3 mutation, which was previously reported as a founder DNA variant in the Israeli and Palestinian populations. Analysis of cultured lymphoblasts from patients revealed that mutant FAM161A transcripts were actively degraded by nonsense-mediated mRNA decay. Electroretinographic testing showed 30 Hz cone flicker responses in the range of 0.10 to 0.60 microvolts in all cases at their first visit (age 12 to 23) (lower norm  =  50 μV) and of 0.06 to 0.32 microvolts at their most recent examination (age 27 to 43), revealing an early-onset of this progressive disease. Our data indicate that mutations in FAM161A are responsible for 1% of recessive RP cases in North America, similar to the prevalence detected in Germany and unlike the data from Israel and the Palestinian territories. We also show that, at the molecular level, the disease is likely caused by FAM161A protein deficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To report the clinical and genetic study of a family with Leber congenital amaurosis (LCA). Methods: We studied a consanguineous family from Yemen in which three individuals were affected with LCA. Genomic DNA was prepared from venous leukocytes. Linkage analysis of all family members using polymorphic markers flanking the known LCA genes was performed, followed by direct sequencing of all the exons and intron-exon junctions of the RPE65 gene. Results: The three affected were 5, 8 and 12 years old. Severe visual impairment and night blindness were noticed during infancy. Nystagmus was not a feature. Photophobia was only observed in the 8-year-old patient. The 5-year old youngest affected had a bilateral hyperopia of +3.50 and a visual acuity of 1/60. The oldest two had mild myopia and visual acuity limited to hand movements RE and counting fingers LE for the oldest and of 5/60 OD, 6/60 OS for the other. On fundus examination, they harbored common clinical features such as disc pallor, attenuated vessels, white flecks in the retina mid-periphery and bull's eye maculopathy. Electroretinograms of the oldest child were completely extinguished while residual scotopic responses with abolished photopic and flicker responses were observed in the two youngest. Sequencing identified a novel missense mutation, IVS2-3C>G, in the second RPE65 intron. The mutation was not detected in 80 ethnically matched normal individuals. Conclusion: We have identified a novel LCA-related homozygous RPE65 mutation associated with a severe clinical presentation including an early and severe cone dysfunction. This is in contrast with the presentation associated with other RPE65 mutations predominantly causing a rod-cone dystrophy with residual cone function. The identified mutation potentially affects splicing of the third exon and could result in a loss of function. Definite functional consequences of this change still need to be characterized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Complete achromatopsia is a rare autosomal recessive disease due to CNGA3, CNGB3, GNAT2 and PDE6C mutations. We studied a large consanguineous Tunisian family including twelve individuals.Methods: Ophthalmic evaluation included a full clinical examination, color vision testing, optical coherence tomography and electroretinography. Linkage analysis using microsatellite markers flanking CNGA3, CNGB3, GNAT2 and PDE6C genes was performed. Mutations were screened by direct sequencing.Results: In all affected subjects, acuity ranged from 20/50 to 20/200. Fundus examination was normal except for two patients who had respectively 4 mm and 5 mm diameters of peripheral congenital hypertrophy. Likewise retinal layers exploration by OCT revealed no change in the thickness of the central retina. Color Vision with 100 Hue Farnsworth test described a profound color impairment along all three axes of color vision. The haplotype analysis of GNAT2 markers revealed that all affected offspring were homozygous by descent for the four polymorphic markers. The maximum lod score value, 4.33, confirmed the evidence for linkage to the GNAT2 gene.A homozygous novel nonsense mutation R313X was identified segregating with an identical GNAT2 haplotype in all affected subjects. This mutation could interrupt interaction with photoactivated rhodopsin, resulting in a failure of visual transduction. In fact, ERG showed a clearly abolished photopic b-wave and flicker responses with no residual cone function justifying the severe GNAT2 achromatopsia phenotype.Conclusions: This is the first report of the clinical and genetic investigation of complete achromatopsia in North Africa and of the largest