979 resultados para crestal bone levels


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIM: To compare the 10-year peri-implant bone loss (BL) rate in periodontally compromised (PCP) and periodontally healthy patients (PHP) around two different implant systems supporting single-unit crowns. MATERIALS AND METHODS: In this retrospective, controlled study, the mean BL (mBL) rate around dental implants placed in four groups of 20 non-smokers was evaluated after a follow-up of 10 years. Two groups of patients treated for periodontitis (PCP) and two groups of PHP were created. For each category (PCP and PHP), two different types of implant had been selected. The mBL was calculated by subtracting the radiographic bone levels at the time of crown cementation from the bone levels at the 10-year follow-up. RESULTS: The mean age, mean full-mouth plaque and full-mouth bleeding scores and implant location were similar between the four groups. Implant survival rates ranged between 85% and 95%, without statistically significant differences (P>0.05) between groups. For both implant systems, PCP showed statistically significantly higher mBL rates and number of sites with BL> or =3 mm compared with PHP (P<0.0001). CONCLUSIONS: After 10 years, implants in PCP yielded lower survival rates and higher mean marginal BL rates compared with those of implants placed in PHP. These results were independent of the implant system used or the healing modality applied.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIM: The aim of this study was to compare the clinical outcomes after 2 years with bone level implants placed to restore a single missing teeth that needed simultaneous augmentation and were treated with a transmucosal or submerged approach. METHODS: This study analyzed a subset of patients included in an ongoing prospective multicenter randomized clinical trial (RCT) involving12 centers where patients were to be followed-up to 5 years after loading. Of the 120 implants that were placed in the original study, and randomly assigned to submerged or non-submerged healing, 52 needed simultaneous augmentation (28 women patients and 24 men patients, between 23 and 78 years of age). Twenty-seven of them received implants with submerged healing (AuS), while in 25 patients the implants were inserted with a non-submerged protocol (AuNS). At the 2-year follow-up visit, radiographic crestal bone level changes were recorded as well as soft tissue parameters included Pocket probing depth (PPD), bleeding on probing (BoP) and clinical attachment level (CAL) at teeth adjacent to the implant site. RESULTS: After 2 years a small amount of bone resorption was found in both groups (0.37 ± 0.49 mm in the AuS group and 0.54 ± 0.76 in the AuNS group; P < 0.001). There was no statistically significant difference between AuS Group and AuNS group for PPD (2.5 vs. 2.4 mm), BOP (BOP + sites: 8.8% vs. 11.5%) and CAL (2.8 vs. 2.4 mm) at the 2-year follow-up visit. CONCLUSIONS: When a single implant is placed in the aesthetic zone in conjunction with bone augmentation for a moderate peri-implant defect, submerged and transmucosal healing determine similar outcome, hence there is no need to submerge an implant in this given clinical situation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Lateral ridge augmentations are traditionally performed using autogenous bone grafts to support membranes for guided bone regeneration (GBR). The bone-harvesting procedure, however, is accompanied by considerable patient morbidity. AIM: The aim of the present study was to test whether or not resorbable membranes and bone substitutes will lead to successful horizontal ridge augmentation allowing implant installation under standard conditions. MATERIAL AND METHODS: Twelve patients in need of implant therapy participated in this study. They revealed bone deficits in the areas intended for implant placement. Soft tissue flaps were carefully raised and blocks or particles of deproteinized bovine bone mineral (DBBM) (Bio-Oss) were placed in the defect area. A collagenous membrane (Bio-Gide) was applied to cover the DBBM and was fixed to the surrounding bone using poly-lactic acid pins. The flaps were sutured to allow for healing by primary intention. RESULTS: All sites in the 12 patients healed uneventfully. No flap dehiscences and no exposures of membranes were observed. Nine to 10 months following augmentation surgery, flaps were raised in order to visualize the outcomes of the augmentation. An integration of the DBBM particles into the newly formed bone was consistently observed. Merely on the surface of the new bone, some pieces of the grafting material