956 resultados para concentration time
Resumo:
Following a malicious or accidental atmospheric release in an outdoor environment it is essential for first responders to ensure safety by identifying areas where human life may be in danger. For this to happen quickly, reliable information is needed on the source strength and location, and the type of chemical agent released. We present here an inverse modelling technique that estimates the source strength and location of such a release, together with the uncertainty in those estimates, using a limited number of measurements of concentration from a network of chemical sensors considering a single, steady, ground-level source. The technique is evaluated using data from a set of dispersion experiments conducted in a meteorological wind tunnel, where simultaneous measurements of concentration time series were obtained in the plume from a ground-level point-source emission of a passive tracer. In particular, we analyze the response to the number of sensors deployed and their arrangement, and to sampling and model errors. We find that the inverse algorithm can generate acceptable estimates of the source characteristics with as few as four sensors, providing these are well-placed and that the sampling error is controlled. Configurations with at least three sensors in a profile across the plume were found to be superior to other arrangements examined. Analysis of the influence of sampling error due to the use of short averaging times showed that the uncertainty in the source estimates grew as the sampling time decreased. This demonstrated that averaging times greater than about 5min (full scale time) lead to acceptable accuracy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.
Resumo:
Um método envolvendo a pré-concentração e redissolução anódica em condições de voltametria de pulso diferencial empregando um eletrodo de pasta de carbono modificado (EPCM) com uma resina de troca iônica Amberlite IR120 foi proposto para a determinação de íons chumbo em álcool combustível. O procedimento é baseado em um pico de oxidação do analito observado em -0,53 V(vs. Ag/AgCl) em solução de HCl. As melhores condições experimentais encontradas foram: 5% (m/m) da Amberlite IR120 para a construção do eletrodo, solução de HCl 0,1 mol L-1, velocidade de varredura de 10 mVs-1, tempo de pré-concentração de 15 min e amplitude de pulso de 100 mV. Utilizando essas condições, o EPCM apresentou uma resposta linear entre a corrente de pico anódica e a concentração de íons chumbo para o intervalo entre 9,9 x 10-9 e 1,2 x 10-6 mol L-1 e um limite de detecção de 7,2 x 10-9 mol L-1. Valores de recuperação entre 96 % e 102 % foram encontrados para amostras de álcool combustível enriquecidas com Pb2+ em níveis de 10-7 mol L-1. O efeito da presença de outros íons concomitantes sobre a resposta voltamétrica do eletrodo também foi avaliado.
Substâncias húmicas de turfa: estudo dos parâmetros que influenciam no processo de extração alcalina
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new, versatile, and simple method for quantitative analysis of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry is described. These metals can be quantified by direct dissolution of fuel ethanol in water and subsequent voltammetric measurement after the accumulation step. A maximum limit of 20% (v/v) ethanol in water solution was obtained for voltammetric measurements without loss of sensitivity for metal species. Chemical and operational optimum conditions were analyzed in this study; the values obtained were pH 2.9, a 4.7-mum thickness mercury film, a 1,000-rpm rotation frequency of the working electrode, and a 600-s pre-concentration time. Voltammetric measurements were obtained using linear scan (LSV), differential pulse (DPV), and square wave (SWV) modes and detection limits were in the range 10(-9)-10(-8) mol L-1 for these metal species. The proposed method was compared with a traditional analytical technique, flame atomic absorption spectrometry (FAAS), for quantification of these metal species in commercial fuel ethanol samples.