family with recessive achromatopsia involving GNAT2, thus providing a unique opportunity for genotype phenotype correlation for this extremely rare condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssä tutkitaan muuttuvanopeuksisen tuulivoimakäytön verkkoliityntöjä, verkkomääräyksiä ja mittausmenetelmiä Euroopassa. Yleiset tuulivoimalaitoksen verkkomääräyksiin liittyvät asiat on selitetty standardisarjassa IEC 61000 ja mittauksiin liittyvät säännökset standardissa IEC 61400-21. Työssä selvitetään Euroopan yleiset verkkomääräykset ja vertaillaan niitä keskenään, sekä määritetään tärkeimmät mittaukset. Lisäksi esitellään eräs standardimittauksiin soveltuva mittalaite ja analysoidaan täystehomuokkaimen suorituskykyä tuulivoimapuistossa. Työssä havaittiin, että standardin mukaisten mittausten toteuttaminen ja analysointi on hyvin haastava prosessi. Verkkomääräysten eroavaisuudet aiheuttavat hankaluuksia tuulivoimalan valmistajan ja verkko-operaattorien välillä. Täten myös konvertterivalmistajan täytyy olla selvillä käytössä olevista verkkomääräyksistä ja standardeista.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the commonest ocular disorder, dense cataracts disable fundoscopic examination and the diagnosis of retinal disorders, which dogs may be predisposed. The aim of this study was to compare the electroretinographic responses recorded according to the International Society for Clinical Electrophysiology of Vision human protocol to evaluate retinal function of diabetic and non diabetic dogs, both presenting mature or hypermature cataracts. Full-field electroretinogram was recorded from 66 dogs, with ages varying from 6 to 15 years old allocated into two groups: (1) CG, non diabetic cataractous dogs, and (2) DG, diabetic cataractous dogs. Mean peak-to-peak amplitude (microvolts) and b-wave implicit time (milliseconds) were determined for each of the five standard full-field ERG responses (rod response, maximal response, oscillatory potentials, single-flash cone response and 30 Hz flicker). Comparing CG to DG, ERGs recorded from diabetic dogs presented lower amplitude and prolonged b-wave implicit time in all ERG responses. Prolonged b-wave implicit time was statistically significant (p< 0.05) at 30 Hz flicker (24.0 ms versus 22.4 ms). These data suggests full-field ERG is capable to record sensible alterations, such as flicker's implicit time, being useful to investigate retinal dysfunction in diabetic dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and a fiber electrode prototype. The examinations were performed during 2 visits, 3 weeks apart. Both electrodes (ERG-Jet or fiber prototype) were used on each animal and the first eye to be recorded (OD × OS) was selected randomly. Three weeks later the examination was repeated on the same animal switching the type of electrode to be used that day and the first eye to be examined. The magnitude and waveform quality obtained with the two electrode types were similar for all ERG responses. ERG amplitudes and implicit times obtained from dogs using the fiber electrode prototype were comparable to those obtained with the ERG-Jet electrode for rod, maximal rod-cone summed, cone, and 30-Hz flicker responses. The fiber electrode prototype is a low-cost device, available as an alternative instrument for clinical veterinary ERG recording for retinal function assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A good teacher was once described as being like a candle; consuming itself to light the way for others (Author unknown). But as Knox (2005) says, far too many yoimg flames flicker out before they ever get the opportvmity to bum their brightest. This self-study explores the phenomenon of teacher attrition through the stories and lived experiences of one elementary teacher. I strive throughout this self-study to delve deeper into the significance of my story and lived experiences in order to enhance our understanding of why teachers exit the profession. As a result, the guiding question throughout the study is, "Why do teachers, particularly those who have only taught for a few years, leave the classrooms they worked so hard to enter?" Through the writing of a narrative entitled Sarah 's Story, I was able to identify and give voice to a story openly sharing the feelings of despair; disappointment, frustration and disillusionment. This study has identified areas of tension that lead to dissatisfaction, discontent, and teacher disillusionment. It confronts the issues of complexity, uncertainty, and conflict that are experienced in teaching. It discusses the puzzling, powerfiil and