980 resultados para Thermal storage wall
Resumo:
An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric tubes heat exchanger with countercurrent water and refrigerating gas flows. The coefficient of performance for the heat pump is calculated by the ratio of energy in the heat storage and the electric power consumed by the domestic refrigerator compressor. The results show that the increasing of hydrostatic pressure in the storage tank increases the water flow rate and the coefficient of performance. The proposed device also reduces the heat dissipation to the surroundings. This is more important in small confinements found in low-cost houses.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis
Resumo:
This paper is proposed the usage of an Organic Rankine Cycle (ORC) along with waste heat recovery from an inconstant heat source. This method of waste heat recovery with intermittent heat source is part of a technical viability study. This paper also brings up the usage of thermal energy storage as heat source for the ORC. This paper is based on a heat treatment company study in which a natural gas furnace is explored. Data such as mass flow, temperature and specific waste gas heat from this furnace are used through calculations. Calculations are made also based on furnace cycles. This viability study considers a series of working fluids such as ammonia, benzene, R113 and R134a. Results point out that ORC with out thermal storage and using refrigerant fluid ammonia is the best alternative
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
In the framework of the micro-CHP (Combined Heat and Power) energy systems and the Distributed Generation (GD) concept, an Integrated Energy System (IES) able to meet the energy and thermal requirements of specific users, using different types of fuel to feed several micro-CHP energy sources, with the integration of electric generators of renewable energy sources (RES), electrical and thermal storage systems and the control system was conceived and built. A 5 kWel Polymer Electrolyte Membrane Fuel Cell (PEMFC) has been studied. Using experimental data obtained from various measurement campaign, the electrical and CHP PEMFC system performance have been determinate. The analysis of the effect of the water management of the anodic exhaust at variable FC loads has been carried out, and the purge process programming logic was optimized, leading also to the determination of the optimal flooding times by varying the AC FC power delivered by the cell. Furthermore, the degradation mechanisms of the PEMFC system, in particular due to the flooding of the anodic side, have been assessed using an algorithm that considers the FC like a black box, and it is able to determine the amount of not-reacted H2 and, therefore, the causes which produce that. Using experimental data that cover a two-year time span, the ageing suffered by the FC system has been tested and analyzed.
Resumo:
Se presenta a continuación un modelo de una planta del almacenamiento de energía mediante aire comprimido siguiendo un proceso adiabático. En esta planta la energía eólica sobrante se usa para comprimir aire mediante un tren de compresión de 25 MW, el aire comprimido será después almacenado en una caverna de sal a 770 metros de profundidad. La compresión se llevará a cabo por la noche, durante 6 horas, debido a los bajos precios de electricidad. Cuando los precios de la electricidad suben durante el día, el aire comprimido es extraído de la caverna de sal y es utilizado para producir energía en un tren de expansión de 70 MW durante 3 horas. La localización elegida para la planta es el norte de Burgos (Castilla y León, España), debido a la coincidencia de la existencia de muchos parques eólicos y una formación con las propiedades necesarias para el almacenamiento. El aspecto más importante de este proyecto es la utilización de un almacenamiento térmico que permitirá aprovechar el calor de la compresión para calentar el aire a la entrada de la expansión, eliminando combustibles fósiles del sistema. Por consiguiente, este proyecto es una atractiva solución en un posible futuro con emisiones de carbono restringidas, cuando la integración de energía renovable en la red eléctrica supone un reto importante. ABSTRACT: A model of an adiabatic compressed air energy storage plant is presented. In this plant surplus wind energy is used to compress air by means of a 25 MW compression train, the compressed air will be later stored in a salt cavern at 770 meters depth. Compression is carried out at night time, during 6 hours, because power prices are lower. When power prices go up during the day, the compressed air is withdrawn from the salt cavern and is used to produce energy in an expansion train of 70 MW during 3 hours. The chosen location for the plant is in the north of Burgos (Castilla y León, Spain), due to both the existence of several wind farms and a suitable storage facility with good properties at the same place. The relevance of this project is that it is provided with a thermal storage, which allows using the generated heat in the compression for re-heating the air before the expansion, eliminating fossil fuels from the system. Hence, this system is an attractive load balancing solution in a possibly carbon-constrained future, where the integration of renewable energy sources into the electric grid is a major challenge.
