969 resultados para Vein graft


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The long-term incidence of stent thrombosis (ST) and complications after sirolimus-eluting stents (SES) implantation is still a matter of debate. METHOD: We conducted a systematic follow-up on the day of their 5-year SES implantation anniversary, in a series of consecutive real-world patients treated with a SES. The use of SES implantation was not restricted to "on-label" indications, and target lesions included in-stent restenosis, vein graft, left main stem locations, bifurcations, and long lesions. The Academic Research Consortium criteria were used for ST classification. RESULTS: Three hundred fifty consecutive patients were treated with SES between April and December 2002 in 3 Swiss hospitals. Mean age was 63 +/- 6 years, 78% were men, 20% presented with acute coronary syndrome, and 19% were patients with diabetes. Five-year follow-up was obtained in 98% of eligible patients. Stent thrombosis had occurred in 12 patients (3.6%) [definite 6 (1.8%), probable 1 (0.3%) and possible 5 (1.5%)]. Eighty-one percent of the population was free of complications. Major adverse cardiac events occurred in 74 (21%) patients and were as follows: cardiac death 3%, noncardiac death 4%, myocardial infarction 2%, target lesion revascularization 8%, non-target lesion revascularization target vessel revascularization 3%, coronary artery bypass graft 2%. Non-TVR was performed in 8%. CONCLUSION: Our data confirm the good long-term outcome of patients treated with SES. The incidence of complications and sub acute thrombosis at 5 years in routine clinical practice reproduces the results of prospective randomized trials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Human saphenous vein grafts are one of the salvage bypass conduits when endovascular procedures are not feasible or fail. Understanding the remodeling process that venous grafts undergo during exposure to arterial conditions is crucial to improve their patency, which is often compromised by intimal hyperplasia. The precise role of hemodynamic forces such as shear stress and arterial pressure in this remodeling is not fully characterized. The aim of this study was to determine the involvement of arterial shear stress and pressure on vein wall remodeling and to unravel the underlying molecular mechanisms. METHODS: An ex vivo vein support system was modified for chronic (up to 1 week), pulsatile perfusion of human saphenous veins under controlled conditions that permitted the separate control of arterial shear stress and different arterial pressure (7 mm Hg or 70 mm Hg). RESULTS: Veins perfused for 7 days under high pressure (70 mm Hg) underwent significant development of a neointima compared with veins exposed to low pressure (7 mm Hg). These structural changes were associated with altered expression of several molecular markers. Exposure to an arterial shear stress under low pressure increased the expression of matrix metalloproteinase (MMP)-2 and MMP-9 and tissue inhibitor of metalloproteinase (TIMP)-1 at the transcript, protein, and activity levels. This increase was enhanced by high pressure, which also increased TIMP-2 protein expression despite decreased levels of the cognate transcript. In contrast, the expression of plasminogen activator inhibitor-1 increased with shear stress but was not modified by pressure. Levels of the venous marker Eph-B4 were decreased under arterial shear stress, and levels of the arterial marker Ephrin-B2 were downregulated under high-pressure conditions. CONCLUSIONS: This model is a valuable tool to identify the role of hemodynamic forces and to decipher the molecular mechanisms leading to failure of human saphenous vein grafts. Under ex vivo conditions, arterial perfusion is sufficient to activate the remodeling of human veins, a change that is associated with the loss of specific vein markers. Elevation of pressure generates intimal hyperplasia, even though veins do not acquire arterial markers. CLINICAL RELEVANCE: The pathological remodeling of the venous wall, which leads to stenosis and ultimately graft failure, is the main limiting factor of human saphenous vein graft bypass. This remodeling is due to the hemodynamic adaptation of the vein to the arterial environment and cannot be prevented by conventional therapy. To develop a more targeted therapy, a better understanding of the molecular mechanisms involved in intimal hyperplasia is essential, which requires the development of ex vivo models of chronic perfusion of human veins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim. Autologous vein (AV) is sometimes not suitable or present for a vascular restoration. Homologous vein preserved in glutaraldehyde may be an alternative to AV, but little is yet known about this graft and its healing process after implantation in arteries. The purpose of this study was to compare the initial healing process of glutaraldehyde-tanned homologous venous grafts (group 1) with fresh autologous venous grafts (group 2), at 4 or 15 days.Methods. Forty Norfolk rabbits were allocated in 2 groups of 20 animals each. The grafts was interposed in the infra-renal aorta of the rabbit. Anastomotic tensile strength (TS), hydroxyproline (HP) determination, and histology (HA) were performed.Results. TS increased in both groups, from the 4th to 15th