498 resultados para Treadmill
Resumo:
Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.
Resumo:
Ischaemia modified albumin (IMA) is considered a biomarker of myocardial ischaemia in humans in contrast to other biomarkers released when cardiac necrosis occurs. Little is known about release conditions of IMA in exercise and this is the first report in equine species. For this purpose, ten clinically healthy untrained horses were submitted to a high intensity test (HIT) followed by a low intensity test (LIT) seven days later. Blood samples were taken before, during and immediately after exercise, and 15 min and 30 min thereafter. Serum IMA, lactate and albumin, and plasma malondialdehyde (MDA) were determined. There were no significant changes in IMA concentration in any of the exercise tests. There was also a negative correlation between IMA and albumin levels in both tests, and between IMA and lactate levels in LIT, suggesting possible assay interferences. It was concluded that HIT and LIT did not promote significant changes in IMA concentration in horses under these conditions.
Resumo:
Studio della validità e affidabilità dell'informazione scientifica, fornita in output, da un particolare prototipo di accelerometro da polso, denominato "MyBand" dell'azienda "IDT Technology". La validazione è stata fatta in termini di consumo calorico, secondo due tipi di analisi: - Criterion validity: confrontando il dato in uscita con quello ottenuto tramite calorimetria indiretta; - Concurrent validity: confrontando il dato in uscita con quello rilevato da un altro accelerometro, già scientificamente validato (MyWellness Key). E' stato sviluppato un protocollo di studi, suddiviso in sei step di camminata e corsa su treadmill, che è stato eseguito da 23 persone (13 maschi e 10 femmine). I dati in uscita sono stati studiati tramite grafici di correlazione e di Blan-Altman, per verificare quindi la validità e l'affidabilità del valore di consumo calorico fornito da "MyBand".
Resumo:
Lo scopo della tesi è verificare se esiste nell’uomo una correlazione tra le velocità preferite di corsa\cammino e i parametri antropometrici, e inoltre dare un significato ai segnali acquisiti dall’analisi del passo tramite uno strumento in fase di sviluppo. Sono stati reclutati 20 soggetti mediamente allenati e suddivisi equamente per sesso. I soggetti sono stati sottoposti ad un protocollo di test motori su treadmill diviso in due parti. I dati del primo test sono stati acquisiti manualmente mentre i dati del secondo test sono stati acquisiti da uno strumento e inviati a remoto. L’elaborazione dei risultati di entrambi i test è stata effettuata utilizzando i software Microsoft Excell e Matlab R2010a. Dai dati è emerso un trend significativo per le velocità di corsa in funzione delle altezze, ma non per quelle di cammino. Per le seconde è stata invece riscontrata una netta differenza tra soggetti maschili e femminili che ha portato a classificare i due sessi separatamente. I parametri riguardanti l’analisi del passo del secondo test sono risultati qualitativamente accettabili e confrontabili con la letteratura, ma sarà necessaria una futura validazione sperimentale per la conferma scientifica.
Resumo:
Analisi cinematica dell'arto inferiore durante il cammino in acqua su treadmill
Resumo:
Exercise intolerance may be reported by parents of young children with respiratory diseases. There is, however, a lack of standardized exercise protocols which allow verification of these reports especially in younger children. Consequently the aims of this pilot study were to develop a standardized treadmill walking test for children aged 4-10 years demanding low sensorimotor skills and achieving high physical exhaustion. In a prospective experimental cross sectional pilot study, 33 healthy Caucasian children were separated into three groups: G1 (4-6 years, n = 10), G2 (7-8 years, n = 12), and G3 (9-10 years, n = 11). Children performed the treadmill walking test with increasing exercise levels up to peak condition with maximal exhaustion. Gas exchange, heart rate, and lactate were measured during the test, spirometry before and after. Parameters were statistically calculated at all exercise levels as well as at 2 and 4 mmol/L lactate level for group differences (Kruskal-Wallis H-test, alpha = 0.05; post hoc: Mann-Whitney U-test with Bonferroni correction alpha = 0.05/n) and test-retest differences (Wilcoxon-rank-sum test) with SPSS. The treadmill walking test could be demonstrated to be feasible with a good repeatability within groups for most of the parameters. All children achieved a high exhaustion level. At peak level under exhaustion condition only the absolute VO2 and VCO2 differed significantly between age groups. In conclusion this newly designed treadmill walking test indicates a good feasibility, safety, and repeatability. It suggests the potential usefulness of exercise capacity monitoring for children aged from early 4 to 10 years. Various applications and test modifications will be investigated in further studies.
Resumo:
Lumbar spinal stenosis is a frequent indication for spinal surgery. The predictive quality of treadmill testing and MRI for diagnostic verification is not yet clearly defined. Aim of the current study was to assess correlations between treadmill testing and MRI findings in the lumbar spine. Twenty-five patients with lumbar spinal stenosis were prospectively examined. Treadmill tests were performed and the area of the dural sac and neuroforamina was examined with MRI for the narrowest spinal segment. VAS and ODI were used for clinical assessment. The median age of the patients was 67 years. In the narrowest spinal segment the median area of the dural sac was 91 mm(2). The median ODI was 66 per cent. The median walking distance in the treadmill test was 70 m. The distance reached in the treadmill test correlated with the area of the dural sac (Spearman's rho = 0.53) and ODI (rho = -0.51), but not with the area of the neuroforamina and VAS. The distance reached in the treadmill test predicts the grade of stenosis in MRI but has a limited diagnostic importance for the level of clinical symptoms in lumbar spinal stenosis.