upsetting experiences, highlighting the importance of talk between all members of the education system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’influence de la couleur dans les mécanismes perceptuels et attentionnels a été étudiée. Quatre couleurs (le rouge, le vert, le bleu et le jaune) ont été calibrées individuellement à travers la technique heterochromatic flicker photometry. Suivant cela, les participants ont déployé leur attention à une cible (un cercle de couleur avec une ligne orientée). Les données électrophysiologiques ont été enregistrées pendant que les sujets performaient la tâche de recherche visuelle, et les analyses ont été basées sur les potentiels évoqués (PÉs). Trois composantes des PÉs ont été examinées : la posterior contralateral positivity (Ppc); la N2pc, reflétant le déploiement de l’attention visuo-spatiale et la temporal and contralateral positivity (Ptc). Des conditions dans lesquelles la cible était bleu ou rouge, lorsque comparées à des conditions avec une cible jaune ou verte suscitaient une N2pc plus précoce. Une amplitude plus élevée est aussi observée pour les cibles rouges pour les composantes Ppc et Ptc, reflétant une sélectivité pré-attentionelle. Ces résultats suggèrent de la prudence dans l’interprétation de données comparant des cibles de différentes couleurs dans des tâches de PÉs, et ce même lorsque les couleurs sont équiluminantes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le traumatisme craniocérébral léger (TCCL) a des effets complexes sur plusieurs fonctions cérébrales, dont l’évaluation et le suivi peuvent être difficiles. Les problèmes visuels et les troubles de l’équilibre font partie des plaintes fréquemment rencontrées après un TCCL. En outre, ces problèmes peuvent continuer à affecter les personnes ayant eu un TCCL longtemps après la phase aiguë du traumatisme. Cependant, les évaluations cliniques conventionnelles de la vision et de l’équilibre ne permettent pas, la plupart du temps, d’objectiver ces symptômes, surtout lorsqu’ils s’installent durablement. De plus, il n’existe pas, à notre connaissance, d’étude longitudinale ayant étudié les déficits visuels perceptifs, en tant que tels, ni les troubles de l’équilibre secondaires à un TCCL, chez l’adulte. L’objectif de ce projet était donc de déterminer la nature et la durée des effets d’un tel traumatisme sur la perception visuelle et sur la stabilité posturale, en évaluant des adultes TCCL et contrôles sur une période d’un an. Les mêmes sujets, exactement, ont participé aux deux expériences, qui ont été menées les mêmes jours pour chacun des sujets. L’impact du TCCL sur la perception visuelle de réseaux sinusoïdaux définis par des attributs de premier et de second ordre a d’abord été étudié. Quinze adultes diagnostiqués TCCL ont été évalués 15 jours, 3 mois et 12 mois après leur traumatisme. Quinze adultes contrôles appariés ont été évalués à des périodes identiques. Des temps de réaction (TR) de détection de clignotement et de discrimination de direction de mouvement ont été mesurés. Les niveaux de contraste des stimuli de premier et de second ordre ont été ajustés pour qu’ils aient une visibilité comparable, et les moyennes, médianes, écarts-types (ET) et écarts interquartiles (EIQ) des TR correspondant aux bonnes réponses ont été calculés. Le niveau de symptômes a également été évalué pour le comparer aux données de TR. De façon générale, les TR des TCCL étaient plus longs et plus variables (plus grands ET et EIQ) que ceux des contrôles. De plus, les TR des TCCL étaient plus courts pour les stimuli de premier ordre que pour ceux de second ordre, et plus variables pour les stimuli de premier ordre que pour ceux de second ordre, dans la condition de discrimination de mouvement. Ces observations se sont répétées au cours des trois sessions. Le niveau de symptômes des TCCL était supérieur à celui des participants contrôles, et malgré une amélioration, cet écart est resté significatif sur la période d’un an qui a suivi le traumatisme. La seconde expérience, elle, était destinée à évaluer l’impact du TCCL sur le contrôle postural. Pour cela, nous avons mesuré l’amplitude d’oscillation posturale dans l’axe antéropostérieur et l’instabilité posturale (au moyen de la vitesse quadratique moyenne (VQM) des oscillations posturales) en position debout, les pieds joints, sur une surface ferme, dans cinq conditions différentes : les yeux fermés, et dans un tunnel virtuel tridimensionnel soit statique, soit oscillant de façon sinusoïdale dans la direction antéropostérieure à trois vitesses différentes. Des mesures d’équilibre dérivées