day, (p < 0.01) in both proximal (G1: from 364.5 &PLUSMN; 98.3 g to 491.8 &PLUSMN; 107.3 g; G2: from 366.26 &PLUSMN; 85.15 g to 518.46 &PLUSMN; 82.79 g) and distal anastomosis (GI: from 363.53 &PLUSMN; 96.26 g to 507.32 &PLUSMN; 91.01 g; G2: from 352.30 &PLUSMN; 102.41 g to 528.67 &PLUSMN; 48.58 g), with no difference between the groups. HP did not change (p > 0.10) in this same period and was similar in both groups, in the proximal (GI: from 677.99 +/- 153.98 mug/100 mg to 914.92 +/- 459.83 mug/100 mg; G2: from 668.65 +/- 170.28 mug/100 mg to 669.46 +/- 319.80 mug/100 mg) as well as in the distal anastomosis (G1:from 740.07 +/- 213.53 mug/100 mg to 923.52 +/- 270.57 mug/100 mg; G2: from 737.66 +/- 266.76 mug/100 mg to 707.68 +/- 171.25 mug/100 mg). Initial inflammatory and reparative features of the anastomosis were similar in both groups.Conclusion. We can conclude that the healing process of the glutaraldehyde-tanned homologous vein graft was similar to that of the fresh autologous venous graft.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O emprego da trombectomia na angioplastia primária demonstra bons resultados clínicos e angiográficos imediatos, por meio de redução da embolização distal e do fenômeno do no-reflow e otimização da perfusão miocárdica. Essa técnica, principalmente usada em artérias coronárias, em raras oportunidades é descrita quando empregada em pontes de safena aortocoronarianas. Relatamos o caso de um paciente de 67 anos com infarto agudo do miocárdio relacionado a oclusão de ponte de safena e submetido a trombectomia com bons resultados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Retrospective evaluation of cases of limb replantation after avulsion injuries. Evaluation of the techniques and tactics used, that contributed to success and good functional results. Methods: Forty-three patients' records were assessed. All the cases had been submitted to limb replantation after avulsion injuries. Results: The majority of the cases were young men. The most common injury was to the thumbs. The surgical techniques and tactics used were: nerve grafting, vein grafting, transposition of the digital vessels, limb shortening, and heterotopic replantation. The most commonly used technique was vein graft. The limb survival rate was high (93%), as was patient satisfaction. Conclusion: Replantation after avulsion injury depends on the correct diagnosis of the limb viability and the use of appropriate surgical techniques and tactics for each case. The experience of the team of surgeons and a good hospital structure are essential for good results. There are few articles in medical literature about the indications, techniques and results of limb replantation after avulsion injuries. We believe that this retrospective evaluation can bring new information and contributions to the correct management of this highly complex situation. Level of evidence IV, Case Series.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The remarkable patency of internal mammary artery (MA) grafts compared to saphenous vein (SV) grafts has been related to different biological properties of the two blood vessels. We examined whether proliferation and apoptosis of vascular smooth muscle cells (VSMC) from human coronary artery bypass vessels differ according to patency rates. METHODS AND RESULTS: Proliferation rates to serum or platelet-derived growth factor (PDGF)-BB were lower in VSMC from MA than SV. Surface expression of PDGF beta-receptor was slightly lower, while that of alpha-receptor was slightly higher in MA than SV. Cell cycle distribution, expression of cyclin E, cdk2, p21, p27, p57, and cdk2 kinase activity were identical in PDGF-BB-stimulated cells from MA and SV. However, apoptosis rates were higher in MA than SV determined by lactate dehydrogenase release, DNA fragmentation, and Hoechst 33258 staining. Moreover, caspase inhibitors (Z-VAD-fmk, Boc-D-fmk) abrogated the different proliferation rates of VSMC from MA versus SV. Western blotting and GSK3-beta kinase assay revealed lower Akt activity in VSMC from MA versus SV, while total Akt expression was identical. Adenoviral transduction of a constitutively active Akt mutant abrogated the different proliferation rates of VSMC from MA versus SV. CONCLUSIONS: Higher apoptosis rates due to lower Akt activity rather than different cell cycle regulation account for the lower proliferation of VSMC from MA as compared to SV. VSMC apoptosis may protect MA from bypass graft disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method by which to overcome the clinical symptoms of atherosclerosis is the insertion of a graft to bypass an artery blocked or impeded by plaque. However, there may be insufficient autologous mammary artery for multiple or repeat bypass, saphenous vein may have varicose degenerative alterations that can lead to aneurysm in high-pressure sites, and small-caliber synthetic grafts are prone to thrombus induction and occlusion. Therefore, the aim of the present study was to develop an artificial blood conduit of any required length and diameter from the cells of the host for autologous transplantation. Silastic tubing, of variable length and diameter, was inserted into the peritoneal cavity of rats or rabbits. By 2 weeks, it had become covered by several layers of myofibroblasts, collagen matrix, and a single layer of