952 resultados para angular correlation coefficient
Resumo:
Several Authors Have Discussed Recently the Limited Dependent Variable Regression Model with Serial Correlation Between Residuals. the Pseudo-Maximum Likelihood Estimators Obtained by Ignoring Serial Correlation Altogether, Have Been Shown to Be Consistent. We Present Alternative Pseudo-Maximum Likelihood Estimators Which Are Obtained by Ignoring Serial Correlation Only Selectively. Monte Carlo Experiments on a Model with First Order Serial Correlation Suggest That Our Alternative Estimators Have Substantially Lower Mean-Squared Errors in Medium Size and Small Samples, Especially When the Serial Correlation Coefficient Is High. the Same Experiments Also Suggest That the True Level of the Confidence Intervals Established with Our Estimators by Assuming Asymptotic Normality, Is Somewhat Lower Than the Intended Level. Although the Paper Focuses on Models with Only First Order Serial Correlation, the Generalization of the Proposed Approach to Serial Correlation of Higher Order Is Also Discussed Briefly.
Resumo:
The objective of the investigation who gave as result this work was to investigate the effectiveness of kinaesthetic motor imagery in the activation of the hemiplegic hand muscles following stroke. The experiment consisted of two random groups. Movements were measured after treatment. The participants were ten patients with hemiplegic hands (men who mean age was 74.4 years; mean time since stroke 3.05 months). All patients received three sessions of physical treatment based on an identical treatment protocol. Five patients were randomly assigned to an experimental group practising kinaesthetic motor imagery of a grasp using the 'lumbrical action' (experimental group). The others five (control group) followed a relaxation script. All the patients were then asked to grasp an object using the 'lumbrical action'. The grasps were recorded using an optoelectronic motion capture system. The magnitude of the extension of the index finger and the correlation of the angular displacement of the proximal phalangeal joints and the metacarpophalangeal joints were calculated. The movement time for the whole grip was calculated. The experimental group demonstrated higher extension in the index finger (p = < 0.01) and they had a higher correlation coefficient (0.99) than the control group (0.77) for the displacement of the proximal interphalangeal joint and the metacarpophalangeal joints. The movement time for the experimental group was faster, although the difference was not significant.
Resumo:
The correlation between the coronal source flux F_{S} and the total solar irradiance I_{TS} is re-evaluated in the light of an additional 5 years' data from the rising phase of solar cycle 23 and also by using cosmic ray fluxes detected at Earth. Tests on monthly averages show that the correlation with F_{S} deduced from the interplanetary magnetic field (correlation coefficient, r = 0.62) is highly significant (99.999%), but that there is insufficient data for the higher correlation with annual means (r = 0.80) to be considered significant. Anti-correlations between I_{TS} and cosmic ray fluxes are found in monthly data for all stations and geomagnetic rigidity cut-offs (r ranging from −0.63 to −0.74) and these have significance levels between 85% and 98%. In all cases, the t is poorest for the earliest data (i.e., prior to 1982). Excluding these data improves the anticorrelation with cosmic rays to r = −0:93 for one-year running means. Both the interplanetary magnetic field data and the cosmic ray fluxes indicate that the total solar irradiance lags behind the open solar flux with a delay that is estimated to have an optimum value of 2.8 months (and is within the uncertainty range 0.8-8.0 months at the 90% level).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In order to evaluate the relationship between the morphology of the upper lip and muscle activity in a sample of 38 subjects (17 males and 21 females) with Angle Class II division 1 malocclusions, cephalometric and electromyographic analyses were conducted. The sample was subdivided into either predominantly nose or mouth breathers. The individuals were evaluated at two different periods, with a 2 year interval. At the first observation, the subjects were 11 years to 14 years 11 months of age and at the second observation, 13 years 4 months to 16 years 6 months of age. Height and thickness of the upper lip were measured on lateral cephalograms with the aid of a digital pachymeter. For each individual, electromyographic records were obtained of the orbicularis oris superior muscle at rest and in a series of 12 movements. The electromyographic data were normalized as a function of amplitude, for achievement of the percentage value of each movement. Pearson and Spearman correlation tests were applied.The results showed some correlation between morphology and muscle function (at a confidence level of 95 per cent). However, as the values of the correlation coefficient (r) were too low to establish associations between variables, it was concluded that the dimensions of the upper lip are not correlated with muscle activity.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: Hand/wrist and dental radiographs are important for osteoporosis analysis in secondary hyperparathyroidism (SHPT). This study evaluated whether a correlation exists between the effects of the disease on the hands and jaws, and investigated the association between osteoporosis progression in the hands and parathyroid hormone (PTH) levels in chronic kidney disease (CKD) patients. Materials and methods: Four panoramic radiographic parameters (mental index, mandibular cortical index, trabecular bone pattern, and calcification/resorption) and four corresponding hand/wrist radiographic parameters (metacarpal cortical thickness, phalangeal cortical index, trabecular bone pattern, and calcification/resorption) were applied to investigate possible correlation between the effects of SHPT on the jaws and hands/wrists, by Spearman's correlation coefficient. PTH levels and the