829 resultados para Total Knee Replacement Surgery, Orthopaedics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Patella resurfacing in total knee arthroplasty is a contentious issue. The literature suggests that resurfacing of the patella is based on surgeon preference, and little is known about the role and timing of resurfacing and how this affects outcomes. Methods We analyzed 134,799 total knee arthroplasties using data from the Australian Orthopaedic Association National Joint Replacement Registry. Hazards ratios (HRs) were used to compare rates of early revision between patella resurfacing at the primary procedure (the resurfacing group, R) and primary arthroplasty without resurfacing (no-resurfacing group, NR). We also analyzed the outcomes of NR that were revised for isolated patella addition. Results At 5 years, the R group showed a lower revision rate than the NR group: cumulative per cent revision (CPR) 3.1% and 4.0%, respectively (HR = 0.75, p < 0.001). Revisions for patellofemoral pain were more common in the NR group (17%) than in the R group (1%), and “patella only” revisions were more common in the NR group (29%) than in the R group (6%). Non-resurfaced knees revised for isolated patella addition had a higher revision rate than patella resurfacing at the primary procedure, with a 4-year CPR of 15% and 2.8%, respectively (HR = 4.1, p < 0.001). Interpretation Rates of early revision of primary total knees were higher when the patella was not resurfaced, and suggest that surgeons may be inclined to resurface later if there is patellofemoral pain. However, 15% of non-resurfaced knees revised for patella addition are re-revised by 4 years. Our results suggest an early beneficial outcome for patella resurfacing at primary arthroplasty based on revision rates up to 5 years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the long term outcome of the flangeless, cemented all polyethylene Exeter cup at a mean of 14.6 years (range 10-17) after operation. Of the 263 hips in 243 patients, 122 hips are still in situ, 112 patients (119 hips) have died, eighteen hips were revised, and three patients (four hips) had moved abroad and were lost to follow-up (1.5%). Radiographs demonstrated two sockets had migrated and six more had radiolucent lines in all three zones. The Kaplan Meier survivorship at 15 years with endpoint revision for all causes is 89.9% (95% CI 84.6 to 95.2%) and for aseptic cup loosening or lysis 91.7% (CI 86.6 to 96.8%). In 210 hips with a diagnosis of primary osteoarthritis survivorship for all causes is 93.2% (95% CI 88.1 to 98.3%), and for aseptic cup loosening 95.0% (CI 90.3 to 99.7%). The cemented all polyethylene Exeter cup has an excellent long-term survivorship.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Removal of well-fixed cement at revision surgery risks bone loss, cortical perforation and fracture, is time-consuming, technically demanding and carries increased risks for the patient. The cement-in-cement technique avoids these problems and when used appropriately has given favourable results at our centre when used on both the femoral and acetabular sides of the articulation. A modified technique has also been used in selected cases of infection and peri-prosthetic fracture. This chapter highlights the results to date and the operative techniques employed. It is essential to recognise that this technique relies fundamentally on the presence of a well-fixed cement mantle, and it is imperative that the criteria laid out are adhered to in order to achieve success. If there is loosening or lysis on the femoral side extending distal to the lesser trochanter or around more than just the periphery of the acetabular cement mantle, then alternative revision techniques should be employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip arthroplasty. We describe the surgical technique and report the outcome of 60 consecutive cement-in-cement revisions of the acetabular component at a mean follow-up of 8.5 years (range 5-12 years). All had a radiologically and clinically well fixed acetabular cement mantle at the time of revision. 29 patients died. No case was lost to follow-up. The 2 most common indications for acetabular revision were recurrent dislocation (77%) and to compliment a femoral revision (20%). There were 2 cases of aseptic cup loosening (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at latest follow-up. One case was re-revised for infection, 4 for recurrent dislocation and 1 for disarticulation of a constrained component. At 5 years, the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI; 84.8-99.6%) with revision for all causes as the endpoint. These results support the use of the cement-in-cement revision technique in appropriate cases on the acetabular side. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients presenting for knee replacement on warfarin for medical reasons often require higher levels of anticoagulation peri-operatively than primary thromboprophylaxis and may require bridging therapy with heparin. We performed a retrospective case control study on 149 consecutive primary knee arthroplasty patients to investigate whether anti-coagulation affected short-term outcomes. Specific outcome measures indicated significant increases in prolonged wound drainage (26.8% of cases vs 7.3% of controls, p<0.001); superficial infection (16.8% vs 3.3%, p<0.001); deep infection (6.0% vs 0%, p<0.001); return-to-theatre for washout (4.7% vs 0.7%, p=0.004); and revision (4.7% vs 0.3%, p=0.001). Management of patients on long-term warfarin therapy following TKR is particularly challenging, as the surgeon must balance risk of thromboembolism against post-operative complications on an individual patient basis in order to optimise outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Malorientation of the socket contributes to instability after hip arthroplasty but the optimal orientation of the cup in relation to the pelvis has not been unequivocally described. Large radiological studies are few and problems occur with film standardisation, measurement methodology used and alternative definitions