Resumo:
Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.
Resumo:
BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.
Resumo:
Background. To explore the efficacy of cycle training in the treatment of intermittent claudication, the present study compared performance and physiologic effects of cycle training with more conventional treadmill walking training in a group of patients with claudication. Method: Forty-two individuals with peripheral arterial disease and intermittent claudication (24 men, 18 women) were stratified by gender and the presence or absence of type 2 diabetes mellitus and then randomized to a treadmill (n = 13), cycle (n = 15), or control group (n = 14). Treadmill and cycle groups trained three times a week for 6 weeks, whereas the control group did not train during this period. Maximal and pain-free exercise times were measured on graded treadmill and cycle tests before and after training. Results. Treadmill training significantly improved maximal and pain-free treadmill walking times but did not improve cycle performance. Cycle training significantly improved maximal cycle time but did not improve treadmill performance. However, there was evidence of a stronger cross-transfer effect between the training modes for patients who reported a common limiting symptom during cycling and walking at baseline. There was also considerable variation in the training response to cycling, and a subgroup of responsive patients in the cycle group improved their walking performance by more than the average response observed in the treadmill group. Conclusion: These findings suggest that cycle exercise is not effective in improving walking performance in all claudication patients but might be an effective alternative to walking in those who exhibit similar limiting symptoms during both types of exercise.
Resumo:
Introduction: Walking programmes are recommended as part of the initial treatment for intermittent claudication (IC). However, for many patients factors such as frailty, the severe leg discomfort associated with walking and safety concerns about exercising in public areas reduce compliance to such prescription. Thus, there is a need to identify a mode of exercise that provides the same benefits as regular walking while also offering convenience and comfort for these patients. The present study aims to provide evidence for the first time of the efficacy of a supervised cycle training programme compared with a conventional walking programme for the treatment of IC. Methods: Thus far 33 patients have been randomized to: a treadmill-training group (n = 12); a cycle-training group (n = 11); or a control group (n = 10). Training groups participated in three sessions of supervised training per week for a period of 6 weeks. Control patients received no experimental intervention. Maximal incremental treadmill testing was performed at baseline and after the 6 weeks of training. Measures included pain-free (PFWT) and maximal walking time (MWT), continuous heart rate and gas-analysis recording, and ankle-brachial index assessment. Results: In the treadmill trained group MWT increased significantly from 1016.7 523.7 to 1255.2 432.2 s (P < 0.05). MWT tended to increase with cycle training (848.72 333.18 to 939.54 350.35 s, P = 0.14), and remained unchanged in the control group (1555.1 683.23 to 1534.7 689.87 s). For PFWT, there was a non-significant increase in the treadmill-training group from 414.4 262.3 to 592.9 381.9 s, while both the cycle training and control groups displayed no significant change in this time (226.7 147.1 s to 192.3 56.8 and 499.4 503.7 s to 466.0 526.1 s, respectively). Conclusions: These preliminary results might suggest that, unlike treadmill walking, cycling has no clear effect on walking performance in patients with IC. Thus the current recommendations promoting walking based programmes appear appropriate. The present study was funded by the National Heart Foundation of Australia.
Resumo:
Background: Obesity and asthma are an important public health problem in Saudi Arabia. An increasing body of data supports the hypothesis that obesity is a risk factor for asthma. Asthma appears to be associated with low bone mineral density (BMD) due to long-term use of corticosteroids. Studies recently showed that weight bearing exercise training can increase mineral bone density, reduce weight and improve metabolic control. Objective: The present study aimed to measure the effects of treadmill walking exercises on bone mineral status and inflammatory cytokines in obese asthmatic patients treated with long term intake of corticosteroids. Methods: Eighty obese asthmatic patients of both sexes, their age ranged from 41 to 53 years. Subjects were divided into two equal groups: training group (group A) received aerobic exercise training on treadmill for six months in addition to the medical treatment where, the control group (group B) received only the medical treatment. Results: The results of this study indicated a significant increase in BMD of the lumbar spine & the radius, serum calcium and high density lipoprotein cholesterol (HDL-c) & significant reduction in parathyroid hormone, leptin, tumor necrosis factor– alpha(TNF-α), interleukin-2 (IL-2), interleukin-4 (IL-4), interleukin-6 (IL-6), low density lipoprotein cholesterol (LDL-c), triglycerides (TG) and body mass index (BMI) in group (A), while these changes were not significant in group (B).Also; there was a significant difference between both groups at the end of the study. Conclusion: Treadmill walking exercise training is an effective treatment policy to improve bone mineral status and modulates inflammatory cytokines and blood lipids profile in obese asthmatic patients with long term intake of corticosteroids.