937 resultados para electronic appetite rating system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

2-Methylisoborneol (MIB) and geosmin (GSM) are sub products from algae decomposition and, depending on their concentration, can be toxic: otherwise, they give unpleasant taste and odor to water. For water treatment companies it is important to constantly monitor their presence in the distributed water and avoid further costumer complaints. Lower-cost and easy-to-read instrumentation would be very promising in this regard. In this study, we evaluate the potentiality of an electronic tongue (ET) system based on non-specific polymeric sensors and impedance measurements in monitoring MIB and GSM in water samples. Principal component analysis (PCA) applied to the generated data matrix indicated that this ET was capable to perform with remarkable reproducibility the discrimination of these two contaminants in either distilled or tap water, in concentrations as low as 25 ng L-1. Nonetheless, this analysis methodology was rather qualitative and laborious, and the outputs it provided were greatly subjective. Also, data analysis based on PCA severely restricts automation of the measuring system or its use by non-specialized operators. To circumvent these drawbacks, a fuzzy controller was designed to quantitatively perform sample classification while providing outputs in simpler data charts. For instance, the ET along with the referred fuzzy controller performed with a 100% hit rate the quantification of MIB and GSM samples in distilled and tap water. The hit rate could be read directly from the plot. The lower cost of these polymeric sensors allied to the especial features of the fuzzy controller (easiness on programming and numerical outputs) provided initial requirements for developing an automated ET system to monitor odorant species in water production and distribution. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographical references.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electronic database support system for strategic planning activities can be built by providing conceptual and system specific information. The design and development of this type of system center around the information needs of strategy planners. Data that supply information on the organization's internal and external environments must be originated, evaluated, collected, organized, managed, and analyzed. Strategy planners may use the resulting information to improve their decision making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Iowa Department of Transportation began preparation for the acquisition of an electronic document management system in 1996. The first phase was development of a strategic plan. The plan provided guidelines for defining the acquisition and implementation of a document management system to automate document handling and distribution. Phase 2 involved developing draft standards (document, indexing and technology) for planning and implementation of a document management system. These standards were to identify existing industry standards and determine which standards would best support the specific requirements of the Iowa Department of Transportation. During development of these standards, the decision was made to enlarge the scope of this effort from a document management system to a records management system (RMS). Phase .3 identified business processes that were to be further developed as pilot projects of a much larger agency-wide records management system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La caractérisation détaillée de vastes territoires pose un défi de taille et est souvent limitée par les ressources disponibles et le temps. Les travaux de cette maîtrise s’incorporent au projet ParaChute qui porte sur le développement d’une Méthode québécoise d’Évaluation du Danger des Chutes de Pierres (MEDCP) le long d’infrastructures linéaires. Pour optimiser l’utilisation des ressources et du temps, une méthode partiellement automatisée facilitant la planification des travaux de terrain a été développée. Elle se base principalement sur la modélisation des trajectoires de chutes de pierres 3D pour mieux cibler les falaises naturelles potentiellement problématiques. Des outils d’automatisation ont été développés afin de permettre la réalisation des modélisations sur de vastes territoires. Les secteurs où l’infrastructure a le plus de potentiel d’être atteinte par d’éventuelles chutes de pierres sont identifiés à partir des portions de l’infrastructure les plus traversées par les trajectoires simulées. La méthode a été appliquée le long du chemin de fer de la compagnie ArcelorMittal Infrastructures Canada. Le secteur couvert par l’étude débute à une dizaine de kilomètres au nord de Port-Cartier (Québec) et s’étend sur 260 km jusqu’au nord des monts Groulx. La topographie obtenue de levés LiDAR aéroportés est utilisée afin de modéliser les trajectoires en 3D à l’aide du logiciel Rockyfor3D. Dans ce mémoire, une approche facilitant la caractérisation des chutes de pierres le long d’un tracé linéaire est présentée. Des études de trajectoires préliminaires sont réalisées avant les travaux sur le terrain. Les informations tirées de ces modélisations permettent de cibler les secteurs potentiellement problématiques et d’éliminer ceux qui ne sont pas susceptibles de générer des chutes de pierres avec le potentiel d’atteindre les éléments à risque le long de l’infrastructure linéaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we describe a model of the human