of describing acetabular orientation. Methods A cohort of 1,578 patients from a single institution is studied where all patient data was collected prospectively. Risk factors for patients undergoing surgery are analysed. Radiological data was compared between a series of non-dislocating hips and dislocating cases matched 2:1 by operation type, age and diagnosis. Results The overall dislocation rate for all 1,578 cases was 3.23% but the rate varied according to the type of surgery performed. The rate in uncomplicated primary cases was 2.4% which increased to 9.3% for second stage implantation for a two stage procedure for infection. There was no significant difference in the variability of the dislocating and non-dislocating groups for either inclination (p = 0.393) or anteversion (p = 0.661). Conclusions A “safe zone” for socket orientation to avoid dislocation could not be defined. The cause of dislocation is multifactorial, re-establishing the anatomic centre of rotation, balancing soft tissues and avoidance of impingement around the hip are important considerations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to identify the preoperative predictors of hospital length of stay after primary total knee arthroplasty in a patient population reflecting current trends toward shorter hospitalization and using readily obtainable factors that do not require scoring systems. A single-center, multi-surgeon retrospective chart review of two hundred and sixty consecutive patients who underwent primary total knee arthroplasty was performed. The mean length of stay was 3.0 days. Among the different variables studied, increasing comorbidities, lack of adequate assistance at home, and bilateral surgery were the only multivariable significant predictors of longer length of stay. The study was adequately powered for statistical analyses and the concordance index of the multivariable logistic regression model was 0.815.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Coordination is a strategy chosen by the central nervous system to control the movements and maintain stability during gait. Coordinated multi-joint movements require a complex interaction between nervous outputs, biomechanical constraints, and pro-prioception. Quantitatively understanding and modeling gait coordination still remain a challenge. Surgeons lack a way to model and appreciate the coordination of patients before and after surgery of the lower limbs. Patients alter their gait patterns and their kinematic synergies when they walk faster or slower than normal speed to maintain their stability and minimize the energy cost of locomotion. The goal of this study was to provide a dynamical system approach to quantitatively describe human gait coordination and apply it to patients before and after total knee arthroplasty. Methods: A new method of quantitative analysis of interjoint coordination during gait was designed, providing a general model to capture the whole dynamics and showing the kinematic synergies at various walking speeds. The proposed model imposed a relationship among lower limb joint angles (hips and knees) to parameterize the dynamics of locomotion of each individual. An integration of different analysis tools such as Harmonic analysis, Principal Component Analysis, and Artificial Neural Network helped overcome high-dimensionality, temporal dependence, and non-linear relationships of the gait patterns. Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects. Results: The new method provided coordination scores at various walking speeds, ranged between 0 and 10. It determined the overall coordination of the lower limbs as well as the contribution of each joint to the total coordination. The difference between the pre-operative and post-operative coordination values were correlated with the improvements of the subjective outcome scores. Although the study group was small, the results showed a new way to objectively quantify gait coordination of patients undergoing total knee arthroplasty, using only portable body-fixed sensors. Conclusion: A new method for objective gait coordination analysis has been developed with very encouraging results regarding the objective outcome of lower limb surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. METHODS: Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: <60, 61 to 90, 91 to 120, and >120 minutes. Three categories were defined for operative time: <120, 121 to 150, and >150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. RESULTS: In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. CONCLUSION: We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Total hip replacements (THRs) and total knee replacements (TKRs) are common elective procedures. In the REsearch STudies into the ORthopaedic Experience (RESTORE) programme, we explored the care and experiences of patients with osteoarthritis after being listed for THR and TKR up to the time when an optimal outcome should be expected. OBJECTIVE: To undertake a programme of research studies to work towards improving patient outcomes after THR and TKR. METHODS: We used methodologies appropriate to research questions: systematic reviews, qualitative studies, randomised controlled trials (RCTs), feasibility studies, cohort studies and a survey. Research was supported by patient and public involvement. RESULTS: Systematic review of longitudinal studies showed that moderate to severe long-term pain affects about 7–23% of patients after THR and 10–34% after TKR. In our cohort study, 10% of patients with hip replacement and 30% with knee replacement showed no clinically or statistically significant functional improvement. In our review of pain assessment few research studies used measures to capture the incidence, character and impact of long-term pain. Qualitative studies highlighted the importance of support by health and social professionals for patients at different stages of the joint replacement pathway. Our review of longitudinal studies suggested that patients with poorer psychological health, physical function or pain before surgery had poorer long-term outcomes and may benefit from