992 resultados para balance mass model
Resumo:
Background/Aims: Statistical analysis of age-at-onset involving family data is particularly complicated because there is a correlation pattern that needs to be modeled and also because there are measurements that are censored. In this paper, our main purpose was to evaluate the effect of genetic and shared family environmental factors on age-at-onset of three cardiovascular risk factors: hypertension, diabetes and high cholesterol. Methods: The mixed-effects Cox model proposed by Pankratz et al. [2005] was used to analyze the data from 81 families, involving 1,675 individuals from the village of Baependi, in the state of Minas Gerais, Brazil. Results: The analyses performed showed that the polygenic effect plays a greater role than the shared family environmental effect in explaining the variability of the age-at-onset of hypertension, diabetes and high cholesterol. The model which simultaneously evaluated both effects indicated that there are individuals which may have risk of hypertension due to polygenic effects 130% higher than the overall average risk for the entire sample. For diabetes and high cholesterol the risks of some individuals were 115 and 45%, respectively, higher than the overall average risk for the entire population. Conclusions: Results showed evidence of significant polygenic effects indicating that age-at-onset is a useful trait for gene mapping of the common complex diseases analyzed. In addition, we found that the polygenic random component might absorb the effects of some covariates usually considered in the risk evaluation, such as gender, age and BMI. Copyright (C) 2008 S. Karger AG, Basel
Resumo:
A new integrated mathematical model for the simulation of offshore wind energy conversion system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using full-power two-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a high voltage DC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the structure and tower due to the need to emulate the effects of the moving surface. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistor of the converter. Finally, a case study is presented to access the system performance. © 2014 IEEE.
Resumo:
This paper is on offshore wind energy conversion systems installed on the deep water and equipped with back-to-back neutral point clamped full-power converter, permanent magnet synchronous generator with an AC link. The model for the drive train is a five-mass model which incorporates the dynamic of the structure and the tower in order to emulate the effect of the moving surface. A three-level converter and a four-level converter are the two options with a fractional-order control strategy considered to equip the conversion system. Simulation studies are carried out to assess the quality of the energy injected into the electric grid. Finally, conclusions are presented. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
A new integrated mathematical model for the simulation of offshore wind energy conversion system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using full-power two-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a high voltage DC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the structure and tower due to the need to emulate the effects of the moving surface. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistor of the converter. Finally, a case study is presented to access the system performance. © 2014 IEEE.
Resumo:
This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This paper is on a simulation for offshore wind systems in deep water under cloud scope. The system is equipped with a permanent magnet synchronous generator and a full-power three-level converter, converting the electric energy at variable frequency in one at constant frequency. The control strategies for the three-level are based on proportional integral controllers. The electric energy is injected through a HVDC transmission submarine cable into the grid. The drive train is modeled by a three-mass model taking into account the resistant stiffness torque, structure and tower in the deep water due to the moving surface elevation. Conclusions are taken on the influence of the moving surface on the energy conversion. © IFIP International Federation for Information Processing 2015.
Resumo:
This paper deals with a computing simulation for an offshore wind energy system taking into account the influence of the marine waves action throughout the floating platform. The wind energy system has a variable-speed turbine equipped with a permanent magnet synchronous generator and a full-power five level converter, injecting energy into the electric grid through a high voltage alternate current link. A reduction on the unbalance of the voltage in the DC-link capacitors of the five-level converter is proposed by a strategic selection of the output voltage vectors. The model for the drive train of the wind energy system is a two mass model, including the dynamics of the floating platform. A case study is presented and the assessment of the quality of the energy injected into the electric grid is discussed.
Resumo:
A summary is presented of ATLAS searches for gluinos and first- and second-generation squarks in final states containing jets and missing transverse momentum, with or without leptons or b-jets, in the s√=8 TeV data set collected at the Large Hadron Collider in 2012. This paper reports the results of new interpretations and statistical combinations of previously published analyses, as well as a new analysis. Since no significant excess of events over the Standard Model expectation is observed, the data are used to set limits in a variety of models. In all the considered simplified models that assume R-parity conservation, the limit on the gluino mass exceeds 1150 GeV at 95% confidence level, for an LSP mass smaller than 100 GeV. Furthermore, exclusion limits are set for left-handed squarks in a phenomenological MSSM model, a minimal Supergravity/Constrained MSSM model, R-parity-violation scenarios, a minimal gauge-mediated supersymmetry breaking model, a natural gauge mediation model, a non-universal Higgs mass model with gaugino mediation and a minimal model of universal extra dimensions.
