974 resultados para Target Held Method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional gentamicin dosing every 8–24 h depending on age and weight in neonates does not provide the ideal concentration–time profile to both optimize the concentration-dependent killing by aminoglycosides and minimize toxicity. Fifty-three neonates were audited prospectively while receiving gentamicin 2.5 mg/kg every 8–24 h, aiming for peak concentrations (Cmax) of 6–10 mg/L and trough concentrations (Cmin) 10 mg/L after the first dose. The mean area under the concentration versus time curve AUC0–24 was 93 mg•h/L (target = 100 mg•h/L). The extended interval dosing achieved higher Cmax values while ensuring that overall exposure per 24 h was acceptable. Prospective testing of the method demonstrated good predictive ability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An inverse, current density mapping (CDM) method has been developed for the design of elliptical cross-section MRI magnets. The method provides a rapid prototyping system for unusual magnet designs, as it generates a 3D current density in response to a set of target field and geometric constraints. The emphasis of this work is on the investigation of new elliptical coil structures for clinical MRI magnets. The effect of the elliptical aspect ratio on magnet performance is investigated. Viable designs are generated for symmetric, asymmetric and open architecture elliptical magnets using the new method. Clinically relevant attributes such as reduced stray field and large homogeneous regions relative to total magnet length are included in the design process and investigated in detail. The preliminary magnet designs have several novel features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a highly sensitive cytolysis test, the fluorolysis assay, as a simple nonradioactive and inexpensive alternative to the standard Cr-51-release assay. P815 cells were stably transfected with a plasmid expressing the enhanced green fluorescent protein (EGFP) gene. These target cells were coated with or without cognate peptide or anti-CD3 Ab and then incubated with CD8(+) T cells to allow antigen-specific or nonspecific lysis. The degree of target cell lysis was measured using flow cytometry to count the percentage of viable propidium iodide(-) EGFP(+) cells, whose numbers were standardized to a reference number of fluorochrome-linked beads. By using small numbers of target cells (200-800 per reaction) and extended incubation times (up to 2 days), the antigen-specific cytolytic activity of one to two activated CD8(+) T cells of a CTL line could be detected. The redirected fluorolysis assay also measured the activity of very few ( greater than or equal to6) primary CD8(+) T cells following polyclonal activation. Importantly, antigen-specific lysis by small numbers ( greater than or equal to 25) of primary CD8(+) T cells could be directly measured ex vivo. This exquisite sensitivity of the fluorolysis assay, which was at least 8-33-folds higher than an optimized 51 Cr-release assay, allows in vitro and ex vivo studies of immune responses that would otherwise not be possible due to low CTL numbers or frequencies. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is presented for calculating the currents and winding patterns required to design independent zonal and tesseral shim coils for magnetic resonance imaging. Both actively shielded and unshielded configurations are considered, and the region of interest can be located asymmetrically with respect to the coil's length. Streamline, target-field and Fourier-series methods are utilized. The desired target-field is specified at two cylindrical radii, on and inside a circular conducting cylinder of length 2L and radius a. The specification is over some asymmetric portion pL < z < qL of the coil's length (-1 < p < q < 1). Arbitrary functions are used in the outer sections, -L < z < pL and qL < z < L, to ensure continuity of the magnetic field across the entire length of the coil. The entire field is then periodically extended as a half-range cosine Fourier series about either end of the coil. The resultant Fourier coefficients are then substituted into the Fourier-series expressions for the internal and external magnetic fields, and current densities and stream functions on both the primary coil and shield. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis and shielding analysis on field calculations from a ZX shim coil indicate that example designs and theory are well matched.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Learning is not a spectator’s sport. Students do not learn much by just sitting in class listening their teachers, memorizing pre-packaged assignments and spitting out answers. The teaching-learning process has been a constant target of studies, particularly in Higher Education, in consequence of the annual increase of new students. The concern with maintaining a desired quality level in the training of these students, conjugated with the will to widen the access to all of those who finish Secondary School Education, has triggered a greater intervention from the education specialists, in partnership with the teachers of all Higher Education areas, in the analysis of this problem. Considering the particular case of Engineering, it has been witnessed a rising concern with the active learning strategies and forms of assessment. Research has demonstrated that students learn more if they are actively engaged with the material they are studying. In this presentation we describe, present and discuss the techniques and the results of Peer Instruction method in an introductory Calculus courses of an Engineering Bach

