1000 resultados para WATER NITROBENZENE
Resumo:
Lidocaine transfer across the water/1,2-dichloroethane and the water/nitrobenzene interfaces has been investigated by chronopotentiometry with linear current scanning and cyclic voltammetry. The irreversible hydrolysis occurring in the phase transfer of dicaine at the water/nitrobenzene interface is discussed.
Resumo:
Transfer behaviors across the water/nitrobenzene interface were studied for five choline derivatives by chronopotentiometry with linear current scanning, cyclic voltammetry and differential pulse voltammetry. The irreversible hydrolysis reactions coupled to the phase transfer of ions across the water/nitrobenzene interface were observed. The Gibbs energies of the transfer of choline derivatives show the effects of an additive constitution on hydrophobic property of the medicine.
Resumo:
The Research on Electroanalytical chemistry in China started mainly from the beginning of new China in 1949. It has already good basis and development nowadays. A review with references to the end of seventies has been published in "Reviews in Analytical Chemistry" 1) and in a book titled "Fifty years of Chinese Chemistry" edited by the Chinese Chemical Society in 1985 2). Since then more than thousand papers have been published, and it is impossible and also not necessary to describe all of them. This review only deals with the main progress of electroanalytical chemistry in China in recent years. Some new developed methodologies will be reviewed by S. Dong in the next article.
Resumo:
The transfer behavior of alkali motal ions K~+ and Na~+ across the interfaces of water/nitrobenzene and water/1, 2-dichloroethane facilitated by Triton X-100 is investigated by cyclic voltammetry with four electrodes. The equations of interfacial half-wave potential derived in terms of the mechanism proposed isverified by the experimental data and consistent with the practical △_0~wφ_p-pM curves.
Resumo:
The equation of the potential-current curve for the ion transfer across the liquid/liquid interface during the linear current scanning has been derived theoretically. A method to calculate the kinetics parameters for the ion transfer by the way of linear current scanning is presented. The transfer of TPAs~+ ions, which is a typical basic electrolyte ion usually used in liquld/liquid interface electrochemistry, was practically investigated at the water/nitrobenzene interface.
Resumo:
Electrochemical transfer behavier of the V~vMo_(11)-V_5~vMo_7 heteropolyanions at the water/nitrobenzene interface has been investigated by using cyclic voltammetry. The effect of the solution acidity on the transfer behavior and the stable pH range of heteropolyanions were observed. Mixed melybdovanadate anions are more stable than 12-molybdophosphoric acid, however, the stability of the former decreases with increasing number of vanadium atoms. The main transfer species within the "potential window" has t...
Resumo:
Mode of access: Internet.
Resumo:
In order to investigate the chromosomal genotoxicity of nitrobenzene and benzonitrile, we studied the induction of micronuclei (MN) by these test compounds in V79 cells, as well as effects on the formation and stability of microtubules and on motor protein functions. No cytotoxicity was seen in V79 cell cultures in terms of Neutral red uptake after 18 h treatment with up to 1 mM nitrobenzene or 1 mM benzonitrile. Subsequently, a concentration range up to 100 μM was used in the experiments on induction of MN. Both test compounds exhibit a weak, but definitely positive test result compared to the solvent (DMSO) control. Minimal effect concentrations of nitrobenzene and benzonitrile appeared as low as 0.01 μM, and no-effect-concentrations were between 0.001 and 0.005 μM. Clearly enhanced MN rates were found at 0.1 μM and higher. Both, nitrobenzene and benzonitrile, induced mostly kinetochor (CREST)-positive micronuclei, thus characterising the chromosomal effects as aneugenic. In cell-free assays, a slight effect on tubulin assembly was observed at 1 mM nitrobenzene without addition of DMSO. Higher concentrations (5 mM) led to secondary effects. In presence of 1% DMSO, nitrobenzene exerted no detectable effect on tubulin assembly up to the solubility limit in water of about 15 mM. For benzonitrile in presence of DMSO, a clear dose-response of inhibition of tubulin assembly at 37°C was seen above the no-effect-concentration of 2 mM, with an IC50 of 13 mM and protein denaturation starting above a level of about 20 mM. The nature of the effects of nitrobenzene and benzonitrile on the association of tubulin to form microtubules was confirmed by electron microscopy. Treatment by either 5 mM nitrobenzene or 13 mM benzonitrile plus 1% DMSO left the microtubular structure intact whereas 5 mM nitrobenzene, in absence of DMSO, led to irregular cluster formations. The experiments demonstrate that both nitrobenzene and benzonitrile, in millimolar concentration ranges, may lead to interference with tubulin assembly in a cell-free system. The functionality of the tubulin-kinesin motor protein system was assessed using the microtubule gliding assay. Nitrobenzene affected the gliding velocity in a concentration-dependent manner, starting at about 7.5 μM and reaching complete inhibition of motility at 30 μM, whereas benzonitrile up to 200 μM did not affect the kinesin-driven gliding velocity. The micronucleus assay data demonstrate a chromosomal endpoint of genotoxicity of nitrobenzene and benzonitrile. Aneugenic effects of both compounds occur at remarkably low concentrations, with lowest-effect-concentrations being 0.1 μM. This points to the relevance of interactions with the cellular spindle apparatus.