hand/wrist radiographic parameters were also tested by spearman's correlation coefficient (p < 0.05). The presence of brown tumors, vascular calcifications, and acroosteolysis on the hands was also evaluated. Results: Mandibular cortical index was strongly correlated with the phalangeal cortical index (p = 0.000). Phalangeal cortical index and trabecular bone pattern of hand/wrist correlated with PTH levels (0.002 and 0.000, respectively). Brown tumors occurred in four CKD patients, while both vascular calcifications and acroosteolysis were observed in 19 patients. Conclusion: There is a significant correlation between the morphological changes caused by secondary hyperparathyroidism in hand and jaw bones. The morphological status can be assessed using the mandibular cortical index, besides the phalangeal cortical index. The latter correlates well with parathyroid hormone levels of advanced chronic kidney disease. Clinical relevance: Panoramic images reveal morphological changes in the jaw bone, indicating likewise changes in the hand/wrist in severe secondary hyperparathyroidism. The severity of the bone changes may be a reflection of the parathyroid hormone levels in advanced chronic kidney disease. © 2012 Springer-Verlag.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Stroke is the most common neurological disease in adults that is associated with deglutition disorders. The presence of laryngeal sensitivity is very important in developing safe swallowing without risk of pulmonary complications. The aim of this study was to correlate laryngeal sensitivity with laryngeal penetration and tracheal aspiration after swallows of three food consistencies (puree, thickened liquid, and liquid) in poststroke individuals in the late phase. A cross-sectional clinical study was performed with 91 post-ischemic stroke individuals, with oropharyngeal dysphagia, who were in rehabilitation center treatment from 2009 to 2011. They had a mean age of 68.1 years and average time since injury was 22.6 months; 39 had injury to the right hemisphere and 52 had injury to the left hemisphere. All underwent fiberoptic endoscopic evaluation of swallowing and evaluation of laryngeal sensitivity by touching the tip of the endoscope to the arytenoids and aryepiglottic folds. The linear correlation coefficient of Spearman was applied to evaluate the correlation between laryngeal penetration and tracheal aspiration and the presence/absence of laryngeal sensitivity. There was a negative correlation between the observation of penetration and tracheal aspiration and laryngeal sensitivity, with all bolus consistencies (p < 0.001 for aspiration and p a parts per thousand currency sign 0.01 for penetration). The absence of laryngeal sensitivity determines the more frequent findings of penetration and tracheal aspiration. This sensory stimulus in the mucosa of the pharynx and larynx is an essential element for safe swallowing and its deficiency associated with altered motor activity can cause laryngeal penetration and aspiration in poststroke individuals regardless of food consistency.
Resumo:
The aim of this study was to evaluate the correlation of color change on bleaching tooth through delta E (ΔE) by the spectrophotometer Spectroshade (SS) and digital program Scanwhite (SW). Methods: 25 patient volunteers were recruited from Operative Dentistry at Universidad de Chile Dental School, between 18 to 30 years, with good oral hygiene. Exclusion criteria: Previous experienced tooth bleaching, anterior restorations, cervical lesions, pain dental, pregnant patient, stained teeth, malposition of the teeth and periodontal pathology. The bleaching was made in two sessions with three different bleaching systems which were randomly. The assessment of color change through ΔE was made on the two upper central incisors (N=50) by the SS and SW. The color in the same teeth were measured before (T0) and after (T1) of the bleaching treatment. Data were analyzed using test Spearman correlation coefficient (Rho) with a significant level of 95%. Results: The results showed a positive and significant correlation (0.676), with a statistically significant difference (p<0.05). Conclusion: There is correlation in the measurement of color change on bleaching tooth by SS and SW.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Ciências Ambientais - Sorocaba
Resumo:
CONTEXTUALIZAÇÃO: A biofotogrametria é uma técnica difundida na área da saúde e, apesar dos cuidados metodológicos, há distorções nas leituras angulares das imagens fotográficas. OBJETIVO: Mensurar o erro das medidas angulares em imagens fotográficas com diferentes resoluções digitais em um objeto com ângulos pré-demarcados. MÉTODOS: Utilizou-se uma esfera de borracha com 52 cm de circunferência. O objeto foi previamente demarcado com ângulos de 10º, 30º, 60º e 90º, e os registros fotográficos foram realizados com o eixo focal da câmera a três metros de distância e perpendicular ao objeto, sem utilização de zoom óptico e com resolução de 3, 5 e 10 Megapixels (Mp). Todos os registros fotográficos foram armazenados, e os valores angulares foram analisados por um experimentador previamente treinado, utilizando o programa ImageJ. As aferições das medidas foram realizadas duas vezes, com intervalo de 15 dias entre elas. Posteriormente, foram calculados os valores de acurácia, erro relativo e em graus, precisão e Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: Quando analisado o ângulo de 10º, a média da acurácia das medidas foi maior para os registros com resolução de 3 Mp em relação às resoluções de 5 e 10 Mp. O ICC foi considerado excelente para as três resoluções de imagem analisadas e, em relação aos ângulos analisados nos registros fotográficos, pôde-se verificar maior acurácia, menor erro relativo e em graus e maior precisão para o ângulo de 90º, independentemente da resolução da imagem. CONCLUSÃO: Os registros fotográficos realizados com a resolução de 3 Mp proporcionaram medidas de maiores valores de acurácia e precisão e menores valores de erro, sugerindo ser a resolução mais adequada para gerar imagem de ângulos de 10º e 30º.