Resumo:
En este proyecto se elabora la ingeniería básica de un sistema de almacenamiento térmico para la central termosolar Astexol 2 (Badajoz, España). Para ello, primeramente se decidió que el sistema térmico de almacenamiento a diseñar fuera indirecto de dos tanques con sales fundidas. Una vez seleccionado el tipo de almacenamiento adecuado, se seleccionó la capacidad de almacenamiento óptima, en base a unos objetivos establecidos para la instalación del TES en Astexol 2. Finalmente, se procedió con el diseño de los equipos principales y con la realización de los planos de implantación y de los PFD’s (diagramas de flujo) y P&ID’s (diagramas de instrumentación y control) del sistema de almacenamiento. ABSTRACT This project includes the basic engineering of a thermal storage system for the concentrating solar power plant Astexol 2 (Badajoz, Spain). First of all, it was decided that the type of thermal storage system to design had to be an indirect two-tank molten salt thermal storage system. Once the proper type of storage system was chosen, the optimum storage capacity was selected, according to the main aims designated for the thermal storage system installation in Astexol 2.Finally, the design of the main equipment of the thermal storage system was done, together with the elaboration of the associated plot plans, PFD’s (Process Flow Diagrams) and P&ID’s (Process and Instrumentation Diagrams).
Resumo:
La operación cíclica de carga y descarga del almacenamiento en los sistemas CAES induce variaciones de presión y temperatura del aire almacenado. Se requiere pues de modelos que predigan la magnitud de dichas actuaciones para lograr una óptima configuración de la planta de potencia. El modelo se deduce directamente de las ecuaciones de conservación de la masa y de la energía para un sistema homogéneo e isótropo. Es resuelto analítica, para ciertos casos límite de interés, y numéricamente. Se somete al modelo a un análisis de sensibilidad para la determinación de los parámetros característicos más influyentes que afectan a las actuaciones de presión y al volumen de almacenamiento requerido. Se observó que el flujo de calor a través del medio circundante al almacenamiento presenta una influencia sobre éste poco despreciable que debe tenerse en cuenta. Se comparan los casos para sistemas adiabáticos e isotermos para calibrar dicha desviación. Además, se esboza un modelo aproximado que describa el comportamiento del almacenamiento con un almacén térmico (AT) acoplado que regule las variaciones de la temperatura del aire inyectado. Abstract Cyclic charge and discharge operation in CAES systems induce pressure and temperatura fluctuations in the storaged air. It is then required a model that properly describes the magnitud of such fluctutions in order to achieve an optimum power plant configuration. This model is directly deduced from the general conservation principles: conservation of mass and energy, applied into homogeneous and isotropic systems. It was solved analytically for certain specific limiting cases of interest as well as numerically. The model was subjected to a sensibility analysis in order to determine the intrinsic parameters that affect the pressure fluctuations as well as the required storage volume the most. Furthermore it was observed that the heat flux through the sourrounding media of the storage has a non-negligible effect that must be taken into account. Adiabatic and isothermal cases are then compared to each other to determine such a deviation. What is more, it is given a general outline about the model which describes the behaviour of the storage coupled with a thermal storage system(TES) that regulates the inyected air temperature.
Resumo:
Ce mémoire présente un modèle mathématique et numérique pour analyser le comportement d’une unité de stockage thermique à changement de phase solide-liquide représentée par un tube autour duquel se trouve le matériau à changement de phase. Le système est soumis à une charge oscillant entre le chauffage et le refroidissement. Une analyse d’ordre de grandeur permet de prédire le comportement du système en fonction des principaux nombres adimensionnels. Un paramètre adimensionnel est proposé pour délimiter les concepts dans lesquels la conduction domine par rapport à ceux où la convection naturelle domine. L’étude dévoile l’impact des paramètres de conception de l’unité de stockage thermique sur son fonctionnement et approfondit les connaissances dans le domaine du changement de phase avec convection naturelle. Différents indicateurs ont été développés pour analyser la performance du système, tels que les dimensions de la zone affectée thermiquement, le volume fondu ou solidifié et une analyse fréquentielle. Des corrélations sont proposées pour déterminer facilement le comportement du système.
Resumo:
The PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.
Resumo:
Two varieties of adzuki grown in Australia, Bloodwood and Erimo, were stored for up to 6 months at three temperatures (10, 20 and 30 degreesC), and two relative humidities (RH; 40 and 65%). The amount of cell wall material increased with time under all storage conditions. This increase was greatest at 30 degreesC and 40% RH. Storage time and conditions did not affect the total pectin levels in the cell wall. Erimo constantly exhibited a higher total pectin level than Bloodwood. The Bloodwood soluble pectin, Ca++ and Mg++ and Erimo Ca++ in the cell wall remained stable during storage, while the Erimo soluble pectin and Mg++ exhibited a slight decrease at 20 and 30 degreesC after 3 months of storage. (C) 2002 Elsevier Science Ltd. All rights reserved.