Resumo:
This study aimed to determine changes in spring-mass model (SMM) characteristics, plantar pressures, and muscle activity induced by the repetition of sprints in soccer-specific conditions; i.e., on natural grass with soccer shoes. Thirteen soccer players performed 6 × 20 m sprints interspersed with 20 s of passive recovery. Plantar pressure distribution was recorded via an insole pressure recorder device divided into nine areas for analysis. Stride temporal parameters allowed to estimate SMM characteristics. Surface electromyographic activity was monitored for vastus lateralis, rectus femoris, and biceps femoris muscles. Sprint time, contact time, and total stride duration lengthened from the first to the last repetition (+6.7, +12.9, and +9.3%; all P < 0.05), while flight time, swing time, and stride length remained constant. Stride frequency decrease across repetitions approached significance (-6.8%; P = 0.07). No main effect of the sprint number or any significant interaction between sprint number and foot region was found for maximal force, mean force, peak pressure and mean pressure (all P > 0.05). Center of mass vertical displacement increased (P < 0.01) with time, together with unchanged (both P > 0.05) peak vertical force and leg compression. Vertical stiffness decreased (-15.9%; P < 0.05) across trials, whereas leg stiffness changes were not significant (-5.9%; P > 0.05). Changes in root mean square activity of the three tested muscles over sprint repetitions were not significant. Although repeated sprinting on natural grass with players wearing soccer boots impairs their leg-spring behavior (vertical stiffness), there is no substantial concomitant alterations in muscle activation levels or plantar pressure patterns.
Resumo:
OBJECTIVES: This study aimed to determine adjustments in spring-mass model characteristics, plantar loading and foot mobility induced by an exhaustive run. DESIGN: Within-participants repeated measures. METHODS: Eleven highly-trained adolescent middle-distance runners ran to exhaustion on a treadmill at a constant velocity corresponding to 95% of velocity associated with VO₂max (17.8 ± 1.4 kmh(-1), time to exhaustion=8.8 ± 3.4 min). Contact time obtained from plantar pressure sensors was used to estimate spring-mass model characteristics, which were recorded (during 30 s) 1 min after the start and prior to exhaustion using pressure insoles. Foot mobility magnitude (a composite measure of vertical and medial-lateral mobility of the midfoot) was measured before and after the run. RESULTS: Mean contact area (foot to ground), contact time, peak vertical ground reaction force, centre of mass vertical displacement and leg compression increased significantly with fatigue, while flight time, leg stiffness and mean pressure decreased. Leg stiffness decreased because leg compression increased to a larger extent than peak vertical ground reaction forces. Step length, step frequency and foot mobility magnitude did not change at exhaustion. CONCLUSIONS: The stride pattern of adolescents when running on a treadmill at high constant velocity deteriorates near exhaustion, as evidenced by impaired leg-spring behaviour (leg stiffness) and altered plantar loading.
Resumo:
Työn tavoitteena oli laatia reaaliaikaiset vesi- ja energiatasenäytöt Stora Enso PublicationPaper Veitsiluodon tehtaalle, paperikone 5:lle. Tavoitteena oli myös simuloida kyseisen paperikonelinjan vesitase. Aluksi työssä piirrettiin lohkokaaviot taseita varten paperikoneen kaikista vettä tai energiaa sisältävistä jakeista. Näitä yksinkertaistettuja lohkokaavioita hyväksi käyttäen laadittiin taseidenlaskentakaavat, jotka testattiin tarkastuslaskelmien avulla. Vesi- ja energiataseista tehtiin myös suunnitelmat prosessinohjausjärjestelmän tasenäytöiksi. FlowMac-simulointiohjelmalla rakennetun paperikone 5 vesitaseen simulointimallin tulosten oikeellisuutta arvioitiin herkkyysanalyysin avulla. Tehdyn herkkyysanalyysin tuloksien perusteella voidaan olettaa, että simulointimalli toimii luotettavasti. Tämän vesitaseen simulointimallin avulla tarkasteltiin kiekkosuotimien uudistamisen vaikutuksia paperikonelinjan vesitaseeseen. Tarkastelussa huomattiin, että vaihtamalla kiekkosuotimien syöttöventtiilit kolmea jaetta tuottaviksi, voitaisiin flotaatioallas ja suihkuveden kaarisihti poistaa käytöstä. Tulevaisuudessa simulointimallia voidaan käyttää myös monilla muilla eri tavoin hyödyksi kyseisellä paperikoneella. Työssä laaditut vesi- ja energiataseet saatiin niin tarkoiksi kuin se nykyisiä mittauksia hyödyntäen on mahdollista. Jostaseita haluttaisiin tarkentaa, olisi paperikonelinjalle syytä lisätä joitakin mittauksia. Myös työssä tehty vesitaseen simulointi FlowMac:lla onnistui hyvin mutta kyseisessä ohjelmassa havaittiin silti joitakin kehittämistarpeita. Työn tuloksien perusteella vettä ja energiaa voitaisiin mahdollisesti säästää paperikone 5:llä esimerkiksi laimennussäätöisen perälaatikon avulla, kiekkosuotimien uusimisella sekä kenkäpuristimen käyttöönotolla. Jatkotutkimuskohteita voisivat olla esimerkiksi paperikone 5:n lämpötase, kemiallisesti puhdistetun veden tulolämpötilan nostaminen, hiomon suodosveden ylimääräisen lämmön hyödyntäminen paperikone 5 kirkassuodoksen lämmittämisen jälkeen, lämmön talteenotossa lämmitysvesikennon ja prosessivesikennon järjestyksen vaihtaminen sekä vastaavien vesi- ja energiataseiden laatiminen paperikone 1:lle ja hiomolle.
