1000 resultados para espectroscopia no infravermelho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infrared spectroscopy (IR spectroscopy) explores the infrared region of the electromagnetic spectrum. Like any other spectroscopic technique, it can be used to identify a compound or the composition of investigate a sample. Spectroscopy (IR) is a very important technique in qualitative chemical analysis, widely used in the chemistry of natural products, organic synthesis and transformations. In this work we study of the theoretical foundations of infrared spectroscopy, the different vibration modes, experimental techniques, and the identification and characterization of solids. Were studied as applications: their use in thermograph and remote sensing satellites

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work was developed with the objective of proposing a simple, fast and versatile methodological routine using near-infrared spectroscopy (NIR) combined with multivariate analysis for the determination of ash content, moisture, protein and total lipids present in the gray shrimp (Litopenaeus vannamei ) which is conventionally performed gravimetrically after ashing at 550 ° C gravimetrically after drying at 105 ° C for the determination of moisture gravimetrically after a Soxhlet extraction using volumetric and after digestion and distillation Kjedhal respectively. Was first collected the spectra of 63 samples processed boiled shrimp Litopenaeus vannamei species. Then, the determinations by conventional standard methods were carried out. The spectra centered average underwent multiplicative scattering correction of light, smoothing Saviztky-Golay 15 points and first derivative, eliminated the noisy region, the working range was from 1100,36 to 2502,37 nm. Thus, the PLS models for predicting ash showed R 0,9471; 0,1017 and RMSEP RMSEC 0,1548; Moisture R was 0,9241; 2,5483 and RMSEP RMSEC 4,1979; R protein to 0,9201; 1,9391 and RMSEP RMSEC 2,7066; for lipids R 0,8801; 0,2827 and RMSEP RMSEC 0,2329 So that the results showed that the relative errors found between the reference method and the NIR were small and satisfactory. These results are an excellent indication that you can use the NIR to these analyzes, which is quite advantageous, since conventional techniques are time consuming, they spend a lot of reagents and involve a number of professionals, which requires a reasonable runtime while after the validation of the methodology execution using NIR reduces all this time to a few minutes, saving reagents, time and without waste generation, and that this is a non-destructive technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biodiesel is a renewable fuel derived from vegetable oils or animal fats, which can be a total or partial substitute for diesel. Since 2005, this fuel was introduced in the Brazilian energy matrix through Law 11.097 that determines the percentage of biodiesel added to diesel oil as well as monitoring the insertion of this fuel in market. The National Agency of Petroleum, Natural Gas and Biofuels (ANP) establish the obligation of adding 7% (v/v) of biodiesel to diesel commercialized in the country, making crucial the analytical control of this content. Therefore, in this study were developed and validated methodologies based on the use of Mid Infrared Spectroscopy (MIR) and Multivariate Calibration by Partial Least Squares (PLS) to quantify the methyl and ethyl biodiesels content of cotton and jatropha in binary blends with diesel at concentration range from 1.00 to 30.00% (v/v), since this is the range specified in standard ABNT NBR 15568. The biodiesels were produced from two routes, using ethanol or methanol, and evaluated according to the parameters: oxidative stability, water content, kinematic viscosity and density, presenting results according to ANP Resolution No. 45/2014. The built PLS models were validated on the basis of ASTM E1655-05 for Infrared Spectroscopy and Multivariate Calibration and ABNT NBR 15568, with satisfactory results due to RMSEP (Root Mean Square Error of Prediction) values below 0.08% (<0.1%), correlation coefficients (R) above 0.9997 and the absence of systematic error (bias). Therefore, the methodologies developed can be a promising alternative in the quality control of this fuel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering the social and economic importance that the milk has, the objective of this study was to evaluate the incidence and quantifying antimicrobial residues in the food. The samples were collected in dairy industry of southwestern Paraná state and thus they were able to cover all ten municipalities in the region of Pato Branco. The work focused on the development of appropriate models for the identification and quantification of analytes: tetracycline, sulfamethazine, sulfadimethoxine, chloramphenicol and ampicillin, all antimicrobials with health interest. For the calibration procedure and validation of the models was used the Infrared Spectroscopy Fourier Transform associated with chemometric method based on Partial Least Squares regression (PLS - Partial Least Squares). To prepare a work solution antimicrobials, the five analytes of interest were used in increasing doses, namely tetracycline from 0 to 0.60 ppm, sulfamethazine 0 to 0.12 ppm, sulfadimethoxine 0 to 2.40 ppm chloramphenicol 0 1.20 ppm and ampicillin 0 to 1.80 ppm to perform the work with the interest in multiresidues analysis. The performance of the models constructed was evaluated through the figures of merit: mean square error of calibration and cross-validation, correlation coefficients and offset performance ratio. For the purposes of applicability in this work, it is considered that the models generated for Tetracycline, Sulfadimethoxine and Chloramphenicol were considered viable, with the greatest predictive power and efficiency, then were employed to evaluate the quality of raw milk from the region of Pato Branco . Among the analyzed samples by NIR, 70% were in conformity with sanitary legislation, and 5% of these samples had concentrations below the Maximum Residue permitted, and is also satisfactory. However 30% of the sample set showed unsatisfactory results when evaluating the contamination with antimicrobials residues, which is non conformity related to the presence of antimicrobial unauthorized use or concentrations above the permitted limits. With the development of this work can be said that laboratory tests in the food area, using infrared spectroscopy with multivariate calibration was also good, fast in analysis, reduced costs and with minimum generation of laboratory waste. Thus, the alternative method proposed meets the quality concerns and desired efficiency by industrial sectors and society in general.