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to present a contrastive approach between three different ways of building concepts after proving the similar syntactic possibilities that coexist in terms. However, from the semantic point of view we can see that each language family has a different distribution in meaning. But the most important point we try to show is that the differences found in the psychological process when communicating concepts should guide the translator and the terminologist in the target text production and the terminology planning process. Differences between languages in the information transmission process are due to the different roles the different types of knowledge play. We distinguish here the analytic-descriptive knowledge and the analogical knowledge among others. We also state that none of them is the best when determining the correctness of a term, but there has to be adequacy criteria in the selection process. This concept building or term building success is important when looking at the linguistic map of the information society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Target tracking with bearing-only sensors is a challenging problem when the target moves dynamically in complex scenarios. Besides the partial observability of such sensors, they have limited field of views, occlusions can occur, etc. In those cases, cooperative approaches with multiple tracking robots are interesting, but the different sources of uncertain information need to be considered appropriately in order to achieve better estimates. Even though there exist probabilistic filters that can estimate the position of a target dealing with incertainties, bearing-only measurements bring usually additional problems with initialization and data association. In this paper, we propose a multi-robot triangulation method with a dynamic baseline that can triangulate bearing-only measurements in a probabilistic manner to produce 3D observations. This method is combined with a decentralized stochastic filter and used to tackle those initialization and data association issues. The approach is validated with simulations and field experiments where a team of aerial and ground robots with cameras track a dynamic target.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oceans - San Diego, 2013

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACTINTRODUCTION: In the Americas, mucosal leishmaniasis is primarily associated with infection by Leishmania (Viannia) braziliensis. However, Leishmania (Viannia) guyanensis is another important cause of this disease in the Brazilian Amazon. In this study, we aimed at detecting Leishmaniadeoxyribonucleic acid (DNA) within paraffin-embedded fragments of mucosal tissues, and characterizing the infecting parasite species.METHODS: We evaluated samples collected from 114 patients treated at a reference center in the Brazilian Amazon by polymerase chain reaction (PCR) and restriction fragment length polymorphism (RFLP) analyses.RESULTS: Direct examination of biopsy imprints detected parasites in 10 of the 114 samples, while evaluation of hematoxylin and eosin-stained slides detected amastigotes in an additional 17 samples. Meanwhile, 31/114 samples (27.2%) were positive for Leishmania spp. kinetoplast deoxyribonucleic acid (kDNA) by PCR analysis. Of these, 17 (54.8%) yielded amplification of the mini-exon PCR target, thereby allowing for PCR-RFLP-based identification. Six of the samples were identified as L. (V.) braziliensis, while the remaining 11 were identified as L. (V.) guyanensis.CONCLUSIONS: The results of this study demonstrate the feasibility of applying molecular techniques for the diagnosis of human parasites within paraffin-embedded tissues. Moreover, our findings confirm that L. (V.) guyanensisis a relevant causative agent of mucosal leishmaniasis in the Brazilian Amazon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Finfish pots have emerged as a “responsible” gear, when used in combination with conservational and technical measures to sustain fisheries. Previous trials in Irish waters have offered no published reported data and so three designs tested in the current study provide new information on this gear. The most successful traps in terms of fish catch were rigid steel framed rectangular pots used to target Conger eel. Although commercial yield was low (0.2 per trap haul), potential existed for a viable pot fishery. Deployment and storage of Norwegian floating pots was conducted with relative ease but performance in the water was poor resulting in loss of gear. Catch returns were notable even though effort was restricted as mega-faunal by-catch was a problem, which lead to ending this trial. From these initial trials it was evident that catch rates were low compared to established Norwegian fisheries (3.6 cod per pot), which resulted in the utilisation of pots, already established in the crustacean fishery, to find species readily accessible to pot capture. Although fished and designed differently, these gears provided an opportunity to establish the benefits of pot fishing to fish quality and to determine the effects on by-catch. The fishing effects of three catching methods (pots, angling and trawl) and the effects of air exposure on the physiological status of a common by-catch, the lesser spotted dogfish Scyliorhinus canícula (L.) were examined using a range of physiological biomarkers (plasma catecholamine, glucose, lactate, muscle pH and muscle lactate). Physiological responses of fish to an emersion stress regime resulted in a significant metabolic disturbance in groups, but may not have weakened the overall health of these fish, as signified in the revival of some metabolites. Plasma glucose and lactate concentrations did not however recovery to baseline levels indicating that to achieve an accurate profile, responses should be determined by a suite of biomarkers. Responses did not demonstrate that samples from the pots were significantly less stressed than for the other two methods; angling and trawling, which are in contrast to many other studies. Employment of finfish potting therefore in Irish waters needs further consideration before further promotion as a more responsible method to supplement or replace established techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.