999 resultados para Transient Outward Current


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nowadays advanced simulation technologies of semiconductor devices occupies an important place in microelectronics production process. Simulation helps to understand devices internal processes physics, detect new effects and find directions for optimization. Computer calculation reduces manufacturing costs and time. Modern simulation suits such as Silcaco TCAD allow simulating not only individual semiconductor structures, but also these structures in the circuit. For that purpose TCAD include MixedMode tool. That tool can simulate circuits using compact circuit models including semiconductor structures with their physical models. In this work, MixedMode is used for simulating transient current technique setup, which include detector and supporting electrical circuit. This technique was developed by RD39 collaboration project for investigation radiation detectors radiation hard properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fast transient current decay was recorded on POMA samples during current pulses (in the order of milliseconds) provided by a low energy electron beam under an applied field. The characteristic time decay depends on the electron beam energy and on the bias polarity. The results were explained taking into account the effect of space charge, the intrinsic conductivity of the non-irradiated region of the sample and the radiation-induced conductivity of the thin irradiated region. Fitting parameters may provide the value of both intrinsic and radiation-induced conductivities and the average electron range.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Charge transport and shelf-degradation of MEH-PPV thin-films were investigated through stationary (e.g. current versus voltage - JxV) and transient (e.g. Time-of-Flight - ToF, Dark-Injection Space-Charge-Limited Current - DI-SCLC, Charge Extraction by Linearly Increasing Voltage - CELN) current techniques. Charge carrier mobility in nanometric films was best characterized through JxV and DI-SCLC. It approaches 10(-6) cm(2)Ns under a SCLC regime with deep traps for light-emitting diode applications. ToF measurements performed on micrometric layers (i.e. - 3 mu m) confirmed studies in 100 nm-thick films as deposited in OLEDs. All results were comparable to a similar poly(para-phenylene vinylene) derivative, MDMO-PPV. Electrical properties extracted from thin-film transistors demonstrated mobility dependence on carrier concentration in the channel (similar to 10(-7)-10(-4) cm(2)/Vs). At low accumulated charge levels and reduced free carrier concentration, a perfect agreement to the previously cited techniques was observed. Degradation was verified through mobility reduction and changes in trap distribution of states. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Classical mammalian transient receptor potential channels form non-selective cation channels that open in response to activation of phospholipase C-coupled metabotropic receptors, and are thought to play a key role in calcium homeostasis in non-excitable cells. Within the nervous system transient receptor potential channels are widely distributed but their physiological roles are not well understood. Here we show that in the rat lateral amygdala transient receptor potential channels mediate an excitatory synaptic response to glutamate. Activation of group l etabotropic glutamate receptors on pyramidal neurons in the lateral amygdala with either exogenous or synaptically released glutamate evokes an inward current at negative potentials with a current voltage relationship showing a region of negative slope and steep outward rectification. This current is blocked by inhibiting G protein function with GTP-beta-S, by inhibiting phospholipase C or by infusing transient receptor potential antibodies into lateral amygdala pyramidal neurons. Using RT-PCR and Western blotting we show that transient receptor potential 1, transient receptor potential 4 and transient receptor potential 5 are present in the lateral amygdala. Single cell PCR confirms the presence of transient receptor potential 1 and transient receptor potential 5 in pyramidal neurons and we show by co-immunoprecipitation that transient receptor potential 1 and transient receptor potential 5 co-assemble as a heteromultimers in the amygdala. These results show that in lateral amygdala pyramidal neurons synaptically released glutamate activates transient receptor potential channels, which we propose are likely to be heteromultimeric channels containing transient receptor potential 1 and transient receptor potential 5/transient receptor potential 4. (c) 2005 Published by Elsevier Ltd on behalf of IBRO.