Resumo:
Industry's growing need for higher productivity is placing new demands on mechanisms connected with electrical motors, because these can easily lead to vibration problems due to fast dynamics. Furthermore, the nonlinear effects caused by a motor frequently reduce servo stability, which diminishes the controller's ability to predict and maintain speed. Hence, the flexibility of a mechanism and its control has become an important area of research. The basic approach in control system engineering is to assume that the mechanism connected to a motor is rigid, so that vibrations in the tool mechanism, reel, gripper or any apparatus connected to the motor are not taken into account. This might reduce the ability of the machine system to carry out its assignment and shorten the lifetime of the equipment. Nonetheless, it is usually more important to know how the mechanism, or in other words the load on the motor, behaves. A nonlinear load control method for a permanent magnet linear synchronous motor is developed and implemented in the thesis. The purpose of the controller is to track a flexible load to the desired velocity reference as fast as possible and without awkward oscillations. The control method is based on an adaptive backstepping algorithm with its stability ensured by the Lyapunov stability theorem. As a reference controller for the backstepping method, a hybrid neural controller is introduced in which the linear motor itself is controlled by a conventional PI velocity controller and the vibration of the associated flexible mechanism is suppressed from an outer control loop using a compensation signal from a multilayer perceptron network. To avoid the local minimum problem entailed in neural networks, the initial weights are searched for offline by means of a differential evolution algorithm. The states of a mechanical system for controllers are estimated using the Kalman filter. The theoretical results obtained from the control design are validated with the lumped mass model for a mechanism. Generalization of the mechanism allows the methods derived here to be widely implemented in machine automation. The control algorithms are first designed in a specially introduced nonlinear simulation model and then implemented in the physical linear motor using a DSP (Digital Signal Processor) application. The measurements prove that both controllers are capable of suppressing vibration, but that the backstepping method is superior to others due to its accuracy of response and stability properties.
Resumo:
Pyrolyysiöljy on biomassasta nopealla hapettomalla lämpökäsittelyprosessilla saatavaa nestemäistä polttoainetta. Kasvavien uusiutuvan energian käyttötavoitteiden myötä pyrolyysiöljystä on tullut kiinnostava vaihtoehto fossiilisille polttoöljyille. Suurimmat käytön haasteet ovat alhainen lämpöarvo, korkeat kiintoainepitoisuudet ja happamuus fossiilisiin polttoöljyihin verrattuna sekä eri raaka-aineista syntyvät ominaisuuksiltaan erilaiset pyrolyysiöljyt. Pyrolyysiöljyn kaupallinen tuotanto on vasta käynnistymässä eikä sen laadulle ole olemassa standardeja, joten eri valmistajien tuotteet voivat poiketa toisistaan huomattavastikin. Suomessa on Valtion teknillisen tutkimuskeskuksen (VTT) toimesta kehitetty Integrated Thermal Process (ITP)-konsepti, jossa pyrolyysiöljyn tuotantoprosessi on liitetty kiertoleijukattilaprosessiin. Prosessien yhdistämisellä voidaan parantaa kokonaishyötysuhdetta sekä hyödyntää laitosten yhteistä käyttöä ja polttoaineen hankintaa. Pyrolyysiprosessin tarvitsema lämpöenergia otetaan petihiekan välityksellä kattilasta, jossa poltetaan myös prosessissa syntyvät oheistuotteet. Tässä diplomityössä tutkittiin pyrolyysiprosessin vaikutusta voimalaitoksen toimintaan ja luotiin malli voimalaitoksen energiataseessa tapahtuvien muutosten arviointiin. Malli laskee sekä pyrolysaattorin että raaka-aineen käsittelyn vaikutukset voimalaitoksen sähkön- ja lämmöntuotantoon. Lisäksi mallin avulla voidaan arvioida pyrolysaattorin aiheuttama raaka-aineen tarve sekä voimalaitoksen lisäpolttoaineen tarve. Työssä tarkasteltiin myös pyrolyysiöljyn ominaisuuksia ja käyttökohteita, sekä tarvittavia muutoksia olemassa olevaan voimalaitokseen. Lisäksi arvioitiin tuotannon kannattavuutta. Mallia sovellettiin esimerkkivoimalaitokseen, jossa on harkittu pyrolyysiöljyn tuotannon aloittamista. Laskelmien perusteella pyrolyysiöljyn tuotannolla on sähkön- ja lämmöntuotantoa alentava sekä polttoaineen tarvetta korottava vaikutus. Pyrolyysiprosessin lisääminen nostaa voimalaitoksen kokonaishyötysuhdetta. Suotuisissa olosuhteissa öljytuotanto ITP-konseptilla näyttäisi olevan taloudellisesti kannattavaa.
