938 resultados para ULTRASOUND-GUIDED BIOPSY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of lineage of oocytes donors on the number and quality of oocytes obtained through ultrasound-guided follicular aspiration in Nellore breed cows derived from two lineages of bulls (Karvadi; K and Taj-Mahal; T). Both maternal (Km and Tm) and paternal (Kp and Tp) lineages, as well as their combinations were investigated. Oocyte aspirations were repeatedly performed with an aspiration interval of 15 days in 56 donor females. Recovered cumulus oocyte-complexes (COCs) were counted, morphologically examined and classified into seven categories (grades from I to VII) according to the number of layers of the cumulus oocyte and cytoplasm appearance. The mean number of oocytes retrieved from donors of lineage Tp-Tm was significantly higher (28.23±1.92, P<0.05) than those obtained from lineages Kp-Tm, Kp-Km, and Tp-Km (21.34±1.32, 21.28±1.73, and 16.72±1.31, respectively). There was no significant difference in the mean number of recovered oocytes between donors of lineages Kp-Km and Kp-Tm, whereas animals of lineage Tp-Km yielded the lowest number of oocytes. Higher mean number of grade III oocytes was recovered from donors of lineage Kp than lineage Tp (10.11±0.66 versus 8.79±0.58, respectively), with more grade III oocytes being obtained in both lineages as compared to the others. Paternal lineage did not influence the quality of recovered oocytes in any other category, but both Kp and Tp yielded a great mean number of oocytes graded as I, II, and III (3.14±0.21; 4.93±0.33, and 10.11±0.66 versus 3.19±0.21, 5.59±0.44, and 8.79±0.58, respectively) than those classified as IV, V, VI, and VII. However, when considering the data from the maternal lineage significantly more oocytes (P<0.05) of grade I, II and III were obtained from Taj-Mahal (11.67 ± 0.67, 5.9±0.42 and 3.64±0.25, respectively) than for lineage Karvadi, with similar results for oocytes of grades IV, V, VI, and VII. Similarly to the paternal lineage, the number of oocytes of grade III was superior (P<0.05) when compared to other categories for both lineages. In conclusion, we demonstrate here a direct influence of lineage of oocyte donor on the production and quality of oocytes obtained through ultrasound-guided follicular aspiration in Nellore cows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Performing spermatic cord block for scrotal surgery avoids the potential risks of neuraxial and general anaesthesia and provides long-lasting postoperative analgesia. A blindly performed block is often inefficient and bears its own potential risks (intravascular injection of local anaesthetics, haematoma formation and perforation of the deferent duct). The use of ultrasound may help to overcome these disadvantages. The aim of this study was to test the feasibility and monitor the success rate of a new ultrasound-guided spermatic cord block.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Local anaesthetic blocks of the greater occipital nerve (GON) are frequently performed in different types of headache, but no selective approaches exist. Our cadaver study compares the sonographic visibility of the nerve and the accuracy and specificity of ultrasound-guided injections at two different sites. METHODS: After sonographic measurements in 10 embalmed cadavers, 20 ultrasound-guided injections of the GON were performed with 0.1 ml of dye at the classical site (superior nuchal line) followed by 20 at a newly described site more proximal (C2, superficial to the obliquus capitis inferior muscle). The spread of dye and coloration of nerve were evaluated by dissection. RESULTS: The median sonographic diameter of the GON was 4.2 x 1.4 mm at the classical and 4.0 x 1.8 mm at the new site. The nerves were found at a median depth of 8 and 17.5 mm, respectively. In 16 of 20 in the classical approach and 20 of 20 in the new approach, the nerve was successfully coloured with the dye. This corresponds to a block success rate of 80% (95% confidence interval: 58-93%) vs 100% (95% confidence interval: 86-100%), which is statistically significant (McNemar's test, P=0.002). CONCLUSIONS: Our findings confirm that the GON can be visualized using ultrasound both at the level of the superior nuchal line and C2. This newly described approach superficial to the obliquus capitis inferior muscle has a higher success rate and should allow a more precise blockade of the nerve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although postmortem CT suffices for diagnosing most forms of traumatic death, the examination of natural death is, to date, very difficult and error prone. The introduction of postmortem angiography has led to improved radiologic diagnoses of natural deaths. Nevertheless, histologic changes to tissues, an important aspect in traditional examination procedures, remain obscure even with CT and CT angiography. For this reason, we examined the accuracy of a minimally invasive procedure (i.e., CT angiography combined with biopsy) in diagnosing major findings and the cause of death in natural deaths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study we sought to evaluate the reproducibility of sensory nerve conduction studies (NCS) using ultrasound-guided needle positioning (USNP).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated a novel, sled-mounted needle guide for ultrasound-guided vessel cannulation. Fifty medical students were randomly assigned to use ultrasound with the sled (sled group, n = 23) or ultrasound without the sled (control group, n = 27) for vessel cannulation in a phantom. For each of 15 attempts we recorded cannulation time and designated a successful cannulation as 1 and a failure as 0. Our primary outcome was the mean overall success rate. The median (IQR [range]) number of successes in the sled group and control group were 15.0 (13.0-15.0 [11.0-15.0]) and 11.0 (9.0-13.0 [6.0-15.0]), respectively (p < 0.001). Cannulation time decreased from the first to the last attempt in the sled group from 7.0 s (6.0-10.0 [4.0-16]) s to 4.0 s (3.0-4.0 [1.0-6.0]) s and in the control group from 35.0 s (27.0-35.0 [11.0-35.0]) s to 7.0 s (5.0-10.0 [3.0-25.0]) s. The sled group demonstrated a shorter cannulation time at each attempt (p < 0.001). The novel sled improved the success rate and efficiency of ultrasound-guided phantom vessel cannulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The suprascapular nerve (SSN) block is frequently performed for different shoulder pain conditions and for perioperative and postoperative pain control after shoulder surgery. Blind and image-guided techniques have been described, all of which target the nerve within the supraspinous fossa or at the suprascapular notch. This classic target point is not always ideal when ultrasound (US) is used because it is located deep under the muscles, and hence the nerve is not always visible. Blocking the nerve in the supraclavicular region, where it passes underneath the omohyoid muscle, could be an attractive alternative.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective  To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Study design  Prospective experimental cadaver study. Animals  Twenty equine cadavers. Methods  Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). Results  Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. Conclusion and clinical relevance  The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To document the practice and training opportunities of US-guided arthrocentesis and joint injection (UGAJ) among rheumatologists in the member countries of the European League Against Rheumatism (EULAR).