943 resultados para continuous performance


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A control algorithm is presented that addresses the stability issues inherent to the operation of monolithic mode-locked laser diodes. It enables a continuous pulse duration tuning without any onset of Q-switching instabilities. A demonstration of the algorithm performance is presented for two radically different laser diode geometries and continuous pulse duration tuning between 0.5 ps to 2.2 ps and 1.2 ps to 10.2 ps is achieved. With practical applications in mind, this algorithm also facilitates control over performance parameters such as output power and wavelength during pulse duration tuning. The developed algorithm enables the user to harness the operational flexibility from such a laser with 'push-button' simplicity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper concerns the development and validation (using an oil/water system) of a finite volume computer model of the continuous casting process for steel flat products. The emphasis is on hydrodynamic aspects and in particular the dynamic behaviour of the metal/slag interface. Instability and wave action encourage the entrainment of inclusions into the melt affecting product quality. To track the interface between oil and water a new implicit algorithm was developed, called the Counter Diffusion Method. To prevent excessive damping, a time-filtered version of the k-e model, was found necessary, with appropriate density stratification terms representing interface turbulence damping.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Next generation Global Navigation Satellite System (GNSS) receivers will operate in multiple navigation bands. An efficient way to achieve this with lower power and cost is to employ BandPass Sampling (BPS); nevertheless, the sampling operation injects large amounts of jitter noise, which degrades the performance of the receiver. Continuous–Time (CT) Delta–Sigma (ΔΣ) modulators are capable of suppressing this noise but the impact of clock jitter at the output of the Digital– to–Analog Converter (DAC) in the feedback path of the modulator should be taken into account. This paper presents an analytical approach for describing clock jitter in GNSS receivers when a CT–ΔΣ modulator is utilized for Analog–to–Digital Conversion (ADC). The validity of the presented approach is verified through time–domain simulations using a behavioural model of the fourth–order CT–ΔΣ modulator with 1–bit NRZ DAC feedback pulse.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper reports on a Field Programmable Gate Array (FPGA) implementation as well as prototyping for real-time testing of a low complexity high efficiency decimation filter processor which is deployed in conjunction with a custom built low-power jitter insensitive Continuous Time (CT) Sigma-Delta (Σ-Δ) Modulator to measure and assess its performance. The CT Σ-Δ modulator/decimation filter cascade can be used in integrated all-digital microphone interfaces for a variety of applications including mobile phone handsets, wireless handsets as well as other applications requiring all-digital microphones. The work reported here concentrates on the design and implementation as well as prototyping on a Xilinx Spartan 3 FPGA development system and real-time testing of the decimation processing part deploying All-Pass based structures to process the bit stream coming from CT Σ-Δ modulator hence measuring in real-time and fully assessing the modulator's performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Research has shown a consistent correlation between efficacy and sport performance (Moritz, et aI., 2000). This relationship has been shown to be dynamic and reciprocal over seasons (e.g., Myers, Payment, et aI., 2004), within games (e.g., Butt, et aI., 2003), and across trials (e.g., Feltz, 1982). The purpose of the present study was to examine selfefficacy and performance simultaneously within one continuous routine. Forty-seven undergraduate students performed a gymnastic sequence while using an efficacy measure. Results indicated that the efficacy-performance relationship was not reciprocal; previous performance was a significant predictor of subsequent performance (p < .01; f3s ranged from .44 to .67). Results further revealed significant differences in efficacy beliefs between groups with high and low levels of performance [F (1,571) = 7.16,p < .01]. Findings suggest that high levels of performance within a continuous physical activity task result in higher performance scores and higher efficacy beliefs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The self-efficacy-performance relationship in continuous sport tasks has been shown to be significantly reciprocal yet unequal with stronger influences in the performance-to-self-efficacy pathway rather than self-efficacy-to-performance pathway (e.g., LaForge-MacKenzie & Sullivan, 2014b). Bandura (2012) suggested that sociocognitive variables may influence this relationship. Attention as a sociocognitve factor may bias the processing