883 resultados para Transgenic organisms Risk assessment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Formaldehyde (CH2O), the most simple and reactive of all aldehydes, is colorless, and readily polymerizing gas at normal temperature. The most extensive use is in production of resins and has an important application as a disinfectant and preservative, reason why relevant workplace exposure may also occur in pathology and anatomy laboratories and in mortuaries. A study was carried out in Portugal, in a formaldehyde production resins factory and in 10 pathology and anatomy laboratories. It was applied a risk assessment methodology based on Queensland University proposal that permitted to perform risk assessment for each activity developed in a work station. This methodology was applied in 83 different activities developed in the laboratories and in 18 activities of the factory. Also, Micronucleus Test was performed in lymphocytes from 30 factory workers and 50 laboratories workers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Moulds may produce a diversity of toxins such as aflatoxins, ochratoxins, trichothecenes, zearalenone, fumonisins and others. Although toxicological, environmental and epidemiological studies have addressed the problem of these toxins one by one, more than one mycotoxin are found usually in the same contaminated food. Risk assessment for humans potentially exposed to multimycotoxins suffers very much from the lack of adequate food consumption data. Furthermore, for a given mycotoxin, synergism and antagonism with other mycotoxins, found in the same food commodities, are not taken into account. Aflatoxin B1 and ochratoxin A belong to the most frequently occurring mycotoxins. This has repeatedly been demonstrated, however, normally, the risk resulting from their simultaneous occurrence is not considered. A descriptive study was developed to monitor air fungal contamination in one hospital food unit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conferência: 9th International Symposium on Occupational Safety and Hygiene (SHO) Guimaraes, Portugal - FEB 14-15, 2013

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the health risk of exposure to benzene for a community affected by a fuel leak. METHODS: Data regarding the fuel leak accident with, which occurred in the Brasilia, Federal District, were obtained from the Fuel Distributor reports provided to the environmental authority. Information about the affected population (22 individuals) was obtained from focal groups of eight individuals. Length of exposure and water benzene concentration were estimated through a groundwater flow model associated with a benzene propagation model. The risk assessment was conducted according to the Agency for Toxic Substances and Disease Registry methodology. RESULTS: A high risk perception related to the health consequences of the accident was evident in the affected community (22 individuals), probably due to the lack of assistance and a poor risk communication from government authorities and the polluting agent. The community had been exposed to unsafe levels of benzene (> 5 µg/L) since December 2001, five months before they reported the leak. The mean benzene level in drinking water (72.2 µg/L) was higher than that obtained by the Fuel Distributer using the Risk Based Corrective Action methodology (17.2 µg/L).The estimated benzene intake from the consumption of water and food reached a maximum of 0.0091 µg/kg bw/day (5 x 10-7 cancer risk per 106 individuals). The level of benzene in water vapor while showering reached 7.5 µg/m3 for children (1 per 104 cancer risk). Total cancer risk ranged from 110 to 200 per 106 individuals. CONCLUSIONS: The population affected by the fuel leak was exposed to benzene levels that might have represented a health risk. Local government authorities need to develop better strategies to respond rapidly to these types of accidents to protect the health of the affected population and the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environment monitoring has an important role in occupational exposure assessment. However, due to several factors is done with insufficient frequency and normally don´t give the necessary information to choose the most adequate safety measures to avoid or control exposure. Identifying all the tasks developed in each workplace and conducting a task-based exposure assessment help to refine the exposure characterization and reduce assessment errors. A task-based assessment can provide also a better evaluation of exposure variability, instead of assessing personal exposures using continuous 8-hour time weighted average measurements. Health effects related with exposure to particles have mainly been investigated with mass-measuring instruments or gravimetric analysis. However, more recently, there are some studies that support that size distribution and particle number concentration may have advantages over particle mass concentration for assessing the health effects of airborne particles. Several exposure assessments were performed in different occupational settings (bakery, grill house, cork industry and horse stable) and were applied these two resources: task-based exposure assessment and particle number concentration by size. The results showed interesting results: task-based approach applied permitted to identify the tasks with higher exposure to the smaller particles (0.3 μm) in the different occupational settings. The data obtained allow more concrete and effective risk assessment and the identification of priorities for safety investments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fungi are essential to the survival of our global ecology, but they might pose a significant threat to the health of occupants when they grow in our buildings. The exposure to fungi in homes is a significant risk factor for a number of respiratory symptoms. Well-known illnesses caused by fungi include allergy and hypersensitivity pneumonitis. Environmental monitoring for fungi and their disease agents are important aspects of exposure assessment, but few guidelines exist for interpreting their health impacts. This book answers the questions: How does one detect and measure the presence of indoor fungi? What is an acceptable level of indoor fungi? How do we relate this information to human health problems?