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Substrate current injection is the origin of external latchup and substrate noise coupling. The trigger current for external latchup depends on the duration of the trigger event. A physics-based model is provided to model the effects of aggressor to victim spacing and orientation on transient triggering of external latchup. The latchup susceptibility of standard cell based designs is also investigated. Guard rings are used to reduce latchup susceptibility and to reduce the substrate noise coupled to sensitive analog circuits. In this work, the effectiveness of different guard ring topologies for the reduction of substrate noise coupling is also investigated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the past decade, perovskites have been under the spotlight as promising semicon- ductors with unique properties. Hybrid halide perovskites show excellent characteristic properties suitable for optoelectronic applications as tunable band gap, high absorption coefficient, large mobility and long carrier recombination lifetime. However, a complete understanding of environmental instability and the nature of defects in these materials is still lacking, hindering the development of perovskite-based technologies. In this work we studied MAPbBr3 single crystals, fabricated with Inverse Temperature Crystallization (ITC) technique, with Photo-Induced Current Transient Spectroscopy (PICTS). PICTS is a transient photocurrent measurement rarely employed for studying perovskites mate- rials, that allows for the defects characterization in high resistivity materials. We studied the samples under different conditions, such as negative and positive voltage biases, bias stress, different contact geometries and different illumination wavelengths, in order to study their effect on the material physical properties and to evaluate the trap activation energies and their behavior under different working conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) and spectroscopy (MRS) allow establishing theanatomical evolution and neurochemical profiles of ischemic lesions. However onlylimited MRS studies have been reported to-date in mice due to the challenges ofMRS in small organs. The aim of the current work was to study the neurochemicaland imaging sequelae of ischemic stroke in a mouse model in a horizontal bore14.1 Tesla system.ICR-CD1 mice were subjected to 30 minute transient middle cerebral artery occlusion.The extent of the lesion was determined by MRI. The neurochemical profileconsisting of the concentrations of 22 metabolites was measured longitudinallyfollowing the recovery from ischemia at 3, 8 and 24h in the striatum.Our model produced very reproducible striatal lesions which began to appear onT2-weighted images 8h after ischemia. At 24h, they were well established andtheir size correlated with lesions measured by histology. Profound changes couldbe observed in the neurochemical profiles of the core of the striatal lesions as earlyas 3h post-ischemia, in particular, we observed elevated lactate levels, decreases inthe putative neuronal marker N-acetyl-aspartate and in glutamate, and a transienttwo-fold glutamine increase, likely linked to excitotoxic release of glutamate andconversion to glutamine. With further ischemia evolution, other changes appearedat later time-points, mainly decreases of metabolites, consistent with disruption ofcellular function. It is interesting to note that glutamine tended to return to basallevels at 24h.We conclude that early changes in markers of energy metabolism, glutamate excitotoxicityand neuronal viability can be detected with high precision non-invasively inmice following stroke. Such investigations should lead to a better understanding andinsight into the sequential early changes in the brain parenchyma after ischemia,which could be used e.g. for identifying new targets for neuroprotection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Chronic liver diseases (CLDs) are significant causes of death in adults in many countries and are usually diagnosed at late stages. Early detection may allow time for treatment to prevent disease progression. Objectives: The aim of this study was to assess the feasibility of screening for unrecognized CLDs in a primary care nurse consultancy and report findings from screening. Methods: Two experienced nurses in a primary care nurse consultancy were trained to perform transient elastography (TE). Subjects aged from 18 to 70 years were identified randomly from the health registry and invited to participate in a feasibility pilot study. Exclusion criteria were past or current history of liver diseases. Nurses collected demographic and clinical data and performed TE tests using Fibroscan tomeasure liver stiffness; a cutoff score of 6.8 kPa or greater was used as an indicator of the presence of CLD with fibrosis. Results: Accurate measurements were obtained in 495 of 502 participants (98.6%). Prevalence of elevated liver stiffness was observed in 28 of 495 subjects (5.7%). Compared to patients with normal liver stiffness, patients with increased liver stiffness were older, were more frequently male, and had higher frequency of metabolic syndrome. Nonalcoholic