were only partly integrated into bone. However, these were not encapsulated by connective tissue but rather anchored into the newly regenerated bone. In all of the cases, but one, the bone volume following regeneration was adequate to place implants in a prosthetically ideal position and according to the standard protocol with complete bone coverage of the surface intended for osseointegration. Before the regenerative procedure, the average crestal bone width was 3.2 mm and to 6.9 mm at the time of implant placement. This difference was statistically significant (P<0.05, Wilcoxon's matched pairs signed-rank test). CONCLUSION: After a healing period of 9-10 months, the combination of DBBM and a collagen membrane is an effective treatment option for horizontal bone augmentation before implant placement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: The concept of early implant placement is a treatment option in postextraction sites of single teeth in the anterior maxilla. Implant placement is performed after a soft tissue healing period of 4 to 8 weeks. Implant placement in a correct three-dimensional position is combined with a simultaneous guided bone regeneration procedure to rebuild esthetic facial hard and soft tissue contours. METHODS: In this retrospective, cross-sectional study, 45 patients with an implant-borne single crown in function for 2 to 4 years were recalled for examination. Clinical and radiologic parameters, routinely used in implant studies, were assessed. RESULTS: All 45 implants were clinically successful according to strict success criteria. The implants demonstrated ankylotic stability without signs of a peri-implant infection. The peri-implant soft tissues were clinically healthy as indicated by low mean plaque (0.42) and sulcus bleeding index (0.51) values. None of the implants revealed a mucosal recession on the facial aspect as confirmed by a clearly submucosal position of all implant shoulders. The mean distance from the mucosal margin to the implant shoulder was -1.93 mm on the facial aspect. The periapical radiographs showed stable peri-implant bone levels, with a mean distance between the implant shoulder and the first bone-implant contact of 2.18 mm. CONCLUSIONS: This retrospective study demonstrated successful treatment outcomes for all 45 implants examined. The mid-term follow-up of 2 to 4 years also showed that the risk for mucosal recession was low with this treatment concept. Prospective clinical studies are required to confirm these encouraging results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Early implant placement is one of the treatment options in postextraction sites in the anterior maxilla. Implant placement is performed after a soft tissue healing period of 4 to 8 weeks. Implant placement is combined with a simultaneous guided bone regeneration (GBR) procedure to rebuild esthetic facial hard and soft tissue contours. METHODS: In this prospective case-series study, 20 consecutive patients treated with an implant-borne single crown were prospectively followed for 12 months. Clinical, radiologic, and esthetic parameters were recorded to assess treatment outcomes. RESULTS: At the 12-month examination, all 20 implants were successfully integrated, demonstrating ankylotic stability and healthy peri-implant soft tissues as documented by standard parameters. The esthetic outcomes assessed by a pink esthetic score (PES) and a white esthetic score (WES) demonstrated pleasing results overall. The WES values were slightly superior to the PES values. The periapical radiographs showed minimal crestal bone loss around the used bone level implants, with mean bone loss of 0.18 mm at 12 months. Only one implant showed >0.5 mm bone loss, combined with minor mucosal recession of 0.5 to 1.0 mm. CONCLUSIONS: This prospective case series study evaluating the concept of early implant placement demonstrated successful tissue integration for all 20 implants. The short-term follow-up of 12 months revealed pleasing esthetic outcomes overall, as assessed by objective parameters. The risk for mucosal recession was low; only one patient showed minor recession of the facial mucosa. These encouraging results need to be confirmed with 3- and 5-year follow-up examinations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the suitability of a minipig model for the study of bone healing and osseointegration of dental implants following bone splitting and expansion of narrow ridges. MATERIAL AND METHODS In four minipigs, the mandibular premolars and first molars were extracted together with removal of the buccal bone plate. Three months later, ridge splitting and