pre-surgical interventions. However, uptake of a pre-operative pain management intervention was low. Although evidence relating to patient outcomes was limited, comorbidities are common and may lead to an increased risk of adverse events, suggesting the possible value of optimising pre-operative management. The evidence base on clinical effectiveness of pre-surgical interventions, occupational therapy and physiotherapy-based rehabilitation relied on small RCTs but suggested short-term benefit. Our feasibility studies showed that definitive trials of occupational therapy before surgery and post-discharge group-based physiotherapy exercise are feasible and acceptable to patients. Randomised trial results and systematic review suggest that patients with THR should receive local anaesthetic infiltration for the management of long-term pain, but in patients receiving TKR it may not provide additional benefit to femoral nerve block. From a NHS and Personal Social Services perspective, local anaesthetic infiltration was a cost-effective treatment in primary THR. In qualitative interviews, patients and health-care professionals recognised the importance of participating in the RCTs. To support future interventions and their evaluation, we conducted a study comparing outcome measures and analysed the RCTs as cohort studies. Analyses highlighted the importance of different methods in treating and assessing hip and knee osteoarthritis. There was an inverse association between radiographic severity of osteoarthritis and pain and function in patients waiting for TKR but no association in THR. Different pain characteristics predicted long-term pain in THR and TKR. Outcomes after joint replacement should be assessed with a patient-reported outcome and a functional test. CONCLUSIONS: The RESTORE programme provides important information to guide the development of interventions to improve long-term outcomes for patients with osteoarthritis receiving THR and TKR. Issues relating to their evaluation and the assessment of patient outcomes are highlighted. Potential interventions at key times in the patient pathway were identified and deserve further study, ultimately in the context of a complex intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.Methods: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.Results: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.Conclusions: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. © 2010 Richter et al; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and purpose: Acetabular impaction grafting has been shown to have excellent results, but concerns regarding its suitability for larger defects have been highlighted. We report the use of this technique in a large cohort of patients with the aim of better understanding the limitations of the technique. Methods: We investigated a consecutive group of 339 cases of impaction grafting of the cup with morcellised impacted allograft bone for survivorship and mechanisms for early failure. Results: Kaplan Meier survival was 89.1% (95% CI 83.2 to 95.0%) at 5.8 years for revision for any reason, and 91.6% (95% CI 85.9 to 97.3%) for revision for aseptic loosening of the cup. Of the 15 cases revised for aseptic cup loosening, nine were large rim mesh reconstructions, two were fractured Kerboull-Postel plates, two were migrating cages, one medial wall mesh failure and one impaction alone failed. Interpretation: In our series, results were disappointing where a large rim mesh or significant reconstruction was required. In light of these results, our technique has changed in that we now use predominantly larger chips of purely cancellous bone, 8-10 mm3 in size, to fill the cavity and larger diameter cups to better fill the mouth of the reconstructed acetabulum. In addition we now make greater use of i) implants made of a highly porous in-growth surface to constrain allograft chips and ii) bulk allografts combined with cages and morcellised chips in cases with very large segmental and cavitary defects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has been much discussion and controversy in the media recently regarding metal toxicity following large head metal on metal (MoM) total hip replacement (THR). Patients have been reported as having hugely elevated levels of metal ions with, at times, devastating systemic, neurolgical and/or orthopaedic sequelae. However, no direct correlation between metal ion level and severity of metallosis has yet been defined. Normative levels of metal ions in well functioning, non Cobalt-Chrome hips have also not been defined to date. The Exeter total hip replacement contains no Cobalt-Chrome (Co-Cr) as it is made entirely from stainless steel. However, small levels of these metals may be present in the modular head of the prosthesis, and their effect on metal ion levels in the well functioning patient has not been investigated. We proposed to define the “normal” levels of metal ions detected by blood test in 20 well functioning patients at a minimum 1 year post primary Exeter total hip replacement, where the patient had had only one joint replaced. Presently, accepted normal levels of blood Chromium are 10–100 nmol/L and plasma Cobalt are 0–20 nmol/L. The UK Modern Humanities Research Association (MHRA) has suggested that levels of either Cobalt or Chromium above 7 ppb (equivalent to 135 nmol/L for Chromium and 120 nmol/L for Cobalt) may be significant. Below this level it is indicated that significant soft tissue reaction and tissue damage is less likely and the risk of implant failure is reduced. Hips were a mixture of cemented and hybrid procedures performed by two experienced orthopaedic consultants. Seventy percent were female, with a mixture of head sizes used. In our cohort, there were no cases where the blood Chromium levels were above the normal range, and in more than 70% of cases, levels were below recordable levels. There were also no cases of elevated plasma Cobalt levels, and in 35% of cases, levels were negligible. We conclude that the implantation with an Exeter total hip replacement does not lead to elevation of blood metal ion levels.