909 resultados para comparison methods


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The national and Victorian burden of disease studies in Australia set out to examine critically the methods used in the Global Burden of Disease study to estimate the burden of mental disorders. The main differences include the use of a different set of disability weights allowing estimates in greater detail by level of severity, adjustments for comorbidity between mental disorders, a greater number of menta I disorders measured, and model ling of substance use disorders, anxiety disorders and bipolar disorder as chronic conditions. Uniform age-weighting in the Australian studies produces considerably lower estimates of the burden due to mental disorders in comparison with age-weighted disability-adjusted life years. A lack of follow-up data on people with mental disorders who are identified in cross-sectional surveys poses the greatest challenge in determining the burden of mental disorders more accurately.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The possibility of obtaining transplantable oral epithelia opens new perspectives for oral treatments. Most of them are surgical, resulting in mucosal failures. As reconstructive material this in vitro epithelia would be also useful for other parts of the human body. Many researchers still use controversial methods; therefore it was evaluated and compared the efficiency of the enzymatic and direct explant methods to obtain oral keratinocytes. To this project oral epithelia fragments were used. This work compared: time needed for cell obtainment, best cell amount, life-span and epithelia forming cell capacity. The results showed the possibility to obtain keratinocytes from a small oral fragment and we could verify the advantages and peculiar restrictions. We concluded that under our conditions the enzymatic method showed the best results: in the cells obtaining time needed, cell amount and life-span. Both methods showed the same capacity to form in vitro epithelia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the comparison of surface diffusivities of hydrocarbons in activated carbon. The surface diffusivities are obtained from the analysis of kinetic data collected using three different kinetics methods- the constant molar flow, the differential adsorption bed and the differential permeation methods. In general the values of surface diffusivity obtained by these methods agree with each other, and it is found that the surface diffusivity increases very fast with loading. Such a fast increase can not be accounted for by a thermodynamic Darken factor, and the surface heterogeneity only partially accounts for the fast rise of surface diffusivity versus loading. Surface diffusivities of methane, ethane, propane, n-butane, n-hexane, benzene and ethanol on activated carbon are reported in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare accumulated oxygen deficit data derived using two different exercise protocols with the aim of producing a less time-consuming test specifically for use with athletes. Six road and four track male endurance cyclists performed two series of cycle ergometer tests. The first series involved five 10 min sub-maximal cycle exercise bouts, a (V) over dotO(2peak) test and a 115% (V) over dotO(2peak) test. Data from these tests were used to estimate the accumulated oxygen deficit according to the calculations of Medbo et al. (1988). In the second series of tests, participants performed a 15 min incremental cycle ergometer test followed, 2 min later, by a 2 min variable resistance test in which they completed as much work as possible while pedalling at a constant rate. Analysis revealed that the accumulated oxygen deficit calculated from the first series of tests was higher (P< 0.02) than that calculated from the second series: 52.3 +/- 11.7 and 43.9 +/- 6.4 ml . kg(-1), respectively (mean +/- s). Other significant differences between the two protocols were observed for (V) over dot O-2peak, total work and maximal heart rate; all were higher during the modified protocol (P

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACTAiming to compare three different methods for the determination of organic carbon (OC) in the soil and fractions of humic substances, seventeen Brazilian soil samples of different classes and textures were evaluated. Amounts of OC in the soil samples and the humic fractions were measured by the dichromate-oxidation method, with and without external heating in a digestion block at 130 °C for 30 min; by the loss-on-ignition method at 450 °C during 5 h and at 600 °C during 6 h; and by the dry combustion method. Dry combustion was used as reference in order to measure the efficiency of the other methods. Soil OC measured by the dichromate-oxidation method with external heating had the highest efficiency and the best results comparing to the reference method. When external heating was not used, the mean recovery efficiency dropped to 71%. The amount of OC was overestimated by the loss-on-ignition methods. Regression equations obtained between total OC contents of the reference method and those of the other methods showed relatively good adjustment, but all intercepts were different from zero (p < 0.01), which suggests that more accuracy can be obtained using not one single correction factor, but considering also the intercept. The Walkley-Black method underestimated the OC contents of the humic fractions, which was associated with the partial oxidation of the humin fraction. Better results were obtained when external heating was used. For the organic matter fractions, the OC in the humic and fulvic acid fractions can be determined without external heating if the reference method is not available, but the humin fraction requires the external heating.