981 resultados para building cooling load


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most of today’s embedded systems are required to work in dynamic environments, where the characteristics of the computational load cannot always be predicted in advance. Furthermore, resource needs are usually data dependent and vary over time. Resource constrained devices may need to cooperate with neighbour nodes in order to fulfil those requirements and handle stringent non-functional constraints. This paper describes a framework that facilitates the distribution of resource intensive services across a community of nodes, forming temporary coalitions for a cooperative QoSaware execution. The increasing need to tailor provided service to each application’s specific needs determines the dynamic selection of peers to form such a coalition. The system is able to react to load variations, degrading its performance in a controlled fashion if needed. Isolation between different services is achieved by guaranteeing a minimal service quality to accepted services and by an efficient overload control that considers the challenges and opportunities of dynamic distributed embedded systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Gestão de Sistemas Ambientais

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado integrado em Engenharia do Ambiente, perfil: Gestão de Sistemas Ambientais

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solar passive strategies that have been developed in vernacular architecture from different regions are a response to specific climate effects. These strategies are usually simple, low-tech and have low potential environmental impact. For this reason, several studies highlight them as having potential to reduce the demands of non-renewable energy for buildings operation. In this paper, the climatic contrast between northern and southern parts of mainland Portugal is presented, namely the regions of Beira Alta and Alentejo. Additionally, it discusses the contribution of different climate-responsive strategies developed in vernacular architecture from both regions to assure thermal comfort conditions. In Beira Alta, the use of glazed balconies as a strategy to capture solar gains is usual, while in Alentejo the focus is on passive cooling strategies. To understand the effectiveness of these strategies, thermal performances and comfort conditions of two case studies were evaluated based on the adaptive comfort model. Field tests included measurement of hygrothermal parameters and surveys on occupants’ thermal sensation. From the results, it has been found that the case studies have shown a good thermal performance by passive means alone and that the occupants feel comfortable, except during winter where there is the need to use simple heating systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

*********** Some files are large and will take time to load. *********** Seven Files: 1)Report Cover, 2)Table of Contents, 3)Statewide Financial Summaries, 4)Department Budgets, 5)Capitol Projects, 6)Associated Financial Documents, 7)Budget Report. To Members of the 82nd General Assembly, As we begin the second year of our Administration, we are pleased to submit the Fiscal Year 2009 budget for the State of Iowa pursuant to Iowa Code Section 8.21 and our constitutional authority. This budget recognizes the progress that we began last year with improvements in education, economic development, energy independence, and health care; provides funding for new policy initiatives in these areas; and is based on fiscally sound budget practices. Building on last year’s accomplishments, our Fiscal Year 2009 General Fund budget proposes an additional $75 million for increasing teachers’ salaries as part of our goal to move Iowa closer to the national average. We lay the foundation for student achievement by recommending $32.1 million for pre-school education, and we also propose $177.5 million in total for community colleges and $726.2 million in total for Regents universities. To make our State more energy independent, our General Fund budget appropriates the second-year funding of $25 million for the new Iowa Power Fund. The newly established Office of Energy Independence will soon start making awards from the Power Fund. Apart from the budget, we will be making several proposals to implement the new State energy plan. We have pledged to expand the number of Iowans who have health-care coverage. As a result, we are recommending additional funding for enrollment growth in the State Children Health Insurance Program (SCHIP). These additional funds will help the State provide coverage for another 25 percent of children who are eligible but not yet enrolled in hawk-i and the Iowa Medicaid Program. To protect the safety of Iowans, we are recommending issuance of revenue bonds for approximately $260 million in net proceeds to build a new state penitentiary in Ft. Madison, renovate and expand the Women’s Correctional Institution at Mitchellville, upgrade kitchen facilities at the Rockwell City and Mt. Pleasant Correctional Institutions, and expand Community-Based Correctional Facilities in Ottumwa, Sioux City, Waterloo, and Des Moines. Additionally, we are including funding for developing a prototype program for providing parolees and low-risk offenders with mental health and drug abuse treatment and educational services to help them make a crime-free re-entry into our communities. As part of this Capitals Budget, we also propose using $20 million for the State’s matching share for building new facilities at the Iowa Veterans Home. Iowa Budget Report iv Fiscal Year 2009 Importantly, our budget continues to fully fund our State’s Reserve Funds to help buffer Iowa from any future economic downturn. We recommend reimbursing $78.2 million to the Property Tax Credit Fund as part of our multi-year proposal to correct bad budgeting practices and eventually restore $160.0 million to this Fund. To provide more transparency, we are transferring operational expenditures in the Rebuild Iowa Infrastructure Fund to the General Fund and expenditures from the Endowment for Healthy Iowans and Healthy Iowans Tobacco Trust Funds to the General Fund. We believe that Iowa has charted a new course of becoming energy independent, providing quality pre-school education, recognizing the importance of our teachers, and providing greater health coverage for children. Our Fiscal Year 2009 budget and policy priorities reflect our continuing faith in Iowa’s ability to be the best state in the nation. We look forward to working with you in a bi-partisan and all-inclusive manner to build on our progress and protect our priorities. Sincerely, Chester J. Culver Governor Patty Judge Lt. Governor