expansion was performed with simultaneous placement of three titanium implants per quadrant. On one side of the mandible, the expanded bone gap between the implants was filled with an alloplastic biphasic calcium phosphate (BCP) material, while the gap on the other side was left unfilled. A barrier membrane was placed in half of the quadrants. After a healing period of 6 weeks, the animals were sacrificed for histological evaluation. RESULTS In all groups, no bone fractures occurred, no implants were lost, all 24 implants were osseointegrated, and the gap created by bone splitting was filled with new bone, irrespective of whether BCP or a barrier membrane was used. Slight exposure of five implants was observed, but did not lead to implant loss. The level of the most coronal bone-to-implant contact varied without being dependent on the use of BCP or a barrier membrane. In all groups, the BCP particles were not present deep in the bone-filled gap. However, BCP particles were seen at the crestal bone margin, where they were partly integrated in the new bone. CONCLUSIONS This new minipig model holds great promise for studying experimental ridge splitting/expansion. However, efforts must be undertaken to reduce implant exposure and buccal bone resorption.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE To evaluate and compare crestal bone level changes and peri-implant status of implant-supported reconstructions in edentulous and partially dentate patients after a minimum of 5 years of loading. MATERIALS AND METHODS All patients who received a self-tapping implant with a microstructured surface during the years 2003 and 2004 at the Department of Prosthodontics, University of Bern, were included in this study. The implant restorations comprised fixed and removable prostheses for partially and completely edentulous patients. Radiographs were taken immediately after surgery, at impression making, and 1 and 5 years after loading. Crestal bone level (BIC) was measured from the implant shoulder to the first bone contact, and changes were calculated over time (ΔBIC). The associations between pocket depth, bleeding on probing (BOP), and ΔBIC were assessed. RESULTS Sixty-one implants were placed in 20 patients (mean age, 62 ± 7 years). At the 5-year follow-up, 19 patients with 58 implants were available. Implant survival was 98.4% (one early failure; one patient died). The average ΔBIC between surgery and 5-year follow-up was 1.5 ± 0.9 mm and 1.1 ± 0.6 mm for edentulous and partially dentate patients, respectively. Most bone resorption (50%, 0.7 mm) occurred during the first 3 months (osseointegration) and within the first year of loading (21%, 0.3 mm). Mean annual bone loss during the 5 years of loading was < 0.12 mm. Mean pocket depth was 2.6 ± 0.7 mm. Seventeen percent of the implant sites displayed BOP; the frequency was significantly higher in women. None of the variables were significantly associated with crestal bone loss. CONCLUSION Crestal bone loss after 5 years was within the normal range, without a significant difference between edentulous and partially dentate patients. In the short term, this implant system can be used successfully for various prosthetic indications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of the periosteum in preserving the buccal bone after ridge splitting and expansion with simultaneous implant placement. MATERIAL AND METHODS In 12 miniature pigs, the mandibular premolars and first molars were removed together with the interdental bone septa and the buccal bone. Three months later, ridge splitting and expansion of the buccal plate was performed with simultaneous placement of two titanium implants per quadrant. Access by a mucosal flap (MF) was prepared on test sides, while a mucoperiosteal flap (MPF) with complete denudation of the buccal bone was increased on control sides. After healing periods of six and 12 weeks, the animals were sacrificed for histologic and histometric evaluation. RESULTS In the MF group, all 16 implants were osseointegrated, while in the MPF group, four of 16 implants were lost. Noticeable differences of bone levels on the implant surface and of the bone crest (BC) were found between the MF and the MPF group. Buccally after 6 weeks, the median distance between the implant shoulder (IS) and the coronal-most bone on the implant (cBIC) was for the MF group -1.42 ± 0.42 mm and for the MPF group -4.80 ± 2.72 mm (P = 0.15). The median distance between the IS and the buccal BC was -1.24 ± 0.51 mm and -2.78 ± 1.98 mm (P = 0.12) for the MF and MPF group, respectively. After 12 weeks, median IS-cBIC was -2.12 ± 0.84 mm for MF and -7.19 mm for