988 resultados para apnea of prematurit


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Treatment-resistant hypertension is still common despite the availability of several types of antihypertensive agents acting by different mechanisms. The existence of refractory hypertension should lead to rule out "white-coat hypertension", poor adherence to prescribed drugs as well as classical causes of secondary hypertension such as renal artery stenosis, primary aldosteronism, pheochromocytoma and renal disease. It is also important to consider the possible existence of obstructive sleep apnea or the regular intake of vasopressive drugs or substances.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. Materials and Methods: Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P Less-than .05). Results: Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. Conclusions: Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Obstructive sleep apnea syndrome (OSA) increases the risk of cardiovascular disease. We aimed at evaluating the effect of continuous positive airway pressure (CPAP) treatment on coronary endothelium-dependent vasoreactivity in OSA patients by quantifying myocardial blood flow (MBF) response to cold pressure testing (CPT). METHODS: In the morning after polysomnography (PSG), all participants underwent a dynamic (82)Rb cardiac positron emitting tomography/computed tomography (PET/CT) scan at rest, during CPT and adenosine stress. PSG and PET/CT were repeated at least 6 weeks after initiating CPAP treatment. OSA patients were compared to controls and according to response to CPAP. Patients' characteristics and PSG parameters were used to determine predictors of CPT-MBF. RESULTS: Thirty-two untreated OSA patients (age 58 ± 13 years, 27 men) and 9 controls (age 62 ± 5 years, 4 men) were enrolled. At baseline, compared to controls (apnea-hypopnea index (AHI) = 5.3 ± 2.6/h), untreated OSA patients (AHI = 48.6 ± 19.7/h) tend to have a lower CPT-MBF (1.1 ± 0.2 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.09). After initiating CPAP, CPT-MBF was not different between well-treated patients (AHI <10/h) and controls (1.3 ± 0.3 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.83), but it was lower for insufficiently treated patients (AHI ≥10/h) (0.9 ± 0.2 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.0045). CPT-MBF was also higher in well-treated than in insufficiently treated patients (1.3 ± 0.3 mL/min/g vs. 0.9 ± 0.2 mL/min/g, p = 0.001). Mean nocturnal oxygen saturation (β = -0.55, p = 0.02) and BMI (β = -0.58, p = 0.02) were independent predictors of CPT-MBF in OSA patients. CONCLUSIONS: Coronary endothelial vasoreactivity is impaired in insufficiently treated OSA patients compared to well-treated patients and controls, confirming the need for CPAP optimization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

tThis paper deals with the potential and limitations of using voice and speech processing to detect Obstruc-tive Sleep Apnea (OSA). An extensive body of voice features has been extracted from patients whopresent various degrees of OSA as well as healthy controls. We analyse the utility of a reduced set offeatures for detecting OSA. We apply various feature selection and reduction schemes (statistical rank-ing, Genetic Algorithms, PCA, LDA) and compare various classifiers (Bayesian Classifiers, kNN, SupportVector Machines, neural networks, Adaboost). S-fold crossvalidation performed on 248 subjects showsthat in the extreme cases (that is, 127 controls and 121 patients with severe OSA) voice alone is able todiscriminate quite well between the presence and absence of OSA. However, this is not the case withmild OSA and healthy snoring patients where voice seems to play a secondary role. We found that thebest classification schemes are achieved using a Genetic Algorithm for feature selection/reduction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To correlate anatomical and functional changes of the oral cavity, pharynx and larynx to the severity of obstructive sleep apnea syndrome (OSAS). Methods : We conducted a cross-sectional study of 66 patients of both genders, aged between 21 and 59 years old with complaints of snoring and / or apnea. All underwent full clinical evaluation, including physical examination, nasolarybgoscopy and polisonography. We classified individuals into groups by the value of the apnea-hypopnea index (AHI), calculated measures of association and analyzed differences by the Kruskal-Wallis and chi-square tests. Results : all patients with obesity type 2 had OSAS. We found a relationship between the uvula projection during nasoendoscopy and OSAS (OR: 4.9; p-value: 0.008; CI: 1.25-22.9). In addition, there was a major strength of association between the circular shape of the pharynx and the presence of moderate or