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today’s commercial web sites are under heavy user load and they are expected to be operational and available at all times. Distributed system architectures have been developed to provide a scalable and failure tolerant high availability platform for these web based services. The focus on this thesis was to specify and implement resilient and scalable locally distributed high availability system architecture for a web based service. Theory part concentrates on the fundamental characteristics of distributed systems and presents common scalable high availability server architectures that are used in web based services. In the practical part of the thesis the implemented new system architecture is explained. Practical part also includes two different test cases that were done to test the system's performance capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two classes of compounds have been prepared and characterized as building blocks for chiral magnets and ferromagnetic conductors. In the fIrst project, the organic framework of a pentadentate, (N302) macro cycle has been synthetically modifIed to introduce phenyl substituents into its organic framework and the synthesis of four new [Fe(In(N302)(CN)2] complexes (I) - (IV) is presented. [Molecular diagram availble in pdf] This work represents the fIrst structural and magnetic studies of a family of spin crossover macrocycles that comprise of both structural and stereo-isomers. Magnetic susceptibility and Mossbauer data for the R,R-complex (I) is consistent with both a thermal and a light induced spin crossover transition. The X-ray data supports a change in geometry accompanying the thermal spin transition, from a high spin (HS) 7 -coordinate complex at room temperature to a low spin (LS) 5-coordinate complex at 100 K. The crystal structure ofthe racemic complex (III) reveals a HS, 7-coordinate complex at 200 K that undergoes no signifIcant structural changes on cooling. In contrast, the magnetic - susceptibility and Mossbauer data collected on a powder sample of the racemic complex are consistent with a LS complex. Finally, the meso complex (IV) was prepared and its structure and magnetic properties are consistent with a 5-coordinate LS complex that remains low spin, but undergoes conformational changes on cooling in solution. The chiral [Fe(H)(N302)(CN)2] macro cycle (I), together with its Mn(H) and Fe(H) derivatives have also been exploited as building blocks for the self-assembly of chiral magnets. In the second project, a synthetic route for the preparation of tetrathiafulvalene (TTF) donors covalently attached to a diisopropyl verdazyl radical via a cross conjugated pyridyl linker IS presented. Following this strategy, four new TTF-py- (diisopropyl)verdazyl radicals have been prepared and characterized (V) - (VIII) . [Molecular diagram available in pdf] The first (2:1) charge transfer complex ofa TTF-py-(diisopropyl)verdazyl radical donor and a TCNQ acceptor has been prepared and structurally characterized. The crystal packing shows that the donor and acceptor molecules are organized in a mixed stacking arrangement consistent with its insulating behaviour. EPR and magnetic susceptibility data support intramolecular ferromagnetic interactions between the TTF and the verdazyl radicals and antiferromagnetic interactions between TTF donors within a stack. In an attempt to increase the intramolecular exchange interaction between the two radicals, a TTF-x-(diisopropyl)verdazyl radical (IX) was prepared, where the two radicals are connected ia a conjugated divinylene linker. The neutral radical donors stack in a more favourable head-to-head arrangement but the bulky isopropyl groups prevent the donor radicals from stacking close enough together to facilitate good orbital overlap. [Molecular diagram available in pdf].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Passive solar building design is the process of designing a building while considering sunlight exposure for receiving heat in winter and rejecting heat in summer. The main goal of a passive solar building design is to remove or reduce the need of mechanical and electrical systems for cooling and heating, and therefore saving energy costs and reducing environmental impact. This research will use evolutionary computation to design passive solar buildings. Evolutionary design is used in many research projects to build 3D models for structures automatically. In this research, we use a mixture of split grammar and string-rewriting for generating new 3D structures. To evaluate energy costs, the EnergyPlus system is used. This is a comprehensive building energy simulation system, which will be used alongside the genetic