visual system (HVS) based on the wavelet transform. This model is largely based on a previously proposed model, but has a number of modifications that make it more amenable to potential integration into a wavelet based image compression scheme. These modifications include the use of a separable wavelet transform instead of the cortex transform, the application of a wavelet contrast sensitivity function (CSP), and a simplified definition of subband contrast that allows us to predict noise visibility directly from wavelet coefficients. Initially, we outline the luminance, frequency, and masking sensitivities of the HVS and discuss how these can be incorporated into the wavelet transform. We then outline a number of limitations of the wavelet transform as a model of the HVS, namely the lack of translational invariance and poor orientation sensitivity. In order to investigate the efficacy of this wavelet based model, a wavelet visible difference predictor (WVDP) is described. The WVDP is then used to predict visible differences between an original and compressed (or noisy) image. Results are presented to emphasize the limitations of commonly used measures of image quality and to demonstrate the performance of the WVDP, The paper concludes with suggestions on bow the WVDP can be used to determine a visually optimal quantization strategy for wavelet coefficients and produce a quantitative measure of image quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) irradiation on the removal of root surface smear layer of extracted human teeth and to compare its efficacy with that of citric acid, ethylenediamine tetra-acetic acid (EDTA), or a gel containing a mixture of tetracycline hydrochloride (HCl) and citric acid, using scanning electron microscopy (SEM). Thirty human dentin specimens were randomly divided into six groups: G1 (control group), irrigated with 10 ml of physiologic saline solution; G2, conditioned with 24% citric acid gel; G3, conditioned with 24% EDTA gel; G4, conditioned with a 50% citric acid and tetracycline gel; G5, irradiated with Er:YAG laser (47 mJ/10 Hz/5.8 J/cm(2)/pulse); G6, irradiated with Er:YAG laser (83 mJ/10 Hz/10.3 J/cm(2)/pulse). Electron micrographs were obtained and analyzed according to a rating system. Statistical analysis was conducted with Kruskal-Wallis and Mann-Whitney tests (P < 0.05). G1 was statistically different from all the other groups; no statistically significant differences were observed between the Er:YAG laser groups and those undergoing the other treatment modalities. When the two Er:YAG laser groups were compared, the fluency of G6 was statistically more effective in smear layer removal than the one used in G5 (Mann-Whitney test, P < 0.01). Root surfaces irradiated by Er:YAG laser had more irregular contours than those treated by chemical agents. It can be concluded that all treatment modalities were effective in smear layer removal. The results of our study suggest that the Er:YAG laser can be safely used to condition diseased root surfaces effectively. Furthermore, the effect of Er:YAG laser irradiation on root surfaces should be evaluated in vivo so that its potential to enhance the healing of periodontal tissues can be assessed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes a new test method for the assessment of the severity of environmental stress cracking of biomedical polyurethanes in a manner that minimizes the degree of subjectivity involved. The effect of applied strain and acetone pre-treatment on degradation of Pellethane 2363 80A and Pellethane 2363 55D polyurethanes under in vitro and in vivo conditions is studied. The results are presented using a magnification-weighted image rating system that allows the semi-quantitative rating of degradation based on distribution and severity of surface damage. Devices for applying controlled strain to both flat sheet and tubing samples are described. The new rating system consistently discriminated between. the effects of acetone pre-treatments, strain and exposure times in both in vitro and in vivo experiments. As expected, P80A underwent considerable stress cracking compared with P55D. P80A produced similar stress crack ratings in both in vivo and in vitro experiments, however P55D performed worse under in vitro conditions compared with in vivo. This result indicated that care must be taken when interpreting in vitro results in the absence of in vivo data. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objectivo desta Tese/Dissertação é conceber um sistema para a BOSCH Termotecnologia S.A., na qual exerço as funções de Engenheiro de Qualidade de Fornecedores de peças electrónicas, que permita testar funcionalmente dois tipos de PCBA (Printed Circuit Board Assembled) utilizados em dois modelos de esquentador estanque com denominação Celsius e Celsius Plus, produzidos nesta empresa para mercados de todo o Mundo. Os PCBA foram desenvolvidos internamente pelo departamento de ENG (Departamento de Desenvolvimento) e são actualmente peças de compra cujo fornecedor está localizado na China. Em primeiro lugar foi efectuado um estudo das necessidades da empresa relativamente aos projectos necessários para melhorar os processos de investigação de falhas e melhoria de Qualidade dos fornecedores de peças electrónicas, no contexto do departamento onde este projecto se insere. A conclusão chegada foi que existe uma grande necessidade de investigar avarias nas PCBA de compra do fornecedor asiático de forma rápida e precisa, de modo a que seja possível trabalhar mais activamente e rapidamente na melhoria de Qualidade do mesmo, melhorando, por exemplo, os seus processos produtivos. Em segundo lugar concebeu-se a solução a realizar. Optou-se por um conjunto hardware e software desenvolvido de raiz, que inclui um jig (gabarit anti-erro – Poke Yoke) dotado de agulhas para o teste FCT (Functional Circuit Test), um hardware de aquisição de dados analógicos e digitais adquirido para o projecto, um hardware de interface entre o PC (Personal Computer) e o hardware de aquisição de dados, e um software desenvolvido em LabVIEW versão 8.6 (Laboratory Virtual Instruments Engineering Workbench).