998 resultados para electrochemical noise


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wear and corrosion of metal-on-metal hip replacements results in wear debris and metal-ion release in vivo, which may subsequently cause pain and hypersensitivity for patients. Retrieved metal-on-metal hip replacements have revealed that two-body sliding wear and three-body abrasive wear are the predominant wear mechanisms. However, there is a lack of understanding of the combined effects of wear/corrosion, especially the effect of abrasion-corrosion.

This study investigates the sliding-corrosion and abrasion-corrosion performance of a cast CoCrMo alloy in simulated hip joint environments using a microabrasion rig integrated with an electrochemical cell. Tests have been conducted in 0.9% NaCl, phosphate buffered saline solution, 25% and 50% bovine serum solutions with 0 or 1 g cm(-3) SiC at 37 degrees C. Experimental results reveal that under abrasion-corrosion test conditions, the presence of proteins increased the total specific wear rate. Conversely, electrochemical noise measurements indicated that the average anodic current levels were appreciably lower for the proteinaceous solutions when compared with the inorganic solutions. A severely deformed nanocrystalline layer was identified immediately below the worn surface for both proteinaceous and inorganic solutions. The layer is formed by a recrystallisation process and/or a strain-induced phase transformation that occurs during microabrasion-corrosion. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel electrochemically integrated multi-electrode array namely the wire beam electrode(WBE) in combination with noise signatures analysis has been designed to monitor pittingcorrosion of one of the best corrosion resistance ferrous alloys, stainless steel type 316L.From the direct correlation of electrochemical potential noise signatures and galvanic currentdistribution maps during pitting corrosion processes, two characteristic noise patterns wereobserved prior to stable pit formation: (i) the characteristic ‘peak’ of rapid potential transient,towards less negative direction, followed by recovery (termed noise signature I) was found tocorrelate with the disappearance of unstable anode; (ii) the characteristic noise pattern ofquick potential changes towards less negative direction followed by no recovery (termed noisesignature II) was found to correspond with the massive disappearance of minor anodes leadingto formation of highly localized major anodes in the galvanic current distribution maps.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Parameters extracted from the wire beam electrode (WBE) galvanic current maps have been used in conjunction with electrochemical noise patterns to directly quantify the degree of localised corrosion inhibition provided by inhibitors and to understand the mechanism of localised corrosion inhibition. The behaviour of two traditional localised corrosion inhibitors has been assessed by their effects on the maximum anodic current density (imax), total anodic current density (itot), the number of anodic sites (Na) and the localised corrosion intensity index (LCII). Typical experiments are presented to illustrate the application of these parameters in providing useful information on the efficiency and mechanism of localised corrosion inhibition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Organic coatings have been used in conjunction with cathodic protection as the most economical method of corrosion protection by the oil and gas pipeline industry. In a bid to prolong the life of the pipelines, the degradation and failure of pipeline coatings under the effects of major influencing factors including mechanical stress, the environmental corrosivity and cathodic protection have been extensively investigated over the past decades. This paper provides an overview of recent research for understanding coating degradation under the effect of these factors, either individually or in combination. Electrochemical impedance spectroscopy remains the primary and the most commonly used technique of studying the degradation of organic coatings, although there have been attempts to use other techniques such as electrochemical polarization (both dynamic and static), electrochemical noise, Scanning Kelvin Probe, Fourier Transform Infrared Spectroscopy, Differential Scanning Calorimetry and Dynamic Mechanical Analyser. Major knowledge and technological gaps in the investigation of the combined effects of mechanical stress, environmental corrosivity and cathodic protection on coating degradation have been identified.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atom probe tomography (APT) has been used to investigate the surface and sub-surface microstructures of aluminum alloy 2024 (AA2024) in the T3 condition (solution heat treated, cold worked, and naturally aged to a substantially stable condition). This study revealed surface Cu enrichment on the alloy matrix, local chemical structure around a dispersoid Al20Mn3Cu2 particle including a Cu-rich particle and S-phase particle on its external surface. Moreover, there was a significant level of hydrogen within the dispersoid, indicating that it is a hydrogen sink. These observations of the nanoscale structure around the dispersoid particle have considerable implications for understanding both corrosion and hydrogen embrittlement in high-strength aluminum alloys.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A number of factors relating to various methods of repair for chloride initiated corrosion damage of reinforced concrete have been studied. A novel methodology has been developed to facilitate the measurement of macro and micro-cell corrosion rates for steel electrodes embedded in mortar prisms containing a chloride gradient. The galvanic bar specimen comprised electrically isolatable segmental mild steel electrodes and was constructed such that macro-cell corrosion currents were determinable for a number of electrode combinations. From this, the conditions giving rise to an incipient anode were established. The influence of several reinforcement and substrate primer systems upon macro-cell corrosion, arising from an incipient anode, within a patch repair have been investigated. Measurements of electrochemical noise were made in order to investigate the suitability of the technique as an on-site means of assessing corrosion activity within chloride contaminated reinforced concrete. For this purpose the standard deviation of potential noise was compared to macro-cell galvanic current data and micro-cell corrosion intensity determined by linear polarisation. Hydroxyl ion pore solution analyses were carried out on mortar taken from cathodically protected specimens. These specimens, containing sodium chloride, were cathodically protected over a range of polarisation potentials. Measurement of the hydroxyl ion concentrations were made in order to examine the possibility of alkali-silica reactions initiated by cathodic protection of reinfored concrete. A range of mortars containing a variety of generic type additives were examined in order to establish their resistances to chloride ion diffusion. The effect of surfactant addition rate was investigated within a cement paste containing various dosages of naphthalene sulphonate.