Resumo:
Strontium titanate thin films were prepared by spray pyrolysis technique. Deposition parameters, such as solution concentration, time and temperature of deposition, and flow rate of carrier gas were optimized to obtain dense films without cracks. Films with different thicknesses were prepared through the control of deposition time. Prepared thin films were homogeneous, well crystallized, with uniform grain size. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
This model connects directly the radar reflectivity data and hydrological variable runoff. The catchment is discretized in pixels (4 Km × 4 Km) with the same resolution of the CAPPI. Careful discretization is made so that every grid catchment pixel corresponds precisely to CAPPI grid cell. The basin is assumed a linear system and also time invariant. The forecast technique takes advantage of spatial and temporal resolutions obtained by the radar. The method uses only the measurements of the factor reflectivity distribution observed over the catchment area without using the reflectivity - rainfall rate transformation by the conventional Z-R relationships. The reflectivity values in each catchment pixel are translated to a gauging station by using a transfer function. This transfer function represents the travel time of the superficial water flowing through pixels in the drainage direction ending at the gauging station. The parameters used to compute the transfer function are concentration time and the physiographic catchment characteristics. -from Authors
Resumo:
Objective-To determine the pharmacokinetics of dexmedetomidine administered as a short-duration IV infusion in isoflurane-anesthetized cats. Animals-6 healthy adult domestic female cats. Procedures-Dexmedetomidine hydrochloride was injected IV (10 μg/kg over 5 minutes [rate, 2 μg/kg/min]) in isoflurane-anesthetized cats. Blood samples were obtained immediately prior to and at 1, 2, 5, 6, 7, 10, 15, 30, 60, 90, 120, 240, and 480 minutes following the start of the IV infusion. Collected blood samples were transferred to tubes containing EDTA, immediately placed on ice, and then centrifuged at 3,901 X g for 10 minutes at 4°C. The plasma was harvested and stored at -20°C until analyzed. Plasma dexmedetomidine concentrations were determined by means of liquid chromatography-mass spectrometry. Dexmedetomidine plasma concentration-time data were fitted to compartmental models. Results-A 2-compartment model with input in and elimination from the central compartment best described the disposition of dexmedetomidine administered via short-duration IV infusion in isoflurane-anesthetized cats. Weighted mean ± SEM apparent volume of distribution of the central compartment and apparent volume of distribution at steady-state were 402 ± 47 mL/kg and 1,701 ± 200 mL/kg, respectively; clearance and terminal half-life (harmonic mean ± jackknife pseudo-SD) were 6.3 ± 2.8 mL/min/kg and 198 ± 75 minutes, respectively. The area under the plasma concentration curve and maximal plasma concentration were 1,061 ± 292 min·ng/mL and 17.6 ± 1.8 ng/mL, respectively. Conclusions and Clinical Relevance-Disposition of dexmedetomidine administered via short-duration IV infusion in isoflurane-anesthetized cats was characterized by a moderate clearance and a long terminal half-life.
Resumo:
Objective To describe simultaneous pharmacokinetics (PK) and thermal antinociception after intravenous (IV), intramuscular (IM) and subcutaneous (SC) buprenorphine in cats. Study design Randomized, prospective, blinded, three period crossover experiment. Animals Six healthy adult cats weighing 4.1±0.5kg. Methods Buprenorphine (0.02mgkg-1) was administered IV, IM or SC. Thermal threshold (TT) testing and blood collection were conducted simultaneously at baseline and at predetermined time points up to 24hours after administration. Buprenorphine plasma concentrations were determined by liquid chromatography tandem mass spectrometry. TT was analyzed using anova (p<0.05). A pharmacokinetic-pharmacodynamic (PK-PD) model of the IV data was described using a model combining biophase equilibration and receptor association-dissociation kinetics. Results TT increased above baseline from 15 to 480minutes and at 30 and 60minutes after IV and IM administration, respectively (p<0.05). Maximum increase in TT (mean±SD) was 9.3±4.9°C at 60minutes (IV), 4.6±2.8°C at 45minutes (IM) and 1.9±1.9°C at 60minutes (SC). TT was significantly higher at 15, 60, 120 and 180minutes, and at 15, 30, 45, 60 and 120minutes after IV administration compared to IM and SC, respectively. IV and IM buprenorphine concentration-time data decreased curvilinearly. SC PK could not be