severe OSAS (OR: 9.4, p-value: 0.002), although the CI was wide (1.80-53.13). The septal deviation and lower turbinate hypertrophy were the most frequent nasal alterations, however unrelated to gravity. Nasal obstruction was four times more common in patients without daytime sleepiness. The other craniofacial anatomical changes were not predictors for the occurrence of OSAS. Conclusion : oral, pharyngeal and laryngeal disorders participate in the pathophysiology of OSAS. The completion of the endoscopic examination is of great value to the evaluation of these patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The presence of abnormalities of the respiratory center in obstructive sleep apnea (OSA) patients and their correlation with polysomnographic data are still a matter of controversy. Moderately obese, sleep-deprived OSA patients presenting daytime hypersomnolence, with normocapnia and no clinical or spirometric evidence of pulmonary disease, were selected. We assessed the ventilatory control and correlated it with polysomnographic data. Ventilatory neuromuscular drive was evaluated in these patients by measuring the ventilatory response (VE), the inspiratory occlusion pressure (P.1) and the ventilatory pattern (VT/TI, TI/TTOT) at rest and during submaximal exercise, breathing room air. These analyses were also performed after inhalation of a hypercapnic mixture of CO2 (DP.1/DPETCO2, DVE/DPETCO2). Average rest and exercise ventilatory response (VE: 12.2 and 32.6 l/min, respectively), inspiratory occlusion pressure (P.1: 1.5 and 4.7 cmH2O, respectively), and ventilatory pattern (VT/TI: 0.42 and 1.09 l/s; TI/TTOT: 0.47 and 0.46 l/s, respectively) were within the normal range. In response to hypercapnia, the values of ventilatory response (DVE/DPETCO2: 1.51 l min-1 mmHg-1) and inspiratory occlusion pressure (DP.1/DPETCO2: 0.22 cmH2O) were normal or slightly reduced in the normocapnic OSA patients. No association or correlation between ventilatory neuromuscular drive and ventilatory pattern, hypersomnolence score and polysomnographic data was found; however a significant positive correlation was observed between P.1 and weight. Our results indicate the existence of a group of normocapnic OSA patients who have a normal awake neuromuscular ventilatory drive at rest or during exercise that is partially influenced by obesity

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of the flow vs time relationship obtained with the nasal prongs of the AutoSetä (AS) system (diagnosis mode) has been proposed to detect apneas and hypopneas in patients with reasonable nasal patency. Our aim was to compare the accuracy of AS to that of a computerized polysomnographic (PSG) system. The study was conducted on 56 individuals (45 men) with clinical characteristics of obstructive sleep apnea (OSA). Their mean (± SD) age was 44.6 ± 12 years and their body mass index was 31.3 ± 7 kg/m2. Data were submitted to parametric analysis to determine the agreement between methods and the intraclass correlation coefficient was calculated. The Student t-test and Bland and Altman plots were also used. Twelve patients had an apnea-hypopnea index (AHI) <10 in bed and 20 had values >40. The mean (± SD) AHI PSG index of 37.6 (28.8) was significantly lower (P = 0.0003) than AHI AS (41.8 (25.3)), but there was a high intraclass correlation coefficient (0.93), with 0.016 variance. For a threshold of AHI of 20, AS showed 73.0% accuracy, 97% sensitivity and 60% specificity, with positive and negative predictive values of 78% and 93%, respectively. Sensitivity, specificity and negative predictive values increased in parallel to the increase in AHI threshold for detecting OSA. However, when the differences of AHI PSG-AS were plotted against their means, the limits of agreement between the methods (95% of the differences) were +13 and -22, showing the discrepancy between the AHI values obtained with PSG and AS. Finally, cubic regression analysis was used to better predict the result of AHI PSG as a function of the method proposed, i.e., AHI AS. We conclude that, despite these differences, AHI measured by AutoSetä can be useful for the assessment of patients with high pre-test clinical probability of OSA, for whom standard PSG is not possible as an initial step in diagnosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the present study was to compare the clinical findings and polysomnography results obtained at public and private clinics in Brazil, the follow-up after diagnosis, and the therapeutic aspects related to continuous positive airway pressure. Patients who snore and who have obstructive sleep apnea were retrospectively divided into two groups, i.e., public clinic (N = 307) and private clinic (N = 317). Data concerning age, sex, body mass index (BMI), neck circumference, medical history, sleepiness