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis submitted to the Faculdade de Ciências e Tecnologia to obtain the Master’s degree in Environmental Engineering, profile in Ecological Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Innovation is considered crucial for enterprises survival and current economic environment demands the best ways of achieving it. However, the development of complex products and services require the utilization of diverse know-how and technology, which enterprises may not hold. An effective strategy for achieving them is to rely in open innovation. Still, open innovation projects may fail for many causes, e.g. due to the dynamics of collaboration between partners. To effectively benefit from open innovation, it is recommended the utilization of adequate risk models. For achieving such models, a preliminary conceptualization of open innovation and risk is necessary, which includes modeling experiments with existing risk models, such as the FMEA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of unmanned marine robotic vehicles in bathymetric surveys is discussed. This paper presents recent results in autonomous bathymetric missions with the ROAZ autonomous surface vehicle. In particular, robotic surface vehicles such as ROAZ provide an efficient tool in risk assessment for shallow water environments and water land interface zones as the near surf zone in marine coast. ROAZ is an ocean capable catamaran for distinct oceanographic missions, and with the goal to fill the gap were other hydrographic surveys vehicles/systems are not compiled to operate, like very shallow water rivers and marine coastline surf zones. Therefore, the use of robotic systems for risk assessment is validated through several missions performed either in river scenario (in a very shallow water conditions) and in marine coastlines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Industrial

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT:C-reactive protein (CRP) has been widely used in the early risk assessment of patients with acute pancreatitis (AP), but unclear aspects about its prognostic accuracy in this setting persist. This project evaluated first CRP prognostic accuracy for severity, pancreatic necrosis (PNec), and in-hospital mortality (IM) in AP in terms of the best timing for CRP measurement and the optimal CRP cutoff points. Secondly it was evaluated the CRP measured at approximately 24 hours after hospital admission (CRP24) prognostic accuracy for IM in AP individually and in a combined model with a recent developed tool for the early risk assessment of patients with AP, the Bedside Index for Severity in AP (BISAP). Two single-centre retrospective cohort studies were held. The first study included 379 patients and the second study included 134 patients. Statistical methods such as the Hosmer-Lemeshow goodness-of-fit test, the area under the receiver-operating characteristic curve, the net reclassification improvement, and the integrated discrimination improvement were used. It was found that CRP measured at approximately 48 hours after hospital admission (CRP48) had a prognostic accuracy for severity, PNec, and IM in AP better than CRP measured at any other timing. It was observed that the optimal CRP48 cutoff points for severity, PNec, and IM in AP varied from 170mg/l to 190mg/l, values greater than the one most often recommended in the literature – 150mg/l. It was found that CRP24 had a good prognostic accuracy for IM in AP and that the cutoff point of 60mg/l had a negative predictive value of 100%. Finally it was observed that the prognostic accuracy of a combined model including BISAP and CRP24 for IM in AP could perform better than the BISAP alone model. These results might have a direct impact on the early risk assessment of patients with AP in the daily clinical practice.--------- RESUMO: A proteina c-reactiva (CRP) tem sido largamente usada na avaliação precoce do risco em doentes com pancreatite aguda (AP), mas aspectos duvidosos acerca do seu valor prognóstico neste contexto persistem. Este projecto avaliou primeiro o valor prognóstico da CRP para a gravidade, a necrose pancreática (PNec) e a mortalidade intra-hospitalar (IM) na AP em termos do melhor momento para efectuar a sua medição e dos seus pontos-de-corte óptimos. Em segundo lugar foi avaliado o valor prognóstico da proteína c-reactiva medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) para a IM na AP isoladamente e num modelo combinado, que incluiu uma ferramenta de avaliação precoce do risco em doentes com AP recentemente desenvolvida, o Bedside Index for Severity in Acute Pancreatitis (BISAP). Dois estudos unicêntricos de coorte retrospectivo foram realizados. O primeiro estudo incluiu 379 doentes e o segundo estudo incluiu 134 doentes. Metodologias estatísticas como o teste de Hosmer-Lemeshow goodness-of-fit, a area under the receiver-operating characteristic curve, o net reclassification improvement e o integrated discrimination improvement foram usadas. Verificou-se que a CRP medida às 48 horas após a admissão hospitalar (CRP48) teve um valor prognóstico para a gravidade, a PNec e a IM na AP melhor do que a CRP medida em qualquer outro momento. Observou-se que os pontos de corte óptimos da CRP48 para a gravidade, a PNec e a IM na AP variaram entre 170mg/l e 190mg/l, valores acima do valor mais frequentemente recomendado na literatura – 150mg/l. Verificou-se que a CRP medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) teve um bom valor prognóstico para a IM na AP e que o ponto de corte 60mg/l teve um valor preditivo negativo de 100%. Finalmente observou-se que o valor prognóstico de um modelo combinado incluindo o BISAP e a CRP24 para a IM na AP pode ter um desempenho melhor do que o do BISAP isoladamente. Estes resultados podem ter um impacto directo na avaliação precoce do risco em doentes com AP na prática clínica diária.