mesothelium. The Silastic tubing was removed from the harvested implants, and the tube of living tissue was everted such that it now resembled a blood vessel with an inner lining of nonthrombotic mesothelial cells (the intima), with a media of smooth muscle-like cells (myofibroblasts), collagen, and elastin, and with an outer collagenous adventitia. The tube of tissue (10 to 20 mm long) was successfully grafted by end-to-end anastomoses into the severed carotid artery or abdominal aorta of the same animal in which they were grown. The transplant remained patent for at least 4 months and developed structures resembling elastic lamellae. The myofibroblasts gained a higher volume fraction of myofilaments and became responsive to contractile agonists, similar to the vessel into which they had been grafted. It is suggested that these nonthrombogenic tubes of living tissue, grown in the peritoneal cavity of the host, may be developed as autologous coronary artery bypass grafts or as arteriovenous access fistulae for hemodialysis patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine 30 day mortality, long term survival, and recurrent cardiac events after coronary artery bypass graft (CABG) in a population. Design: Follow up study of patients prospectively entered on to a cardiothoracic surgical database. Record linkages were used to obtain data on readmissions and deaths. Patients: 8910 patients undergoing isolated first CABG between 1980 and 1993 in Western Australia. Main outcome measures: 30 day and long term survival, readmission for cardiac event (acute myocardial infarction, unstable angina, percutaneous transluminal coronary angioplasty or reoperative CABG). Results: There were 3072 deaths to mid 1999. 30 day and long term survival were significantly better in patients treated in the first five years than during the following decade. The age of the patients, proportion of female patients, and number of grafts increased over time. An urgent procedure (odds ratio 3.3), older age (9% per year) and female sex (odds ratio 1.5) were associated with increased risk for 30 day mortality, while age (7% per year) and a recent myocardial infarction (odds ratio 1.16) influenced long term survival. Internal mammary artery grafts were followed by better short and long term survival, though there was an obvious selection bias in favour of younger male patients. Conclusions: This study shows worsening crude mortality at 30 days after CABG from the mid 1980s, associated with the inclusion of higher risk patients. Older age, an acute myocardial infarction in the year before surgery, and the use of sephenous vein grafts only were associated with poorer long term survival and greater risk of a recurrent cardiac event. Female sex predicted recurrent events but not long term survival.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Purpose. Late portal vein thrombosis (PVT) can be extremely well tolerated, although portal hypertension and other consequences of the long-term deprivation of portal inflow to the graft may be hazardous, especially in young children. Recently, the ""Rex shunt"" has been used successfully to treat these patients. We now report the initial experience with this novel technique. Methods. A 3-year-old girl with PVT at 7 months after whole organ cadaveric liver transplant displayed portal hypertension with an episode of gastrointestinal bleeding, requiring a mesenteric-portal surgical shunt (""Rex shunt"") using a left internal jugular vein autograft. Results. Upon current follow-up of 6 months, postoperative Doppler ultrasound confirmed shunt patency. Endoscopic status was significantly improved after surgery with resolution of portal hypertension. There was no recurrence of bleeding. Conclusions. The mesenteric-portal shunt (""Rex shunt""), using a left internal jugular vein autograft, should be considered for children with late PVT after liver transplantation. Although this is an initial experience, we may conclude that this technique is feasible, with great potential benefits and low risks for these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and compare the benefits of endoscopic saphenous vein harvesting (EVH) with the traditional incision technique (TIT) for coronary artery bypass grafting (CABG) in respect to the technical procedure and clinical outcome. In a prospective nonrandomized, case-matched study the greater saphenous vein was harvested for CABG in 22 patients using the endoscopic technique and in 18 patients with the traditional method. Comparisons were made for the operating time, length of incision and vein harvested, graft quality, postoperative complications, and pain assessment. Patient demographics were well matched. EVH required smaller incisions than did the TIT (10.5 +/- 6.6 vs. 31.2 +/- 7.8 cm, respectively; p < 0.0001). Harvest time and vein quality were comparable in the two groups. Total vein operating time was shorter following the endoscopic technique (60 +/- 24 vs. 100 +/- 35 minutes, respectively; p < 0.0001). EVH had fewer complications (NS), and postoperative pain was significantly less (p = 0.0034). The major advantages of endoscopic vein harvesting are a significant reduction of postoperative pain and strikingly better cosmetic results. Wound complications seem to be less frequent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.