of performance and self-efficacy information (Bandura, 1982, 1997; Bandura & Jourden, 1991). As confidence and attention are important aspects of peak running performance (Brewer, Van Raalte, Linder, & VanRaalte, 1991), the primary purpose of the present study was to examine the self-efficacy-performance relationship under three conditions of attentional focus. The secondary purpose was to examine self-efficacy and performance as separate constructs under the same conditions of attention. Participants ran continuously for one kilometer in one of three randomly assigned attentional focus conditions: internal-focus (n = 51), external-focus (n = 50), and control (n = 49). Self-efficacy was assessed using a one-item measure every 200 meters. Path analyses examining the primary objective revealed significant self-efficacy-to-performance pathways in all conditions: external-focus (p < .05, βs ranging from -.17 to -.32), internal-focus (p < .05, βs ranging from -.26 to -.36), and control (p < .05, βs ranging from -.29 to -.42). Significant reciprocal relationships were absent in all conditions. ANOVAs examining the secondary objectives found significantly faster performance in the control condition at the start (F (2, 147) = 3.86, p < .05) and end of the task (F (2, 147) = 3.56, p < .05). Self-efficacy was significantly higher in the internal-focus condition at the end of the task (Self-Efficacy 4 (F (2, 147) = 3.21, p < .05) and Self-Efficacy 5 (F (2, 147) = 4.74, p < .05). In contrast to previous within-trial research (e.g., LaForge-MacKenzie & Sullivan, 2014b) self-efficacy-to-performance effects were more significant and robust than performance-to-self-efficacy effects. These results provided support for Bandura’s (2012) suggestion that sociocognitive factors may have the ability to alter the causal structure of the self-efficacy-performance relationship, proposing complexities in the self-efficacy-performance relationship (Sitzmann &Yeo, 2013). Results were discussed from both theoretical and applied perspectives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to assess the sward canopy structure of Brachiaria brizantha cv. Marandu pastures maintained in three grazing intensities under continuous stocking system during the rainy season, along with the behavior and performance of grazing beef heifers supplemented with mineral salt or an energy/protein supplement. Three levels of forage allowance were assessed: 2.0, 2.5 and 3.0 kg of forage/kg of live weight, combined with two supplements (ad libitum mineral salt, and an energy/protein supplement at 0.3% of live weight/day, supplied daily). The experiment was designed as a randomized block study with two replications. The supplements did not influence the variables related to the canopy structure. Canopy height was greater at higher forage allowances during the late summer and early fall. Similarly, the stem mass was greater in pastures with higher forage allowances. Animals fed protein supplement spent less time grazing than animals supplemented with mineral salt. Stocking rate was higher in pastures with lower forage allowance levels, which increased the live weight gain per grazing area. Daily weight gain did not vary according to the forage allowance levels. The use of an energy/protein supplement did not affect the stocking rate; however, it increased individual live weight gain and live weight gain per grazing area compared with mineral salt supplementation. The use of energy/protein supplements is an efficient alternative to enhance animal performance and production under grazing systems during the rainy season

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of preferred and nonpreferred music on exercise distance, Heart Rate (HR), and Rating of Perceived Exertion (RPE) during continuous cycling exercise performed at high intensity Fifteen participants performed five test sessions During two sessions, they cycled with fixed workload on ergometer to determine the Critical Power (Cl') intensity Then, they performed three more sessions cycling at CP intensity listening to Preferred Music, listening to Nonpreferred Music, and No Music The HR responses in the exercise sessions did not differ among all conditions However, the RPE was higher for Nonpreferred Music than in the other conditions The performance under Preferred Music (9 8 +/- 4 6km) was greater than under Nonpreferred Music (7 1 +/- 3 5km) conditions Therefore, listening to Preferred Music during continuous cycling exercise at high intensity can Increase the exercise distance, and individuals listening to Nonpreferred Music can perceive more discomfort caused by the exercise

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A viscometric affinity sensor has been developed to measure the interstitial glucose concentration continuously. In a pilot clinical study its performance was assessed under conditions close to everyday life. Additionally, different insertion sites were tested for their suitability to apply subcutaneous glucose sensors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.