978 resultados para Ultrasonic NDE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron-electron scattering contribution to the ultrasonic attenuation in potassium at low temperatures is evaluated using the Landau Fermi liquid theory. The scattering function is evaluated using the approximation suggested by MacDonald and Geldart. The results are compared with theoretically evaluated electron-phonon scattering contributions. The results show that the electron-electron scattering contribution is of the same order as the electron-phonon scattering contribution in the 2–5 K range. Below 2 K the electron-electron scattering predominates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise measurements of the ultrasonic velocities and thermal expansivities of amorphous Se80Te20 and Se90Te10 alloys are reported near the glass transition. The samples are produced by liquid quenching. The longitudinal and transverse velocities are measured at 10 MHz frequency using the McSkimin pulse superposition technique. The thermal expansivities,agr, are measured using a three-terminal capacitance bridge. Theagr-values show a sharp maximum near the glass transition temperature,T g. The ultrasonic velocities also show a large temperature derivative, dV/dT nearT g. The data are discussed in terms of existing theories of the glass transition. The continuous change inagr shows that the glass transition is not a first-order transition, as suggested by some theories. The samples are found to be deformed by small loads nearT g. The ultrasonic velocities and dV/dT have contributions arising from this deformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the structural reliability of bridges, an accurate and cost effective Non-Destructive Evaluation (NDE) technology is required to ensure their safe and reliable operation. Over 60% of the Australian National Highway System is prestressed concrete (PSC) bridges according to the Bureau of Transport and Communication Economics (1997). Most of the in-service bridges are more than 30 years old and may experience a heavier traffic load than their original intended level. Use of Ultrasonic waves is continuously increasing for (NDE) and Structural Health Monitoring (SHM) in civil, aerospace, electrical, mechanical applications. Ultrasonic Lamb waves are becoming more popular for NDE because it can propagate long distance and reach hidden regions with less energy loses. The purpose of this study is to numerically quantify prestress force (PSF) of (PSC) beam using the fundamental theory of acoustic-elasticity. A three-dimension finite element modelling approach is set up to perform parametric studies in order to better understand how the lamb wave propagation in PSC beam is affected by changing in the PSF level. Results from acoustic-elastic measurement on prestressed beam are presented, showing the feasibility of the lamb wave for PSF evaluation in PSC bridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise measurements of 10 MHz frequency longitudinal and shear wave velocities are reported in amorphous SeGe alloys near their glass transition temperature T g . There is a sharp decrease of the velocities near T g , but the reduction in velocities appears smaller than expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic velocities in aqueous solutions of some metal acetates, monochloroacelates and trichloroacetates, and the respective acids have been measured at 1 MHz frequency using the pulse technique. The ultrsonic velocity, adiabatic compressibility and apperent molal compressibility were measured as a function of concentration. The apparent molal compressibility values at infinite dilution were calculated and used to determine the hydration numbers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise measurements of the ultrasonic velocities and thermal expansivities of amorphous Se80Te20 and Se90Te10 alloys are reported near the glass transition. The samples are produced by liquid quenching. The longitudinal and transverse velocities are measured at 10 MHz frequency using the McSkimin pulse superposition technique. The thermal expansivities,agr, are measured using a three-terminal capacitance bridge. Theagr-values show a sharp maximum near the glass transition temperature,T g. The ultrasonic velocities also show a large temperature derivative, dV/dT nearT g. The data are discussed in terms of existing theories of the glass transition. The continuous change inagr shows that the glass transition is not a first-order transition, as suggested by some theories. The samples are found to be deformed by small loads nearT g. The ultrasonic velocities and dV/dT have contributions arising from this deformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The copolymers, poly(methyl methacrylate-co-methyl acrylate) (PMMAMA), poly(methyl methacrylate-co-ethyl acrylate) (PMMAEA) and poly(methyl methacrylate-co-butyl acrylate) (PMMABA), of different compositions were synthesized and characterized. The effect of alkyl acrylate content, alkyl group substituents and solvents on the ultrasonic degradation of these copolymers was studied. A model based on continuous distribution kinetics was used to study the kinetics of degradation. The rate coefficients were obtained by fitting the experimental data with the model. The linear dependence of the rate coefficients on the logarithm of the vapor pressure of the solvent indicated that vapor pressure is the crucial parameter that controls the degradation process. The rate of degradation increases with an increase in the alkyl acrylate content. At any particular copolymer composition, the rate of degradation follows the order: PMMAMA > PMMAEA > PMMABA. It was observed that the degradation rate coefficient varies linearly with the mole percentage of the alkyl acrylate in the copolymer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the nonlocal elasticity theory has been incorporated into classical Euler-Bernoulli rod model to capture unique features of the nanorods under the umbrella of continuum mechanics theory. The strong effect of the nonlocal scale has been obtained which leads to substantially different wave behaviors of nanorods from those of macroscopic rods. Nonlocal Euler-Bernoulli bar model is developed for nanorods. Explicit expressions are derived for wavenumbers and wave speeds of nanorods. The analysis shows that the wave characteristics are highly over estimated by the classical rod model, which ignores the effect of small-length scale. The studies also shows that the nonlocal scale parameter introduces certain band gap region in axial wave mode where no wave propagation occurs. This is manifested in the spectrum cures as the region where the wavenumber tends to infinite (or wave speed tends to zero). The results can provide useful guidance for the study and design of the next generation of nanodevices that make use of the wave propagation properties of single-walled carbon nanotubes. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies an ultrasonic wave dispersion characteristics of a nanorod. Nonlocal strain gradient models (both second and fourth order) are introduced to analyze the ultrasonic wave behavior in nanorod. Explicit expressions are derived for wave numbers and the wave speeds of the nanorod. The analysis shows that the fourth order strain gradient model gives approximate results over the second order strain gradient model for dynamic analysis. The second order strain gradient model gives a critical wave number at certain wave frequency, where the wave speeds are zero. A relation among the number of waves along the nanorod, the nonlocal scaling parameter (e(0)a), and the length of the nanorod is obtained from the nonlocal second order strain gradient model. The ultrasonic wave characteristics of the nanorod obtained from the nonlocal strain gradient models are compared with the classical continuum model. The dynamic response behavior of nanorods is explained from both the strain gradient models. The effect of e(0)a on the ultrasonic wave behavior of the nanorods is also observed. (C) 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A working model is given for the rate of ultrasonic emulsification, considering the dispersion at the interface (area A) and the coagulations in the volume V of the emulsion. A bimolecular coagulation leads to the equation c=c∞tanh bt;c∞=(Aα/Vβ)1/2;b=(Aαβ/V)1/2 while a monomolecular coagulation gives c=c∞{1-exp (-at)};c∞=Aα/Vβ;a=β. The experiments on the dependence of c∞, a and b upon A and V favour the bimolecular coagulation. The results are satisfactorily explained on general theoretical grounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental setup suitable for a quantitative study of the ultrasonic emulsification is described. The methods of producing a well-defined sound field, of measuring the sound intensity, and of following the emulsion concentration are discussed critically. The good reproducibility resulting from the improved experimental techniques is examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a pulse method the ultrasonic absorption has been studied in the frequency range of 2 to 10 Mc/s in dilute aqueous solutions of nitrogen tetroxide gas at room temperature. The absorption peaks (αλ vs frequency) observed in this study are attributed to the ionic dissociation reaction of the nitrous acid into its constituent ions. The rate constants of the forward and backward reactions are calculated using the theory of Tabuchi. The variation of the logarithm of the rate constant of the bimolecular ionic reaction, namely, log10 kb, with the square root of ionic strength qualitatively follows Brönsted's theory for ionic reactions in solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultrasonic degradation of poly (styrene-co-methyl methacrylate) (SMMA), poly (styrene-co-ethyl methacrylate) (SEMA) and poly (styrene-co-butyl methacrylate) (SBMA) copolymers of different compositions was studied. The copolymers were synthesized and NMR spectroscopy was used to determine the composition, and the glass transition temperatures were determined by DSC. The reactivity ratios were determined by the Kelen-Tudos method and it indicated that the copolymers were random. The effect of solvent, temperature and copolymer composition on the ultrasonic degradation rate of these copolymers was investigated. A model based on continuous distribution kinetics was employed to study the degradation kinetics. The degradation rate coefficients of the copolymers decreased with an increase in the styrene content in the copolymer. At any particular copolymer composition the rate of degradation follows the order: SBMA >SEMA > SMMA. Thermogravimetric analysis (TGA) of the copolymers was carried in order to assess their thermal stability. The same order of degradation was observed for the thermal degradation of the copolymers as that observed for ultrasonic degradation. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic absorption has been studied by the pulse technique in the binary mixtures of acetic acid in water, methyl and ethyl alcohols and covers a range of 2 to 26 Mc/s. The mixtures are studied from 0 to 100% by weight of the acid. In all the three mixtures, two relaxation processes are observed, the first occurring below the frequency range of the study. The second one occurs near 20 Mc/s in the acid-water mixtures and at much higher frequencies in the other cases. It is qualitatively explained that the monomer-dimer reaction of the acetic acid giving a relaxation near 1 Mc/s has shifted to a higher frequency when mixed in a solvent thus giving rise to a second relaxation in the mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the pulse method in the range of 2 to 26Mc's the ultrasonic absorption, velocity and the adiabatic compressibility have been studied in eleven aqueous acetate solutions up to a concentration of 1 mole/litre. The substances studied are the acetates of lithium, sodium, potassium, ammonium, magnesium, calcium, strontium, barium, zinc, cadmium and lead. Absorption in mercuric acetate has been studied only at 2 and 6 Mc/s. Two regions of relaxation are noticed, one below 10 Mc/s and the other between 10 and 26 Mc/s. The first relaxation is ascribed to the dissociation reaction of the salt and the second one to the monomerdimer reaction of the acetic acid formed by the hydrolysis of the salt in water.