fatty liver was the most common cause of CLD. Discussion: Following training in procedures for conducting TE, nurses in a primary care clinic were able to detect unrecognized CLDs in presumably healthy subjects. Early detection of CLDs is feasible in primary care clinics and may facilitate identification of undiagnosed CLD in adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complex permittivity of films of polyether ether ketone (PEEK) has been investigated over a wide range of frequency. There is no relaxation peak in the range of 1Hz to 10(5) Hz but in the low-frequency side (10-4 Hz) there is an evidence of a peak that also can be observed by thermally stimulated discharge current measurements. That peak is related with the glass transition temperature (Tg) of the polymer. The activation energy of the relaxation was found to be 0.44 eV, similar to that of several synthetic polymers. Space charges are important in the conduction mechanism as shown by discharging transient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

T-type Ca2+ channels are important for cell signaling by a variety of cells. We report here the electrophysiological and molecular characteristics of the whole-cell Ca2+ current in GH3 clonal pituitary cells. The current inactivation at 0 mV was described by a single exponential function with a time constant of 18.32 ± 1.87 ms (N = 16). The I-V relationship measured with Ca2+ as a charge carrier was shifted to the left when we applied a conditioning pre-pulse of up to -120 mV, indicating that a low voltage-activated current may be present in GH3 cells. Transient currents were first activated at -50 mV and peaked around -20 mV. The half-maximal voltage activation and the slope factors for the two conditions are -35.02 ± 2.4 and 6.7 ± 0.3 mV (pre-pulse of -120 mV, N = 15), and -27.0 ± 0.97 and 7.5 ± 0.7 mV (pre-pulse of -40 mV, N = 9). The 8-mV shift in the activation mid-point was statistically significant (P < 0.05). The tail currents decayed bi-exponentially suggesting two different T-type Ca2+ channel populations. RT-PCR revealed the presence of a1G (CaV3.1) and a1I (CaV3.3) T-type Ca2+ channel mRNA transcripts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The principles of operation of an experimental prototype instrument known as J-SCAN are described along with the derivation of formulae for the rapid calculation of normalized impedances; the structure of the instrument; relevant probe design parameters; digital quantization errors; and approaches for the optimization of single frequency operation. An eddy current probe is used As the inductance element of a passive tuned-circuit which is repeatedly excited with short impulses. Each impulse excites an oscillation which is subject to decay dependent upon the values of the tuned-circuit components: resistance, inductance and capacitance. Changing conditions under the probe that affect the resistance and inductance of this circuit will thus be detected through changes in the transient response. These changes in transient response, oscillation frequency and rate of decay, are digitized, and then normalized values for probe resistance and inductance changes are calculated immediately in a micro processor. This approach coupled with a minimum analogue processing and maximum of digital processing has advantages compared with the conventional approaches to eddy current instruments. In particular there are: the absence of an out of balance condition and the flexibility and stability of digital data processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The images taken by the Heliospheric Imagers (HIs), part of the SECCHI imaging package onboard the pair of STEREO spacecraft, provide information on the radial and latitudinal evolution of the plasma compressed inside corotating interaction regions (CIRs). A plasma density wave imaged by the HI instrument onboard STEREO-B was found to propagate towards STEREO-A, enabling a comparison between simultaneous remotesensing and in situ observations of its structure to be performed. In situ measurements made by STEREO-A show that the plasma density wave is associated with the passage of a CIR. The magnetic field compressed after the CIR stream interface (SI) is found to have a planar distribution. Minimum variance analysis of the magnetic field vectors shows that the SI is inclined at 54° to the orbital plane of the STEREO-A spacecraft. This inclination of the CIR SI is comparable to the inclination of the associated plasma density wave observed by HI. A small-scale magnetic cloud with a flux rope topology and radial extent of 0.08 AU is also embedded prior to the SI. The pitch-angle distribution of suprathermal electrons measured by the STEREO-A SWEA instrument shows that an open magnetic field topology in the cloud replaced the heliospheric current sheet locally. These observations confirm that HI observes CIRs in difference images when a small-scale transient is caught up in the compression region.