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT The objective of this work was to study the distribution of values of the coefficient of variation (CV) in the experiments of papaya crop (Carica papaya L.) by proposing ranges to guide researchers in their evaluation for different characters in the field. The data used in this study were obtained by bibliographical review in Brazilian journals, dissertations and thesis. This study considered the following characters: diameter of the stalk, insertion height of the first fruit, plant height, number of fruits per plant, fruit biomass, fruit length, equatorial diameter of the fruit, pulp thickness, fruit firmness, soluble solids and internal cavity diameter, from which, value ranges were obtained for the CV values for each character, based on the methodology proposed by Garcia, Costa and by the standard classification of Pimentel-Gomes. The results obtained in this study indicated that ranges of CV values were different among various characters, presenting a large variation, which justifies the necessity of using specific evaluation range for each character. In addition, the use of classification ranges obtained from methodology of Costa is recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present research paper presents five different clustering methods to identify typical load profiles of medium voltage (MV) electricity consumers. These methods are intended to be used in a smart grid environment to extract useful knowledge about customer’s behaviour. The obtained knowledge can be used to support a decision tool, not only for utilities but also for consumers. Load profiles can be used by the utilities to identify the aspects that cause system load peaks and enable the development of specific contracts with their customers. The framework presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partition, which is supported by cluster validity indices. The process ends with the analysis of the discovered knowledge. To validate the proposed framework, a case study with a real database of 208 MV consumers is used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper proposes two meta-heuristics (Genetic Algorithm and Evolutionary Particle Swarm Optimization) for solving a 15 bid-based case of Ancillary Services Dispatch in an Electricity Market. A Linear Programming approach is also included for comparison purposes. A test case based on the dispatch of Regulation Down, Regulation Up, Spinning Reserve and Non-Spinning Reserve services is used to demonstrate that the use of meta-heuristics is suitable for solving this kind of optimization problem. Faster execution times and lower computational resources requirements are the most relevant advantages of the used meta-heuristics when compared with the Linear Programming approach.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electricity market players operating in a liberalized environment requires access to an adequate decision support tool, allowing them to consider all the business opportunities and take strategic decisions. Ancillary services represent a good negotiation opportunity that must be considered by market players. For this, decision support tool must include ancillary market simulation. This paper proposes two different methods (Linear Programming and Genetic Algorithm approaches) for ancillary services dispatch. The methodologies are implemented in MASCEM, a multi-agent based electricity market simulator. A test case based on California Independent System Operator (CAISO) data concerning the dispatch of Regulation Down, Regulation Up, Spinning Reserve and Non-Spinning Reserve services is included in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives : The purpose of this article is to find out differences between surveys using paper and online questionnaires. The author has deep knowledge in the case of questions concerning opinions in the development of survey based research, e.g. the limits of postal and online questionnaires. Methods : In the physician studies carried out in 1995 (doctors graduated in 1982-1991), 2000 (doctors graduated in 1982-1996), 2005 (doctors graduated in 1982-2001), 2011 (doctors graduated in 1977-2006) and 457 family doctors in 2000, were used paper and online questionnaires. The response rates were 64%, 68%, 64%, 49% and 73%, respectively. Results : The results of the physician studies showed that there were differences between methods. These differences were connected with using paper-based questionnaire and online questionnaire and response rate. The online-based survey gave a lower response rate than the postal survey. The major advantages of online survey were short response time; very low financial resource needs and data were directly loaded in the data analysis software, thus saved time and resources associated with the data entry process. Conclusions : The current article helps researchers with planning the study design and choosing of the right data collection method.