999 resultados para filling technique
Resumo:
Purpose: To present a technique for filling facial folds by using autologous orbicularis oculi muscle, based on an experimental model. Methods: two studies are presented: (1) an experimental study using 15 albino guinea-pigs from which a strip of the sural triceps muscle was removed and implanted in the subcutaneous tissue of the dorsal area. The animals were sacrificed 7, 30 and 60 days after the implantation, and the material was histologically evaluated. And (2%) an interventional prospective clinical trial carried out on 20 patients referred to blepharoplasty surgery. They received autologous preseptal orbicularis muscle for filling facial folds. The results where evaluated by patients satisfaction and clinical exam. Results: the sural tricep muscle, when implanted in the subcutaneous tissue, resulted in fibrosis. The patients whom received autologous orbicularis muscle implanted for filling facial folds showed that the procedure can be successfully carried out. Conclusions: autologous preseptal orbicularis muscle is a good material for filling facial folds. Cicatricial tissue will be formed on its implantation site, filling the tissue gap that forms the folds on the skin.
Resumo:
The aim of this study was to investigate the apical leakage of roots filled by three different gutta-percha techniques: lateral condensation, Tagger's hybrid and E&Q Master. Forty-two extracted single-rooted teeth were used. The coronal part of each tooth was removed and the root received biomechanical preparation using a 60-K file. The roots were randomly divided into three groups according to the technique of filling the root canal: Group I, lateral condensation; Group II, Tagger's hybrid; Group III, E&Q Master. The roots were submitted to dye leakage test with Rhodamine B for 7 days, using vacuum during the initial 30 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. Statistical analysis indicated that lateral condensation and E&Q Master techniques showed lower leakage than Tagger's technique (P = 0.0016). However, statistically no difference was found between lateral condensation and E&Q Master system techniques.
Resumo:
Despite the excellent properties of mineral trioxide aggregate (MTA), the condensation technique may have some influence in its sealing ability. The purpose of this study was to compare the sealing ability of sonic and ultrasonic setting of MTA. Thirty-four extracted human teeth had their canals prepared and filled with Sealapex sealer and gutta-percha using the active lateral condensation technique. The teeth were rendered waterproof and apicoectomy performed at 3 mm from the apex. Root-end cavities (3.0 mm deep and 1.4 mm diameter) were prepared with diamond ultrasonic tips. The root-end cavities were filled with Pro-Root MTA® with ultrasonic vibration, sonic vibration or no vibration. The positive control group did not receive any material while the negative control group was totally rendered waterproof. After material set, the specimens were immersed in Rodhamine B for 24 h, under vacuum in the first 15 min, then washed, dried and split longitudinally for evaluating the infiltration at the dentin/material interface. Data were analyzed using ANOVA and Tukey's tests at 5% significance level. Sonic vibration promoted the lowest infiltration values (p<0.05). It was concluded that sonic vibration could be considered an efficient aid to improve the sealing ability of MTA when used as root-end filling material.
Resumo:
Aim To assess (i) heat generated by pluggers during warm vertical compaction of gutta-percha and investigation of temperature changes on the external root surface during canal filling, and (ii) the chemical changes of root canal sealers induced by heat.Methodology Four sealers, namely AH Plus, MTA Plus and two other experimental sealers based on tricalcium silicate, were characterised. External temperatures generated on the root surface during warm vertical compaction of gutta-percha with different sealers inside the root canal were monitored using an infrared thermography camera. Chemical changes induced by heating the sealers were assessed by Fourier transform infrared (FT-IR) spectroscopy.Results MTA Plus and the experimental sealers were composed of a cement and radiopacifier, with epoxy resin or a water-soluble polymer as dispersant, whilst AH Plus was epoxy resin-based. The heat generated at the tips of the continuous wave pluggers was found to be lower than the temperature set and indicated on the device LCD display. The sealers reduced the heat generated on the external root surfaces during the heating phase. AH Plus sustained changes to its chemical structure after exposure to heat, whilst the other sealers were unaffected.Conclusions The temperatures recorded at the tips of continuous wave pluggers varied with their taper and were lower than the temperature set on the System B LCD display. Root canal sealers reduced the dissipation of heat generated during warm vertical compaction, with the temperature at the external root surface maintained at 37-41 degrees C, a temperature below that is necessary to cause irreversible damage to bone and periodontium. The use of AH Plus sealer during warm vertical compaction techniques results in chemical changes in the sealer. The effect on sealer properties needs to be further investigated.