programming system. In addition, genetic programming will also consider other design and geometry characteristics of the building as search objectives, for example, window placement, building shape, size, and complexity. In passive solar designs, reducing energy that is needed for cooling and heating are two objectives of interest. Experiments show that smaller buildings with no windows and skylights are the most energy efficient models. Window heat gain is another objective used to encourage models to have windows. In addition, window and volume based objectives are tried. To examine the impact of environment on designs, experiments are run on five different geographic locations. Also, both single floor models and multi-floor models are examined in this research. According to the experiments, solutions from the experiments were consistent with respect to materials, sizes, and appearance, and satisfied problem constraints in all instances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A wind catcher/tower natural ventilation system was installed in a seminar room in the building of the School of Construction Management and Engineering, the University of Reading in the UK . Performance was analysed by means of ventilation tracer gas measurements, indoor climate measurements (temperature, humidity, CO2) and occupant surveys. In addition, the potential of simple design tools was evaluated by comparing observed ventilation results with those predicted by an explicit ventilation model and the AIDA implicit ventilation model. To support this analysis, external climate parameters (wind speed and direction, solar radiation, external temperature and humidity) were also monitored. The results showed the chosen ventilation design provided a substantially greater ventilation rate than an equivalent area of openable window. Also air quality parameters stayed within accepted norms while occupants expressed general satisfaction with the system and with comfort conditions. Night cooling was maximised by using the system in combination with openable windows. Comparisons of calculations with ventilation rate measurements showed that while AIDA gave reasonably correlated results with the monitored performance results, the widely used industry explicit model was found to over estimate the monitored ventilation rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupants’ behaviour when improving the indoor environment plays a significant role in saving energy in buildings. Therefore the key step to reducing energy consumption and carbon emissions from buildings is to understand how occupants interact with the environment they are exposed to in terms of achieving thermal comfort and well-being; though such interaction is complex. This paper presents a dynamic process of occupant behaviours involving technological, personal and psychological adaptations in response to varied thermal conditions based on the data covering four seasons gathered from the field study in Chongqing, China. It demonstrates that occupants are active players in environmental control and their adaptive responses are driven strongly by ambient thermal stimuli and vary from season to season and from time to time, even on the same day. Positive, dynamic, behavioural adaptation will help save energy used in heating and cooling buildings. However, when environmental parameters cannot fully satisfy occupants’ requirements, negative behaviours could conflict with energy saving. The survey revealed that about 23% of windows are partly open for fresh air when air-conditioners are in operation in summer. This paper addresses the issues how the building and environmental systems should be designed, operated and managed in a way that meets the requirements of energy efficiency without compromising wellbeing and productivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are varieties of physical and behavioral factors to determine energy demand load profile. The attainment of the optimum mix of measures and renewable energy system deployment requires a simple method suitable for using at the early design stage. A simple method of formulating load profile (SMLP) for UK domestic buildings has been presented in this paper. Domestic space heating load profile for different types of houses have been produced using thermal dynamic model which has been developed using thermal resistant network method. The daily breakdown energy demand load profile of appliance, domestic hot water and space heating can be predicted using this method. The method can produce daily load profile from individual house to urban community. It is suitable to be used at Renewable energy system strategic design stage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.