957 resultados para Zero-dispersion wavelength


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We discuss an approximation for the dynamic charge response of nonlinear spin-1/2 Luttinger liquids in the limit of small momentum. Besides accounting for the broadening of the charge peak due to two-holon excitations, the nonlinearity of the dispersion gives rise to a two-spinon peak, which at zero temperature has an asymmetric line shape. At finite temperature the spin peak is broadened by diffusion. As an application, we discuss the density and temperature dependence of the Coulomb drag resistivity due to long-wavelength scattering between quantum wires.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Collision induced power jitter is examined in dispersion-managed wavelength division-multiplexed transmission systems. The power jitter causes ’ a serious problem for a singly-periodic dispersion managed line having almost zero average dispersion, which can be reduced by applying doubly-periodic dispersion management.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Collision-induced power jitter is theoretically and numerically examined in dispersion-managed wavelength-division-multiplexed optical soliton transmission systems. The variational method is mainly used to develop a time efficient jitter calculation approach. The power jitter causes a serious problem for a singly periodic dispersion managed line having almost zero average dispersion, which can be reduced by applying doubly periodic dispersion management.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Supercontinuum generation in ultra-long Raman fibre laser cavities is compared for a range of fibre dispersions in the anomalous and normal regimes. For normal dispersion improved performance and efficiency is achieved using dual wavelength pumping.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis presents theoretical investigation of three topics concerned with nonlinear optical pulse propagation in optical fibres. The techniques used are mathematical analysis and numerical modelling. Firstly, dispersion-managed (DM) solitons in fibre lines employing a weak dispersion map are analysed by means of a perturbation approach. In the case of small dispersion map strengths the average pulse dynamics is described by a perturbation approach (NLS) equation. Applying a perturbation theory, based on the Inverse Scattering Transform method, an analytic expression for the envelope of the DM soliton is derived. This expression correctly predicts the power enhancement arising from the dispersion management.Secondly, autosoliton transmission in DM fibre systems with periodical in-line deployment of nonlinear optical loop mirrors (NOLMs) is investigated. The use of in-line NOLMs is addressed as a general technique for all-optical passive 2R regeneration of return-to-zero data in high speed transmission system with strong dispersion management. By system optimisation, the feasibility of ultra-long single-channel and wavelength-division multiplexed data transmission at bit-rates ³ 40 Gbit s-1 in standard fibre-based systems is demonstrated. The tolerance limits of the results are defined.Thirdly, solutions of the NLS equation with gain and normal dispersion, that describes optical pulse propagation in an amplifying medium, are examined. A self-similar parabolic solution in the energy-containing core of the pulse is matched through Painlevé functions to the linear low-amplitude tails. The analysis provides a full description of the features of high-power pulses generated in an amplifying medium.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method of all-optical passive quasi-regeneration in transoceanic 40 Gbit/s return-to-zero transmission systems with strong dispersion management was described. The use of in-line nonlinear optical loop mirrors (NOLM) by the method was demonstrated. The quasi-regeneration of signals performed by NOLMs was found to improve the systems's performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

All-optical passive regeneration in 40 Gbit/s-based wavelength-division-multiplexed (WDM) dispersion-managed return-to-zero (RZ) transmission system was discussed. In-line nonlinear optical loop mirrors (NOLM) were used. A feasibility of 300 GHz-spaced two channel unlimited transmission and 150 GHz-spaced two channel 25000 km transmission over the standard fiber were found.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Supercontinuum generation in ultra-long Raman fibre laser cavities is compared for a range of fibre dispersions in the anomalous and normal regimes. For normal dispersion improved performance and efficiency is achieved using dual wavelength pumping.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We examine the impact of the fiber type and dispersion management on the performance of a 16 × 40 Gb/s dense wavelength-division-multiplexing nonreturn-to-zero transmission system. The transmission line is composed of G.652 or G.655 fiber with periodic dispersion compensation and hybrid Raman erbium-doped fiber amplifier amplification.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The turning point of the refractive index (RI) sensitivity based on the multimode microfiber (MMMF) in-line Mach–Zehnder interferometer (MZI) is observed. By tracking the resonant wavelength shift of the MZI generated between the HE11 and HE12 modes in the MMMF, the surrounding RI (SRI) could be detected. Theoretical analysis demonstrates that the RI sensitivity will reach ±∞ on either side of the turning point due to the group effective RI difference (퐺) approaching zero. Significantly, the positive sensitivity exists in a very wide fiber diameter range, while the negative sensitivity can be achieved in a narrow diameter range of only 0.3 μm. Meanwhile, the experimental sensitivities and variation trend at different diameters exhibit high consistency with the theoretical results. High RI sensitivity of 10777.8 nm/RIU (RI unit) at the fiber diameter of 4.6 μm and the RI around 1.3334 is realized. The discovery of the sensitivity turning points has great significance on trace detection due to the possibility of ultrahigh RI sensitivity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We study the statistics of optical data transmission in a noisy nonlinear fiber channel with a weak dispersion management and zero average dispersion. Applying analytical expressions for the output probability density functions both for a nonlinear channel and for a linear channel with additive and multiplicative noise we calculate in a closed form a lower bound estimate on the Shannon capacity for an arbitrary signal-to-noise ratio.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organic microcavity light-emitting diodes typically exhibit a blueshift of the emitting wavelength with increasing viewing angle. We have modeled the shift of the resonance wavelength for several metal mirrors. Eight metals (Al, Ag, Cr, Ti, Au, Ni, Pt, and Cu) have been considered as top or bottom mirrors, depending on their work functions. The model fully takes into account the dependence of the phase change that occurs on reflection on angle and wavelength for both s and p polarization, as well as on dispersion in the organic layers. Different contributions to the emission wavelength shift are discussed. The influence of the thickness of the bottom mirror and of the choice and thickness of the organic materials inside the cavity has been investigated. Based on the results obtained, guidelines for a choice of materials to reduce blueshift; are given. (C) 2002 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper determines the effects of post-trade opaqueness on market performance. We find that the degree of market transparency has important effects on market equilibria. In particular, we show that dealers operating in a transparent structure set regret-free prices at each period making zero expected profits in each of the two trading rounds, whereas in the opaque market dealers invest in acquiring information at the beginning of the trading day. Moreover, we obtain that if there is no trading activity in the first period, then market makers only change their quotes in the opaque market. Additionally, we show that trade disclosure increases the informational efficiency of transaction prices and reduces volatility. Finally, concerning welfare of market participants, we obtain ambiguous results. Keywords: Market microstructure, Post-trade transparency, Price experimentation, Price dispersion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal1.5 continuous wavelet transform (HAAR-CWT and BIOR1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 nm in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR1.5-CWT spectra, respectively. In order to compare the performance of HAAR-CWT and BIOR1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods.