955 resultados para Visual methods


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Visual estimates are generally used for counts of horn flies, Haematobia irritans (L.) and play an important role as an instrument to quantify fly populations in scientific studies. In this study, horn fly counts were performed on 30 Nelore steers in the municipality of Aracatuba, SP Brazil, from January to December 1998. Flies were counted weekly by two methods: the estimate method whereby estimates of the number of flies on one side of the animal are obtained by visual observation, and the filming method whereby images of flies from both sides of the animal are recorded with a video camera. The tape was then played on a videotape recorder coupled to a television and the flies were counted on the screen. Both methods showed variations in horn fly population density during the period studied. However, significant differences (p < 0.05) were observed between the two methods with the filming method permitting the visualization of a larger number of flies than the estimate method. In addition, the filming method permitted safe and reliable counts hours after the images were taken, with the advantage that the tape can serve as an archive for random re-counts. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Driver and Pedestrian Research, Washington, D.C.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"C00-2118-0048."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis is an exploration of the organisation and functioning of the human visual system using the non-invasive functional imaging modality magnetoencephalography (MEG). Chapters one and two provide an introduction to the ‘human visual system and magnetoencephalographic methodologies. These chapters subsequently describe the methods by which MEG can be used to measure neuronal activity from the visual cortex. Chapter three describes the development and implementation of novel analytical tools; including beamforming based analyses, spectrographic movies and an optimisation of group imaging methods. Chapter four focuses on the use of established and contemporary analytical tools in the investigation of visual function. This is initiated with an investigation of visually evoked and induced responses; covering visual evoked potentials (VEPs) and event related synchronisation/desynchronisation (ERS/ERD). Chapter five describes the employment of novel methods in the investigation of cortical contrast response and demonstrates distinct contrast response functions in striate and extra-striate regions of visual cortex. Chapter six use synthetic aperture magnetometry (SAM) to investigate the phenomena of visual cortical gamma oscillations in response to various visual stimuli; concluding that pattern is central to its generation and that it increases in amplitude linearly as a function of stimulus contrast, consistent with results from invasive electrode studies in the macaque monkey. Chapter seven describes the use of driven visual stimuli and tuned SAM methods in a pilot study of retinotopic mapping using MEG; finding that activity in the primary visual cortex can be distinguished in four quadrants and two eccentricities of the visual field. Chapter eight is a novel implementation of the SAM beamforming method in the investigation of a subject with migraine visual aura; the method reveals desynchronisation of the alpha and gamma frequency bands in occipital and temporal regions contralateral to observed visual abnormalities. The final chapter is a summary of main conclusions and suggested further work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetic Retinopathy (DR) is a complication of diabetes that can lead to blindness if not readily discovered. Automated screening algorithms have the potential to improve identification of patients who need further medical attention. However, the identification of lesions must be accurate to be useful for clinical application. The bag-of-visual-words (BoVW) algorithm employs a maximum-margin classifier in a flexible framework that is able to detect the most common DR-related lesions such as microaneurysms, cotton-wool spots and hard exudates. BoVW allows to bypass the need for pre- and post-processing of the retinographic images, as well as the need of specific ad hoc techniques for identification of each type of lesion. An extensive evaluation of the BoVW model, using three large retinograph datasets (DR1, DR2 and Messidor) with different resolution and collected by different healthcare personnel, was performed. The results demonstrate that the BoVW classification approach can identify different lesions within an image without having to utilize different algorithms for each lesion reducing processing time and providing a more flexible diagnostic system. Our BoVW scheme is based on sparse low-level feature detection with a Speeded-Up Robust Features (SURF) local descriptor, and mid-level features based on semi-soft coding with max pooling. The best BoVW representation for retinal image classification was an area under the receiver operating characteristic curve (AUC-ROC) of 97.8% (exudates) and 93.5% (red lesions), applying a cross-dataset validation protocol. To assess the accuracy for detecting cases that require referral within one year, the sparse extraction technique associated with semi-soft coding and max pooling obtained an AUC of 94.2 ± 2.0%, outperforming current methods. Those results indicate that, for retinal image classification tasks in clinical practice, BoVW is equal and, in some instances, surpasses results obtained using dense detection (widely believed to be the best choice in many vision problems) for the low-level descriptors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To analyze the effects of 100 mg of sildenafil citrate (Viagra®) on the retrobulbar circulation and visual field. Methods: A double masked, placebo controlled study was conducted in 10 males with a mean age of 27.7 + 5.68 years. The right eye of each volunteer underwent orbital color Doppler imaging and automated perimetry (Humphrey, program 30-2, Full-Threshold Strategy) at 3 occasions: baseline, 1 hour after placebo and 1 hour after 100 mg of sildenafil. The foveal threshold and the mean deviation (MD) were analyzed by automated perimetry on the three occasions. Color Doppler imaging allowed the measurement of the peak systolic velocity (PSV), end diastolic velocity (EDV) and Pourcelot index (PI) in the central retinal artery and ophthalmic artery. Results: The foveal threshold and the mean deviation did not show a significant change following the administration of sildenafil. The ophthalmic artery peak systolic velocity and end diastolic velocity significantly increased after the administration of sildenafil (p<0.001). The hemodynamic parameters in the central retinal artery and the ophthalmic artery PI did not significantly change. Conclusions: Sildefanil citrate increased the blood flow velocities in the ophthalmic artery in normal subjects, with no significant changes in the foveal threshold and mean deviation in the automated perimetry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To verify perceptions and conduct of students with visual impairment regarding devices and equipment utilized in schooling process. METHODS: A transversal descriptive study on a population of 12-year-old or older students in schooling process, affected by congenital or acquired visual impairment, inserted in the government teaching system of Campinas during the year 2000. An interview quiz, created based on an exploratory study was applied. RESULTS: A group of 26 students, 46% of them with low vision and 53.8% affected by blindness was obtained. Most of the students were from fundamental teaching courses (65.4%), studying in schools with classrooms provided with devices (73.1%). Among the resources used in reading and writing activities, 94.1% of the students reported they used the Braille system and 81.8% reported that the reading subject was dictated by a colleague. Most of the students with low vision wore glasses (91.7%), and 33.3% utilized a magnifying glass as optical devices. Among the non-optical devices, the most common were the environmental ones, getting closer to the blackboard (75.0%) and to the window (66.7%) for better lighting. CONCLUSIONS: It became evident that students with low vision eye-sight made use of devices meant for bearers of blindness, such as applying the Braille system. A reduced number of low vision students making use of optical and non-optical devices applicable to their problems were observed, indicating a probable unawareness of their visual potential and the appropriate devices to improve efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To characterize the behavior of premature newborns in the first year of chronological age. METHODS: This is a cross-sectional descriptive study, bound to a longitudinal study titled: Comparison of visual behavior on the first quarter of year of life of premature nursling born at two maternities of Recife/PE. The sample was composed by 52 premature newborns selected from June, 2007 to June, 2008 from the Maternity of the Federal University of Pernambuco (UFPE). Biological, socioeconomic and demographic data was collected through medical records and interviews with progeny. Newborns were evaluated by the Assessment Guide of Visual Ability in Infants. RESULTS: Most of the newborns were male at a gestational period between 33 weeks and 36 weeks and 6 days, showed a good visual behavior development for the age researched, and most of the families showed good socioeconomical and demographic profile. Besides, it was possible to detect ocular signs in 19% of sample, that were referred to an Ophthalmology Service. CONCLUSION: This study results point out the method like an important key in the early detection and visual screening for premature nursling since the first month of life and it led us to believe that clinical view for occupational therapy intervention must be focused not only on biological risks but also at the influence environment in newborn performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física