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A foremost dispute that persists on the contemporary world’s agenda is change. The on-going social/technological/economic changes create a competitive and challenging environment for companies to endure. To benefit from these changes, world economies partially depend on emerging Small and Medium Enterprises (SMEs) and their adaptability skills, and subsequently the development of an integrated capability to innovate has become the prime strategy for most of SMEs to subsist and grow. However, innovation and change are always somewhat bonded to an inherent risk development, which subsequently brings on the necessity of a revision of risk management approaches in innovative processes, whose importance SMEs tend to disregard. Additionally, little efforts have been made to improve and create empirical models, metrics and tools to assist SMEs managing latent risks in their innovative projects. This work seeks to present and discuss a solution to support SMEs in engaging on systematic risk management practices, which consists on an integrated risk assessment and response support web-based tool - Spotrisk® - designed for SMEs. On the other hand, an inherent subjectivity is linked with risk management and identification processes, due to uncertainty trait of its nature, for each individual perceives situations according to his own idiosyncrasy, which brings complications in normalizing risk profiles and procedures. This essay aims to bring insights concerning the support in decision-making processes under uncertainty, by addressing issues related with the risk behavior character among individuals. To address such issues, subjects of neuroscience or psychology are explored and models to identify such character are proposed, as well as models to improve presented tool. This work attempts to go beyond the restrictive aim of endeavoring on technical improvement dissertation, and in embraces an exploratory conceptualization concerning micro, small and medium businesses’ traits regarding risk characters and project risk assessment tools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The occupational risks in the nanotechnology research laboratories are an important topic since a great number of researchers are involved in this area. The risk assessment performed by both qualitative and quantitative methods is a necessary step for the management of the occupational risks. Risk assessment could be performed by qualitative methods that gather consensus in the scientific community. It is also possible to use quantitative methods, based in different technics and metrics, as indicative exposure limits are been settled by several institutions. While performing the risk assessment, the information on the materials used is very important and, if it is not updated, it could create a bias in the assessment results. The exposure to TiO2 nanoparticles risk was assessed in a research laboratory using a quantitative exposure method and qualitative risk assessment methods. It was found the results from direct-reading Condensation Particle Counter (CPC) equipment and the CB Nanotool seem to be related and aligned, while the results obtained from the use of the Stoffenmanager Nano seem to indicate a higher risk level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although most of the accidents occurred in Olive Oil Mill (OOM) resulted from “basic” risks, there is a need to apply adequate tools to support risk decisions that can meet the specificities of this sector. This study aims to analyse the views of Occupational, Safety & Health (OSH) practitioners about the risk assessment process in OOM, identifying the key difficulties inherent to the risk assessment process in these sector, as well as identifying some improvements to the current practice. This analysis was based on a questionnaire that was developed and applied to 13 OSH practitioners working at OOM. The results showed that the time available to perform the risk assessment is the more frequent limitation. They believe that the methodologies available are not an important limitation to this process. However, a specific risk assessment methodology, that includes acceptance criteria adjusted to the OOM reality, using risk metrics supported on the frequency of accidents and workdays lost, were indicated as being also an important contributions improve the process. A semi-quantitative approach, complemented with the use of the sector accident statistics, can be a good solution for this sector. However, further strategies should also be adopted, mainly those that can lead to an easy application of the risk assessment process.