Resumo:
Aim: To evaluate the effectiveness of ProTaper universal retreatment system in the removal of root canal filling material with thermomechanical compaction, in comparison to manualmechanical technique, associated with orange oil or eucalyptol. Materials and methods: Forty extracted lower incisors were filled with thermomechanical compaction technique. After 3 years, the root canal filling was removed by: G1 - manualmechanical technique with orange oil; G2 - manual-mechanical technique with eucalyptol; G3 - ProTaper universal retreatment system with orange oil and G4 - ProTaper universal retreatment system with eucalyptol. In sequence, all root canals were instrumented to F5 instrument. The teeth were longitudinally grooved, images of buccal half were obtained in stereomicroscope and covered area by root canal filling material was measured using image tool software, in cervical, middle and apical radicular thirds. The results were subjected ANOVA and Tukey test (p = 0.05). Results: In all thirds, the manual-mechanical technique showed lower presence of root canal filling material on root canal dentin in comparison to ProTaper retreatment universal system, regardless of organic solvent used (p < 0.05). There is no difference between organic solvents in removal root canal filling material (p > 0.05). Conclusion: The ProTaper universal retreatment system showed lower effectiveness in removal root canal filling material than manual-mechanical technique, regardless of organic solvents (orange oil or eucalyptol oil) used. Clinical significance: Recently rotary instruments have been proposed to removal of root canal filling material. However, there are no studies evaluating its effectiveness in removal root canal filling material in association with orange oil or eucalyptol oil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To investigate the periapical tissue response of 4 different retrograde root-filling materials, ie, intermediate restorative material, thermoplasticized gutta-percha, reinforced zinc oxide cement (Super-EBA), and mineral trioxide aggregate (MTA), in conjunction with an ultrasonic root-end preparation technique in an animal model. Materials and Methods: Vital roots of the third and fourth right mandibular premolars in 6 healthy mongrel dogs were apicectomized and sealed with 1 of the materials using a standardized surgical procedure. After 120 days, the animals were sacrificed and the specimens were analyzed radiologically, histologically, and scanning electron microscopically. The Fisher exact test was performed on the 2 outcome values. Results: Twenty-three sections were analyzed histologically. Evaluation showed better re-establishment of the periapical tissues and generally lower inflammatory infiltration in the sections from teeth treated with the intermediate restorative material and the MTA. New root cement on the resected dentin surfaces was seen on all sections regardless of the used material. New hard tissue formation, directly on the surface of the material, was seen only in the MTA sections. There was no statistical difference in outcome among the tested materials. Conclusions: The results from this dog model favor the intermediate restorative material and MTA as retrograde fillings when evaluating the bone defect regeneration. MTA has the most favorable periapical tissue response when comparing the biocompatibility of the materials tested. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:2041-2047, 2012
Resumo:
Objective: The aim of this study was to compare the correspondence between gap formation and apical microleakage in root canals filled with epoxy resin-based (AH Plus) combined or not with resinous primer or with a dimethacrylate-based root canal sealer (Epiphany). Material and Methods: Thirty-nine lower single-rooted human premolars were filled by the lateral condensation technique (LC) and immersed in a 50-wt% aqueous silver nitrate solution at 37 degrees C (24 h). After longitudinal sectioning, epoxy resin replicas were made from the tooth specimens. Both the replicas and the specimens were prepared for scanning electron microscopy (SEM). The gaps were observed in the replicas. Apical microleakage was detected in the specimens by SEM/energy dispersive spectroscopy (SEM/EDS). The data were analyzed statistically using an Ordinal Logistic Regression model and Analysis of Correspondence (alpha=0.05). Results: Epiphany presented more regions containing gaps between dentin and sealer (p<0.05). There was correspondence between the presence of gaps and microleakage (p<0.05). Microleakage was similar among the root-filling materials (p>0.05). Conclusions: The resinous primer did not improve the sealing ability of AH Plus sealer and the presence of gaps had an effect on apical microleakage for all materials.
Resumo:
INTRODUCTION: Apical surgery has seen continuous development with regard to equipment and surgical technique. However, there is still a shortage of evidence-based information regarding healing determinants. The objective of this meta-analysis was to review clinical articles on apical surgery with root-end filling in order to assess potential prognostic factors. METHODS: An electronic search of PubMed and Cochrane databases was performed in 2008. Only studies with clearly defined healing criteria were included, and data for at least two categories per prognostic factor had to be reported. Prognostic factors were divided into patient-related, tooth-related, or treatment-related factors. The reported percentages of healed teeth ("the healed rate") were pooled per category. The statistical method of Mantel-Haenszel was applied to estimate the odds ratios and their 95% confidence intervals. RESULTS: With regard to tooth-related factors, the following categories were significantly associated with higher healed rates: cases without preoperative pain or signs, cases with good density of root canal filling, and cases with absence or size < or = 5 mm of periapical lesion. With regard to treatment-related factors, cases treated with the use of an endoscope tended to have higher healed rates than cases without the use of an endoscope. CONCLUSIONS: Although the clinician may be able to control treatment-related factors (by choosing a certain technique), patient- and tooth-related factors are usually beyond the surgeon's power. Nevertheless, patient- and tooth-related factors should be considered as important prognostic determinants when planning or weighing apical surgery against treatment alternatives.
Resumo:
Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.
Resumo:
Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.