Resumo:
Tämän diplomityön tavoitteena oli tutkia tasehallinnan kehittämismahdollisuuksia Suomessa järjestelmävastaavan näkökulmasta. Sähköjärjestelmässä tulee vallita jatkuvasti tasapaino tuotannon ja kulutuksen välillä, tämän järjestelmävastaavan vastuulla olevan tasapainon ylläpitoa kutsutaan tehotasapainon hallinnaksi. Työssä pääasiasiallinen huomio oli markkinalähtöisessä tehotasapainon hallinnan kehittämisessä. Tuotantosuunnitelmat ovat ratkaisevassa osassa sähköjärjestelmän muutoksia ennustettaessa ja suunniteltaessa. Pääasiassa tutkimus kohdistuu tuotantosuunnitelmien tarkentamisen mahdollisuuksien analysointiin sekä tarkentamisesta aiheutuvien muutosten selvittämiseen. Työn yhteydessä toteutettiin sopivalla otannalla kyselytutkimus, jonka oli tarkoitus antaa tietoa Eurooppalaisista käytännöistä asian suhteen. Tutkimusten pohjalta päädyttiin malliin, jossa tuotantosuunnitelmien jaksonpituutta lyhennettäisiin nykyisestä 60 minuutista 15 minuuttiin. 15 minuutin jaksonpituus ulottuisi koko tuotantotaseen käsittelyyn, mukaan lukien säätösähkömarkkinat ja muut tehokaupat.
Resumo:
Kiinnostus energia-asioiden käsittelemiseen alueellisesti yksittäisen rakennuksen asioiden käsittelyn sijaan on lisääntynyt voimakkaasti viime vuosina. Keskustelu alueellisesta ener-gia-asioista on kuitenkin vasta alussa ja alueellisiin energiatarkasteluihin tarvitaan työväli-neitä. Tämän työn päätavoitteena oli luoda alueellinen energiatasemalli, jolla voidaan laskea alueen rakennuskannan energiankulutusta ja -tuotantoa sekä energiantuotannon hiilidi-oksidipäästöjä helposti ja nopeasti. Työssä perehdyttiin alueellisten energiatarkasteluiden tämän hetken tasoon, työvälineisiin ja ohjeistukseen. Myös Suomen rakentamismääräyskokoelman rakennusten energiatehok-kuusmääräyksiin tutustuttiin. Alueellisen energiatasemallin perustana käytettiin uusien rakentamismääräysten E-lukulaskennan ohjeistusta. Mallin toimivuutta testattiin Helsingin Salmenkallioon rakennettavaan uudisrakennusalueeseen. Testattaessa mallilla laskettiin kyseisen alueen energiankulutus sekä erilaisia energiantuo-tantovaihtoehtoja ja todettiin, että erityisesti energiankulutuksen laskenta on hyvin helppoa, kun alueen rakennusten kerrosalat ovat tiedossa. Tuotantopuolen uusiutuvan energian laskeminen luotettavasti vaatii hiukan enemmän taustatyötä, mutta varsinainen mallin käyt-täminen on helppoa ja tulokset saadaan suoraan selkeinä kuvaajina. Työssä onnistuttiin luomaan tavoitteiden mukainen malli, jota voidaan soveltaa erilaisissa alueellisissa energiatarkasteluissa. Tarkasteltaessa energia-asioita alueellisesti, saadaan esimerkiksi alueen huipputehon tarvetta pienennettyä ja energiantuotantoa optimoitua. Malli ei kuitenkaan ole vielä valmis laskentatyökalu, vaan vaatii jatkokehitystä, mikäli sitä halutaan hyödyntää laajemmin.