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with investigating the groundwater quality for irrigation purpose, the vulnerability of the aquifer system to pollution and also the aquifer potential for sustainable water resources development in Kobo Valley development project. The groundwater quality is evaluated up on predicting the best possible distribution of hydrogeochemicals using geostatistical method and comparing them with the water quality guidelines given for the purpose of irrigation. The hydro geochemical parameters considered are SAR, EC, TDS, Cl-, Na+, Ca++, SO4 2- and HCO3 -. The spatial variability map reveals that these parameters falls under safe, moderate and severe or increasing problems. In order to present it clearly, the aggregated Water Quality Index (WQI) map is constructed using Weighted Arithmetic Mean method. It is found that Kobo-Gerbi sub basin is suffered from bad water quality for the irrigation purpose. Waja Golesha sub-basin has moderate and Hormat Golena is the better sub basin in terms of water quality. The groundwater vulnerability assessment of the study area is made using the GOD rating system. It is found that the whole area is experiencing moderate to high risk of vulnerability and it is a good warning for proper management of the resource. The high risks of vulnerability are noticed in Hormat Golena and Waja Golesha sub basins. The aquifer potential of the study area is obtained using weighted overlay analysis and 73.3% of the total area is a good site for future water well development. The rest 26.7% of the area is not considered as a good site for spotting groundwater wells. Most of this area fall under Kobo-Gerbi sub basin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The following work is a case study of overstock and stock-out problems at Volkswagen Autoeuropa (VWAE). It introduces the supply chain of Autoeuropa and specializes then on failures connected to inventory problems. Having a successful supply chain is important in a world where products become more and more similar as it can give to companies an edge over their competitors. The case shows three practices that VWAE uses to prevent and to overcome stock problems. Information was gathered by doing interviews with different managers, by analyzing the company’s key processes and by literature research related to the topics of supply chain management and flexibility in the supply chain. Three practices were further investigated: the use of alternative parts, support of the supplier and a rating system of suppliers. In the question section of this work the importance of flexibility and Supplier Relationship Management (SRM) when connected to supply chain management are explained. The described different practices are numerically analyzed and it is concluded that each practice brings both cost savings and the possibility of achieving target numbers to the company, showing the company’s flexibility to react to supply chain disturbances. Because of confidentiality reasons, persons in the case are fictionalized and numbers are wherever possible equalized to 100 in order to display true proportions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Ireland the average energy cost for a household in 2006 was estimated to be €1,767, an increase of 4% on 2005 figures. With the state o f the current economic climate, home owners are beginning to realise the potential of energy efficient construction methods. The Passive House Standard offers a cost efficient and sustainable construction solution compared to the Traditional Irish construction methods. This report focuses on the Cost comparison between Passive House construction and traditional construction methods. The report also focuses on barriers that are slowing market penetration of the Passive House standard in the Irish Market. It also identifies potential energy savings that passive house occupants would benefit from. The report also highlights professional opinions on the future development o f the Passive House Standard in Ireland. The conclusions of this report are that the Passive House Standard is a more financially suitable construction solution compared to that o f a traditional dwelling complying with the Irish Building Regulations. The report also concludes that the Passive House Standard won’t be introduced as an Irish Building Regulation in the future but that it will have a big impact on future building regulations. The hypothesis o f this report is supported by data obtained from a literature review, qualitative data analysis and a case study. The report recommends that in order for the Passive House Standard to penetrate further into the Irish construction market, various barriers must be rectified. Local manufactures must start producing suitable components that suit the Passive House specification. The Building Energy Rating system must be altered in order for the Passive House to achieve its potential BER rating.