897 resultados para automated instruments
Resumo:
Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 mu A/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). Results: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). Conclusions: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation. of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life. (J Endod 2010;36:1183-1186)
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
Background: Newly formed biofilm after implant debridement may challenge the long-term stability of peri-implant therapy. This in vitro study aimed to assess the roughness and adherence of Streptococcus sanguinis after treatment of smooth and rough titanium surfaces with an erbium-doped: yttrium, aluminum, and garnet (Er:YAG) laser, metal and plastic curets, and an air-powder abrasive system. Methods: Forty titanium disks with smooth-machined surfaces and 40 with sand-blasted and acid-etched surfaces were divided into the following treatment groups: Er:YAG laser; plastic curet; metal curet, and air-powder abrasive system. The surface roughness (roughness average [Raj) before and after treatments was determined using a profilometer. S. sanguinis (American Type Culture Collection 10556) was grown on treated and untreated specimens, and the amounts of retained bacteria on the surfaces were measured by the culture method. Rough and smooth surfaces with and without a suspension of S. sanguinis were also analyzed using scanning electron microscopy (SEM). Results: For smooth surfaces, the roughest surfaces were produced by metal curets (repeated - measures analysis of variance [ANOVA] and Tukey test; P<0.05). The rough-surface profile was not altered by any of the treatments (repeated-measures ANOVA; P>0.05). Rough surfaces treated with metal curets and air-powder abrasion showed the lowest level of bacteria] adhesion (two-way ANOVA and Tukey test; P<0.05). SEM analysis revealed distinct surface profiles produced by all devices. Conclusions: Metal curets are not recommended for smooth titanium surface debridement due to severe texture alteration. Rough surfaces treated with a metal curet and the air-powder abrasive system were less susceptible to bacterial adhesion, probably due to texture modification and the presence of abrasive deposits. J Periodontol 2009;80: 1824-1832.
Resumo:
The aim of this study was to compare the concentration of mast cells (MCs) in the healing process of incisions. Thirty rats were submitted to six linear incisions each, performed in the dorsal skin by carbon dioxide (CO(2)) and diode lasers, electrocautery and conventional scalpel. The animals were euthanized at intervals of 0 h, 24 h, 48 h, 72 h, 7 days and 14 days after the incisions had been made. Histological sections were obtained and stained with toluidine blue for identification of MCs, which were manually counted by conventional microscopy in 20 microscopic fields in the border of the incision, near the granulation tissue, or in the area of new collagen formation, depending on intervals. The concentration of MCs was significantly higher in the wounds made by scalpel than in those made by other techniques at 48 h and 72 h. After 72 h the number of MCs was also significantly higher after electrocautery than after incisions made by 4 W CO(2) laser. On days 7 and 14, there was no significant difference in the MC count among the different types of incisions. In summary, the MC concentration varied after different surgical incisions at early phases of wound healing. At the end of the healing process, however, there were similar MC concentrations around the incisions, suggesting that, in standard incisions in the surgical techniques studied, the wound healing process ultimately occurred in a similar pattern.
Resumo:
Evaluate, through computerized tomography, canal transportation and centring ability of RaCe rotary instruments after preparation of mesiobuccal root canals in maxillary molar teeth. Twenty-seven teeth were submitted to three cone beam tomographic analyses, one preoperatively, and two after preparation with file size 35, .02 taper and size 50, .02 taper. Canal transportation and centring ability were measured with reference to the distance between the noninstrumented portion of the root canals and the mesial and distal periphery of the root, compared with images obtained after the preparation with size 35 and 50 instruments. Canal transportation after preparation with the size 35 file was 0.030 +/- 0.253 mm and after the size 50 file was 0.057 +/- 0.317 mm. The centring ratio values after preparation with the size 35 file was 0.42 +/- 0.32 and after the size 50 file was 0.54 +/- 0.29, with no significant statistical difference between the groups. RaCe instruments allowed the preparation of curved root canals with preparation diameters larger than those normally used with minimal canal transportation and adequate centring ability.
Resumo:
Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/-0.65 mm for the manual and 0.03 +/-0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were -0.07 +/-0.38 mm for observer 1 and -0.16 +/-0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.
Resumo:
A system has been developed for studying the biodegradation of natural and synthetic polymeric material. The system is based on standard methods developed by the European Committee for Standardisation (CEN TC 261) (ISO/DIS 14855) and the American Society of Testing Materials, 'ASTM. Standard Test Method for Determining Aerobic. Biodegradation of Plastic Materials under Controlled Composting Conditions' (ASTM D 5338-92). A new low-cost compost facility has been used which satisfies the requirements of these standards. The system has been automated for data collection and has been run under the conditions specified by the standards. In the system, cellulose, newspaper and two starch-based polymers were treated with compost in a series of 3dm(3) vessels at 52 degreesC and under conditions of optimum moisture and pH. The degradation was followed over time by measuring the amount of carbon released as carbon dioxide. (C) 2001 Society of Chemical Industry.
Resumo:
Riparian vegetation can be an effective measure for preventing degradation of streambanks and riparian areas. However, riparian revegetation imposes large costs on landholders associated with tree establishment and removal of land from cropping, while providing benefits to downstream landholders, fishers, the local community and environmentalists. Appropriate policy instruments are required to promote sustainable and balanced use of riparian zones. This article analyses the capacity of existing legislation and other instruments to promote restoration of degraded riparian zones on private land. The role of legislation. economic instruments, community engagement and extension programs, in persuading landholders to revegetate riparian areas and improve riparian vegetation cover; is examined in the context ofa small degraded catchment in an intensive farming area in tropical north Queensland. It is found that while legislation and regulations can control undesirable modification of riparian areas, in general they are unable to make a useful contribution to restoration of these areas; incentives and assistance measures appear to offer greater potential.
Resumo:
Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.
Resumo:
The emphasis of this work is on the optimal design of MRI magnets with both superconducting coils and ferromagnetic rings. The work is directed to the automated design of MRI magnet systems containing superconducting wire and both `cold' and `warm' iron. Details of the optimization procedure are given and the results show combined superconducting and iron material MRI magnets with excellent field characteristics. Strong, homogeneous central magnetic fields are produced with little stray or external field leakage. The field calculations are performed using a semi-analytical method for both current coil and iron material sources. Design examples for symmetric, open and asymmetric clinical MRI magnets containing both superconducting coils and ferromagnetic material are presented.
Resumo:
Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.
Resumo:
The refinement calculus is a well-established theory for deriving program code from specifications. Recent research has extended the theory to handle timing requirements, as well as functional ones, and we have developed an interactive programming tool based on these extensions. Through a number of case studies completed using the tool, this paper explains how the tool helps the programmer by supporting the many forms of variables needed in the theory. These include simple state variables as in the untimed calculus, trace variables that model the evolution of properties over time, auxiliary variables that exist only to support formal reasoning, subroutine parameters, and variables shared between parallel processes.