scale, follow-up after diagnosis, and acceptance of continuous positive airway pressure therapy were collected. Mean age was 50 ± 12 (range: 15-80) for public patients and 48 ± 12 years (range: 19-91) for private patients. Mean BMI was 30 ± 6 (range: 19-67) for public patients and 31 ± 6 kg/m² (range: 21-59) for private patients. The public clinic had a significantly higher frequency of women than the private clinic (M:F ratio of 2.0:1 and 6.9:1, respectively). The condition of private patients (apnea-hypopnea index = 31 ± 25) was more severe than that of public patients (apnea-hypopnea index = 25 ± 24 events/h; P = 0.0004). In the public and private clinics, 19 and 15% of patients were snorers, respectively, and 81 and 85% of them had sleep apnea. After diagnosis, follow-up was longer in the private group. The continuous positive airway pressure acceptance was similar for both groups (32 vs 35%), but patients from the public clinic abandoned treatment more than private ones (65 vs 13%). Social status was significant in terms of the severity of obstructive sleep apnea age and gender distribution. Private patients look for a diagnosis earlier in the course of the disease than public patients, adhere more to follow-up, and abandon continuous positive airway pressure treatment less than public patients do.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some studies showed that Asians with obstructive sleep apnea (OSA) are thinner than Caucasians. Because obesity is a major risk factor for OSA, it was concluded that Asians are predisposed to OSA. However, body fat composition varies for a same body mass index (BMI) according to ethnicity. We firstly compared anthropometric characteristics, symptoms and associated disorders in all consecutive male Japanese descendants and white males with OSA referred for polysomnography. In a second analysis, all Japanese descendants were compared to a subgroup of white males, matched for apnea/hypopnea index and age. In the first analysis, age, symptoms, OSA severity and co-morbidities were similar among Japanese descendants (N = 54) and white patients (N = 466). However, Japanese descendants had a lower BMI than white patients: 27.1 (25.5-28.4) vs 29.4 (26.5-33.0) kg/m², respectively (P < 0.001). In the second analysis, Japanese descendants had a lower BMI than white patients (P < 0.001). Multiple linear regression considering the entire group revealed that age, BMI, neck circumference, Epworth sleepiness scale, ethnicity and %REM sleep were independent predictors for apnea/hypopnea index (P < 0.001). Ethnicity was no longer significantly associated with OSA severity when we adopted the World Health Organization criteria for obesity (≥25 and 30 kg/m² among Japanese descendants and white males, respectively). Japanese descendants with OSA have a lower BMI than white subjects of similar severity. However, ethnicity was not associated with OSA severity when an ethnical difference in obesity criteria was respected. Our data suggest that Japanese descendants are not predisposed to OSA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effects of sleep disorders on the quality of life (QOL) have been documented in the literature. Excessive sleepiness and altered circadian rhythms may negatively affect ability to learn, employment, and interpersonal relations, and directly degrade QOL. The objective of the present study was to evaluate the impact of obstructive sleep apnea syndrome of varying severity on QOL. The study was conducted on 1892 patients aged 18 years or older referred by a physician to the Sleep Institute, São Paulo, with complaints related to apnea (snoring, excessive daytime sleepiness, hyperarousal, and fatigue). They were submitted to overnight polysomnography for the diagnosis of sleep disorders from August 2005 through April 2006. The patients completed the Epworth Sleepiness Scale and QOL SF-36 sleep questionnaires. They were classified as non-physically active and physically active and not-sleepy and sleepy and the results of polysomnography were analyzed on the basis of the apnea hypopnea index (AHI). The apneic subjects showed a reduction in QOL which was proportional to severity. There was a significant decrease in all domains (physical functioning, role physical problems, bodily pain, general health perceptions, vitality, social functioning, emotional problems, general mental health) for apneics with AHI >30, who generally were sleepy and did not participate in physical activities (P < 0.05). The present study provides evidence that the impact of sleep disorders on QOL in apneics is not limited to excessive daytime sleepiness and that physical activity can contribute to reducing the symptoms. Thus, exercise should be considered as an adjunct interventional strategy in the management of obstructive sleep apnea syndrome.