modeled due to erratic absorption and disposition. IV buprenorphine disposition was similar to published data. The PK-PD model showed an onset delay mainly attributable to slow biophase equilibration (t1/2ke0=47.4minutes) and receptor binding (kon=0.011mL ng-1minute-1). Persistence of thermal antinociception was due to slow receptor dissociation (t1/2koff=18.2minutes). Conclusions and clinical relevance IV and IM data followed classical disposition and elimination in most cats. Plasma concentrations after IV administration were associated with antinociceptive effect in a PK-PD model including negative hysteresis. At the doses administered, the IV route should be preferred over the IM and SC routes when buprenorphine is administered to cats. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
Resumo:
Gastrotoxicity is a major problem for long-term therapy with non-steroidal anti-inflammatory drugs (NSAIDs). DICCIC (1-(2,6-dichlorophenyl)indolin-2-one) is a new diclofenac prodrug, which has proven anti-inflammatory activity without gastroulcerogenic effect. The aim of this work was to compare the pharmacokinetic profiles of diclofenac from DICCIC (7.6 mg/kg equivalent to 8.1 mg/kg diclofenac) and diclofenac (8.1 mg/kg) administration in Wistar rats weighing 250-300 g (n=20). The doses were calculated by interspecific allometric scaling based on the 2 mg/kg from diary human dose of diclofenac. Blood samples were collected in heparinized tubes via the femoral artery through the implanted catheter. The plasma was separated and quantitation was made in a HPLC system with a UV-Vis detector. The confidence limits of the bioanalytical method were appropriate for its application in a preclinical pharmacokinetic study. The AUC of diclofenac from DICCIC (53.7± 5.8 ug/mL.min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (885.9 ± 124,8 ug/mL.min). Terminal half-life of diclofenac from DICCIC (50.1 ± 17.2 min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (247.4 ± 100.9 min). Still the parameters clearance and distribution volume were calculated for diclofenac from diclofenac, whose results were 9.2 ±1.2 mL/min.kg and 3.3 ±1.2 L/kg, respectively. The results of DICCIC from DICCIC administration were 108.9 ± 19.6 mL/min.kg and 7.8 ± 2.4 L/kg for clearance and distribution volume, respectively. The pharmacokinetic profile demonstrated that there was an increase in diclofenac elimination and a lower exposure to diclofenac with administration of DICCIC compared to diclofenac. © 2013 Bentham Science Publishers.
Resumo:
The purpose of this study was to develop a mucoadhesive stimuli-sensitive drug delivery system for nasal administration of zidovudine (AZT). The system was prepared by formulating a low viscosity precursor of a liquid crystal phase, taking advantage of its lyotropic phase behavior. Flow rheology measurements showed that the formulation composed of PPG-5-CETETH-20, oleic acid and water (55, 30, 15% w/w), denominated P, has Newtonian flow behavior. Polarized light microscopy (PLM) revealed that formulation P is isotropic, whereas its 1:1 (w/w) dilution with artificial nasal mucus (ANM) changed the system to an anisotropic lamellar phase (PD). Oscillatory frequency sweep analysis showed that PD has a high storage modulus (G′) at nasal temperatures. Measurement of the mucoadhesive force against excised porcine nasal mucosa or a mucin disk proved that the transition to the lamellar phase tripled the work of mucoadhesion. Ex vivo permeation studies across porcine nasal mucosa exhibited an 18-fold rise in the permeability of AZT from the formulation. The Weibull mathematical model suggested that the AZT is released by Fickian diffusion mechanisms. Hence, the physicochemical characterization, combined with ex vivo studies, revealed that the PPG-5-CETETH-20, oleic acid, and water formulation could form a mucoadhesive matrix in contact with nasal mucus that promoted nasal absorption of the AZT. For an in vivo assessment, the plasma concentrations of AZT in rats were determined by HPLC method following intravenous and intranasal administration of AZT-loaded P formulation (PA) and AZT solution, respectively, at a dose of 8 mg/kg. The intranasal administration of PA resulted in a fast absorption process (Tmax = 6.7 min). Therefore, a liquid crystal precursor formulation administered by the nasal route might represent a promising novel tool for the systemic delivery of AZT and other antiretroviral drugs. In the present study, the uptake of AZT absorption in the nasal mucosa was demonstrated, providing new foundations for clinical trials in patients with AIDS. © 2012 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)