Resumo:
Long-term measurements of CO2 flux can be obtained using the eddy covariance technique, but these datasets are affected by gaps which hinder the estimation of robust long-term means and annual ecosystem exchanges. We compare results obtained using three gap-fill techniques: multiple regression (MR), multiple imputation (MI), and artificial neural networks (ANNs), applied to a one-year dataset of hourly CO2 flux measurements collected in Lutjewad, over a flat agriculture area near the Wadden Sea dike in the north of the Netherlands. The dataset was separated in two subsets: a learning and a validation set. The performances of gap-filling techniques were analysed by calculating statistical criteria: coefficient of determination (R2), root mean square error (RMSE), mean absolute error (MAE), maximum absolute error (MaxAE), and mean square bias (MSB). The gap-fill accuracy is seasonally dependent, with better results in cold seasons. The highest accuracy is obtained using ANN technique which is also less sensitive to environmental/seasonal conditions. We argue that filling gaps directly on measured CO2 fluxes is more advantageous than the common method of filling gaps on calculated net ecosystem change, because ANN is an empirical method and smaller scatter is expected when gap filling is applied directly to measurements.
Resumo:
BACKGROUND AND PURPOSE Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.
Resumo:
O objetivo deste estudo foi comparar a fusibilidade de ligas de Co-Cr-Mo-W (Remanium 2000), Ni-Cr (Durabond) e Co-Cr-Mo (Vera-PDI), incluídas em revestimentos à base de fosfato, sílica ou utilizando uma técnica mista. Uma rede de nylon quadrada (10 X 10 mm) com 100 espaços abertos serviu de modelo para construção de padrões de cera, que foram incluídos com revestimento à base de sílica, revestimento fosfatado e técnica mista (camada de revestimento fosfatado com 2 mm de espessura + revestimento à base de sílica). Quarenta e cinco espécimes (5 para cada condição experimental) foram fundidos sob chama de gás-oxigênio e a seguir jateados com óxido de alumínio. O número de segmentos fundidos completos foi contado para obter uma percentagem designada como "valor de fusibilidade", representando a precisão da liga em reproduzir os detalhes do molde. A análise estatística por meio de ANOVA a dois critérios e teste Tukey mostrou que, comparando-se as ligas, a Remanium 2000 teve fusibilidade estaticamente semelhante (p>0,05) à da Vera PDI e inferior à da liga Durabond (p<0,05). Considerando os resultados da técnica mista, a liga Remanium 2000 teve menor valor de fusibilidade (p<0,05) que as ligas Durabond e Vera PDI, que apresentaram valores estatisticamente semelhantes entre si (p>0,05). Concluindo, a fusibilidade da liga de Co-Cr-Mo-W (Remanium 2000) foi comparável à da liga de Co-Cr (Vera PDI) e inferior à da liga de Ni-Cr alloy (Durabond). À exceção da liga Remanium 2000, a técnica de inclusão mista aumentou consideravelmente a capacidade das ligas testadas de reproduzir os detalhes do molde, quando comparada à técnica de inclusão em revestimento fosfatado. A técnica de inclusão mista representa uma alternativa para melhorar a fusibilidade de ligas de metais básicos sem afetar a qualidade superficial das peças metálicas.
Resumo:
O objetivo deste estudo foi comparar a fusibilidade de ligas de Co-Cr-Mo-W (Remanium 2000), Ni-Cr (Durabond) e Co-Cr-Mo (Vera-PDI), incluídas em revestimentos à base de fosfato, sílica ou utilizando uma técnica mista. Uma rede de nylon quadrada (10 X 10 mm) com 100 espaços abertos serviu de modelo para construção de padrões de cera, que foram incluídos com revestimento à base de sílica, revestimento fosfatado e técnica mista (camada de revestimento fosfatado com 2 mm de espessura + revestimento à base de sílica). Quarenta e cinco espécimes (5 para cada condição experimental) foram fundidos sob chama de gás-oxigênio e a seguir jateados com óxido de alumínio. O número de segmentos fundidos completos foi contado para obter uma percentagem designada como "valor de fusibilidade", representando a precisão da liga em reproduzir os detalhes do molde. A análise estatística por meio de ANOVA a dois critérios e teste Tukey mostrou que, comparando-se as ligas, a Remanium 2000 teve fusibilidade estaticamente semelhante (p>0,05) à da Vera PDI e inferior à da liga Durabond (p<0,05). Considerando os resultados da técnica mista, a liga Remanium 2000 teve menor valor de fusibilidade (p<0,05) que as ligas Durabond e Vera PDI, que apresentaram valores estatisticamente semelhantes entre si (p>0,05). Concluindo, a fusibilidade da liga de Co-Cr-Mo-W (Remanium 2000) foi comparável à da liga de Co-Cr (Vera PDI) e inferior à da liga de Ni-Cr alloy (Durabond). À exceção da liga Remanium 2000, a técnica de inclusão mista aumentou consideravelmente a capacidade das ligas testadas de reproduzir os detalhes do molde, quando comparada à técnica de inclusão em revestimento fosfatado. A técnica de inclusão mista representa uma alternativa para melhorar a fusibilidade de ligas de metais básicos sem afetar a qualidade superficial das peças metálicas.