de tests cliniques, le Bruininks-Oseretsky Test of Motor Proficiency 2nd edition (BOT-2) et le Balance Error Scoring System (BESS) ont également été utilisées. Les participants diagnostiqués TCCL présentaient une plus grande instabilité posturale (une plus grande VQM des oscillations posturales) que les participants contrôles 2 semaines et 3 mois après le traumatisme, toutes conditions confondues. Ces troubles de l’équilibre secondaires au TCCL n’étaient plus présents un an après le traumatisme. Ces résultats suggèrent également que les déficits affectant les processus d’intégration visuelle mis en évidence dans la première expérience ont pu contribuer aux troubles de l’équilibre secondaires au TCCL. L’amplitude d’oscillation posturale dans l’axe antéropostérieur de même que les mesures dérivées des tests cliniques d’évaluation de l’équilibre (BOT-2 et BESS) ne se sont pas révélées être des mesures sensibles pour quantifier le déficit postural chez les sujets TCCL. L’association des mesures de TR à la perception des propriétés spécifiques des stimuli s’est révélée être à la fois une méthode de mesure particulièrement sensible aux anomalies visuomotrices secondaires à un TCCL, et un outil précis d’investigation des mécanismes sous-jacents à ces anomalies qui surviennent lorsque le cerveau est exposé à un traumatisme léger. De la même façon, les mesures d’instabilité posturale se sont révélées suffisamment sensibles pour permettre de mesurer les troubles de l’équilibre secondaires à un TCCL. Ainsi, le développement de tests de dépistage basés sur ces résultats et destinés à l’évaluation du TCCL dès ses premières étapes apparaît particulièrement intéressant. Il semble également primordial d’examiner les relations entre de tels déficits et la réalisation d’activités de la vie quotidienne, telles que les activités scolaires, professionnelles ou sportives, pour déterminer les impacts fonctionnels que peuvent avoir ces troubles des fonctions visuomotrice et du contrôle de l’équilibre.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resumen basado en el de la publicación

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Snakes are thought as fear-relevant stimuli (biologically prepared to be associated with fear) which can lead to an enhanced attentional capture when compared fear-irrelevant stimuli. Inherent limitations related to the key-press behaviour might be bypassed with the measurement of eye movements, since they are more closely related to attentional processes than reaction times. An eye tracking technique was combined with the flicker paradigm in two studies. A sample of university students was gathered. In both studies, an instruction to detect changes between the pair of scenes was given. Attentional orienting for the changing element in the scene was analyzed, as well the role of fear of snakes as a moderator variable. The results for both studies revealed a significant shorter time to first fixation for snake stimuli when compared to control stimuli. A facilitating effect of fear of snakes was also found for snakes, presenting the highly fear participants a shorter a time to first fixation for snake stimuli when compared to low-feared participants. The results are in line with current research that supports the advantage of snakes to grab attention due their evo-biological significance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a visual stimulus generator (VSImG) capable of displaying a gray-scale, 256 x 256 x 8 bitmap image with a frame rate of 500 Hz using a boustrophedonic scanning technique. It is designed for experiments with motion-sensitive neurons of the fly`s visual system, where the flicker fusion frequency of the photoreceptors can reach up to 500 Hz. Devices with such a high frame rate are not commercially available, but are required, if sensory systems with high flicker fusion frequency are to be studied. The implemented hardware approach gives us complete real-time control of the displacement sequence and provides all the signals needed to drive an electrostatic deflection display. With the use of analog signals, very small high-resolution displacements, not limited by the image`s pixel size can be obtained. Very slow image displacements with visually imperceptible steps can also be generated. This can be of interest for other vision research experiments. Two different stimulus files can be used simultaneously, allowing the system to generate X-Y displacements on one display or independent movements on two displays as long as they share the same bitmap image. (C) 2011 Elsevier B.V. All rights reserved.