Resumo:
Facilitated proton transfer across the water/1,2-dichloroethane (DCE) interface supported on the tips of micro- and nano-pipets by o-phenanthroline (Phen) was studied by using cyclic voltammetry. The formed micro- and nano-liquid/liquid interfaces functioned as micro- and nano-electrodes under certain experimental conditions. The dependence of the half-wave potentials on the aqueous solutions acidities was studied and the ratio of association constants between Phen and proton in the aqueous and DCE phases was calculated by the method proposed by Matsuda et al.. The standard rate constant (k(0)) and the transfer coefficient (alpha) evaluated by using nano-pipets were equal to 0.183 +/- 0.054 cm/s and 0.70 +/- 0.09, respectively.
Resumo:
In this paper, we describe a simple procedure to make agar-gel microelectrodes by filling micropipettes. These microelectrodes were used to study K+ transfer across the agar-water \ 1,2-dichloroethane interface facilitated by dibenzo-18-crown-6 (DB18C6), and the transfer of tetraethylammonium (TEA(+)). The results observed were similar to those obtained at micro-liquid \ liquid interfaces. The effect of various amounts of agar in the aqueous phase was optimized and 3% agar was chosen based on the potential window and solidification time. The different shapes of micro-agar-gel electrodes were prepared in a similar way. The fabricated agar-gel microelectrodes obey the classical micro-disk steady-state current equation, which is different from the behavior of a normal micropipette filled with aqueous solution without silanization. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Hydrogenation of nitrobenzene can be catalyzed by the water-soluble catalyst PdCl2(TPPTS)(2) (TPPTS = tris(m-sulfonatophenyl)phosphine trisodium salt) under normal pressure at 65 degrees C in H2O/toluene biphasic solvent system. The exhibits higher catalytic activity and selectivity for the hydrogenation of aromatic nitrocompounds, compared with PdCl2(TPPTS)(2) or H2PtCl6 alone. The transmission electron micrographs demonstrate that the monometallic catalyst is composed of ultrafine palladium particles of almost uniform size while the particles of bimetallic catalyst are more widely distributed in size than those of the monometallic ones. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Simultaneous nitrobenzene and phenol wet air oxidation was investigated in a stainless autoclave at temperature range of 180-220 ° C and 1.0 MPa oxygen partial pressure. Compared with the single oxidation of nitrobenzene under the same conditions, the presence of phenol in the reaction media greatly improved the removal efficiency of nitrobenzene. The effect of temperature on the reaction was studied. Phenol was considered as a type of initiator in the nitrobenzene oxidation. © 2004 Elsevier Ltd. All rights reserved.
Resumo:
In order to investigate the chromosomal genotoxicity of nitrobenzene and benzonitrile, we studied the induction of micronuclei (MN) by these test compounds in V79 cells, as well as effects on the formation and stability of microtubules and on motor protein functions. No cytotoxicity was seen in V79 cell cultures in terms of Neutral red uptake after 18 h treatment with up to 1 mM nitrobenzene or 1 mM benzonitrile. Subsequently, a concentration range up to 100 muM was used in the experiments on induction of MN. Both test compounds exhibit a weak, but definitely positive test result compared to the solvent (DMSO) control. Minimal effect concentrations of nitrobenzene and benzonitrile appeared as low as 0.01 muM, and no-effect-concentrations were between 0.001 and 0.005 muM. Clearly enhanced MN rates were found at 0.1 muM and higher. Both, nitrobenzene and benzonitrile, induced mostly kinetochor (CREST)-positive micronuclei, thus characterising the chromosomal effects as aneugenic. In cell-free assays, a slight effect on tubulin assembly was observed at 1 mM nitrobenzene without addition of DMSO. Higher concentrations (5 mM) led to secondary effects. In presence of 1% DMSO, nitrobenzene exerted no detectable effect on tubulin assembly up to the solubility limit in water of about 15 mM. For benzonitrile in presence of DMSO, a clear dose-response of inhibition of tubulin assembly at 37degreesC was seen above the no-effect-concentration of 2 mM, with an IC50 of 13 mM and protein denaturation starting above a level of about 20 mM. The nature of the effects of nitrobenzene and benzonitrile on the association of tubulin to form microtubules was confirmed by electron microscopy. Treatment by either 5 mM nitrobenzene or 13 mM benzonitrile plus 1% DMSO left the microtubular structure intact whereas 5 mM nitrobenzene, in absence of DMSO, led to irregular cluster formations. The experiments demonstrate that both nitrobenzene and benzonitrile, in millimolar concentration ranges, may lead to interference with tubulin assembly in a cell-free system. The functionality of the tubulin-kinesin motor protein system was assessed using the microtubule gliding assay. Nitrobenzene affected the gliding velocity in a concentration-dependent manner, starting at about 7.5 muM and reaching complete inhibition of motility at 30 muM, whereas benzonitrile up to 200 muM did not affect the kinesin-driven gliding velocity. The micronucleus assay data demonstrate a chromosomal endpoint of genotoxicity of nitrobenzene and benzonitrile. Aneugenic effects of both compounds occur at remarkably low concentrations, with lowest-effect-concentrations being 0.1 muM. This points to the relevance of interactions with the cellular spindle apparatus.