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The routine analysis for quantization of organic acids and sugars are generally slow methods that involve the use and preparation of several reagents, require trained professional, the availability of special equipment and is expensive. In this context, it has been increasing investment in research whose purpose is the development of substitutive methods to reference, which are faster, cheap and simple, and infrared spectroscopy have been highlighted in this regard. The present study developed multivariate calibration models for the simultaneous and quantitative determination of ascorbic acid, citric, malic and tartaric and sugars sucrose, glucose and fructose, and soluble solids in juices and fruit nectars and classification models for ACP. We used methods of spectroscopy in the near infrared (Near Infrared, NIR) in association with the method regression of partial least squares (PLS). Were used 42 samples between juices and fruit nectars commercially available in local shops. For the construction of the models were performed with reference analysis using high-performance liquid chromatography (HPLC) and refractometry for the analysis of soluble solids. Subsequently, the acquisition of the spectra was done in triplicate, in the spectral range 12500 to 4000 cm-1. The best models were applied to the quantification of analytes in study on natural juices and juice samples produced in the Paraná Southwest Region. The juices used in the application of the models also underwent physical and chemical analysis. Validation of chromatographic methodology has shown satisfactory results, since the external calibration curve obtained R-square value (R2) above 0.98 and coefficient of variation (%CV) for intermediate precision and repeatability below 8.83%. Through the Principal Component Analysis (PCA) was possible to separate samples of juices into two major groups, grape and apple and tangerine and orange, while for nectars groups separated guava and grape, and pineapple and apple. Different validation methods, and pre-processes that were used separately and in combination, were obtained with multivariate calibration models with average forecast square error (RMSEP) and cross validation (RMSECV) errors below 1.33 and 1.53 g.100 mL-1, respectively and R2 above 0.771, except for malic acid. The physicochemical analysis enabled the characterization of drinks, including the pH working range (variation of 2.83 to 5.79) and acidity within the parameters Regulation for each flavor. Regression models have demonstrated the possibility of determining both ascorbic acids, citric, malic and tartaric with successfully, besides sucrose, glucose and fructose by means of only a spectrum, suggesting that the models are economically viable for quality control and product standardization in the fruit juice and nectars processing industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (Mestrado em Tecnologia Nuclear)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o objetivo de diminuir a incidência das leveduras encapsulas em alginato se aglomerarem na segunda fermentação em garrafa e reduzir custos associados à sua eliminação, pretendeu-se utilizar a metodologia NIR para determinar a quantidade de cálcio no vinho. Foram quantificados outros minerais para avaliar hipotéticos antagonismos iónicos. Observou-se também que este controlo de qualidade poderá ser efetuado no mosto. Atualmente este controlo é realizado por metodologias de análise de referência bastante morosas como EAA. Contudo a metodologia NIR demonstrou ser uma boa alternativa no controlo dos parâ-metros de qualidade na produção de vinho espumante, permitindo a diminuição do tempo de análise e de resíduos. No desenvolvimento dos modelos matemáticos para a calibração do NIR utilizaram-se 79 vinhos brancos e 60 amostras de mosto. Foram desenvolvidos 11 modelos de calibração onde o coeficiente de correlação foi, em aproximadamente 58% dos casos, maior que 0,99; ABSTRACT: In order to reduce the incidence of alginate beads aggregation during the second fermentation in the bottle and to reduce costs associated with their disposal, it was used the NIR technology to quantify calcium content in the wine. Other minerals were also quantified in order to evaluate possible ionic antagonisms. Quality control is usually done in the base wine but it can also be evaluated in the must. Currently this control was carried out by reference analysis methodologies generally rather slow as AAS. However NIR proved to be a good alternative technique in the control of quality parameters of wine production, allowing the reduction of the analysis time and waste. In order to develop mathematical models for the calibration of NIR it was used 79 white wine samples and 60 must samples. Eleven calibration models have been developed, where the correlation coeffi-cient was, in approximately 58% of cases, greater than 0,99.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diversas técnicas analíticas podem ser usadas na determinação carbono do solo, predominando no Brasil métodos baseados na oxidação da matéria orgânica na presença de dicromato de potássio em meio ácido ou na análise elementar. O objetivo deste trabalho foi avaliar a viabilidade da estimativa do teor de carbono em solos da bacia do Acre por meio de espectroscopia NIR combinada com calibração por análise multivariada. Foram utilizadas 190 amostras de solos, coletadas em diversas localidades da bacia do Acre, para testar a espectroscopia NIR na determinação de teor de carbono no solo, comparativamente aos métodos de oxidação por dicromato em meio ácido e a análise elementar. Tomando-se como referência o método do analisador elementar, verifica-se que o método da oxidação recuperou, em média, 63,8 % do carbono determinado pelo método de referência. Sugere-se que para determinação do teor total de carbono solo a partir do método da oxidação seja adotado o coeficiente de 1,55 para corrigir os valores para o total de carbono do solo. Quanto ao uso da espectroscopia NIR, o modelo desenvolvido para análise de carbono de solos da bacia do Acre por espectroscopia NIR apresentou classificação boa segundo os valores de R e classificação excelente segundo os valores de RMSEC < RMSEP e RPD, tendo como referência o carbono determinado pelo método da análise elementar.