MPF, while IS-BC was -2.08 ± 0.79 mm for MF and -5.96 mm for MPF. After 6 weeks, the median buccal bone thickness for MF and MPF was 0.01 and 0 mm (P < 0.001) at IS, 1.48 ± 0.97 mm and 0 ± 0.77 mm (P = 0.07) at 2 mm apical to IS, and 2.12 ± 1.19 mm and 1.72 ± 01.50 mm (P = 0.86) at 4 mm apical to IS, respectively. After 12 weeks, buccal bone thickness in the MF group was 0 mm at IS, 0.21 mm at 2 mm apical to IS, and 2.56 mm at 4 mm apical to IS, whereas complete loss of buccal bone was measured from IS to 4 mm apical to IS for the MPF group. CONCLUSIONS In this ridge expansion model in miniature pigs, buccal bone volume was significantly better preserved when the periosteum remained attached to the bone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION Apical surgery is an important treatment option for teeth with post-treatment periodontitis. Although apical surgery involves root-end resection, no morphometric data are yet available about root-end resection and its impact on the root-to-crown ratio (RCR). The present study assessed the length of apicectomy and calculated the loss of root length and changes of RCR after apical surgery. METHODS In a prospective clinical study, cone-beam computed tomography scans were taken preoperatively and postoperatively. From these images, the crown and root lengths of 61 roots (54 teeth in 47 patients) were measured before and after apical surgery. Data were collected relative to the cementoenamel junction (CEJ) as well as to the crestal bone level (CBL). One observer took all measurements twice (to calculate the intraobserver variability), and the means were used for further analysis. The following parameters were assessed for all treated teeth as well as for specific tooth groups: length of root-end resection and percentage change of root length, preoperative and postoperative RCRs, and percentage change of RCR after apical surgery. RESULTS The mean length of root-end resection was 3.58 ± 1.43 mm (relative to the CBL). This amounted to a loss of 33.2% of clinical and 26% of anatomic root length. There was an overall significant difference between the tooth groups (P < .05). There was also a statistically significant difference comparing mandibular and maxillary teeth (P < .05), but not for incisors/canines versus premolars/molars (P = .125). The mean preoperative and postoperative RCRs (relative to CEJ) were 1.83 and 1.35, respectively (P < .001). With regard to the CBL reference, the mean preoperative and postoperative RCRs were 1.08 and 0.71 (CBL), respectively (P < .001). The calculated changes of RCR after apical surgery were 24.8% relative to CEJ and 33.3% relative to CBL (P < .001). Across the different tooth groups, the mean RCR was not significantly different (P = .244 for CEJ and 0.114 for CBL). CONCLUSIONS This CBCT-based study demonstrated that the RCR is significantly changed after root-end resection in apical surgery irrespective of the clinical (CBL) or anatomic (CEJ) reference levels. The lowest, and thus clinically most critical, postoperative RCR was observed in maxillary incisors. Future clinical studies need to show the impact of resection length and RCR changes on the outcome of apical surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Stability of pen-implant crestal bone plays a relevant role relative to the presence or absence of interdental papilla. Several factors can contribute to the crestal bone resorption observed around two-piece implants, such as the presence of a microgap at the level of the implant abutment junction, the type of connection between implant and prosthetic components, the implant positioning relative to the alveolar crest, and the interimplant distance. Subcrestal positioning of dental implants has been proposed to decrease the risk of exposure of the metal of the top of the implant or of the abutment margin, and to get enough space in a vertical dimension to create a harmoniously esthetic emergence profile. Methods: The present retrospective histologic study was performed to evaluate dental implants retrieved from human jaws that had been inserted in an equicrestal or subcrestal position. A total of nine implants were evaluated: five of these had been inserted in an equicrestal position, whereas the other four had been positioned subcrestally (1 to 3 mm). Results: In all subcrestally placed implants, preexisting and newly formed bone was found over the implant shoulder. In the equicrestal implants, crestal bone resorption (0.5 to 1.5 mm) was present around all implants. Conclusion: The subcrestal position of the implants resulted in bone located above the implant shoulder. J Periodontol 2011;82:708-715.